{"product_id":"siemens-6av7611-0aa12-0be0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7611-0AA12-0BE0 SIMATIC Panel PC 670 Panel PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7611-0AA12-0BE0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. This standard configuration unit features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e, \u003cstrong\u003e64 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e. It is configured for a \u003cstrong\u003e115-230V AC\u003c\/strong\u003e power supply and includes a U.S. mains cable. This specific model is supplied with a pre-installed German-language version of the Windows 98 operating system. Please note that this product is considered obsolete by the manufacturer, making it suitable for maintaining or repairing legacy automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e10-inch TFT color display\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntel Pentium III 500 MHz processor\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e64 MB of installed RAM\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003e20 GB internal hard drive storage\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eWide input voltage range of 115-230V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003ePre-loaded with Windows 98 (German language)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eLegacy machine control and process visualization\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eSpare part for existing SIMATIC PC 670 installations\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eData logging and monitoring stations\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 8px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eSimple SCADA nodes in older systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 400px;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e6AV7611-0AA12-0BE0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eProduct Range\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003ePC 670\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e10-inch TFT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003ePentium III, 500 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e64 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eWindows 98 (German)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e115-230 V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e12.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eN (Not subject to export control regulations)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"padding: 10px; border-left: 1px solid #e2e8f0; border-right: 1px solid #e2e8f0;\"\u003eGermany (estimated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 20px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect and lock out all power sources to the control cabinet or mounting location. Verify the absence of voltage with a properly rated meter.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout is clean, free of burrs, and matches the PC 670's dimensions. Verify that there is adequate clearance for ventilation and cable routing behind the panel.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel gasket. Do not overtighten.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eConnect Grounding:\u003c\/strong\u003e Connect the chassis ground terminal on the Panel PC to the cabinet's protective earth (PE) bus bar using a low-impedance conductor. This is critical for safety and noise immunity.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eConnect Power and Peripherals:\u003c\/strong\u003e Connect the AC mains cable to the unit and to the power source. Connect all required communication cables (e.g., Ethernet, serial) and I\/O devices. Ensure proper cable strain relief.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove LOTO devices and re-apply power to the cabinet. Power on the Panel PC and confirm that the operating system loads correctly.\u003c\/div\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716406767979,"sku":"6AV7611-0AA12-0BE0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0aa12-0be0-p4oa54r4ymn_0b960935-067a-4856-811c-da2631d6b47b.jpg?v=1767082288","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7611-0aa12-0be0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}