{"product_id":"siemens-scalance-xr328-4c-wg-managed-industrial-ethernet-switch","title":"Siemens SCALANCE XR328-4C WG Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5328-4SS00-3AR3 is a SCALANCE XR328-4C WG managed Industrial Ethernet switch designed for high-density networking in standard 19-inch rack environments. This device provides a total of \u003cstrong\u003e28 gigabit-capable ports\u003c\/strong\u003e, including twenty-four electrical ports and four flexible combo ports for either copper or fiber optic connections. Key features include an integrated \u003cstrong\u003eredundancy manager\u003c\/strong\u003e, PROFINET device functionality, and certification to the \u003cstrong\u003eIEC 62443-4-2\u003c\/strong\u003e cybersecurity standard, making it suitable for critical control system networks.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eManaged Layer 2 Industrial Ethernet (IE) switch\u003c\/li\u003e\n  \u003cli\u003eStandard 19-inch rack-mount form factor\u003c\/li\u003e\n  \u003cli\u003eTwenty-four 10\/100\/1000 Mbps electrical RJ45 ports\u003c\/li\u003e\n  \u003cli\u003eFour 1000 Mbps combo ports for electrical (RJ45) or optical (SFP) use\u003c\/li\u003e\n  \u003cli\u003eIntegrated redundancy manager for high-availability networks\u003c\/li\u003e\n  \u003cli\u003eFunctions as a PROFINET device\u003c\/li\u003e\n  \u003cli\u003eFront-panel LED diagnostics for status monitoring\u003c\/li\u003e\n  \u003cli\u003eOnboard reset button and console port for local management\u003c\/li\u003e\n  \u003cli\u003eCertified according to IEC 62443-4-2 for industrial security\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003ePlant-level network backbones and aggregation\u003c\/li\u003e\n  \u003cli\u003eControl room and data center network infrastructure\u003c\/li\u003e\n  \u003cli\u003eConnecting multiple machine cells or production lines\u003c\/li\u003e\n  \u003cli\u003eHigh-availability automation networks requiring redundant paths\u003c\/li\u003e\n  \u003cli\u003eSecure integration of IT and OT network segments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eCategory\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eGeneral\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSCALANCE XR328-4C WG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6GK5328-4SS00-3AR3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eElectrical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e240 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e85 V AC to 264 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eInterfaces\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eElectrical Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24 x RJ45 (10\/100\/1000 Mbps)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eCombo Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e4 x 1000 Mbps (Electrical RJ45 or Optical SFP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eManagement Port\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConsole Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n       \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eMechanical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eForm Factor\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e19-inch rack mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eCertifications \u0026amp; Standards\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eCybersecurity\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eLogistics \u0026amp; Shipping\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2.70 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e48.30 cm x 17.70 cm x 4.40 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUSA (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px; padding-left: 25px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin-bottom: 0;\"\u003eThis equipment is intended for use in restricted access locations by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance. Failure to properly ground the unit can result in electrical shock and equipment damage. Always verify the absence of voltage before handling conductors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eEnsure the control cabinet or rack is fully de-energized and locked out according to local safety procedures.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eVerify adequate clearance for ventilation around the switch. Do not block air vents. Confirm the 19-inch rack has sufficient space and structural support.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eMount the switch into the 19-inch rack using the appropriate screws and cage nuts for all four mounting points. Ensure the unit is level and secure.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect a low-impedance protective earth (PE) conductor to the chassis grounding terminal. This connection is mandatory for safety and EMI performance.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eConnect the AC power supply cord to the switch's power inlet. Ensure the source voltage is within the specified range of 85-264V AC.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eConnect network cables to the appropriate RJ45 or SFP ports. Use shielded cabling in electrically noisy environments.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003eRemove the lockout\/tagout devices and re-energize the cabinet. Verify the power and status LEDs on the switch indicate normal operation.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716676776299,"sku":"6GK5328-4SS00-3AR3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5328-4ss00-3ar3-sio31nlevry_db1e7dcd-918b-4d68-a02d-93d620d84a72.jpg?v=1767087863","url":"https:\/\/www.plcprotech.com\/ru\/products\/siemens-scalance-xr328-4c-wg-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}