{"product_id":"omron-tp70-1s3-on-site-flexible-rod-switch","title":"Omron TP70-1S3 On-site Flexible Rod Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for rugged physical safety monitoring across processing lines and material handling corridors, the \u003cstrong\u003eOmron TP70-1S3\u003c\/strong\u003e delivers reliable mechanical tripping action combined with a separable emergency stop contact block. By utilizing a high-durability internal \u003cstrong\u003eD4N-2187\u003c\/strong\u003e microswitch, this limit assembly translates physical rod deflection into immediate control circuit interruptions. The physical design features a C-clamp base for rapid vertical alignment adjustment directly on structural framework, maintaining safe and compliant stop loops in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eBuilt-in heavy duty \u003cstrong\u003eD4N-2187\u003c\/strong\u003e contact core for reliable electrical switching.\u003c\/li\u003e\n  \u003cli\u003eSeparable emergency stop functionality for distinct safety circuit isolation.\u003c\/li\u003e\n  \u003cli\u003eFlexible rod actuator designed for multi-directional actuation and physical resilience.\u003c\/li\u003e\n  \u003cli\u003eIP65 ingress protection rating suited for moisture-exposed and dusty areas.\u003c\/li\u003e\n  \u003cli\u003eFlexible C-clamp mounting block allowing easy height adjustments along vertical mounting pillars.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eBulk conveyor belt drift and boundary control.\u003c\/li\u003e\n  \u003cli\u003eProcess line perimeter monitoring.\u003c\/li\u003e\n  \u003cli\u003eMaterial transfer station safety stops.\u003c\/li\u003e\n  \u003cli\u003eHigh-vibration material routing zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTP70-1S3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBuilt-in Switch Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eD4N-2187\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Operation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSeparable emergency-stop switch block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Integration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eC-clamp mounting with adjustable height scale\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eVibration Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMalfunction: 10 to 55 Hz, 0.65 mm single amplitude, 100 m\/s2 max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShock Resistance (Destruction)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1000 m\/s2 max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShock Resistance (Malfunction)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 m\/s2 max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 to 70 degC (non-freezing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Operating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e35% to 95% RH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAllowable Operating Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 mm\/s to 0.5 m\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMechanical Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e60 operations\/minute max.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eElectrical Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e30 operations\/minute max. (resistive load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTermination Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDevice Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.4 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eSince the assembly relies on the standard D4N-2187 core switch, physical maintenance and replacement of internal contacts can be done without modifying the external structural C-clamp or heavy mounting frame. This modular design dramatically decreases plant downtime during scheduled electrical overhauls.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAvoid using the flexible rod actuator as an hard mechanical stop for heavy machinery. Exceeding the allowable physical operating speed limit of 0.5 m\/s or subjecting the rod to direct high-velocity side impacts can result in deformation of the spring structure or early contact degradation. Verify that the ambient operating environment does not drop below -10 degC to avoid icing on the external mechanical linkages.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eWhen completing screw terminal terminations, ensure correct sealing glands are used to maintain the overall IP65 housing protection. Securely tighten the C-clamp adjustment bolts during field commissioning to ensure mechanical vibrations (up to the rated 100 m\/s2 limit) do not cause vertical shifting on the support pole.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; color: #9b2c2c; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize and lock out all upstream electrical power connections prior to opening the terminal cover of the built-in switch. Ensure zero voltage is present on all adjacent safety loop circuits before routing cables to prevent high-voltage hazard exposures or machine damage.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003ePosition and secure the C-clamp mounting block onto the designated industrial vertical post, sliding the housing vertically until the flexible rod aligns with the trip mechanism's sweep path.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eOpen the terminal cover of the D4N-2187 core and wire safety conductor lines directly to the integrated screw terminals, utilizing correct ring or spade lugs suited for heavy vibration applications.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eConfirm the sealing gasket is correctly seated, close the terminal block access panel, and complete manual stroke checks to verify both mechanical actuation and circuit state transition.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077930672491,"sku":"TP70-1S3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tp70-1s3-5ssjlwoygc1.png?v=1775734090","url":"https:\/\/www.plcprotech.com\/ru\/products\/omron-tp70-1s3-on-site-flexible-rod-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}