{"product_id":"siemens-6es7516-3an00-0ab0-simatic-s7-1500-cpu-1516-3-pn-dp","title":"Siemens 6ES7516-3AN00-0AB0 SIMATIC S7-1500 CPU 1516-3 PN\/DP","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7516-3AN00-0AB0 is a central processing unit from the SIMATIC S7-1500 series, designed for complex automation and process control applications. This CPU 1516-3 PN\/DP module features a work memory of \u003cstrong\u003e1 MB for program\u003c\/strong\u003e and \u003cstrong\u003e5 MB for data\u003c\/strong\u003e, enabling it to handle extensive logic and data sets. With a bit processing performance of \u003cstrong\u003e10 ns\u003c\/strong\u003e, it ensures high-speed execution for time-critical tasks. The unit is equipped with three distinct communication interfaces: a primary PROFINET IRT interface with an integrated 2-port switch, a secondary Ethernet interface, and a PROFIBUS DP interface for versatile network integration. Operation of this CPU requires a SIMATIC Memory Card, which is not included.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e1 MB work memory for program execution.\u003c\/li\u003e\n  \u003cli\u003e5 MB work memory for data storage.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed 10 ns bit processing performance.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFINET IRT interface with a 2-port switch for line topologies.\u003c\/li\u003e\n  \u003cli\u003eAdditional dedicated Ethernet interface for network separation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP master\/slave interface for legacy device communication.\u003c\/li\u003e\n  \u003cli\u003eRequires a SIMATIC Memory Card for operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMedium to high-complexity machine control.\u003c\/li\u003e\n  \u003cli\u003eFactory and manufacturing automation.\u003c\/li\u003e\n  \u003cli\u003eProcess control systems requiring multiple network protocols.\u003c\/li\u003e\n  \u003cli\u003eApplications demanding high-speed data processing and communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Family\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC S7-1500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6ES7516-3AN00-0AB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCentral Processing Unit (CPU 1516-3 PN\/DP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWork Memory (Program)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWork Memory (Data)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e5 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBit Performance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e10 ns\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e19.2 - 28.8 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInterface 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePROFINET IRT with 2-port switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInterface 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEthernet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInterface 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePROFIBUS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRequired Memory Card\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC Memory Card (not included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e7.00 cm x 12.90 cm x 14.70 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Failure to de-energize equipment before installation can result in electric shock, equipment damage, or personal injury. Always follow local Lockout\/Tagout (LOTO) procedures. Installation must be performed by qualified personnel only.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect and lock out the main power supply to the control cabinet to prevent accidental startup. Verify the absence of voltage with a calibrated multimeter.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eMount CPU:\u003c\/strong\u003e Securely mount the CPU module onto the S7-1500 system mounting rail inside the control panel. Ensure it is properly seated and the locking mechanism engages with adjacent modules.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect a stable, correctly rated 24 VDC power supply to the designated power terminals on the module. Verify polarity before connecting. Ensure the power supply is properly grounded.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eTerminate Network Cables:\u003c\/strong\u003e Connect the PROFINET, Ethernet, and PROFIBUS cables to their respective ports. Use shielded, industrial-grade cabling and ensure proper shield grounding to minimize electrical noise interference.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eInsert Memory Card:\u003c\/strong\u003e Before applying power, insert a compatible SIMATIC Memory Card into the designated slot on the CPU. The CPU will not operate without a memory card.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSystem Commissioning:\u003c\/strong\u003e After verifying all connections, remove the lockout\/tagout and re-apply power to the control cabinet. Proceed with system commissioning and program download via your engineering software.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716376031595,"sku":"6ES7516-3AN00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7516-3an00-0ab0-vetofq5evlo_9aac0c40-8ef3-4e28-aa2f-01ac3fb29130.jpg?v=1767081615","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7516-3an00-0ab0-simatic-s7-1500-cpu-1516-3-pn-dp","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}