{"product_id":"siemens-6gk5216-4gs00-2ac2-scalance-xc216-4c-g-managed-layer-2-ie-switch","title":"Siemens 6GK5216-4GS00-2AC2 SCALANCE XC216-4C G Managed Layer 2 IE Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5216-4GS00-2AC2 is a SCALANCE XC216-4C G managed Layer 2 Industrial Ethernet switch designed for robust performance in demanding automation environments. This full Gigabit switch provides a high-density port configuration with \u003cstrong\u003e12 RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003e4 flexible combo ports\u003c\/strong\u003e, suitable for either SFP fiber optic or copper RJ45 connections. It supports critical industrial protocols like \u003cstrong\u003ePROFINET IO\u003c\/strong\u003e and is \u003cstrong\u003eEthernet\/IP compliant\u003c\/strong\u003e, ensuring seamless integration into modern control systems. With features such as a redundant power supply, an extended operating temperature range, and a slot for a C-PLUG configuration memory module, this switch is engineered for high network availability and simplified device replacement.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eFull Gigabit performance across all ports for high-speed data transfer.\u003c\/li\u003e\n    \u003cli\u003eManaged Layer 2 switching with office features including RSTP and VLANs.\u003c\/li\u003e\n    \u003cli\u003ePROFINET IO device functionality for integration into Siemens automation networks.\u003c\/li\u003e\n    \u003cli\u003eEthernet\/IP compliant for interoperability with Rockwell\/Allen-Bradley systems.\u003c\/li\u003e\n    \u003cli\u003eExtended operating temperature range from -40 to +70 degC.\u003c\/li\u003e\n    \u003cli\u003eRedundant power supply input for increased operational reliability.\u003c\/li\u003e\n    \u003cli\u003eC-PLUG slot for easy device replacement without reprogramming.\u003c\/li\u003e\n    \u003cli\u003eCertified to IEC 62443-4-2 for industrial network security.\u003c\/li\u003e\n    \u003cli\u003eOnboard diagnostics LED for at-a-glance status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eFactory automation and plant-floor control networks.\u003c\/li\u003e\n    \u003cli\u003eProcess control systems requiring high network availability.\u003c\/li\u003e\n    \u003cli\u003eInfrastructure projects such as traffic control and utility management.\u003c\/li\u003e\n    \u003cli\u003eMachine-to-machine (M2M) communication links.\u003c\/li\u003e\n    \u003cli\u003eApplications in harsh environments with wide temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eXC216-4C G\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5216-4GS00-2AC2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Layer 2 Industrial Ethernet Switch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12 x 10\/100\/1000 Mbps\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCombo Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 x 1000 Mbps (configurable as SFP or RJ45)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eConsole Port\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIndustrial Protocols\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device, Ethernet\/IP Compliant\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundant Input\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e-40 to +70 degC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMounting Options\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDIN Rail, S7 Mounting Rail, Wall Mount\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSecurity Certification\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.52 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEAR99\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e20 x 15 x 10 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before commencing any installation or maintenance tasks. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003eDe-energize the control cabinet and verify the absence of voltage before handling the device.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003eSecurely mount the switch onto a standard DIN rail, S7 rail, or a flat panel\/wall surface using the appropriate mounting points. Ensure adequate clearance for ventilation and cable access.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003eConnect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the switch chassis. This is essential for safety and EMC performance.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003eConnect the primary and, if used, redundant DC power supply lines to the power input terminals, observing correct polarity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003eTerminate shielded Ethernet cables to the RJ45 ports. Ensure proper shield grounding at the cable gland or connector backshell to minimize noise interference.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan\u003eIf using fiber optic connections, insert the appropriate SFP transceivers into the combo port cages before connecting fiber optic patch cords.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n        \u003cspan\u003eInsert a C-PLUG memory module (if available) into the designated slot to enable automatic configuration backup and restore.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e8\u003c\/span\u003e\n        \u003cspan\u003eAfter all connections are secure, re-energize the cabinet and verify the status LEDs on the switch for power, link activity, and fault indications.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716748472683,"sku":"6GK5216-4GS00-2AC2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5216-4gs00-2ac2-wgmwpiu14j4_569ad2db-4fb5-49f9-9e7c-f745c77d3336.jpg?v=1767088634","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6gk5216-4gs00-2ac2-scalance-xc216-4c-g-managed-layer-2-ie-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}