{"title":"Bently Nevada 9200 \u0026 74712 Two-wire Transducer","description":"\u003cp\u003eThe Bently Nevada 9200 and 74712 Two-wire Transducers are seismic velocity sensors designed for continuous vibration monitoring on machine housings. The architecture utilizes a moving-coil design that eliminates the need for external power, producing a voltage proportional to the vibration velocity. Technical characteristics include a wide operating temperature range and a rugged design capable of withstanding high-impact industrial environments. Functionally, these transducers are specialized for monitoring low-to-mid frequency vibrations on large motors, pumps, and fans. They are often integrated with the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-system-monitoring\"\u003e3300 system monitoring\u003c\/a\u003e racks or connected via \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-vibration-transmitters\"\u003evibration transmitters\u003c\/a\u003e to provide a simplified, reliable seismic measurement solution where non-contact proximity probes are not technically feasible.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-9200-06-02-10-00-two-wire-transducer","title":"Bently Nevada 9200-06-02-10-00 ทรานสดิวเซอร์สองสาย","description":"\u003cp\u003eThe \u003cstrong\u003e9200\u003c\/strong\u003e ทรานสดิวเซอร์วัดความเร็วมาตรฐาน หมายเลขชิ้นส่วนสมบูรณ์ \u003cstrong\u003e9200-06-02-10-00\u003c\/strong\u003e, เป็นทรานสดิวเซอร์แบบขดลวดเคลื่อนที่สองสายที่ออกแบบมาเพื่อวัดการสั่นสะเทือนของตัวเรือนแบบสัมบูรณ์บนเครื่องจักรหมุน ระบบกลไกมีขดลวดแขวนด้วยสายลวดเคลื่อนที่รอบแม่เหล็กถาวร ให้แรงดันไฟฟ้าออกที่สัมพันธ์โดยตรงกับความเร็วการสั่นสะเทือน เซ็นเซอร์ชนิดนี้ผลิตพลังงานเองโดยไม่ต้องใช้ไฟฟ้าภายนอกและทำงานภายในหน้าต่างทิศทางเฉพาะที่กำหนดโดยการตั้งค่าตัวเลือกเฉพาะ ซีรีส์ 9200 ใช้หลักการไดนามิกของโรเตอร์เพื่อตรวจสอบการเคลื่อนไหวของโครงสร้างตัวเรือนอย่างต่อเนื่อง เพื่อปกป้องเครื่องจักรที่สำคัญและเชื่อมต่อโดยตรงกับระบบตรวจสอบของ Bently Nevada ผ่านการส่งสัญญาณความต้านทานต่ำ\u003c\/p\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06: มุมการติดตั้งทรานสดิวเซอร์ \/ ความถี่การทำงานขั้นต่ำ\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0 ±100° (ทิศทางการติดตั้งแนวนอน), ความถี่การทำงานขั้นต่ำ 10 Hz (600 cpm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: ตัวเลือกขั้วต่อ\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eอินเทอร์เฟซขั้วต่อ 2 พินแบบปิดผนึกอย่างแน่นหนา ติดตั้งด้านข้าง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10: ตัวเลือกฐานติดตั้ง\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eรูปทรงฐานทรงกลมพร้อมการเชื่อมต่อสกรูเกลียว M10X1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: ตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eไม่ต้องการการอนุมัติหรือใบรับรองพื้นที่อันตรายมาตรฐาน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อกำหนดฮาร์ดแวร์\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-02-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภททรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทรานสดิวเซอร์แบบขดลวดเคลื่อนที่สองสาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eทิศทางการติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100° (แนวนอน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความถี่การทำงานขั้นต่ำ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eทิศทางของขั้วต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eติดตั้งด้านข้าง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรูปทรงฐานติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eฐานติดตั้งทรงกลมพร้อมสกรูเกลียว M10X1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุตัวเรือนและอะแดปเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอะลูมิเนียมอโนไดซ์ A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความสูงของเซ็นเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความสูงทั่วไป 102 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเส้นผ่านศูนย์กลางเซ็นเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางทั่วไป 41 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการอนุมัติ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไม่มี\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกทางวิศวกรรม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eตรวจสอบให้แน่ใจว่ามุมการติดตั้งเซ็นเซอร์ตรงกับช่วงแนวนอน 0 ±100° อย่างแม่นยำเพื่อหลีกเลี่ยงการพันกันของขดลวดภายในกับตัวแม่เหล็ก\u003c\/li\u003e\n\u003cli\u003eการใช้งานทรานสดิวเซอร์ที่ความถี่ต่ำกว่าขีดจำกัด 10 Hz ที่ระบุไว้จะทำให้เกิดการลดทอนแอมพลิจูดอย่างมีนัยสำคัญและข้อผิดพลาดในการเปลี่ยนเฟสของข้อมูลความเร็ว\u003c\/li\u003e\n\u003cli\u003eความไวต่อการสั่นสะเทือนในแนวแกนขวางต้องลดให้น้อยที่สุดโดยการจัดแนวแกนการวัดหลักให้ขนานโดยตรงกับทิศทางการสั่นสะเทือนของเครื่องจักรที่ตั้งใจไว้\u003c\/li\u003e\n\u003cli\u003eชุดขดลวดสร้างแรงดันไฟฟ้าเองนี้มีอิมพีแดนซ์ภายในคงที่ที่ต้องจับคู่กับอินพุตเครื่องมือวัดที่เข้ากันได้เพื่อป้องกันผลกระทบจากการโหลดสัญญาณ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eแนวทางภาคสนาม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eดำเนินการต่อสายดินของชิลด์อย่างเฉพาะเจาะจงโดยเชื่อมต่อชิลด์สายเคเบิลที่ปลายแร็คตรวจสอบเท่านั้น ให้ปลายทรานสดิวเซอร์แยกออกเพื่อกำจัดวงจรดิน\u003c\/li\u003e\n\u003cli\u003eรักษาการแยกเส้นทางสายไฟอย่างเหมาะสมโดยแยกสายสัญญาณทรานสดิวเซอร์ออกจากท่อจ่ายไฟ AC แรงดันสูงเพื่อลดการรบกวนแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003cli\u003eหลีกเลี่ยงการงอสายไฟสนามต่ำกว่ารัศมีขั้นต่ำเพื่อป้องกันความเสียหายของตัวนำภายในหรือการเสื่อมสภาพของฉนวน\u003c\/li\u003e\n\u003cli\u003eตรวจสอบความสมบูรณ์ของพื้นผิวยึด M10X1 ให้เรียบเนียน ไม่มีสีหรือเศษสิ่งสกปรก เพื่อรับประกันการส่งผ่านการสั่นสะเทือนความถี่สูงที่แม่นยำ\u003c\/li\u003e\n\u003cli\u003eใช้แรงบิดที่ถูกต้องเมื่อยึดฐานยึดแบบวงกลมกับตัวเครื่องเพื่อป้องกันความถี่เรโซแนนซ์ที่อาจทำให้การอ่านความเร็วผิดเพี้ยน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อยด้านเทคนิคและการจัดซื้อ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: รุ่น 9200-06-02-10-00 นี้สามารถติดตั้งในแนวตั้งล้วนบนตัวเครื่องได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ไม่ใช่ รหัสต่อท้าย -06 หมายถึงการติดตั้งในแนวนอนที่ 0 ±100 องศา; การติดตั้งในแนวตั้งต้องใช้รหัสตัวเลือกที่แตกต่างกันเพื่อปรับเทียบการจัดแนวสปริงขดภายใน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: อะไรบ้างที่รวมอยู่ในกล่องจัดส่งสำหรับหมายเลขชิ้นส่วนนี้?