{"product_id":"siemens-6av7892-0eb00-1ab0-simatic-ipc677c-panel-pc","title":"Siemens 6AV7892-0EB00-1AB0 SIMATIC IPC677C Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6AV7892-0EB00-1AB0, a SIMATIC HMI IPC677C Panel PC designed for industrial human-machine interface and control applications. It features a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e with a resolution of \u003cstrong\u003e1024x768\u003c\/strong\u003e and is powered by an Intel \u003cstrong\u003eCeleron P4505 processor\u003c\/strong\u003e. The unit is equipped with \u003cstrong\u003e1 GB of DDR3 RAM\u003c\/strong\u003e, a \u003cstrong\u003e250 GB SATA HDD\u003c\/strong\u003e, and an integrated DVD drive. For connectivity, it provides dual Gigabit Ethernet ports, multiple USB 2.0 interfaces, a serial port, and a \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. Integrated monitoring for watchdog, temperature, and fan status, along with an onboard RAID controller, ensures operational reliability.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003e15-inch color touchscreen display with 1024 x 768 resolution.\u003c\/li\u003e\n\u003cli\u003eConvenient front-side USB interface for easy access.\u003c\/li\u003e\n\u003cli\u003eIntegrated system monitoring for watchdog, temperature, and fan.\u003c\/li\u003e\n\u003cli\u003eOnboard RAID controller for data redundancy.\u003c\/li\u003e\n\u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network communication.\u003c\/li\u003e\n\u003cli\u003ePROFIBUS\/MPI interface (CP 5611-A2 compatible) for field-level integration.\u003c\/li\u003e\n\u003cli\u003ePre-installed with Windows XP Professional SP3 MUI.\u003c\/li\u003e\n\u003cli\u003eTwo free PCI slots available for expansion cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eProcess visualization and control in manufacturing plants.\u003c\/li\u003e\n\u003cli\u003eMachine-level HMI for OEM equipment.\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging in industrial environments.\u003c\/li\u003e\n\u003cli\u003eSupervisory control systems in assembly lines and production cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7892-0EB00-1AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC HMI IPC677C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e15\" Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCeleron P4505 (2C\/2T, 1.86 GHz, 2 MB Cache)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1 GB DDR3 1066 DIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBuffered SRAM\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e250 GB HDD SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDVD±R\/±RW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e110\/230 V AC with NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4x USB V2.0 (rear), 1x USB (front)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSerial Port\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1x COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eFieldbus Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFIBUS\/MPI (CP 5611-A2 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x PCI (free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWindows XP Professional SP3 MUI (DE, EN, FR, ES, IT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e17.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e67.0 x 55.0 x 28.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0; color: #c53030; font-weight: bold;\"\u003eCRITICAL WARNING: HAZARDOUS VOLTAGE\u003c\/p\u003e\n\u003cp style=\"margin-top: 8px; margin-bottom: 0; color: #2d3748;\"\u003eThis equipment is powered by hazardous AC voltage. All installation and maintenance procedures must be performed by qualified personnel only. Failure to de-energize and lock-out\/tag-out the power source before servicing can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eVerify panel cutout dimensions against the device specifications to ensure a proper fit. Deburr all sharp edges on the cutout.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eEnsure adequate ventilation clearance around the rear of the unit for heat dissipation. Do not block fan vents.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eInsert the Panel PC into the cutout and secure it evenly using all provided mounting clamps. Tighten clamps progressively to the specified torque to ensure a proper seal.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eConnect the protective earth (PE) terminal to the cabinet's main ground point using a low-impedance conductor. This connection must be made first.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eConnect power, network, and I\/O cables. Ensure all connectors are fully seated and secured. Use shielded cables for communication lines and ground the shields appropriately.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px; counter-increment: step-counter;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cspan style=\"color: #2d3748;\"\u003eBefore applying power, verify that the source voltage matches the rating specified on the unit's nameplate (110\/230 V AC).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715855249771,"sku":"6AV7892-0EB00-1AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7892-0eb00-1ab0-claqqqao4ii_d0af0455-345a-4e98-ba81-b6e40e45a4a1.jpg?v=1767072811","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6av7892-0eb00-1ab0-simatic-ipc677c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}