{"product_id":"omron-nx-ts2104-nx-series-temperature-input-unit","title":"Omron NX-TS2104 NX Series Temperature Input Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-precision thermal monitoring within the Sysmac automation platform, the \u003cstrong\u003eOmron NX-TS2104\u003c\/strong\u003e temperature input module provides dual-channel thermocouple interfacing with rapid processing capabilities. This compact I\/O unit integrates seamlessly into the Omron NX Series bus system, delivering reliable temperature measurements for closed-loop control applications. Operating on a free-run refreshing method, it features a fast conversion time of 60 ms per unit and achieves an exceptional resolution of 0.001 degC maximum, ensuring highly responsive and stable tracking of thermal dynamics.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eNX-TS2104\u003c\/strong\u003e supports a broad selection of standard industrial thermocouple types, facilitating straightforward integration with existing sensor networks. Its robust electrical design incorporates transformer and digital isolator technology to isolate signal paths between the input channels, as well as between the inputs and the internal NX bus. Wiring is simplified through a high-density, 16-point screwless clamping terminal block, which reduces installation time and minimizes the risk of loose connections in high-vibration environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-point thermocouple input interface for targeted temperature monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports a wide range of thermocouple sensors including K, J, T, E, L, U, N, R, S, WRe5-26, and PLII.\u003c\/li\u003e\n  \u003cli\u003eFast 60 ms per unit conversion rate suitable for dynamic thermal processes.\u003c\/li\u003e\n  \u003cli\u003eHigh-precision performance with a resolution limit of 0.001 degC.\u003c\/li\u003e\n  \u003cli\u003eComplete electrical isolation between individual input channels and the backplane bus.\u003c\/li\u003e\n  \u003cli\u003eMaintenance-free, 16-terminal screwless clamping terminal block for rapid wiring.\u003c\/li\u003e\n  \u003cli\u003eFree-Run I\/O refreshing method for continuous data synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlastic extrusion and injection molding temperature control.\u003c\/li\u003e\n  \u003cli\u003eIndustrial heat treatment furnaces and drying ovens.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery requiring precise heat-sealing controls.\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing sterilization systems.\u003c\/li\u003e\n  \u003cli\u003eChemical and pharmaceutical reactor temperature monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eNX-TS2104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eTemperature Input Unit (Thermocouple)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Points\u003c\/strong\u003e\n      \u003ctd\u003e2 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCompatible Sensor Types\u003c\/strong\u003e\n      \u003ctd\u003eK, J, T, E, L, U, N, R, S, WRe5-26, PLII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConversion Time\u003c\/strong\u003e\n      \u003ctd\u003e60 ms \/ Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eResolution\u003c\/strong\u003e\n      \u003ctd\u003e0.001 degC max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eI\/O Refreshing Method\u003c\/strong\u003e\n      \u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Impedance\u003c\/strong\u003e\n      \u003ctd\u003e20 kOhm min.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAbsolute Maximum Rating\u003c\/strong\u003e\n      \u003ctd\u003e±130 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Disconnection Detection Current\u003c\/strong\u003e\n      \u003ctd\u003eApprox. 0.1 micro-Amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWarm-up Period\u003c\/strong\u003e\n      \u003ctd\u003e45 minutes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eIsolation Method\u003c\/strong\u003e\n      \u003ctd\u003ePower: Transformer; Signal: Digital isolator (between inputs and NX bus, and between inputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\n      \u003ctd\u003e20 MOhm min. between isolated circuits (at 100 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\n      \u003ctd\u003e510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNX Unit Power Consumption\u003c\/strong\u003e\n      \u003ctd\u003e0.95 W max. (when connected to CPU\/Communication Control Unit); 0.80 W max. (when connected to Communications Coupler Unit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eExternal Connection\u003c\/strong\u003e\n      \u003ctd\u003eScrewless clamping terminal block (16 terminals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\n      \u003ctd\u003e12 mm x 100 mm x 71 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.07 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor accurate and stable temperature measurements, observe the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit on a standard 35 mm DIN rail within a clean, dry, and well-ventilated control enclosure.\u003c\/li\u003e\n  \u003cli\u003eTo achieve specified accuracy, allow a minimum warm-up period of 45 minutes after powering on the system.\u003c\/li\u003e\n  \u003cli\u003eRoute thermocouple extension wires away from high-voltage AC cables, motor drives, and other electromagnetic noise sources.\u003c\/li\u003e\n  \u003cli\u003eEnsure the shielding of the thermocouple cables is correctly grounded according to local industrial electrical codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077922578795,"sku":"NX-TS2104","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-ts2104-jguk2bzphaa.png?v=1775734019","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-nx-ts2104-nx-series-temperature-input-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}