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ชุดประกอบนี้ประกอบด้วยชุดทรานสดิวเซอร์ความเร็วรุ่นใหม่ล่าสุด 9200-06-02-10-00 พร้อมขั้วต่อด้านข้างแบบบูรณาการและฐานยึดแบบวงกลม M10X1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: โมดูลทรานสดิวเซอร์เฉพาะนี้ต้องการแหล่งจ่ายไฟภายนอกแยกต่างหากเพื่อส่งสัญญาณความเร็วหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ไม่ใช่ นี่คือเซ็นเซอร์ขดลวดเคลื่อนที่แม่เหล็กไฟฟ้าที่สร้างแรงดันไฟฟ้าเอาต์พุตของตัวเองตามความเร็วโดยไม่ต้องใช้พลังงานจากวงจรภายนอก\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764493163,"sku":"9200-06-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-02-10-00-two-wire-transducer-wh1b32koul4_e61ad530-9ea0-4ba5-a008-11769c81ce20.jpg?v=1765447197"},{"product_id":"bently-nevada-9200-01-05-10-00-two-wire-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-01-05-10-00 เครื่องแปลงความเร็วแบบสองสาย Seismoprobe","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eBently Nevada 9200-01-05-10-00 เป็นเครื่องแปลงแบบขดลวดเคลื่อนที่สองสายที่ออกแบบมาเพื่อประเมินการสั่นสะเทือนสัมบูรณ์ของตัวเรือนแบริ่ง ตัวเรือน หรือโครงสร้างเทียบกับพื้นที่ว่าง โดยใช้เทคโนโลยีขดลวดเคลื่อนที่แบบอิเล็กโทรไดนามิกเฉพาะ ตัวเซ็นเซอร์นี้ให้สัญญาณแรงดันไฟฟ้าที่สัมพันธ์โดยตรงกับความเร็วการสั่นสะเทือนของตัวเรือนทางกล ด้วยสถาปัตยกรรมภายในทางกล ทำให้มีความไวต่อแรงกระแทกโครงสร้างในพื้นที่จำกัดหรือตื่นตัวแบบกระแทกน้อยกว่าตัวเซ็นเซอร์แบบโซลิดสเตตทั่วไป จึงเป็นตัวเลือกที่ยอดเยี่ยมสำหรับการปกป้องเครื่องจักรหนักอย่างต่อเนื่องและการประเมินวินิจฉัยภาคสนาม ทำงานเป็นอุปกรณ์สร้างพลังงานเองโดยไม่ต้องใช้วงจรจ่ายไฟภายนอก รหัสการกำหนดค่า 9200-01-05-10-00 ระบุเครื่องแปลงที่ปรับแต่งสำหรับระนาบติดตั้งแนวนอน (0 ±2.5 องศา) พร้อมความถี่การทำงานขั้นต่ำต่ำที่ 4.5 Hz มีตัวเชื่อมต่อบล็อกเทอร์มินัลติดตั้งด้านบนในตัว และสตัดเกลียวติดตั้งทรงกลม M10X1\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eสถาปัตยกรรมขดลวดเคลื่อนที่:\u003c\/strong\u003e ให้ความต้านทานสูงต่อการเปลี่ยนแปลงโครงสร้างและแรงกระแทกทางกลในพื้นที่จำกัด\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eการทำงานแบบสร้างพลังงานเอง:\u003c\/strong\u003e ไม่ต้องใช้แหล่งจ่ายไฟภายนอก ลดโครงสร้างสายไฟในภาคสนาม\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eการปรับแต่งระนาบแนวนอน:\u003c\/strong\u003e ตั้งค่าล่วงหน้าสำหรับการติดตั้งที่มุม 0 ±2.5 องศา ช่วยให้ติดตามความถี่ต่ำได้ถึง 4.5 Hz\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eบล็อกเทอร์มินัลติดตั้งด้านบน:\u003c\/strong\u003e มีการเชื่อมต่อเทอร์มินัลแบบโพลีฟีนิลีนซัลไฟด์ในตัวพร้อมขั้วทองแดงชุบด้วยนิกเกิล ป้องกันการพึ่งพาสายเคเบิลเฉพาะ\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eตัวเรือนกลไกที่ทนทาน:\u003c\/strong\u003e ตัวบอดี้ชิ้นส่วนทำจากอะลูมิเนียมอโนไดซ์ A204 พร้อมปะเก็นซีลกันสิ่งแวดล้อมแบบนีโอพรีนที่ทนทาน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eการตรวจสอบการสั่นสะเทือนของตัวเรือนอย่างต่อเนื่องบนบล็อกแบริ่งอุตสาหกรรมและตัวเรือนเครื่องจักรหมุน\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eการวัดความเร็วแบบสัมบูรณ์บนปั๊มกระบวนการขนาดกลาง, พัดลมระบายความร้อน และกังหันไอน้ำรุ่นเก่า\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eการเก็บข้อมูลภาคสนาม, การปรับสมดุลเครื่องจักรแบบพกพา และการสำรวจวิศวกรรมวินิจฉัย\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eการประเมินการสั่นสะเทือนโครงสร้างและการติดตามการจัดแนวผิดพลาดในอุปกรณ์หมุนของโรงงาน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eรหัสตัวเลือก\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eความหมายของการเลือก\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eค่าทางเทคนิค \/ รายละเอียด\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e9200\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eรุ่นเครื่องแปลงฐาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eเครื่องแปลงความเร็วแบบสองสายสำหรับเซย์สโมโพรบ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eมุมติดตั้ง \/ ความถี่ขั้นต่ำ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 ±2.5 องศา, 4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e05\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเลือกตัวเชื่อมต่อ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eบล็อกเทอร์มินัลติดตั้งด้านบน\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e10\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเลือกฐานติดตั้ง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eฐานทรงกลม; สตัด M10X1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eไม่ต้องการการอนุมัติ\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eพารามิเตอร์\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eค่าข้อมูลจำเพาะ\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความไว\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% ที่ทิศทางการสอบเทียบ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eการตอบสนองความถี่\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4.5 Hz ถึง 1000 Hz (270 ถึง 60,000 รอบต่อนาที); +0, -3 dB ทั่วไป\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงการทำงานแบบไดนามิก\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eการเคลื่อนที่สูงสุดแบบพีคทูพีค 2.54 มม. (0.100 นิ้ว)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงความเร็ว\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความทนทาน ±5% จาก 0.254 ถึง 127 มม.\/วินาที (0.01 ถึง 5.0 นิ้ว\/วินาที) ที่ 100 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความต้านทานคอยล์\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.25 kOhm ±5%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eค่าคอยล์เหนี่ยวนำล็อก\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e125 mH ค่าทั่วไป\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eโหลดทดสอบการสอบเทียบ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 kOhm ระหว่างขั้วต่อ A และขั้วต่อ B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eสัมประสิทธิ์อุณหภูมิความไว\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-0.02% ต่อองศาเซลเซียส (-0.011% ต่อองศาฟาเรนไฮต์) การเปลี่ยนแปลงทั่วไป\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความไวแกนขวาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความไวแกนขวางน้อยกว่า 10% ของความกว้างสูงสุดที่ 100 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความต้านทานแรงกระแทก\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eทนต่อแรงเร่งสูงสุด 50 g ตามแกนที่ไม่ไวต่อการวัด\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงอุณหภูมิการทำงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-29 องศาเซลเซียส ถึง +121 องศาเซลเซียส (-20 องศาฟาเรนไฮต์ ถึง +250 องศาฟาเรนไฮต์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงความชื้นสัมพัทธ์\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความชื้นสัมพัทธ์สูงสุด 95% ในสภาพแวดล้อมที่ไม่ควบแน่น\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความสูงใช้งานสูงสุด\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความสูงใช้งานสูงสุด 2000 เมตร (6,561 ฟุต) เหนือระดับน้ำทะเล\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eวัสดุตัวเรือนและซีล\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเรือนอลูมิเนียมอโนไดซ์ A204; ปะเก็นนีโอพรีน\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eค่าการขันแรงบิดติดตั้ง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eแรงบิดสูงสุด 5.6 N-m (50 in-lb) บนสตัดฐานเกลียวฐาน\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดทางกายภาพ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความสูงรวม 102 มม. เส้นผ่านศูนย์กลางภายนอกทั่วไป 41 มม.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (บริษัทในเครือ Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 กก.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e180 มม. x 120 มม. x 100 มม.