{"product_id":"omron-nx-da3205-nx-series-analog-output-unit","title":"Omron NX-DA3205 NX Series Analog Output Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-density distributed control environments, the Omron NX-DA3205 Analog Output Unit provides four high-precision analog output channels within a compact 12 mm slice form factor. Operating on the high-speed \u003cstrong\u003eNX I\/O Bus\u003c\/strong\u003e, this module enables precise current-loop control with a \u003cstrong\u003e15-bit resolution\u003c\/strong\u003e and synchronous I\/O refreshing, making it highly suited for precise positioning, proportional valve modulation, and variable speed drive integration in Sysmac Studio architectures.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFour high-precision analog outputs\u003c\/strong\u003e supporting standard 4 to 20 mA current loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-bit digital-to-analog conversion resolution\u003c\/strong\u003e ensures exceptional control granularity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSynchronous I\/O refreshing\u003c\/strong\u003e synchronizes output timing with the primary EtherCAT master cycle.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-fast conversion time\u003c\/strong\u003e of 0.04 ms per unit for dynamic, real-time application responses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTool-free Push-In Plus wiring technology\u003c\/strong\u003e reduces panel assembly time and prevents loose connections caused by vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProportional Valve Control:\u003c\/strong\u003e Smooth, repeatable modulation of hydraulic and pneumatic flow rates.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Speed Regulation:\u003c\/strong\u003e Accurate frequency commands sent directly to variable speed drives (VFDs).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Control Loops:\u003c\/strong\u003e Setpoint transmission to remote regulatory controllers and actuators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Element Modulation:\u003c\/strong\u003e Interfacing with analog power regulators for precise temperature profiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNX-DA3205\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNX Series I\/O System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAnalog Output Unit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eNumber of Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eOutput Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 to 20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e15-bit (1\/30,000 full scale)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eConversion Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.04 ms per unit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSignal Processing Mode\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSynchronous I\/O refreshing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eI\/O Connection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePush-In Plus terminal block (8 terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 mm x 100 mm x 71 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.07 kg (70 grams)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.25 kg (including standard protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIf system specifications allow for fewer outputs, the NX-DA2205 serves as a direct 2-channel alternative. Note that standard 4 to 20 mA signals require correct programming of the upper and lower limit scaling within the Sysmac Studio configuration environment. Ensure that your NX Coupler Unit (e.g., NX-ECC201 or NX-ECC202) has firmware version 1.0 or later to ensure seamless communication with this analog slice.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the integrity of the 15-bit D\/A conversion, always route analog output lines away from high-voltage AC cables and motor feeder cables. Shielded twisted-pair (STP) cabling is strongly recommended to protect current signals from high-frequency electrical noise emitted by adjacent motor drives.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe Push-In Plus terminal block accepts solid wire or stranded wire terminated with ferrules. Avoid using bare stranded wire to ensure long-term physical stability in heavy vibration zones. Terminal block release keys can be depressed with a standard 2.5 mm flathead screwdriver to remove wires if necessary.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary system power supplies, including field power supplied to the NX bus, before inserting or removing the terminal block or changing the module configuration. Hot-swapping modules or working on active current-loop wiring can cause permanent hardware damage to the analog circuitry or field equipment.\n\u003c\/div\u003e\n\n\u003col style=\"list-style: none; padding-left: 0; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eMount the NX-DA3205 unit directly onto a standard 35 mm DIN rail by clicking the unit’s locking hook securely onto the rail track.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eSlide adjacent NX Series modules together until the internal side-connector interface pins are completely engaged.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eInsert 4 to 20 mA loop wires directly into the designated Push-In Plus terminal points. Keep wire stripping length between 8 mm and 10 mm.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eConnect the cable shield to a functional ground terminal point on the machine panel for optimal electromagnetic compatibility.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077906227563,"sku":"NX-DA3205","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-da3205-slgw0ppjf5c.png?v=1775733970","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-nx-da3205-nx-series-analog-output-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}