{"product_id":"siemens-6av7614-0af20-0bg0-simatic-panel-pc-670","title":"Siemens 6AV7614-0AF20-0BG0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7614-0AF20-0BG0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. This unit features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e and is powered by a \u003cstrong\u003e300 MHz Celeron processor\u003c\/strong\u003e with \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e. For data storage and software installation, it includes a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e and an integrated \u003cstrong\u003eCD-ROM drive\u003c\/strong\u003e. The system comes pre-installed with the Windows 2000 multi-language operating system and is configured for a 115-230V AC power supply, including a U.S. mains cable. Note that this product is considered obsolete by the manufacturer, which may impact support and availability of replacement parts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003e15-inch TFT color display with integrated touch screen\u003c\/li\u003e\n  \u003cli\u003eIntel Celeron processor operating at 300 MHz\u003c\/li\u003e\n  \u003cli\u003e128 MB of system RAM\u003c\/li\u003e\n  \u003cli\u003e40 GB internal hard drive for OS and application storage\u003c\/li\u003e\n  \u003cli\u003eBuilt-in CD-ROM drive for software installation\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Windows 2000 (Multi-language support for English, German, French, Italian, Spanish)\u003c\/li\u003e\n  \u003cli\u003eWide-range power supply compatibility (115-230V AC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and data acquisition (SCADA)\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and recipe management\u003c\/li\u003e\n  \u003cli\u003eFactory automation control panels\u003c\/li\u003e\n  \u003cli\u003eLegacy system replacement or maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6AV7614-0AF20-0BG0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e15-inch TFT Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWindows 2000 Multi-language (EN, GER, FR, IT, SP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e115-230V AC (Supplied with U.S. mains cable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e This is an obsolete electronic device. Installation should only be performed by qualified personnel familiar with legacy automation systems. Ensure compatibility with existing infrastructure before integration. Risk of data loss or system incompatibility exists.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely de-energize the control panel or machine. Follow all local Lockout\/Tagout (LOTO) procedures to prevent accidental power-up. Verify zero energy state with a calibrated multimeter.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Ensure the panel cutout dimensions match the PC 670's physical requirements. Secure the unit using all provided mounting clamps to ensure a proper seal and stable installation. Verify that the mounting surface is flat and can support the unit's weight.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eProtective Earth Connection:\u003c\/strong\u003e Connect the protective earth (PE) terminal on the Panel PC chassis to the main system ground. Use a low-impedance conductor of appropriate gauge to ensure operator safety and reduce electromagnetic interference.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePower and I\/O Wiring:\u003c\/strong\u003e Connect the AC power supply using the provided cable. Route all communication and I\/O cables away from high-voltage lines to minimize noise. Ensure all cable connectors are fully seated and secured.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and confirm that the Windows 2000 operating system boots correctly. Proceed with software configuration and system checks.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715885822315,"sku":"6AV7614-0AF20-0BG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0af20-0bg0-dce4vw50tii_fff35e60-9f69-4f25-9ae3-aee27b912d71.jpg?v=1767073835","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7614-0af20-0bg0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}