{"product_id":"siemens-6es7193-4ce10-0aa0-simatic-et-200sp-terminal-block","title":"Siemens 6ES7193-4CE10-0AA0 SIMATIC ET 200SP Terminal Block","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis is a Siemens 6ES7193-4CE10-0AA0 terminal block, a high-density front connector engineered for the SIMATIC ET 200SP distributed I\/O system. It is designed to manage a significant number of field device connections with its \u003cstrong\u003e40-pin\u003c\/strong\u003e configuration, making it an ideal component for complex automation tasks where control cabinet space is limited. The module features an innovative \u003cstrong\u003epush-in termination technology\u003c\/strong\u003e, which permits rapid, tool-free wiring to accelerate installation and simplify maintenance. By consolidating numerous connections into a single compact unit, this terminal block enables a cleaner, more organized cabinet layout and ensures reliable signal integrity for all connected devices.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eEngineered for the Siemens SIMATIC ET 200SP distributed I\/O system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eHigh-density 40-pin front connector configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eFeatures tool-free push-in termination for fast and secure wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eCompact design optimizes space within control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eFacilitates efficient system commissioning and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eIndustrial Automation Systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eProcess Control and Monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eManufacturing and Assembly Lines\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eBuilding Management Systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #2b6cb0;\"\u003e■\u003c\/span\u003eDistributed Control Systems (DCS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003ePart Number\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003e6ES7193-4CE10-0AA0\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eProduct Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003eTerminal Block for Power Modules\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eSeries\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003eSIMATIC ET 200SP\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003ePin Count\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003e40\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eTermination Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003ePush-in\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003e0.95 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003eGermany\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eHarmonized System (HS) Code\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003e8537101190\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 8px; font-weight: bold; background-color: #f7fafc;\"\u003eCondition\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 8px;\"\u003eNew\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Installation, modification, or removal of this device must be performed only by qualified electrical personnel. Always de-energize the entire system and implement Lockout\/Tagout (LOTO) procedures before accessing any components. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    Verify that all power sources to the control cabinet and the ET 200SP station are de-energized and locked out.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    Align the terminal block with the corresponding ET 200SP BaseUnit. Ensure correct orientation before firmly pressing it into place until it audibly clicks and is securely seated.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    Prepare field wiring by stripping the insulation to the manufacturer-specified length. Ensure no stray strands are present. Use of ferrules is recommended for stranded conductors.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    Insert each prepared wire into its designated push-in terminal. The spring-loaded mechanism will automatically clamp the conductor.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n    Gently tug on each wire to confirm it is securely terminated. A proper connection will resist light pulling force.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; position: relative; padding-left: 40px; color: #2d3748;\"\u003e\n    \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e6\u003c\/span\u003e\n    After all connections are verified, remove LOTO devices and follow standard procedures to re-energize the system for functional testing.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695216980331,"sku":"6ES7193-4CE10-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7193-4ce10-0aa0-terminal-block-for-power-modules-htp5y4h4ucb_93d01bbd-432b-4b13-8d75-3e771cca9927.jpg?v=1766130975","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7193-4ce10-0aa0-simatic-et-200sp-terminal-block","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}