{"product_id":"siemens-6av7611-0aa30-0be0-simatic-panel-pc-670","title":"Siemens 6AV7611-0AA30-0BE0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6AV7611-0AA30-0BE0 SIMATIC Panel PC 670, an industrial computer designed for panel mounting in automation environments. This standard configuration model features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003eCeleron 300 MHz CPU\u003c\/strong\u003e, \u003cstrong\u003e256 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e. It is pre-configured with a German-language version of the Windows 98 operating system and is supplied with a U.S. mains cable for a 115-230V AC power source. Please note that this product is classified by the manufacturer as obsolete, making it suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eIntegrated 10-inch color TFT display\u003c\/li\u003e\n  \u003cli\u003eCeleron processor operating at 300 MHz\u003c\/li\u003e\n  \u003cli\u003eEquipped with 256 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003eIncludes a 20 GB internal hard drive for storage\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows 98 (German language)\u003c\/li\u003e\n  \u003cli\u003eSupports a wide input voltage range of 115-230V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) for industrial machinery\u003c\/li\u003e\n  \u003cli\u003eSupervisory control and data acquisition (SCADA) nodes\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and control in manufacturing plants\u003c\/li\u003e\n  \u003cli\u003eReplacement unit for existing SIMATIC PC 670 installations\u003c\/li\u003e\n  \u003cli\u003eData logging and reporting stations on the factory floor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e6AV7611-0AA30-0BE0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e10-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e256 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWindows 98 (German)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e115-230 V AC (via supplied U.S. mains cable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eN (Not subject to control)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e40 cm x 30 cm x 15 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARD OF ELECTRIC SHOCK\u003c\/p\u003e\n  \u003cp style=\"margin-bottom: 0;\"\u003eDisconnect all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply with Lockout\/Tagout (LOTO) procedures can result in severe injury or death. Ensure the unit is properly grounded according to local and national electrical codes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Safely de-energize the control cabinet and verify the absence of voltage using a calibrated meter. Follow all site-specific LOTO procedures.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions match the PC 670's requirements. Ensure the mounting surface is clean, flat, and rigid enough to support the unit's weight.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Install and tighten the mounting clamps from the rear, applying even pressure to create a secure seal against the panel gasket. Do not overtighten.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Protective Earth:\u003c\/strong\u003e Connect a dedicated protective earth (PE) or grounding wire to the designated grounding terminal on the Panel PC chassis. This is a critical safety connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power and Peripherals:\u003c\/strong\u003e Connect the 115-230V AC mains cable to the unit's power input. Connect any required communication cables (e.g., Ethernet, serial) and I\/O devices.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eCommission and Test:\u003c\/strong\u003e Remove LOTO devices and re-energize the cabinet. Verify the Panel PC boots correctly and establishes communication with other system components. Test all HMI functions before returning the system to service.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716406571371,"sku":"6AV7611-0AA30-0BE0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0aa30-0be0-4akwijzkzs2_e5d4f766-61da-4911-9456-07515b910d32.jpg?v=1767082279","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7611-0aa30-0be0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}