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eการกำหนดขั้วต่อ\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eฟังก์ชัน \/ การกำหนดวงจร\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขั้วต่อ A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสัญญาณบวกขาออก (แสดงค่าบวกเมื่อเทียบกับขั้วต่อ B เมื่อการเคลื่อนที่มุ่งไปยังตัวเชื่อมต่อ)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขั้วต่อ B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสัญญาณลบกลับ \/ จุดอ้างอิงร่วม\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eคำเตือนสำคัญ\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eแยกและปิดระบบวงจรตรวจสอบเครื่องจักรและเครื่องจักรควบคุมภาคสนามทั้งหมดอย่างสมบูรณ์ก่อนทำการติดตั้งหรือเปลี่ยนอุปกรณ์ใดๆ การทำงานกับระบบภาคสนามที่ยังทำงานอยู่ในพื้นที่อันตรายอาจก่อให้เกิดอันตรายทางไฟฟ้า ทำให้วงจรควบคุมผิดพลาด หรือทำให้เครื่องจักรหยุดทำงานโดยไม่ตั้งใจ\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eวิศวกรภาคสนามต้องปฏิบัติตามลำดับทางเทคนิคต่อไปนี้อย่างเคร่งครัดในระหว่างการติดตั้งภาคสนาม:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eตรวจสอบให้แน่ใจว่าพื้นผิวตัวเครื่องจักรเป้าหมายถูกกลึงให้เรียบตั้งฉากกับแกนการวัด และสะอาดปราศจากสีหรือชั้นออกไซด์สะสม\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eจัดแนวชุดทรานสดิวเซอร์ให้อยู่ในเกณฑ์การติดตั้งแนวนอนที่กำหนดไว้ที่ 0 ±2.5 องศา เพื่อให้เป็นไปตามข้อจำกัดความถี่ต่ำ\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eใช้ประแจแรงบิดที่ปรับเทียบแล้วขันสตัดฐานติดตั้งแบบบูรณาการ M10X1 ให้แน่นที่แรงบิด 5.6 N-m (50 in-lb) เท่านั้น ห้ามเกินขีดจำกัดนี้\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eเดินสายคู่บิดเกลียวและมีชิลด์เข้าสู่ขั้วต่อ A และขั้วต่อ B บนบล็อกขั้วต่อที่ติดตั้งด้านบน โดยต้องแน่ใจว่ามีการปิดผนึกท่ออย่างเหมาะสมเพื่อรักษาความสมบูรณ์ของวงจร\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851623275,"sku":"9200-01-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-01-05-10-00-seismoprobe-transducer-eoewqvonmlx_473b913f-7e0b-4ba9-90fe-8bcfa680a083.jpg?v=1765449064"},{"product_id":"bently-nevada-9200-06-05-05-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-05-00 เซนเซอร์วัดความเร็วแบบ Seismoprobe","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 9200-06-05-05-00\u003c\/strong\u003e เป็น\u003cstrong\u003eทรานสดิวเซอร์วัดความเร็ว\u003c\/strong\u003eแบบสองสายที่ออกแบบมาสำหรับการตรวจสอบอย่างต่อเนื่องหรือการวินิจฉัยเป็นระยะของการสั่นสะเทือนตัวเรือนแบบสัมบูรณ์ ตัวเรือนแบริ่ง หรือโครงสร้าง โดยใช้เทคโนโลยีขดลวดเคลื่อนที่ เครื่องมือนี้สร้างเอาต์พุตแรงดันไฟฟ้าที่สัดส่วนโดยตรงกับความเร็วการสั่นสะเทือนของทรานสดิวเซอร์โดยไม่ต้องใช้พลังงานภายนอก สถาปัตยกรรมทางกลที่เป็นเอกลักษณ์ของ \u003cstrong\u003e9200-06-05-05-00\u003c\/strong\u003e ช่วยให้มีความไวต่ำต่อแรงกระแทกหรือการกระตุ้นแบบเฉียบพลัน ส่งมอบข้อมูลไดนามิกที่เชื่อถือได้และทำซ้ำได้สูงสำหรับเครื่องจักรสำคัญ เช่น กังหัน ปั๊ม และพัดลมอุตสาหกรรม  \u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเทคโนโลยีขดลวดเคลื่อนที่ให้เอาต์พุตแรงดันไฟฟ้าโดยตรงโดยไม่ต้องใช้พลังงานภายนอก  \u003c\/li\u003e\n\u003cli\u003eความไวต่ำต่อแรงกระแทกหรือการกระตุ้นแบบเฉียบพลันเมื่อเทียบกับทางเลือกแบบโซลิดสเตต  \u003c\/li\u003e\n\u003cli\u003eการสนับสนุนแบบสองสายสำหรับการปกป้องเครื่องจักรถาวรและการวัดภาคสนามแบบพกพา  \u003c\/li\u003e\n\u003cli\u003eตัวเรือนอะลูมิเนียมอโนไดซ์ที่ทนทานสำหรับการใช้งานในสภาพแวดล้อมอุตสาหกรรมที่รุนแรง  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการวัดการสั่นสะเทือนของตัวเรือนแบริ่งและตัวเรือนเครื่องจักรแบบสัมบูรณ์  \u003c\/li\u003e\n\u003cli\u003eโปรโตคอลการตรวจสอบตัวเรือนกังหันไอน้ำและก๊าซ  \u003c\/li\u003e\n\u003cli\u003eการเก็บข้อมูลเป็นระยะโดยใช้เครื่องมือทดสอบและวินิจฉัยแบบพกพา  \u003c\/li\u003e\n\u003cli\u003eการวิเคราะห์การสั่นสะเทือนโครงสร้างบนอุปกรณ์สมดุลขนาดใหญ่ของโรงงาน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eตัวเลือก \/ รหัส  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eโปรไฟล์การกำหนดค่าจากโรงงาน  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทรานสดิวเซอร์วัดความเร็วแบบสองสาย Seismoprobe  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eมุมติดตั้งทรานสดิวเซอร์\/ความถี่การทำงานขั้นต่ำ: 0 ±100, 10 Hz (600 cpm)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกตัวเชื่อมต่อ: บล็อกเทอร์มินัลติดตั้งด้านบน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกฐานยึด: ไม่มีฐาน; สตัด 1\/2 นิ้ว 20 UNF-3A  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน: ไม่ต้องการการอนุมัติ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรุ่น  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทรานสดิวเซอร์วัดความเร็วแบบสองสาย  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความไว  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% ที่ +22 องศาเซลเซียส (+72 องศาฟาเรนไฮต์) กับการสั่นสะเทือน 25 มม.\/วินาที (1 นิ้ว\/วินาที) ที่ 100 Hz เข้ากับโหลด 10 kΩ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการตอบสนองความถี่  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz ถึง 1 kHz (60,000 cpm); +0, -3dB โดยทั่วไป  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eทิศทางการใช้งาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (แนวตั้ง มองจากปลายด้านคนขับ)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงการทำงานแบบไดนามิก  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการเคลื่อนที่สูงสุดจากยอดถึงยอด 2.54 มม. (0.100 นิ้ว)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานต่อแรงกระแทก  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทนต่อแรงเร่งสูงสุด 50 g ตามแกนที่ไม่ไวต่อการตรวจจับ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความไวตามแนวขวาง  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% สูงสุด  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความยาวสายไฟสูงสุด  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 เมตร (1,000 ฟุต) ระหว่างทรานสดิวเซอร์กับมอนิเตอร์ 3300 หรือ 3500  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการใช้งาน\/การเก็บรักษา  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 องศาเซลเซียส ถึง +121 องศาเซลเซียส (-20 องศาฟาเรนไฮต์ ถึง +250 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความชื้นสัมพัทธ์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์สูงสุด 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุตัวเรือน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอะลูมิเนียมอโนไดซ์ A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุแผ่นกันรั่ว\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eนีโอพรีน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุขั้วต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโพลีฟีนิลีนซัลไฟด์พร้อมขั้วทองแดงชุบ นิกเกิล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกฐานติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไม่มีฐาน; สตัด 1\/2 นิ้ว 20 UNF-3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแรงบิดติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eแรงบิดติดตั้ง 5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความสูง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความสูงประมาณ 78.54 มม. (3.092 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเส้นผ่านศูนย์กลาง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลาง 41.40 มม. (1.63 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักประมาณ 300 กรัม (10.5 ออนซ์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเทศต้นทาง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขาเชื่อมต่อ \/ เทอร์มินัล\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเทอร์มินัล A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตบวก (ขา A เป็นบวกเมื่อเทียบกับขา B เมื่อความเร็วของตัวเรือนเคลื่อนที่ไปทางขั้วต่อ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเทอร์มินัล