{"product_id":"siemens-6av6542-0cc10-0ax0-simatic-hmi-op270-operator-panel","title":"Siemens 6AV6542-0CC10-0AX0 SIMATIC HMI OP270 Operator Panel","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6AV6542-0CC10-0AX0\u003c\/strong\u003e is an industrial-grade \u003cstrong\u003eSIMATIC OP270\u003c\/strong\u003e operator panel designed for efficient and reliable control in production environments. This unit features a \u003cstrong\u003e10.4-inch STN color display\u003c\/strong\u003e, providing clear visualization of process data and intuitive operation. Equipped with \u003cstrong\u003e2 MB of configuring memory\u003c\/strong\u003e, the \u003cstrong\u003e6AV6542-0CC10-0AX0\u003c\/strong\u003e supports flexible configuration using ProTool software from version V6.0 and higher. Its robust construction ensures consistent performance in demanding industrial settings, making it suitable for a wide range of automation applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10.4-inch STN Color Display\u003c\/li\u003e\n\u003cli\u003e2 MB (2048 kbyte) Configuring Memory\u003c\/li\u003e\n\u003cli\u003eConfigurable with ProTool Software (from V6.0)\u003c\/li\u003e\n\u003cli\u003e640 x 480 Pixel Display Resolution\u003c\/li\u003e\n\u003cli\u003e256 Display Colors\u003c\/li\u003e\n\u003cli\u003eKey-based Operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV6542-0CC10-0AX0 operator panel is suitable for deployment in various industrial automation scenarios requiring human-machine interface capabilities. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProcess visualization and control in manufacturing plants\u003c\/li\u003e\n\u003cli\u003eMachine operation and monitoring\u003c\/li\u003e\n\u003cli\u003eData entry and parameter adjustment in production lines\u003c\/li\u003e\n\u003cli\u003eSupervision of automated systems in demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC HMI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperator Panels 270 series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Product\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperator Panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eScreen Diagonal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10.4 inch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSTN Color Display\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e640 x 480 pixels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Operation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eKeys\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Colors\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e256\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConfiguring Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2048 kbyte (2 MB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e41.00 x 61.00 x 18.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6.36 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5D002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation of the Siemens 6AV6542-0CC10-0AX0 operator panel is crucial for reliable operation and system integrity. Adhere to the following general guidelines:\u003c\/p\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower De-energization:\u003c\/strong\u003e Before commencing any installation work, ensure that all power to the control cabinet or mounting location is disconnected and secured against accidental re-energization.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the operator panel securely into a prepared panel cutout. Ensure adequate clearance for ventilation and cable routing. Use appropriate mounting hardware to prevent vibration and ensure a stable fit.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24V DC supply voltage to the designated power terminals, observing correct polarity. Use shielded cables for power supply if recommended by system design to minimize electrical interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the panel's protective earth (PE) connection is properly bonded to the system's main ground. A low-impedance ground connection is essential for safety and electromagnetic compatibility.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route signal and communication cables separately from power cables to prevent interference. Ensure cables are secured, properly terminated, and do not obstruct cooling airflow.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Verify that the operating environment's temperature, humidity, and vibration levels are within the specified limits for the device to ensure long-term performance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After installation, carefully re-energize the system and observe the panel for proper startup and functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716759613803,"sku":"6AV6542-0CC10-0AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av6542-0cc10-0ax0-3vvf34yeoom_dffc781c-3450-4cb4-83d0-52acc458d6d0.jpg?v=1767088792","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av6542-0cc10-0ax0-simatic-hmi-op270-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}