{"product_id":"siemens-6av7724-3ba20-0af0-simatic-panel-pc-670","title":"Siemens 6AV7724-3BA20-0AF0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"border-bottom: 2px solid #1a365d; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a SIMATIC Panel PC 670, model 6AV7724-3BA20-0AF0, from Siemens, designed for human-machine interface (HMI) applications in industrial environments. This standard configuration unit features a \u003cstrong\u003e15.1-inch color TFT touchscreen\u003c\/strong\u003e display, powered by a \u003cstrong\u003ePentium III 1.26 GHz\u003c\/strong\u003e processor. It is equipped with \u003cstrong\u003e512 MB of SDRAM\u003c\/strong\u003e and an \u003cstrong\u003e80 GB EIDE hard drive\u003c\/strong\u003e. The system operates on a \u003cstrong\u003e24V DC\u003c\/strong\u003e power supply and comes pre-installed with the Windows 98 SE operating system in English. Please note, this model is classified as an obsolete product, making it suitable for maintaining or repairing legacy automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #1a365d; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003e15.1-inch Color TFT display with integrated touch functionality\u003c\/li\u003e\n\u003cli\u003ePentium III processor operating at 1.26 GHz\u003c\/li\u003e\n\u003cli\u003e512 MB SDRAM-133 configured as two 256 MB modules\u003c\/li\u003e\n\u003cli\u003e80 GB EIDE internal hard disk drive for storage\u003c\/li\u003e\n\u003cli\u003eIntegrated power supply unit for 24V DC input\u003c\/li\u003e\n\u003cli\u003ePre-loaded with Windows 98 SE (English version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #1a365d; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n\u003cli\u003eLegacy system maintenance and spare parts replacement\u003c\/li\u003e\n\u003cli\u003eProcess visualization and control\u003c\/li\u003e\n\u003cli\u003eMachine-level data acquisition and logging\u003c\/li\u003e\n\u003cli\u003eOperator control stations in manufacturing and production lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #1a365d; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 8px; text-align: left; background-color: #f2f2f2;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 8px; text-align: left; background-color: #f2f2f2;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e6AV7724-3BA20-0AF0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e15.1-inch Color TFT, Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003ePentium III, 1.26 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e512 MB SDRAM-133 (2x 256MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e80 GB HDD EIDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eWindows 98 SE, English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e12.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e48.00 x 29.00 x 15.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eN (No License Required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 8px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #1a365d; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Risk of electric shock. Installation must be performed by qualified personnel only. Ensure all power sources to the cabinet are de-energized and locked out\/tagged out (LOTO) before beginning work. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eVerify Panel Cutout:\u003c\/strong\u003e Before installation, confirm that the mounting cutout in the control cabinet or panel matches the required dimensions for the Panel PC 670. Ensure the mounting surface is clean, flat, and free of debris.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Carefully insert the Panel PC into the cutout from the front. Secure the unit from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a diagonal pattern to ensure a uniform seal against the panel gasket. Do not overtighten.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect a low-impedance protective earth conductor to the designated PE terminal on the unit's chassis. This connection is critical for operator safety and electromagnetic compatibility (EMC).\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the 24V DC power source to the power supply input terminals. Verify correct polarity (+\/-) before connection. Use appropriately sized conductors and ensure the power source is stable and within the specified voltage range.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect any required communication cables (e.g., Ethernet, serial) and I\/O devices. Ensure all connectors are fully seated and secured. Route cables neatly and away from sources of high electrical noise.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFinal Check and Power-Up:\u003c\/strong\u003e After all connections are made, perform a final inspection. Remove LOTO devices and re-energize the main cabinet power. The Panel PC should boot up automatically. Verify system operation and touchscreen functionality.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715867373931,"sku":"6AV7724-3BA20-0AF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7724-3ba20-0af0-tfqvghyij1l_8c0f3b5b-6866-4cb2-a1bc-66f77583a288.jpg?v=1767073259","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7724-3ba20-0af0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}