B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วลบกลับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจัดแนวทิศทาง:\u003c\/strong\u003e ทรานสดิวเซอร์ต้องติดตั้งทางกายภาพภายในขอบเขตแนวตั้ง 0 ±100 องศาเมื่อเทียบกับมุมการสอบเทียบ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eแรงบิดที่กำหนด:\u003c\/strong\u003e ขันเกลียวติดตั้ง 1\/2 นิ้ว 20 UNF-3A ในตัวให้แน่นที่ 5.6 Nm (50 in-lb) เพื่อรับประกันการส่งผ่านความถี่ที่เหมาะสม\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eเส้นทางการสั่นสะเทือน:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าจุดเชื่อมต่อโครงสร้างที่เลือกส่งผ่านความผิดปกติของโรเตอร์ภายในไปยังตัวเรือนภายนอกที่ติดตั้งทรานสดิวเซอร์อย่างถูกต้อง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปิดผนึกสิ่งแวดล้อม:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าขั้วต่อบล็อกเทอร์มินัลด้านบนถูกปิดสนิทและป้องกันฝุ่นและความชื้นในพื้นที่ได้อย่างสมบูรณ์\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eการกำหนดฐานติดตั้งแบบ 05 หมายความว่าอย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรหัส -05 หมายความว่าทรานสดิวเซอร์นี้ไม่มีฐานแปลนวงกลมหรือสี่เหลี่ยมแยกต่างหาก แต่มีสตัดเกลียว 1\/2 นิ้ว 20 UNF-3A ติดตั้งมาในตัวที่ด้านล่างสำหรับการติดตั้ง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eขีดจำกัดความถี่การทำงานต่ำสุดของเซ็นเซอร์ความเร็วนี้คือเท่าไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรุ่นนี้มีตัวเลือกความถี่ -06 ซึ่งกำหนดขีดจำกัดความถี่ต่ำสุดที่ 10 Hz (600 cpm) ก่อนที่สัญญาณจะเริ่มลดทอน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eหลักการขดลวดเคลื่อนที่ช่วยให้ทรานสดิวเซอร์นี้ดีกว่าเครื่องวัดความเร่งมาตรฐานอย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเนื่องจากใช้เทคโนโลยีขดลวดเคลื่อนที่แทนการรวมผลึกแบบโซลิดสเตต จึงมีความทนทานมากกว่าและไวต่อแรงกระแทกหรือแรงกระตุ้นอย่างฉับพลันน้อยกว่าอย่างมาก\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้แหล่งจ่ายไฟภายนอกหรือเครื่องขยายสัญญาณชาร์จสำหรับการเดินสายหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ ระบบความเร็วแบบสองสายนี้เป็นระบบที่สร้างสัญญาณแรงดันไฟฟ้าโดยตรงจากการเคลื่อนที่ของขดลวดภายในเองทั้งหมด ทำให้มีความยืดหยุ่นสูงสำหรับงานพกพาและงานวินิจฉัย\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853720427,"sku":"9200-06-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-05-00-velocity-seismoprobe-w514jt2zgqz_3f2acb0a-f4fb-455f-8d51-77fd859d0a50.jpg?v=1765449119"},{"product_id":"bently-nevada-9200-02-01-10-00-two-wire-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-02-01-10-00 เซ็นเซอร์วัดความเร็วแบบสองสาย Seismoprobe","description":"\u003ch3\u003eคำอธิบาย  \u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e9200-02-01-10-00\u003c\/strong\u003e เป็นทรานสดิวเซอร์วัดความเร็วแบบสองสายที่ออกแบบมาเพื่อการตรวจสอบการสั่นสะเทือนของเครื่องจักรอย่างต่อเนื่องหรือการวัดวินิจฉัยเป็นระยะเมื่อใช้ร่วมกับเครื่องมือทดสอบ อุปกรณ์ขดลวดเคลื่อนที่นี้วัดการสั่นสะเทือนของตัวเครื่องแบบสัมบูรณ์โดยสร้างแรงดันไฟฟ้าที่สัมพันธ์กับความเร็วของทรานสดิวเซอร์ เมื่อเลือกใช้กับการกำหนดค่าสายเคเบิลแบบบูรณาการ \u003cstrong\u003e9200-02-01-10-00 Seismoprobe\u003c\/strong\u003e จะมีความต้านทานสูงต่อสภาพแวดล้อมกัดกร่อนโดยไม่ต้องใช้ตัวเรือนป้องกันภายนอก สามารถเชื่อมต่อโดยตรงกับระบบตรวจสอบเพื่อให้การปกป้องเครื่องจักรที่เชื่อถือได้และการเก็บข้อมูลบำรุงรักษาเชิงคาดการณ์\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการออกแบบขดลวดเคลื่อนที่ที่ให้แรงดันไฟฟ้าออกเองซึ่งสัมพันธ์กับความเร็วโดยไม่ต้องใช้พลังงานภายนอก  \u003c\/li\u003e\n\u003cli\u003eการกำหนดค่าทางไฟฟ้าสองสายที่ช่วยให้ง่ายต่อการเดินสายในพื้นที่ระยะไกล  \u003c\/li\u003e\n\u003cli\u003eทนทานสูงต่อบรรยากาศกัดกร่อนและมลพิษสิ่งแวดล้อมเมื่อใช้ตัวเลือกสายเคเบิลแบบบูรณาการ  \u003c\/li\u003e\n\u003cli\u003eรองรับการติดตั้งหลายมุมที่เหมาะสมสำหรับการวัดการสั่นสะเทือนในทิศทางเฉพาะ  \u003c\/li\u003e\n\u003cli\u003eตัวเรือนกลไกที่ทนทานออกแบบมาเพื่อทนต่อสภาพแวดล้อมอุตสาหกรรมที่รุนแรง  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการสั่นสะเทือนของตัวเครื่องบนปั๊มอุตสาหกรรม พัดลม และเครื่องเป่า  \u003c\/li\u003e\n\u003cli\u003eการเก็บข้อมูลบำรุงรักษาเชิงคาดการณ์บนกังหันไอน้ำและกังหันแก๊ส  \u003c\/li\u003e\n\u003cli\u003eระบบป้องกันต่อเนื่องสำหรับเกียร์บ็อกซ์และมอเตอร์ไฟฟ้าขนาดใหญ่  \u003c\/li\u003e\n\u003cli\u003eการทดสอบวินิจฉัยและการวิเคราะห์การสั่นสะเทือนโครงสร้างในโรงงานปิโตรเคมีและโรงไฟฟ้า  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสตัวเลือก  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบาย  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรุ่น: 9200  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทรานสดิวเซอร์วัดความเร็วแบบสองสาย Seismoprobe  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eมุมการติดตั้งทรานสดิวเซอร์ \/ ความถี่การทำงานขั้นต่ำ: 45 +\/-2.5 องศา, 4.5 Hz (270 cpm)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกตัวเชื่อมต่อ: ติดตั้งด้านบน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกฐานยึด: แบบวงกลม; สตัด M10X1  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน: ไม่ต้องการการอนุมัติ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเทศต้นทาง  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความไว  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s), +\/-5% ที่ +22 องศาเซลเซียส (+72 องศาฟาเรนไฮต์) พร้อมการสั่นสะเทือนของตัวเครื่องที่ 25 mm\/s (1 in\/s) ที่ 100 Hz (6000 cpm) โดยมีโหลด 10 กิโลโอห์ม  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการตอบสนองความถี่\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตั้งแต่ 4.5 Hz (270 cpm) ถึง 1 kHz (60,000 cpm); +0, -3dB โดยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงการทำงานแบบไดนามิก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการเคลื่อนที่สูงสุด 2.54 มม. (0.100 นิ้ว) จากจุดสูงสุดถึงจุดต่ำสุด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานแรงกระแทก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eทนต่อแรงกระแทกสูงสุด 50 g ตามแกนที่ไม่ไวต่อแรงสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความไวขวาง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความไวขวาง +\/-10% สูงสุด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความยาวสายสูงสุด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความยาวสายสูงสุด 305 เมตร (1,000 ฟุต) ระหว่างทรานสดิวเซอร์กับมอนิเตอร์ 3300 หรือ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการใช้งานและเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 องศาเซลเซียส ถึง +121 องศาเซลเซียส (-20 องศาฟาเรนไฮต์ ถึง +250 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความชื้นสัมพัทธ์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์สูงสุด 95% ไม่ควบแน่น; 100% ไม่จมเมื่อสั่งพร้อมสายไฟในตัว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุตัวเครื่องและอะแดปเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอลูมิเนียมอโนไดซ์ A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุแผ่นกันน้ำ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eนีโอพรีน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eวัสดุขั้วต่อ (ด้านบน\/ด้านข้าง)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอลูมิเนียมชุบแคดเมียม, นีโอพรีน และทองแดงชุบเงิน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแรงบิดติดตั้ง (ฐาน M10x1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eแรงบิดติดตั้ง 5.6 