{"product_id":"schneider-electric-170bsm01600-modicon-momentum-digital-simulator-module","title":"Schneider Electric 170BSM01600 Modicon Momentum Digital Simulator Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned specifically for diagnostic testing and logical debugging within distributed control systems, the \u003cstrong\u003eSchneider Electric 170BSM01600\u003c\/strong\u003e is a dedicated physical simulator module configured for the Modicon Momentum product line. Operating on a nominal \u003cstrong\u003e24VDC system voltage\u003c\/strong\u003e, this module enables control engineers and field technicians to stimulate up to \u003cstrong\u003e16 digital input channels\u003c\/strong\u003e directly on the local I\/O bus without necessitating active field-side wiring. By generating physical logic-level states, the device provides a reliable feedback loop for verifying PLC configurations, network communication interfaces, and runtime control sequence logic before live process deployment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16 Simulative Inputs:\u003c\/strong\u003e Dedicated manual switch interfaces representing a full 16-point digital register block.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMomentum Bus Compatibility:\u003c\/strong\u003e Direct plug-and-play mechanical alignment with standard Modicon Momentum terminal bases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Current Footprint:\u003c\/strong\u003e Highly efficient internal logic routing optimized for low heat dissipation in enclosed testing environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Switch Actuation:\u003c\/strong\u003e Rugged, tactile input selectors built to withstand repetitive validation cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Acceptance Testing (FAT):\u003c\/strong\u003e Safe simulation of dry contacts and field sensor responses prior to system delivery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePLC Code Validation:\u003c\/strong\u003e Local testing of interlocks, alarm limits, and state machines within Schneider Modsoft, Concept, or EcoStruxure Control Expert environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Interface Audits:\u003c\/strong\u003e Network parameter mapping testing across Modbus TCP\/IP, Interbus, or PROFIBUS adapter modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOn-Site Troubleshooting:\u003c\/strong\u003e Isomorphic circuit isolation testing to rule out field-wiring faults versus controller backplane hardware issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 10px; font-weight: bold; color: #1a365d;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"border-bottom: 2px solid #2b6cb0; text-align: left; padding: 10px; font-weight: bold; color: #1a365d;\"\u003eValue \/ Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003eSchneider Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e170BSM01600\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003eModicon Momentum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003eDigital Simulator Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eSimulated Inputs\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e16 Channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eNominal System Voltage\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e24VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out (Legacy Support Active)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e85366990\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e0.17 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border-bottom: 1px solid #e2e8f0; padding: 10px;\"\u003e15.5 x 21.0 x 5.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 170BSM01600 is designed as a direct diagnostic accessory across the Modicon Momentum I\/O range. Unlike active electronic I\/O modules, the simulator module maps straight to the backplane, making it independent of specific fieldbus protocols. It maintains compatibility with standard Momentum fieldbus adapters, including Modbus TCP (170ENT11001), PROFIBUS DP (170FNT11021), and Interbus communication modules.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing this simulation module on a live commissioning desk, ensure that external loop power is completely isolated from the associated terminal base terminals to prevent potential electrical backfeeding or ground loops. The simulation switches are intended for low-power signal level processing and should not be linked to actual inductive external loads.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDe-energize the entire backplane and disconnect any active terminal base power sources prior to inserting or removing the 170BSM01600. Hot-swapping may cause diagnostic faults or communication losses on sensitive fieldbus adapters.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePower down the Modicon Momentum base unit and associated interface adapters.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eAlign the simulator guide pins with the mating slots of the Momentum base unit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePress firmly until the retention clips engage securely, preventing intermediate pin contact gaps.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eApply 24VDC system power and toggle individual simulator switches to verify corresponding PLC input register changes.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104560931179,"sku":"170BSM01600","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/170bsm01600-fdc01wln1is.png?v=1776159719","url":"https:\/\/www.plcprotech.com\/ru\/products\/schneider-electric-170bsm01600-modicon-momentum-digital-simulator-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}