{"product_id":"siemens-6av7612-0ae10-0bg0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7612-0AE10-0BG0 SIMATIC Panel PC 670 Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThis device is a Siemens 6AV7612-0AE10-0BG0 SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial control and visualization applications. It features a \u003cstrong\u003e12-inch TFT touch display\u003c\/strong\u003e and is configured with a \u003cstrong\u003e300 MHz Celeron CPU\u003c\/strong\u003e, \u003cstrong\u003e64 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e. The unit is powered by a 115-230V AC supply and is pre-installed with a multi-language version of the Windows 2000 operating system. This model is noted as an obsolete part, suitable for maintenance and replacement in existing legacy systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-inch TFT color touch display\u003c\/li\u003e\n\u003cli\u003eIntel Celeron processor operating at 300 MHz\u003c\/li\u003e\n\u003cli\u003e64 MB of installed RAM\u003c\/li\u003e\n\u003cli\u003e40 GB internal hard drive for data and application storage\u003c\/li\u003e\n\u003cli\u003eWide input voltage range of 115-230V AC\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows 2000 (Multi-language: EN, GER, FR, IT, SP)\u003c\/li\u003e\n\u003cli\u003eIncludes a U.S. mains power cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n\u003cli\u003eProcess visualization and data acquisition (SCADA)\u003c\/li\u003e\n\u003cli\u003eIndustrial data logging and reporting\u003c\/li\u003e\n\u003cli\u003eReplacement HMI for legacy automation systems\u003c\/li\u003e\n\u003cli\u003eFactory floor information terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 10px; text-align: left; background-color: #f1f5f9; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 10px; text-align: left; background-color: #f1f5f9; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e6AV7612-0AE10-0BG0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e12-inch TFT Touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eProcessor (CPU)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eWindows 2000 Multi-Language (EN, GER, FR, IT, SP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e115-230 V AC (U.S. Mains Cable included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 10px; color: #2d3748;\"\u003e35 x 28 x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n\u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARD OF ELECTRIC SHOCK\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 0;\"\u003eInstallation must be performed by qualified personnel only. Disconnect and lock out all power sources before accessing terminals or performing any installation, wiring, or maintenance. Failure to comply can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the control panel or enclosure has a clean, flat, and appropriately sized cutout for the Panel PC. Verify that the mounting surface thickness is within the specified tolerance for the mounting clips.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eInstall the Unit:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal and prevent bezel distortion.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect the chassis ground terminal to the control cabinet's protective earth bus bar using a low-impedance conductor. This is critical for both safety and noise immunity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e With the main power source de-energized, connect the provided 115-230V AC mains cable to the unit's power input connector. Ensure the source voltage matches the device's rating.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003eConnect Peripherals and Network:\u003c\/strong\u003e Connect any required communication cables (e.g., Ethernet, serial) and peripherals (e.g., keyboard, mouse). Route all cables away from high-voltage lines to minimize electrical noise interference.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e6\u003c\/span\u003e\n\u003cspan style=\"flex-grow: 1;\"\u003e\u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e After verifying all connections are secure and correct, remove the lockout\/tagout and re-energize the main power source. Power on the Panel PC and confirm that the operating system boots correctly and the touch display is responsive.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715837620587,"sku":"6AV7612-0AE10-0BG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7612-0ae10-0bg0-dp0ybk45dob_34f0003d-631c-48b5-8429-2499719abbff.jpg?v=1767072203","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7612-0ae10-0bg0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}