{"product_id":"omron-nx-ecc202-omron-nx-series-ethercat-coupler-unit","title":"Omron NX-ECC202 | Omron | NX-series EtherCAT Coupler Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNX-ECC202\u003c\/strong\u003e is an \u003cstrong\u003eEtherCAT Coupler Unit\u003c\/strong\u003e from the \u003cstrong\u003eNX-series\u003c\/strong\u003e, designed to act as the primary interface between an \u003cstrong\u003eEtherCAT\u003c\/strong\u003e network master and the distributed \u003cstrong\u003eNX-series I\/O modules\u003c\/strong\u003e. This unit facilitates high-speed, deterministic data exchange, supporting up to \u003cstrong\u003e63 connectable NX Units\u003c\/strong\u003e on a single slave node. Utilizing the \u003cstrong\u003e100BASE-TX (IEEE 802.3)\u003c\/strong\u003e physical layer with a \u003cstrong\u003e100 Mbps\u003c\/strong\u003e baud rate, the \u003cstrong\u003eNX-ECC202\u003c\/strong\u003e ensures seamless synchronization and communication within complex machine control architectures. The device is intended for panel mounting and requires integration into an EtherCAT network managed by a compatible master controller.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtocol: \u003cstrong\u003eEtherCAT\u003c\/strong\u003e (100 Mbps baseband modulation)\u003c\/li\u003e\n\u003cli\u003eCapacity: Supports up to 63 \u003cstrong\u003eNX-series I\/O modules\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhysical Layer: 100BASE-TX (IEEE 802.3)\u003c\/li\u003e\n\u003cli\u003eMounting: Panel-mounted enclosure\u003c\/li\u003e\n\u003cli\u003eGrounding: Requires a ground resistance of 100 Ohm or less\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O systems in industrial automation\u003c\/li\u003e\n\u003cli\u003eHigh-speed synchronized machine control\u003c\/li\u003e\n\u003cli\u003eModular PLC architectures\u003c\/li\u003e\n\u003cli\u003eFactory automation network integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-ECC202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Coupler Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Connectable Units\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX (IEEE 802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePanel Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003e100 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 cm x 4.6 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit inside an industrial control panel. Ensure adequate spacing around the device for ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e To ensure signal integrity and electrical safety, connect the functional ground terminal to a common ground point with a resistance of 100 Ohm or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e Use shielded twisted-pair (STP) Category 5e or higher cables for 100BASE-TX EtherCAT connections to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology:\u003c\/strong\u003e The network topology must comply with the configuration and capabilities of the designated EtherCAT master controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077939257707,"sku":"NX-ECC202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/NX-ECC202-d1oko31vfo5.png?v=1775733980","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-nx-ecc202-omron-nx-series-ethercat-coupler-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}