{"product_id":"omron-d4bl-2drg-d4bl-series-guard-lock-safety-door-switch","title":"Omron D4BL-2DRG D4BL Series Guard Lock Safety-Door Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to secure heavy-duty machinery safeguarding systems, the \u003cstrong\u003eD4BL-2DRG\u003c\/strong\u003e heavy-duty \u003cstrong\u003eguard lock safety-door switch\u003c\/strong\u003e provides mechanical locking and solenoid release to protect personnel from hazardous machine areas. This Type 2 safety switch incorporates a high-durability die-cast aluminum housing, making it highly suitable for demanding industrial automation setups that require strict safety compliance.\u003c\/p\u003e\n\n\u003cp\u003eOperating with a 24 VDC solenoid lock mechanism, the switch remains securely locked until a release signal is received, preventing accidental entry during dangerous cycles. It is configured with a 2-conduit G1\/2 outlet design and a highly adaptable head supporting four distinct mounting orientations, streamlining physical integration on various safety fence profiles.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRugged metal die-cast aluminum housing for harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eSecure solenoid lock with mechanical release function for fail-safe door control.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in switch assembly containing 2NC (slow-action) and 1NC (slow-action) contacts.\u003c\/li\u003e\n  \u003cli\u003eAdjustable head mount allows selection of four different installation directions.\u003c\/li\u003e\n  \u003cli\u003eIP67 degree of protection against ingress of dust and liquids.\u003c\/li\u003e\n  \u003cli\u003eType 2 interlock device classified as low-level coded according to EN ISO 14119.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eRobotic cell enclosures and high-risk work zones.\u003c\/li\u003e\n  \u003cli\u003eHeavy machining, milling, and metal-stamping equipment guarding.\u003c\/li\u003e\n  \u003cli\u003eHigh-inertia industrial machinery that requires delay-to-access control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eD4BL-2DRG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eD4BL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGuard Lock Safety-Door Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLock Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolenoid lock \/ Mechanical release\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolenoid Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterlock Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 2 (EN ISO 14119)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoding Level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow Level coded (EN ISO 14119)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBuilt-in Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2NC (slow-action) + 1NC (slow-action)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConduit Outlet\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eG1\/2 (2-conduit type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHead Mounting Direction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFour directions possible (ships configured for right-side mounting)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIndicator Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (without indicator)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67 (EN60947-5-1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,000,000 operations minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Durability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500,000 operations minimum (10 A resistive load at 250 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.05 to 0.5 m\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 operations\/minute maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the operation key is aligned properly with the key slot before securing the main switch body.\u003c\/li\u003e\n  \u003cli\u003eDo not use the safety switch as a mechanical stop for the door; physical door stoppers must be installed independently.\u003c\/li\u003e\n  \u003cli\u003eProvide a stable, regulated 24 VDC supply voltage to the solenoid coil to prevent chatter or incomplete unlocking.\u003c\/li\u003e\n  \u003cli\u003eMount the switch and its wiring in accordance with EN ISO 14119 specifications to preserve the intended safety integrity level (SIL\/PL).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEN ISO 14119\u003c\/li\u003e\n  \u003cli\u003eEN 60947-5-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077908193643,"sku":"D4BL-2DRG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/d4bl-2drg-xaznjif2vsj.png?v=1775733710","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-d4bl-2drg-d4bl-series-guard-lock-safety-door-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}