N\u003ci\u003em (50 in\u003c\/i\u003elb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความสูง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความสูงประมาณ 102 มม. (4 นิ้ว) (ขึ้นอยู่กับตัวเลือกขั้วต่อ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเส้นผ่านศูนย์กลาง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางประมาณ 41 มม. (1.6 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักประมาณ 300 กรัม (10.5 ออนซ์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขั้วต่อ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขา A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณขาออกบวก (จะเป็นบวกเมื่อเทียบกับขา B เมื่อความเร็วของตัวเครื่องเคลื่อนที่ไปทางขั้วต่อ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขา B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณขาออกลบ \/ สัญญาณกลับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจัดแนวการติดตั้ง:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าทรานสดิวเซอร์ถูกติดตั้งที่มุมการสอบเทียบที่กำหนด (45 องศาสำหรับตัวเลือก 02) เพื่อรักษาความแม่นยำของความถี่และความไว\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการใช้แรงบิด:\u003c\/strong\u003e ขันฐานติดตั้งแบบวงกลม M10x1 ให้แน่นที่ 5.6 N\u003ci\u003em (50 in\u003c\/i\u003elb) เท่านั้น การขันแน่นเกินไปอาจทำให้อุปกรณ์ภายในหรือเกลียวตัวเครื่องเสียหายได้\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเดินสายเคเบิล:\u003c\/strong\u003e หลีกเลี่ยงการเดินสายเคเบิลทรานสดิวเซอร์ขนานกับสายไฟแรงดันสูง AC เพื่อป้องกันการรบกวนแม่เหล็กไฟฟ้า (EMI) ที่เข้าสู่เส้นทางสัญญาณ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการป้องกันความชื้น:\u003c\/strong\u003e สำหรับการติดตั้งที่สัมผัสกับการล้างหนักหรือความชื้นสูง ให้ใช้ตัวเลือกสายไฟในตัวหรือปิดผนึกฝาครอบขั้วต่ออย่างเหมาะสมเพื่อป้องกันไม่ให้น้ำซึมเข้า\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eมาตรฐาน \/ การรับรอง\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN61326-1, อุปกรณ์ไฟฟ้าสำหรับการวัด, ควบคุม และใช้ในห้องปฏิบัติการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eคำสั่งของยุโรป\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eคำสั่ง EMC 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857193835,"sku":"9200-02-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-02-01-10-00-seismoprobe-velocity-transducers-252kh1riqh4_effdaec7-4446-4e7b-b85b-440c6de44474.jpg?v=1765449212"},{"product_id":"bently-nevada-9200-03-05-10-00-9200-series-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-03-05-10-00 9200 Series Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e is a 2-wire moving-coil velocity transducer engineered for the absolute vibration measurement of casing structures, bearing housings, or structural components. Operating on a self-generating electrodynamic principle, this \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e seismoprobe transforms mechanical velocity into a proportional voltage signal without requiring external excitation power. Its moving-coil design delivers robust resistance against false trips or signal degradation typically induced by impact, shock, or impulsive excitation near reciprocating or heavy rotating equipment. The transducer features a top-mounted terminal block interface for field electrical termination and mounts onto flat machine surfaces via a threaded stud, allowing direct integration into machinery protection systems, distributed control systems (DCS), or plant asset management monitors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodynamic moving-coil architecture providing high immunity to false trips caused by shock or high-frequency impact.\u003c\/li\u003e\n\u003cli\u003ePassive, self-generating design eliminates the need for external loop or module power supplies.\u003c\/li\u003e\n\u003cli\u003e2-wire electrical connectivity for straightforward field wiring and long-distance signal transmission.\u003c\/li\u003e\n\u003cli\u003eTop-mounted terminal block layout facilitates flexible configuration of regional field cables.\u003c\/li\u003e\n\u003cli\u003eRugged construction designed to maintain measurement fidelity under continuous machinery case vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHorizontal vibration monitoring on large industrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eBearing housing casing velocity measurements on steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eStructural monitoring of gearbox casings and support frames.\u003c\/li\u003e\n\u003cli\u003eCasing vibration tracking on industrial motors, generators, and blowers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: 9200 Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Angle Option: Horizontal (90 degrees +-2.5 degrees), 4.5 Hz minimum operating frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Option: Top-mount terminal block electrical connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: M10x1 threaded mounting stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals Option: No hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-03-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoving-Coil Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive electrodynamic (self-generating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) +-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 1,000 Hz (+0 dB, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal (90 degrees +-2.5 degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical (depending on connector option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.41 Nm (12.5 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Output (Velocity Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Output (Signal Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e Prepare a flat, clean, and smooth surface on the machine bearing housing or casing. Ensure the area is free of rust, paint, or grease to guarantee proper mechanical transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Threading:\u003c\/strong\u003e Secure the transducer tightly to the prepared surface utilizing the M10x1 threaded mounting stud. Tighten the base mounting stud to a torque specification of 5.6 Nm (50 in lb). Adhere strictly to this limit to prevent casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Verification:\u003c\/strong\u003e Align the transmitter strictly for horizontal operation (90 degrees +-2.5 degrees from vertical). Misalignment outside this window alters internal suspension physics and leads to severe measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e When attaching field wiring components, tighten the connector terminals to a specification of 1.41 Nm (12.5 in lb) to establish secure electrical contact without damaging the hardware threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e Use a high-quality, twisted 2-conductor shielded instrument cable to run signals from the top terminal block to the instrumentation rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect the cable shield wire cleanly to the instrumentation or monitor ground at the control room end only. Insulate the shield wire at the transducer