{"product_id":"siemens-6av7613-2db22-0ch0-simatic-panel-pc-670","title":"Siemens 6AV7613-2DB22-0CH0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6AV7613-2DB22-0CH0 is a Panel PC from the SIMATIC PC 670 series, designed for human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e and is powered by an Intel \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e. It is equipped with \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e for data storage and application hosting. The system comes pre-installed with the \u003cstrong\u003eWindows NT 4.0 German\u003c\/strong\u003e operating system and includes a ProTool\/Pro Runtime license supporting up to \u003cstrong\u003e2048 Power Tags\u003c\/strong\u003e. This configuration is intended for legacy system maintenance and support, operating on a 115-230V AC power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        12-inch TFT color display for process visualization.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Intel Pentium III processor operating at 500 MHz.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        128 MB of system RAM.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        20 GB hard drive and integrated CD-ROM drive.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Pre-installed Windows NT 4.0 operating system (German language).\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Includes ProTool\/Pro Runtime License for up to 2048 Power Tags.\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Legacy machine control and process visualization.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Plant-floor data acquisition and monitoring systems.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Direct replacement for existing SIMATIC PC 670 installations.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0; border-radius: 50%;\"\u003e\u003c\/span\u003e\n        Small-scale SCADA nodes in industrial environments.\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6AV7613-2DB22-0CH0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12-inch TFT\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCPU\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePentium III, 500 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRAM\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e128 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e20 GB Hard Drive, CD-ROM Drive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows NT 4.0 (German)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded License\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProTool\/Pro Runtime\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eLicense Limit\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2048 Power Tags\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eInput Voltage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e115-230 V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded Cable\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARD OF ELECTRIC SHOCK\u003c\/p\u003e\n    \u003cp style=\"color: #2d3748; margin-bottom: 0;\"\u003eAll installation and maintenance procedures must be performed by qualified personnel only. Ensure the control cabinet is completely de-energized and locked out\/tagged out (LOTO) before beginning any work. Failure to disconnect power can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; color: #2d3748;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n        Prepare the panel cutout according to the device's mechanical specifications. Verify dimensions and ensure the mounting surface is clean, flat, and rigid.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; color: #2d3748;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n        Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; color: #2d3748;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n        Connect a dedicated protective earth (PE) or grounding conductor to the designated terminal on the PC chassis. This connection is critical for safety and noise immunity.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; color: #2d3748;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n        Connect the 115-230V AC power supply using the provided mains cable to a properly rated and protected circuit. Ensure all communication and I\/O cables are routed away from high-voltage lines to minimize interference.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 16px; color: #2d3748;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n        After verifying all connections, remove the LOTO device and re-energize the cabinet. Power on the Panel PC and confirm that the operating system boots correctly.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715810816363,"sku":"6AV7613-2DB22-0CH0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-2db22-0ch0-fhk4lct3wuz_eeefe839-6925-4615-9bf6-654a04e75708.jpg?v=1767071475","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7613-2db22-0ch0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}