{"product_id":"omron-ns8-tv00-ecv2-ns-series-programmable-terminal","title":"Omron NS8-TV00-ECV2 NS Series Programmable Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Processing plant visualization and machine-level control are streamlined via the Omron NS8-TV00-ECV2, an advanced human-machine interface (HMI) designed for seamless integration with Sysmac automation architectures. Engineered with a highly responsive 8.4-inch TFT color LCD display, this unit delivers exceptional clarity for complex graphical interfaces, alarm monitoring, and real-time data logging. The \u003cstrong\u003eOmron NS8-TV00-ECV2\u003c\/strong\u003e features dual serial RS-232C ports, USB connectivity, and an embedded Ethernet port (10Base-T\/100Base-TX) for robust communications with PLCs, motion controllers, and network switches. Its structural resilience and IP65F-rated front panel make it suitable for challenging factory floor environments.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Resolution TFT Display:\u003c\/strong\u003e 8.4-inch screen displaying 256 colors at a crisp 640 x 480 pixel resolution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Communication Protocol Support:\u003c\/strong\u003e Supports Controller Link, Ethernet, and serial protocols for easy configuration with Omron CS\/CJ\/CP series PLCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Memory Management:\u003c\/strong\u003e Built-in flash memory for screens, logging data, and recipe parameters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual RS-232C Interfaces:\u003c\/strong\u003e Independent serial channels allow simultaneous connections to peripherals, barcode readers, or temperature controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Front Panel Protection:\u003c\/strong\u003e IP65F environmental rating protects against moisture, dust, and direct splashing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomated assembly lines and material handling visualization systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging and food processing equipment requiring hygienic, sealed front panel enclosures.\u003c\/li\u003e\n  \u003cli\u003eWater treatment facilities and HVAC plant monitoring consoles.\u003c\/li\u003e\n  \u003cli\u003eChemical dosing systems and industrial oven control units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNS8-TV00-ECV2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries Name\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNS Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Device\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8.4-inch High-luminance TFT Color LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e640 x 480 Pixels (VGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eColors\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e256 Colors (System \/ Images up to 32,768 colors)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRated Power Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAllowable Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20.4 to 27.6 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e25 W Maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommunication Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1x Ethernet (10Base-T\/100Base-TX), 2x RS-232C, 1x USB Type B (Slave), 1x USB Type A (Host)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65F (Front panel equivalent when mounted)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e300 x 240 x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eConnector \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePort A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS-232C (D-Sub 9-pin Female)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHost Link \/ NT Link \/ Barcode Reader connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePort B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS-232C (D-Sub 9-pin Female)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHost Link \/ NT Link \/ Temperature Controller connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45 (10Base-T \/ 100Base-TX)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFINS Communications, Screen Data Transfer, Web Server\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Host\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSB Type A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eData Logging storage \/ System update via USB memory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Slave\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSB Type B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHigh-speed screen transfer from CX-Designer\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003eNS8-TV00-ECV2\u003c\/strong\u003e features an integrated Ethernet port, separating it from the standard NS8-TV00-V2, which relies strictly on serial communications unless retrofitted with an optional network module. This model is directly backwards compatible with legacy NS8-TV00 projects. When transferring project data from older V1 hardware revisions, verify that CX-Designer is updated to at least v3.0 or higher to correctly compile the updated system programs (such as System v8.x or above) required for the ECV2 platform.\n\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To prevent localized heat buildup within sealed enclosures, maintain a minimum clearance of 100 mm from the top and bottom of the HMI unit. Under continuous 24-hour operation, CCFL-backlit or early LED-backlit screens are prone to phosphor degradation or burn-in. Implement the \u003cem\u003eBacklight Auto-Off\u003c\/em\u003e function within the system settings, set to deactivate after 10 to 15 minutes of idle time. This simple software setting dramatically extends backlight longevity beyond the rated 50,000-hour limit.\n\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When wiring the 24 VDC power connection, always route the DC power through a dedicated class 2 power supply separate from high-current inductive loads (such as contactors or solenoids). Additionally, terminate the functional ground (GR) terminal using 2 mm squared or thicker wiring to a dedicated single-point earth ground. This prevents high-frequency electrical noise from degrading Ethernet and RS-232 serial communication signals.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003e\n    Prior to performing physical installation, panel mounting, or wiring modifications on the NS8-TV00-ECV2, completely disconnect and lock out all upstream electrical power sources. Verify that the power lines are fully de-energized. Failure to strictly observe physical lockout\/tagout protocols can cause catastrophic hardware damage, communication port degradation, or severe electrical shock to personnel.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-size: 0.85rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Prepare a clean rectangular panel cutout measuring exactly 220.5 mm (+1.0\/-0 mm) horizontally by 165.5 mm (+1.0\/-0 mm) vertically. Ensure the panel thickness is between 1.6 mm and 4.8 mm.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-size: 0.85rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Verify that the waterproof gasket is seamlessly installed in its groove on the rear outer rim of the HMI bezel. Do not use damaged or twisted gaskets, as this voids the IP65F environmental rating.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-size: 0.85rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Insert the HMI terminal through the cutout from the front of the mounting panel. Secure the unit using the included mounting brackets, tightening the screws to a target torque range of 0.5 to 0.6 N-m. Over-tightening can warp the front bezel, causing touchscreen misalignment.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-size: 0.85rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Connect the dedicated functional ground (GR) wire to the earth terminal before terminating the 24 VDC power lines. Once secure, connect communication cables and power up the system to verify communication link status.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077928542571,"sku":"NS8-TV00-ECV2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ns8-tv00-ecv2-g5mzdcwdwwz.png?v=1775733933","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-ns8-tv00-ecv2-ns-series-programmable-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}