terminal box to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact Prevention:\u003c\/strong\u003e Avoid hitting or dropping the transducer housing during installation procedures to safeguard the internal moving-coil mechanism from structural deformation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864140651,"sku":"9200-03-05-10-00 Transducer","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-03-05-10-00-transducer-ijg1gb5zujl_0d2232c9-47af-4f9b-9832-a31333d0d0bf.jpg?v=1765449391"},{"product_id":"bently-nevada-9200-01-02-10-00-seismoprobe-transducer","title":"Bently Nevada 9200-01-02-10-00 Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-01-02-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003eSeismoprobe Velocity Transducer\u003c\/strong\u003e designed to measure absolute casing vibration on rotating machinery. This moving-coil transducer provides a voltage output directly proportional to the vibration velocity of the machine housing. It operates without external power, utilizing a self-generating design that simplifies field wiring and integration into continuous monitoring systems. The \u003cstrong\u003e9200-01-02-10-00\u003c\/strong\u003e is typically connected to machinery protection systems, such as the Bently Nevada 3500 series, to provide continuous machinery diagnostics, early fault detection, and structural vibration evaluation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelf-generating, moving-coil design requires no external power source.\u003c\/li\u003e\n\u003cli\u003eTwo-wire connection configuration minimizes wiring complexity.\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity to low-frequency machinery casing vibration.\u003c\/li\u003e\n\u003cli\u003eDurable construction suitable for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eContinuous online monitoring capabilities for structural and casing velocity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge rotating machinery casing vibration monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial fans, blowers, and air handling units\u003c\/li\u003e\n\u003cli\u003eCentrifugal pumps and compressors\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine housing diagnostics\u003c\/li\u003e\n\u003cli\u003eElectric motor and gearbox structural analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e9200: Two-wire Seismoprobe Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e01: Standard Temperature Version\u003c\/li\u003e\n\u003cli\u003e02: Transducer Mount Option\u003c\/li\u003e\n\u003cli\u003e10: Minimum operating frequency option\u003c\/li\u003e\n\u003cli\u003e00: No Hazardous Area Approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSeismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e20 mV\/mm\/s (500 mV\/in\/s) plus or minus 5 percent at 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e10 Hz to 1000 Hz plus or minus 3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-29 to +121 Celsius (-20 to +250 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eVertical or horizontal based on option selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCase Material\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIntegral cable or top connector variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eEstimated Weight\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eApproximately 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eApprox. 41 mm diameter by 102 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePin A \/ Red Wire\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePositive (+) Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePin B \/ White Wire\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNegative (-) Signal \/ Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShield\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCase Ground \/ Shield Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e Ensure the transducer is mounted exactly within its specified orientation limits (vertical or horizontal) to maintain specified accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e The mounting surface must be flat, smooth, clean, and torque to the recommended engineering specification to ensure proper frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate the cable shield at the monitoring system chassis ground only. Do not connect the shield at the transducer end to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route transducer cables through dedicated conduit or cable trays away from high-voltage lines and heavy electrical machinery to reduce EMI\/RFI noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Apply proper environmental sealing or weatherproofing boots to the connector assembly when operating in high humidity or outdoor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core operating principle of the transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt utilizes a moving-coil and permanent magnet assembly that generates a voltage output directly proportional to the velocity of the physical vibration without external electrical power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model require an external proximity probe driver or transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a self-generating velocity sensor that interfaces directly with the processing monitor card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a vertical transducer is mounted horizontally?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal spring-mass assembly will misalign, causing internal friction, inaccurate readings, and potential damage to the internal coil suspension.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the cable shield be terminated for field installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shield must be insulated at the transducer housing and connected cleanly to the instrument ground inside the monitoring cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be repaired in the field if the housing is damaged?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is a factory-sealed unit and must be replaced or returned to the manufacturer for recalibration and service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical output impedance of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt features a low output impedance design making it suitable for driving long transmission cables without significant signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required during initial installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is factory-calibrated and does not require field adjustment, though periodic verification of the sensitivity parameter is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal distortion or clipping in this type of sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSevere mechanical shocks exceeding the physical limits of the internal mass suspension can cause internal bottoming and signal distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the transducer be painted during routine machinery maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePainting the sensor body is not recommended as it can trap heat, obscure identification labels, and potentially foul the mounting base coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does ambient temperature affect the sensitivity of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensitivity remains highly stable across the specified operating temperature range, with minor variance accounted for in the engineering verification data.