{"product_id":"mitsubishi-electric-fr-a840-00126-2-60-a800-series-inverter-drive","title":"Mitsubishi Electric FR-A840-00126-2-60 A800 Series Inverter Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIndustrial motor speed control and torque optimization are managed via the \u003cstrong\u003eFR-A840-00126-2-60\u003c\/strong\u003e high-performance \u003cstrong\u003einverter drive\u003c\/strong\u003e, a core component within the Mitsubishi Electric A800 range. Designed for demanding applications requiring constant torque, this three-phase variable frequency drive offers precision speed regulation through real sensorless vector control and closed-loop vector control up to 400 Hz. The unit features backward compatibility with the older FR-A700 series, simplifying system upgrades without requiring complete mechanical redesigns.\u003c\/p\u003e\n\n\u003cp\u003eThe unit incorporates an integrated Mitsubishi L-Series PLC with up to 6K steps of program memory, allowing users to run custom control logic directly on the drive. For safety-critical environments, the drive is equipped with PLd and SIL2 safety standards as standard, which can be further expanded via specialized plug-in options. Program files and parameters can be password-protected to prevent unauthorized modification, ensuring secure operations in automated processing facilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReal sensorless vector control and closed-loop vector control capable of operating up to 400 Hz.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Mitsubishi L-Series PLC functionality offering up to 6K steps of programmable memory.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in brake chopper on models up to 55kW for efficient regenerative braking management.\u003c\/li\u003e\n  \u003cli\u003eSupports 24V DC control circuit input to facilitate parameter access, safety maintenance, and communication without main power.\u003c\/li\u003e\n  \u003cli\u003eEquipped with a USB (Type A) port for rapid parameter copying and configuration backup.\u003c\/li\u003e\n  \u003cli\u003ePlug-and-play compatibility with GOT2000 Series HMIs for direct monitoring and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eIntegrated temperature sensor to monitor internal thermal conditions and optimize fan speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy industrial winding and tensioning control systems.\u003c\/li\u003e\n  \u003cli\u003eOverhead cranes, hoists, and material handling gantries.\u003c\/li\u003e\n  \u003cli\u003eMachine tool spindles and high-speed drilling axes.\u003c\/li\u003e\n  \u003cli\u003eVariable-speed conveyor networks in logistics and manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-A840-00126-2-60\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Power Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400 \/ 415 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhases\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDuty Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConstant Torque (moderate and heavy duty)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePLd, SIL2 (standard configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e260 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e140 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install vertically on a flat, vibration-free surface. Ensure adequate clearance around the drive heatsinks for efficient cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route control cables separately from main power and motor output cables to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always establish a reliable low-impedance ground connection to the dedicated ground terminal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Power:\u003c\/strong\u003e Connect external 24V DC to the control terminal block if configuration or diagnostics are required while main 400V power is isolated.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102145732971,"sku":"FR-A840-00126-2-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FR-A840-00126-2-60-j14jwrwi1tj.png?v=1776137442","url":"https:\/\/www.plcprotech.com\/ru\/products\/mitsubishi-electric-fr-a840-00126-2-60-a800-series-inverter-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}