{"product_id":"mitsubishi-electric-gt1695m-xtba-c-got1000-graphic-operation-terminal","title":"Mitsubishi Electric GT1695M-XTBA-C GOT1000 Graphic Operation Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to deliver high-resolution monitoring and robust machine control, the Mitsubishi Electric GT1695M-XTBA-C stands as an elite 15-inch human-machine interface (HMI) within the legacy GOT1000 platform. This unit provides process-critical visualization in demanding industrial environments, combining a vivid TFT color display with expansive memory capacity and multiple communication interfaces. Designed to withstand mechanical stress and harsh atmospheric conditions, it serves as a reliable central control node for plant-floor diagnostics, parameter adjustment, and complex process automation workflows.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e 15-inch TFT color screen supporting crisp XGA resolution (1024 x 768 pixels) for detailed process screens.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultilingual Support:\u003c\/strong\u003e Dynamic language switching capabilities for global deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpansive Connectivity:\u003c\/strong\u003e Integrated Ethernet, RS-232, and RS-422\/485 serial communication interfaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Expansion:\u003c\/strong\u003e Dedicated CompactFlash (CF) card slot for historical data logging, recipe storage, and OS backups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e Heavy-duty construction conforming to international shock, vibration, and atmospheric standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly line monitoring and robotic cell integration.\u003c\/li\u003e\n  \u003cli\u003eComplex packaging and converting machinery control panels.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal treatment monitoring.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor manufacturing cleanroom diagnostic interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGT1695M-XTBA-C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGOT1000 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e15 Inches\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTFT Color LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eXGA (1024 x 768 Pixels)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 V AC to 240 V AC (+10%, -15%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Ambient Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Ambient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10% to 90% RH, Non-Condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eImpact Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConforming to JIS B 3502 and IEC 61131-2 (147 m\/s2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eIngress Protection (Front)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP67F (When installed using appropriate gasket)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eInterface \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eFunctional Purpose\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHost controller communication \u0026amp; programming uploading\/downloading\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRS-232\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eD-Sub 9-pin Male\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDirect connection to legacy PLCs, barcode readers, or printers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRS-422\/485\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eD-Sub 9-pin Female\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMulti-drop serial networks with compatible controllers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Host\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eType A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eExternal keyboard\/mouse input and USB memory stick data storage\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Device\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMini-B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDirect PC transfer point for GT Works3 screen design software\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe GT1695M-XTBA-C acts as a direct physical and functional successor to the GT1595-XTBA model. While screen project data can be migrated seamlessly using Mitsubishi's GT Works3 software, engineers must verify that communications protocol drivers are updated to correspond with newer firmware configurations. Mounting bracket footprints remain compatible, easing physical cabinet swap-outs.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent thermal accumulation when mounting the terminal in completely sealed IP67 enclosures, ensure a minimum of 100mm of vertical clearance is maintained from any heat-generating auxiliary components (such as variable frequency drives or large power supplies). Operating this unit constantly at its upper thermal limit of 50 degC will reduce the service life of the CCFL backlight assembly.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that the functional ground (FG) terminal on the main power supply block is connected directly to a dedicated class-D ground point (resistance of 100 ohms or less) using a minimum 2 mm2 ground wire. Failure to isolate the terminal ground from high-current machinery ground paths may result in intermittent touch screen offset issues or communications drops on serial channels.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical supply circuits feeding the enclosure before beginning mechanical or electrical installation of this terminal. High voltage (up to 240V AC) is present on the power connection terminals. Allow internal storage capacitors to discharge completely for at least 10 minutes prior to handling internal communication expansion modules or wiring paths.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 10px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 14px;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eVerify panel cutout dimensions correspond precisely to the GT1695 standard installation template to maintain the IP67F dust and liquid seal.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 10px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 14px;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eInsert the terminal into the cutout from the front, ensuring the rubber sealing gasket is flat and free of twists.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 10px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 14px;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eSecure the provided mounting brackets to the terminal body rear channels, tightening the mounting screws evenly to the recommended torque specifications (0.36 to 0.48 N-m) to prevent panel distortion.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 14px;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConnect the isolated AC power wiring and ensure standard communication cable shields are grounded at the controller side.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102125220203,"sku":"GT1695M-XTBA-C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt1695m-xtba-c-2rfh4prahgp.png?v=1776137601","url":"https:\/\/www.plcprotech.com\/ru\/products\/mitsubishi-electric-gt1695m-xtba-c-got1000-graphic-operation-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}