{"product_id":"siemens-6av7872-0ba20-1ac0-simatic-panel-pc-677b-panel-pc","title":"Siemens 6AV7872-0BA20-1AC0 SIMATIC Panel PC 677B Panel PC","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis Siemens 6AV7872-0BA20-1AC0 is a SIMATIC Panel PC 677B, an industrial-grade computer designed for process control, visualization, and data acquisition in demanding factory environments. It is equipped with a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e and powered by an \u003cstrong\u003eIntel Celeron M440 1.86 GHz processor\u003c\/strong\u003e. The system includes \u003cstrong\u003e1 GB of DDR2 RAM\u003c\/strong\u003e and a \u003cstrong\u003e160 GB SATA hard disk drive\u003c\/strong\u003e for reliable performance and data storage. Extensive connectivity is provided through dual Gigabit Ethernet ports, multiple USB 2.0 interfaces, a serial port, and a PROFIBUS\/MPI connection, facilitating straightforward integration into existing automation architectures. The unit also features two PCI slots for future expansion.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n    \u003cli\u003e15-inch touch display with 1024 x 768 resolution\u003c\/li\u003e\n    \u003cli\u003eIntel Celeron M440 processor operating at 1.86 GHz\u003c\/li\u003e\n    \u003cli\u003e1 GB DDR2 RAM for application processing\u003c\/li\u003e\n    \u003cli\u003e160 GB 3.5-inch SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n    \u003cli\u003eIntegrated DVD+-R+-RW optical drive\u003c\/li\u003e\n    \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n    \u003cli\u003ePROFIBUS\/MPI interface for fieldbus communication\u003c\/li\u003e\n    \u003cli\u003eFour rear USB 2.0 ports and one front-side USB port\u003c\/li\u003e\n    \u003cli\u003eTwo PCI slots for hardware expansion\u003c\/li\u003e\n    \u003cli\u003ePre-installed with Windows XP Professional MUI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) for machinery control\u003c\/li\u003e\n    \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) systems\u003c\/li\u003e\n    \u003cli\u003eProcess visualization and monitoring stations\u003c\/li\u003e\n    \u003cli\u003eFactory floor data logging and analysis\u003c\/li\u003e\n    \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Panel PC 677B\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15-inch Touch Screen\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Celeron M440, 1.86 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCache\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 MB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 GB DDR2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eBuffered Memory\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 MB Buffered SRAM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e160 GB SATA HDD (3.5-inch)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUSB Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4 x USB 2.0 (rear), 1 x USB (front)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSerial Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1 x COM1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eFieldbus Interface\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFIBUS\/MPI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x PCI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e110\/230 V AC, NAMUR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e17.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e60.00 x 56.50 x 30.00 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; border-left: 4px solid #c53030; background-color: #fff5f5; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect and lock out all power sources before installation or servicing. Work must be performed by qualified personnel only. Failure to comply can result in severe injury or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        Ensure the mounting panel cutout dimensions are correct and the surface is clean, flat, and capable of supporting the unit's weight (17.00 kg).\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        Insert the Panel PC into the cutout from the front. Secure it using all provided mounting clamps, tightening them evenly to ensure a proper seal and prevent chassis distortion.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        Connect the protective earth (PE) conductor to the designated grounding terminal on the chassis. A low-impedance ground connection is essential for safety and noise immunity.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        Connect the 110\/230 V AC power supply cable to the unit's power input. Ensure the source voltage matches the specified range. Do not apply power at this stage.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        Connect all required communication cables (Ethernet, PROFIBUS, USB, Serial) to their respective ports. Ensure proper shielding and termination as required by the protocol standards.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        After verifying all connections are secure and correct, remove the lockout\/tagout device and apply power to the unit for commissioning.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715876581739,"sku":"6AV7872-0BA20-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-0ba20-1ac0-j2figc0mtxz_b6bcc70e-17e3-4029-b7d6-0140fc9d10df.jpg?v=1767073471","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7872-0ba20-1ac0-simatic-panel-pc-677b-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}