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866794859,"sku":"9200-01-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-01-02-10-00-seismoprobe-transducer-akmea2itopi_2a477c9a-18b7-4ceb-998c-500cda761ba9.jpg?v=1765449481"},{"product_id":"bently-nevada-9200-06-05-10-00-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-06-05-10-00 Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-10-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e engineered for continuous monitoring or periodic measurements of absolute structural, casing, or bearing housing vibration. Operating via moving-coil technology, this system delivers a voltage output directly proportional to the mechanical vibration velocity without requiring an external power source. The \u003cstrong\u003e9200-06-05-10-00\u003c\/strong\u003e configuration is specifically less sensitive to impact or impulsive excitation compared to solid-state sensors, making it ideal for standard casing velocity applications across critical machinery like turbines, fans, and pumps.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire moving-coil technology design providing an direct voltage output without external power\u003c\/li\u003e\n\u003cli\u003eReduced sensitivity to impact or impulsive excitation compared to solid-state alternatives\u003c\/li\u003e\n\u003cli\u003eSuitable for both continuous machinery protection and periodic portable diagnostics\u003c\/li\u003e\n\u003cli\u003eHigh-grade anodized aluminum casing providing robust resistance to industrial environmental factors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and casing vibration measurement on rotating machinery\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine structural vibration monitoring\u003c\/li\u003e\n\u003cli\u003ePortable test instrument data collection and diagnostics\u003c\/li\u003e\n\u003cli\u003eBalance and misalignment tracking on heavy industrial fans and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: Circular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius with 25 mm\/s of casing vibration at 100 Hz under 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom 10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300\/3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block top mount (Polyphenylene Sulfide with nickel-plated copper contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Out (Signal goes positive with respect to B when case velocity moves toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignments:\u003c\/strong\u003e Ensure the transducer is installed strictly within its specified 0 ±100 vertical boundaries relative to the machine axis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Application:\u003c\/strong\u003e Tighten the M10X1 mounting base option to exactly 5.6 Nm (50 in-lb) during seating to preserve optimal amplitude and frequency response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Fidelity:\u003c\/strong\u003e Verify that structural or rotor vibration paths are faithfully transmitted to the bearing housing or casing location chosen for the transducer installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Countermeasures:\u003c\/strong\u003e Ensure the top-mounted terminal block enclosure is sufficiently protected against dust and moisture ingestion to fit local environmental ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9200-06-05-10-00 require an external power supply to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this transducer leverages a moving-coil architecture which inherently creates its own voltage signal output proportional to the vibration velocity without external power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency threshold for this precise configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit uses the -06 option, which defines a minimum operating frequency threshold of 10 Hz (600 cpm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the sensor signal cable be handled over long distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system supports up to 305 meters of leadwire between the velocity sensor and a 3300 or 3500 series monitor, though you should consult the manual for high-frequency roll-off parameters when using extended lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary differences between this moving-coil sensor and solid-state alternatives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMoving-coil sensors display much lower sensitivity to impact or impulsive excitations compared to embedded integration solid-state alternatives, providing specific advantages on designated casing installations.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867712363,"sku":"9200-06-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-10-00-velocity-seismoprobe-jzrvpejc0gv_9b3aa907-a1c6-44fd-96f1-814ed8ac1a38.jpg?v=1765449515"},{"product_id":"bently-nevada-74712-06-05-04-01-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-06-05-04-01 High-temperature Two-wire Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-reliability casing vibration monitoring on heavy industrial rotating machinery, the \u003cstrong\u003eBently Nevada 74712-06-05-04-01\u003c\/strong\u003e is a robust, high-temperature \u003cstrong\u003etwo-wire velocity transducer\u003c\/strong\u003e. This sensor is designed to withstand extreme thermal conditions while providing an accurate output proportional to vibration velocity, making it critical for predictive maintenance and machinery protection systems.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration features option \u003cstrong\u003e06\u003c\/strong\u003e for the mounting angle and minimum operating frequency, meaning it is calibrated for mounting at 0 +\/- 100 degrees with a 10 Hz (600 cpm) low-frequency cut-off. It incorporates the \u003cstrong\u003e05\u003c\/strong\u003e mounting base option, which provides a direct 1\/2-in 20 UNF-3A stud with no extra base adapter, and the \u003cstrong\u003e04\u003c\/strong\u003e side-mount connector arrangement. These parameters make the transducer ideal for tight spatial installations in harsh, high-heat environments like turbine decks or compressor housings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous operation in extreme thermal environments up to +204 degC.\u003c\/li\u003e\n  \u003cli\u003eTwo-wire design for direct integration with legacy and modern vibration monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eSide-mount connector layout (Option 04) for applications with minimal vertical clearance.