{"product_id":"siemens-6es7417-4xl00-0ab0-simatic-s7-400-cpu-module","title":"Siemens 6ES7417-4XL00-0AB0 SIMATIC S7-400 CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6ES7417-4XL00-0AB0\u003c\/strong\u003e is a SIMATIC S7-400 CPU 417-4 central processing unit designed for robust performance in industrial automation environments. This CPU module features \u003cstrong\u003e4 MB of work memory\u003c\/strong\u003e, allocated as 2 MB for program code and 2 MB for data, providing ample capacity for complex process control tasks. It integrates a built-in \u003cstrong\u003eMPI interface\u003c\/strong\u003e supporting communication speeds up to 12 Mbit\/s, alongside a \u003cstrong\u003ePROFIBUS DP interface\u003c\/strong\u003e. Further connectivity is facilitated by a dedicated 3rd\/4th interface plug-in IFM module, ensuring straightforward integration into diverse production systems. The \u003cstrong\u003e6ES7417-4XL00-0AB0\u003c\/strong\u003e is engineered for dependable and scalable control solutions, contributing to operational efficiency in continuous production processes.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSIMATIC S7-400 CPU 417-4\u003c\/li\u003e\n  \u003cli\u003e4 MB work memory (2 MB code, 2 MB data)\u003c\/li\u003e\n  \u003cli\u003e1 MPI interface with 12 Mbit\/s communication speed\u003c\/li\u003e\n  \u003cli\u003e1 PROFIBUS DP interface\u003c\/li\u003e\n  \u003cli\u003eSupports 3rd\/4th interface plug-in IFM module\u003c\/li\u003e\n  \u003cli\u003eDesigned for industrial automation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens 6ES7417-4XL00-0AB0 CPU is suitable for a wide range of industrial applications requiring high-performance control, including:\n\u003cul\u003e\n  \u003cli\u003eComplex process control systems\u003c\/li\u003e\n  \u003cli\u003eLarge-scale manufacturing and production lines\u003c\/li\u003e\n  \u003cli\u003eDistributed automation architectures\u003c\/li\u003e\n  \u003cli\u003eSystems requiring robust and scalable control solutions\u003c\/li\u003e\n  \u003cli\u003eIntegration into existing SIMATIC S7-400 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic S7\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eS7-400\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard CPUs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLC Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModular\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWork Memory (Total)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWork Memory (Code)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWork Memory (Data)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMPI Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 (12 Mbit\/s)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS DP Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAdditional Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3rd\/4th interface plug-in IFM module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5.10 x 29.20 x 21.60 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper installation of the Siemens SIMATIC S7-400 CPU module is crucial for reliable operation. Follow these general guidelines:\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the S7-400 rack and associated components is disconnected before installation or removal of any module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Carefully slide the CPU module into the designated slot in the S7-400 rack until it clicks securely into place. Ensure proper alignment with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect communication cables (MPI, PROFIBUS DP) to their respective ports. Ensure correct polarity and secure termination for all connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the S7-400 rack and all connected components are properly grounded to minimize electrical noise and ensure safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower-Up:\u003c\/strong\u003e After all modules are securely installed and wired, restore power to the system. Observe status indicators on the CPU for correct operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize appropriate Siemens engineering software (e.g., STEP 7) to configure the CPU, memory, and communication interfaces according to the application requirements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716777439595,"sku":"6ES7417-4XL00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7417-4xl00-0ab0-vgo1xcvbjyi_c8773016-5891-4868-9476-366d3dc5e8d9.jpg?v=1767089417","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7417-4xl00-0ab0-simatic-s7-400-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}