{"product_id":"siemens-6es7710-3ca13-0sb1-simatic-field-pg-programming-device","title":"Siemens 6ES7710-3CA13-0SB1 SIMATIC Field PG Programming Device","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 20px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7710-3CA13-0SB1 is a SIMATIC Field PG, a ruggedized portable computer engineered for commissioning, servicing, and maintaining industrial automation systems. This unit is equipped with a \u003cstrong\u003ePentium III 850 MHz\u003c\/strong\u003e processor, \u003cstrong\u003e128 MB of SDRAM\u003c\/strong\u003e, and a \u003cstrong\u003e30 GB EIDE hard drive\u003c\/strong\u003e. It comes pre-loaded with a suite of Siemens engineering software, including STEP 7, STEP 5, and STEP 7 Micro\/WIN, on a Windows NT V4.0 operating system, providing a comprehensive platform for legacy system support and field diagnostics.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003ePowered by an Intel Pentium III 850 MHz processor with 256 KB L2 Cache.\u003c\/li\u003e\n    \u003cli\u003eEquipped with 128 MB of SDRAM for application performance.\u003c\/li\u003e\n    \u003cli\u003eIncludes a 30 GB EIDE hard disk drive for project and data storage.\u003c\/li\u003e\n    \u003cli\u003eFeatures both a CD-ROM drive and a SuperDisk LS-240 drive for flexible media access.\u003c\/li\u003e\n    \u003cli\u003ePre-installed with Windows NT V4.0 (English) and a comprehensive Siemens software suite (STEP 7, STEP 5, Micro\/WIN).\u003c\/li\u003e\n    \u003cli\u003eIncludes a power cable suitable for use in multiple European countries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003ePLC programming and configuration for SIMATIC S5 and S7 systems.\u003c\/li\u003e\n    \u003cli\u003eOn-site commissioning and startup of industrial machinery.\u003c\/li\u003e\n    \u003cli\u003eField diagnostics, troubleshooting, and maintenance of automation equipment.\u003c\/li\u003e\n    \u003cli\u003eArchiving and managing legacy automation projects.\u003c\/li\u003e\n    \u003cli\u003eHMI and drive system configuration in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 400px;\"\u003e\n        \u003cthead style=\"background-color: #f7fafc;\"\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6ES7710-3CA13-0SB1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSIMATIC Field PG\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePentium III, 850 MHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eL2 Cache\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e256 KB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eMemory (RAM)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e128 MB SDRAM (1x128 MB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eHard Drive (HDD)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e30 GB EIDE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCD-ROM Drive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eRemovable Media Drive\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSuperDisk LS-240 Drive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eWindows NT V4.0 (English)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePre-installed Software\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSTEP 7, STEP 5, STEP 7 Micro\/WIN (Version from 08\/2001)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eIncluded Power Cable Regions\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePhase-Out\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e4.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e84713000\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e5D992\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e45 cm x 35 cm x 15 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eInstallation and Handling Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px 20px; margin-bottom: 20px;\"\u003e\n    \u003cp style=\"color: #c53030; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING: This is a legacy electronic device. Always handle with extreme care to prevent damage from electrostatic discharge (ESD) and physical shock. Use only the specified power supply and cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n        Place the Field PG on a clean, stable, and level surface with adequate ventilation to prevent overheating. Avoid operating in areas with high levels of dust, moisture, or vibration.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n        Before connecting to power, verify that the local mains voltage matches the requirements of the Field PG's power adapter. Connect the supplied power cable securely to the adapter and the wall outlet.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n        Use an anti-static wrist strap when connecting any communication cables (e.g., MPI, PROFIBUS) to the Field PG or the target automation device to prevent ESD damage to sensitive electronic components.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n        Power on the Field PG and allow the Windows NT operating system to load completely before launching any engineering software.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n        For transport, always shut down the operating system properly. Disconnect all cables and store the unit in a padded case to protect it from impact and environmental hazards.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716617400683,"sku":"6ES7710-3CA13-0SB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7710-3ca13-0sb1-oepnc0kas4x_69186bc6-aa13-4326-b9d0-b7c6d36bb8d3.jpg?v=1767086794","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6es7710-3ca13-0sb1-simatic-field-pg-programming-device","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}