{"product_id":"siemens-6es7647-7ak20-0ra0-simatic-microbox-pc-427b","title":"Siemens 6ES7647-7AK20-0RA0 SIMATIC Microbox PC 427B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7647-7AK20-0RA0\u003c\/strong\u003e is a SIMATIC Microbox PC 427B, designed for industrial automation applications. This compact industrial PC features a \u003cstrong\u003ePentium M 1.4 GHz processor\u003c\/strong\u003e with a 400 MHz Front Side Bus (FSB) and 2 MB Second Level Cache (SLC). It is equipped with \u003cstrong\u003e512 MByte DDR2 533 SODIMM memory\u003c\/strong\u003e (1 x 512 MB) and includes a \u003cstrong\u003e4 GB Compact-Flash drive\u003c\/strong\u003e that is replaceable and accessible. The unit comes with \u003cstrong\u003eWindows XP Embedded preinstalled\u003c\/strong\u003e and supports PROFIBUS DP 12 for industrial communication, making it suitable for various control and data processing tasks in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eProcessor: Pentium M 1.4 GHz, 400 MHz FSB, 2 MB SLC\u003c\/li\u003e\n    \u003cli\u003eMemory: 512 MByte DDR2 533 SODIMM (1 x 512 MB)\u003c\/li\u003e\n    \u003cli\u003eStorage: 4 GB Compact-Flash (replaceable, accessible)\u003c\/li\u003e\n    \u003cli\u003eOperating System: Windows XP Embedded (preinstalled)\u003c\/li\u003e\n    \u003cli\u003eCommunication: PROFIBUS DP 12\u003c\/li\u003e\n    \u003cli\u003eHardware Extension: Without HW Extension\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe SIMATIC Microbox PC 427B is typically deployed in industrial settings requiring a robust and compact computing platform. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eMachine control and visualization (HMI)\u003c\/li\u003e\n    \u003cli\u003eData acquisition and processing\u003c\/li\u003e\n    \u003cli\u003eDistributed control systems (DCS)\u003c\/li\u003e\n    \u003cli\u003eEmbedded control solutions\u003c\/li\u003e\n    \u003cli\u003eIndustrial communication gateways\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Box PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC427B\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC Microbox\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePentium M 1.4 GHz, 400 MHz FSB, 2 MB SLC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMemory Extension\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e512 MByte DDR2 533 SODIMM (1 x 512 MB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHardware Extension\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout HW Extension\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDrives\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 GB Compact-Flash (replaceable, accessible)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Embedded (preinstalled)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS DP 12\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e40.50 x 22.00 x 26.40 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.60 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and associated equipment is disconnected and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Microbox PC in a suitable industrial enclosure or control cabinet, ensuring adequate ventilation and clearance for cable routing and maintenance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the industrial power supply according to the specified voltage and current requirements. Verify correct polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a robust protective earth (PE) connection to the chassis of the Microbox PC to ensure safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS DP Connection:\u003c\/strong\u003e Connect the PROFIBUS DP cable to the designated interface. Ensure proper termination and shielding for reliable communication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any necessary peripherals (e.g., display, keyboard, mouse) as required for the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables to minimize stress on connectors and to separate power cables from signal cables to prevent interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Confirm the operating environment (temperature, humidity, vibration) is within the specified limits for the device.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e Once all connections are verified, re-energize the system and observe for proper boot-up and operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716368953707,"sku":"6ES7647-7AK20-0RA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-7ak20-0ra0-egszmypywfh_245968be-bebb-4249-a116-9c547c3c49b2.jpg?v=1767081446","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7647-7ak20-0ra0-simatic-microbox-pc-427b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}