{"product_id":"siemens-6es7647-6ch66-0ga1-simatic-ipc627c-box-pc","title":"Siemens 6ES7647-6CH66-0GA1 SIMATIC IPC627C Box PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6ES7647-6CH66-0GA1, a SIMATIC IPC627C series Box PC engineered for robust performance in demanding industrial environments. This unit is equipped with an \u003cstrong\u003eIntel Core i7-610E processor\u003c\/strong\u003e, \u003cstrong\u003e4 GB of DDR3 ECC memory\u003c\/strong\u003e, and a redundant storage configuration with \u003cstrong\u003etwo 320 GB SATA drives in a RAID1 array\u003c\/strong\u003e. It features extensive connectivity options including dual Gigabit Ethernet, USB 2.0, and a \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. The system operates on a \u003cstrong\u003e24 V DC industrial power supply\u003c\/strong\u003e and includes integrated monitoring for temperature and fan status to ensure high availability.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003ePowered by an Intel Core i7-610E dual-core processor with Hyper-Threading.\u003c\/li\u003e\n  \u003cli\u003eOnboard HD graphics for visualization tasks.\u003c\/li\u003e\n  \u003cli\u003eIntegrated RAID controller for data redundancy.\u003c\/li\u003e\n  \u003cli\u003eFeatures a front-accessible CompactFlash drive slot.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in watchdog timer and hardware monitoring for temperature and fan speed.\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows XP Professional SP3 (Multi-language User Interface).\u003c\/li\u003e\n  \u003cli\u003eIncludes SIMATIC IPC DiagMonitor V4.5 software for system diagnostics.\u003c\/li\u003e\n  \u003cli\u003eCP 5611-A2 compatible PROFIBUS\/MPI communication port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eMachine control and automation\u003c\/li\u003e\n  \u003cli\u003eProcess visualization (HMI\/SCADA)\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging\u003c\/li\u003e\n  \u003cli\u003eIndustrial gateways and communication servers\u003c\/li\u003e\n  \u003cli\u003eQuality assurance and inspection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ddd; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; border: 1px solid #ddd; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSIMATIC IPC627C (Box PC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIntel Core i7-610E (2 Cores \/ 4 Threads, 2.53 GHz, 4 MB Cache, TB, HT, VT, AMT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eMemory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e4 GB DDR3 1066 DIMM, ECC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBuffered SRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eRAID1, 2x 320 GB SATA (2.5\")\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eGraphics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eHD Graphic Onboard\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s Ethernet RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (High Current)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e1x COM1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIndustrial Bus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MPI (CP 5611-A2-compatible)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e2x PCI (Free)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e24 V DC Industrial Power Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWindows XP Professional SP3 MUI (DE, EN, FR, ES, IT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eMonitoring Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eWatchdog, Temperature\/Fan Monitoring\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e6.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ddd; background-color: #fafafa;\"\u003e80.8 x 11.1 x 19.2 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 20px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or servicing to prevent electric shock and equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eSecurely mount the Box PC inside a suitable industrial enclosure that provides protection against environmental factors and ensures adequate ventilation. Maintain specified clearance around the unit for airflow.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the chassis to a verified protective earth (PE) ground using the designated grounding terminal. A low-impedance ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eTerminate the 24 V DC power supply wiring to the correct terminals. Verify voltage and polarity before connecting. Use appropriately sized conductors and ensure connections are secure.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect all required peripheral, network (Ethernet, PROFIBUS\/MPI), and I\/O cables. Ensure proper cable shielding and routing to minimize electromagnetic interference.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eAfter verifying all connections are correct and secure, remove the lockout\/tagout device and apply power to the unit. Proceed with system commissioning and software configuration.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716477645163,"sku":"6ES7647-6CH66-0GA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6ch66-0ga1-weej15dm3ky_7f159c40-db0e-4f28-9694-e0ff70700636.jpg?v=1767083294","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7647-6ch66-0ga1-simatic-ipc627c-box-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}