{"product_id":"siemens-6es7660-0dc13-2ba0-simatic-ipc547c-industrial-workstation","title":"Siemens 6ES7660-0DC13-2BA0 SIMATIC IPC547C Industrial Workstation","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7660-0DC13-2BA0 is a SIMATIC IPC547C industrial workstation designed for use as an OS Server within a SIMATIC PCS7 environment. This unit is equipped with an \u003cstrong\u003eIntel Core 2 Duo E8400 processor\u003c\/strong\u003e, \u003cstrong\u003e2.0 GB of DDR2 SDRAM\u003c\/strong\u003e, and a redundant storage configuration. It comes pre-installed with SIMATIC PCS7 V7.1 SP3 software on a Windows Server 2003 Standard Edition operating system, making it a ready-to-deploy component for process control applications. The system includes an industrial-grade power supply and a European power cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003eProcessor: Intel Core 2 Duo E8400 (3.0 GHz, 1333 MHz FSB, 6 MB L2 Cache)\u003c\/li\u003e\n  \u003cli\u003eMemory: 2.0 GB DDR2 SDRAM (configured as 2 x 1.0 GB modules)\u003c\/li\u003e\n  \u003cli\u003eStorage: RAID1 configuration with two 250 GB SATA hard disk drives for data redundancy\u003c\/li\u003e\n  \u003cli\u003eOptical Drive: DVD+\/-RW drive for software installation and data backup\u003c\/li\u003e\n  \u003cli\u003eLegacy Support: Includes a Floppy Disk Drive (FDD)\u003c\/li\u003e\n  \u003cli\u003ePre-installed Software: SIMATIC PCS7 V7.1 with Service Pack 3\u003c\/li\u003e\n  \u003cli\u003eOperating System: Windows Server 2003 Standard Edition with 5 Client Access Licenses (CALs)\u003c\/li\u003e\n  \u003cli\u003ePower Supply: 110\/230 V industrial power supply unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003eProcess Control Systems (PCS)\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) servers\u003c\/li\u003e\n  \u003cli\u003eHuman-Machine Interface (HMI) server stations\u003c\/li\u003e\n  \u003cli\u003eIndustrial data logging and archiving\u003c\/li\u003e\n  \u003cli\u003eEngineering and configuration workstations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f7fafc;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC Rack PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIPC547C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6ES7660-0DC13-2BA0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Core 2 Duo E8400\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCPU Clock Speed\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e3.0 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eFront Side Bus (FSB)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1333 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eL2 Cache\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProcessor Features\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEM64-T, VT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2.0 GB DDR2 SDRAM (2 x 1.0 GB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eStorage Configuration\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRAID1 (Mirroring)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eHard Drives\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 x 250 GB SATA HDD, internally mounted\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDVD+\/-RW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eFloppy Drive\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIncluded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePre-installed Software\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC PCS7 V7.1 + SP3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows Server 2003 Standard Edition, MUI (en\/de\/fr\/it\/es\/cn)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eClient Access Licenses (CAL)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e110\/230 V AC Industrial Power Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e15.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e64.0 x 64.0 x 42.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Ensure the unit is completely de-energized and locked out (LOTO) before handling, mounting, or connecting any cables. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Verify the installation environment is within the specified operating temperature and humidity ranges. Ensure the 19-inch rack has adequate clearance for airflow and cable management.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Use an anti-static wrist strap connected to a verified earth ground point before handling the IPC. Electrostatic discharge can damage sensitive internal components.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely install the IPC into the rack using all provided mounting points and appropriate hardware. Ensure the unit is level and fully supported by the rack rails.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis grounding terminal to the cabinet's protective earth (PE) bus bar using a low-impedance conductor. This is critical for both safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e Connect all required peripherals, such as monitors, keyboards, and network cables. Ensure all connectors are fully seated and secured.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower Up:\u003c\/strong\u003e After verifying all connections, connect the power cord to a suitable, protected power source. Power on the unit and verify that the operating system boots correctly.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716516376939,"sku":"6ES7660-0DC13-2BA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7660-0dc13-2ba0-pvgdvmjyeom_fdd94284-b3fb-4289-a460-091d4ae851a3.jpg?v=1767083854","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7660-0dc13-2ba0-simatic-ipc547c-industrial-workstation","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}