{"product_id":"siemens-6gk5302-7gd00-3ea3-scalance-x302-7eec-managed-industrial-ethernet-switch","title":"Siemens 6GK5302-7GD00-3EA3 SCALANCE X302-7EEC Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n    \u003cp\u003eThe Siemens 6GK5302-7GD00-3EA3 is a compact, managed Industrial Ethernet switch from the SCALANCE X302-7EEC series. This device is engineered for industrial networking applications, providing a versatile port configuration with \u003cstrong\u003e2x 10\/100\/1000 Mbit\/s RJ45\u003c\/strong\u003e ports for high-speed connections and \u003cstrong\u003e7x 100 Mbit\/s LC fiber optic\u003c\/strong\u003e ports for long-distance or high-noise immunity links. It functions as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e, enabling seamless integration into Siemens automation environments. The switch supports a wide-range \u003cstrong\u003e100-240V AC\/DC power supply\u003c\/strong\u003e and includes an integrated redundancy manager to enhance network availability. A C-PLUG is included for straightforward device configuration backup and replacement.\u003c\/p\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eManaged Layer 2 switch with a compact, robust design for industrial use.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegrated redundancy manager for high network availability.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFunctions as a PROFINET IO device for direct automation system integration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eSupports standard office and IT protocols including RSTP, VLAN, and IGMP.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eOn-device diagnostics via integrated LEDs and an error signaling contact.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIncludes a C-PLUG removable storage medium for configuration backup.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFactory automation and machine-level control networks.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eProcess control systems requiring redundant communication paths.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eConnecting distributed I\/O and control devices over long distances using fiber optics.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegration into PROFINET-based automation architectures.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n            \u003cthead\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                    \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n                \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5302-7GD00-3EA3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE X302-7EEC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e100-240 V AC\/DC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eFiber Optic Ports\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e7x 100 Mbit\/s LC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManagement Features\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device, Network Management, RSTP, VLAN, IGMP\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundancy\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated Redundancy Manager\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.30 kg\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e21.6 cm x 11.0 cm x 14.3 cm\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n    \u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n        \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARD OF ELECTRIC SHOCK\u003c\/p\u003e\n        \u003cp style=\"margin-bottom: 0;\"\u003eDisconnect all power sources before installation or maintenance. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003col style=\"padding-left: 20px;\"\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e1\u003c\/span\u003e\n            Ensure the control cabinet is de-energized and locked out according to safety procedures. Verify the absence of voltage.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e2\u003c\/span\u003e\n            Mount the switch securely onto a standard 35mm DIN rail within the enclosure, ensuring adequate clearance for ventilation and cable access.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e3\u003c\/span\u003e\n            Connect a protective earth (PE) conductor to the designated grounding terminal on the switch chassis. A low-impedance ground connection is essential for safety and noise immunity.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e4\u003c\/span\u003e\n            Terminate the 100-240V AC\/DC power supply wiring to the correct terminals, observing polarity if applicable for DC sources.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e5\u003c\/span\u003e\n            Connect the RJ45 and LC fiber optic network cables. Ensure fiber optic connectors are clean before insertion and observe minimum bend radius requirements for all cables.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e6\u003c\/span\u003e\n            Insert the C-PLUG into its designated slot if using it for configuration storage.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e7\u003c\/span\u003e\n            After closing the cabinet and removing safety locks, re-energize the system. Verify the switch's status LEDs for correct power-up and network link activity.\n        \u003c\/li\u003e\n    \u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716504187243,"sku":"6GK5302-7GD00-3EA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5302-7gd00-3ea3-snvk2jdfvsg_766ba33e-fdea-418c-85c3-2078b001fdfb.jpg?v=1767083608","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-6gk5302-7gd00-3ea3-scalance-x302-7eec-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}