{"product_id":"mitsubishi-electric-me96nsr-me96-series-electronic-multi-measuring-instrument","title":"Mitsubishi Electric ME96NSR ME96 Series Electronic Multi-Measuring Instrument","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to facilitate precision power monitoring and energy conservation auditing in high-density electrical panels, the \u003cstrong\u003eMitsubishi Electric ME96NSR\u003c\/strong\u003e delivers high-accuracy tracking of critical AC electrical network variables. This panel-mount electronic multi-measuring instrument fits a standard \u003cstrong\u003e96x96 mm (1\/4 DIN)\u003c\/strong\u003e cutout, consolidating the functions of multiple traditional analog meters into a single, high-reliability digital unit. Featuring a clear, back-lit monochrome LCD with a visual dial-style bar graph, the device allows local operators to monitor current, voltage, active\/reactive power, active energy, and harmonic distortion. Its flexible backplane supports optional communication and I\/O expansion modules, allowing seamless integration into automation frameworks including \u003cstrong\u003eCC-Link\u003c\/strong\u003e and MODBUS architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eComprehensive Energy Metrics:\u003c\/strong\u003e Simultaneous measurement of Phase Voltage, Line Voltage, Phase Current, Active\/Reactive\/Apparent Power, Power Factor, Frequency, and Active\/Reactive Energy.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHarmonic Analysis:\u003c\/strong\u003e Built-in capability to measure and display total harmonic distortion (THD) and individual harmonic components up to the 19th order.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e Rear-slot architecture accepts optional plug-in modules to add CC-Link communication, Modbus RTU, analog outputs, or digital inputs and outputs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Visibility Super Dial Display:\u003c\/strong\u003e Combination segment display and circular LCD bar graph provides immediate analog-style load tracking alongside exact digital values.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRobust Non-Volatile Memory:\u003c\/strong\u003e Retains configuration parameters and accumulated electrical energy data during auxiliary control power disruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Real-time loading diagnostics for motor control centers (MCCs) and distribution switchgear.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFacility Energy Management:\u003c\/strong\u003e Accurate sub-metering of sub-stations and specific manufacturing lines to track carbon footprint and power factor targets.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eSCADA Integration:\u003c\/strong\u003e Local data concentrator and field telemetry node transmitting parameters to central control rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification Values\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eME96NSR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMonochrome LCD with Backlight (Segment and Bar Graph)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAuxiliary Control Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e110 to 240 V AC (+10%, -15%), 50\/60 Hz ; 75 to 140 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-phase 4-wire, 3-phase 3-wire, 1-phase 3-wire, 1-phase 2-wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMeasurement Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage\/Current: 0.5%, Active Power: 0.5%, Active Energy: Class 1.0 (IEC62053-21)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Ambient Temp\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-5 to 50 degC (Daily average maximum limit: 35 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Ambient Temp\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30% to 85% RH (Non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePhysical Dimensions (WxHxD)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e96 x 96 x 96 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStandards Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEMC: EN61326-1:2006, Safety: EN61010-1:2001\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWeight (Net)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 kg (with typical protective industrial packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e150 x 150 x 150 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal Label Block\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eFunctional Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMA, MB\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAuxiliary Control Power input terminals (110-240V AC \/ 75-140V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eP1, P2, P3, PN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage Input circuit measurement points (Phase 1, 2, 3, and Neutral)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e1S, 1L \/ 2S, 2L \/ 3S, 3L\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCurrent Input transformer loops (S: Source side CT connection, L: Load side CT connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEarth Terminal (GND)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInstrument chassis ground connection point\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \u003cstrong\u003eME96NSR\u003c\/strong\u003e belongs to the legacy \"Super Dial\" series of meters. While physical drop-in compatibility exists across most 96x96 mm configurations (such as the newer ME96SS series), note that expansion modules must match the respective product family. Do not attempt to force ME96SS optional communication blocks into the rear slots of an ME96NSR, as interface pin alignments and firmware drivers differ significantly.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common engineering pitfall involves mismatching the physical Current Transformer (CT) secondary rating (typically 1A or 5A) with the software setting scaled inside the ME96NSR setup menu. An incorrect menu selection will lead to completely skewed active power and energy integration registers without triggering any device diagnostic fault code. Ensure the external CT ratios are verified and correctly configured upon initial powering.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways route current transformer signals using twisted-pair shielded cabling, keeping them isolated from high-voltage primary busbars to minimize electromagnetic noise on the measurement loops. Connect the S2 terminal of all current transformers to a local clean control ground. If using expansion modules, make sure the modules are fully seated and their retaining screws are locked down before applying control power to prevent communication dropouts.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous high voltage is present at the input terminals of this device. Always de-energize the primary circuit and isolate auxiliary control power lines before performing any connection, wire routing, or module installation. Always verify zero voltage status with calibrated instruments before handling terminal screws.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eEnsure a precise 92 x 92 mm (+0.8\/-0 mm) square panel cutout is prepared, clean of burrs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eInsert the ME96NSR housing through the panel cutout from the front, ensuring the protective dust gasket sits flat against the outer panel surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eSecure the instrument from behind using the provided slide-on mounting brackets. Tighten the clamping screws evenly to secure the meter without warping the plastic casing.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003ePerform connection of voltage, current (CT secondary), ground, and auxiliary power wires strictly following the appropriate phase wiring diagram on the housing.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102153040235,"sku":"ME96NSR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ME96NSR-ftsl5v22waz.png?v=1776137812","url":"https:\/\/www.plcprotech.com\/ru\/products\/mitsubishi-electric-me96nsr-me96-series-electronic-multi-measuring-instrument","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}