\u003c\/li\u003e\n  \u003cli\u003eRugged casing construction designed to resist moisture, dust, and corrosive industrial elements.\u003c\/li\u003e\n  \u003cli\u003eDirect stud mounting via 1\/2-in 20 UNF-3A threaded stud (Option 05) for reliable mechanical coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine and gas turbine casing vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eBoiler feed pumps and high-temperature industrial fans.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical rotating machinery operating in extreme process areas.\u003c\/li\u003e\n  \u003cli\u003ePower generation and heavy manufacturing process lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e74712-06-05-04-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh-temperature Two-wire Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Angle \/ Minimum Frequency Option (06)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 +\/-100 degrees, 10 Hz (600 cpm) minimum operating frequency\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Base Option (05)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option (04)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSide-mount connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval Option (01)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard regional hazardous area approvals (detailed by option 01)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-29 degC to +204 degC (-20 degF to +400 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-29 degC to +204 degC (-20 degF to +400 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e82 mm (3.2 in) to 102 mm (4 in) typical (connector dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (4.4 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eSignal Positive (+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eSignal Negative (-) \/ Common Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the installation surface is flat, clean, and free of paint or debris to guarantee proper frequency response transmission.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the specified mounting angle window of 0 +\/- 100 degrees to prevent internal sensor damage and maintain calibration accuracy.\u003c\/li\u003e\n  \u003cli\u003eUse high-temperature rated cable assemblies when running wiring through zones exceeding +100 degC.\u003c\/li\u003e\n  \u003cli\u003eEnsure the side-mount connector is properly aligned and strain-relieved to prevent mechanical loading on the connection point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668277719403,"sku":"74712-06-05-04-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-04-01-slpuatreubv_22766029-ad60-4715-bcb8-029bc6ea5ef3.jpg?v=1765520305"},{"product_id":"bently-nevada-74712-01-10-02-00-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-01-10-02-00 74712 High-temperature Two-wire Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for demanding high-temperature vibration monitoring environments, the Bently Nevada 74712-01-10-02-00 industrial velocity transducer provides critical machine casing measurements. This self-generating, two-wire sensor is specifically designed to measure structural velocity on gas turbines, steam turbines, or other high-temperature rotating machinery. Operating on an electrodynamic moving-coil design, the \u003cstrong\u003eBently Nevada 74712-01-10-02-00\u003c\/strong\u003e provides a voltage output directly proportional to the vibration velocity, requiring no external power supply for signal generation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-Generating Design:\u003c\/strong\u003e Requires no external excitation power to generate the velocity voltage signal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Temperature Limit:\u003c\/strong\u003e Rated for sustained operation from -29 degC to +204 degC (-20 degF to +400 degF).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Mounting Angle:\u003c\/strong\u003e Configuration code 01 permits vertical mounting (0 +\/-2.5 degrees) with a 4.5 Hz (270 cpm) minimum operating frequency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Connection:\u003c\/strong\u003e Top-mount connector housing protects signal wires from harsh environment exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting Base:\u003c\/strong\u003e Features a circular M10X1 threaded connection base to ensure solid mechanical contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 20px;\"\u003e\n  \u003cli\u003eHeavy industrial gas turbines and steam turbine casings.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature power generation rotating assets.\u003c\/li\u003e\n  \u003cli\u003eProcess pumps, compressors, and exhaust fans in petro-chemical plants.\u003c\/li\u003e\n  \u003cli\u003eDraft fans and machinery operating in extreme thermal zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eOption Selection Decoding\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter Description\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSelected Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Angle \u0026amp; Min Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 +\/-2.5 degrees, 4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Base\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCircular M10X1 Thread\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConnector Orientation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTop Mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo Approvals Standard\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e74712-01-10-02-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTransducer Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eElectrodynamic Moving-Coil Velocity Transducer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-29 degC to +204 degC (-20 degF to +400 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFrequency Response Minimum\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eVertical (0 +\/-2.5 degrees)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e102 mm (4.0 in) typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Diameter\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Transducer Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg (4.4 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 74712 velocity transducer series serves as a specialized, self-generating alternative to standard Piezoelectric Velocity Transducers (PVTs) in superheated environments where active electronics would fail. Ensure your monitor channel cards (such as the Bently Nevada 3500\/42M) are explicitly configured to accept moving-coil (seismic) sensors. Attempting to run this on a standard accelerometer or IEPE channel configuration will produce signal clipping or no-reading errors.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eNever exceed the maximum structural temperature of 204 degC. Even though the body is designed for high temperatures, the interconnecting cabling must be insulated with FEP or glass braid. Avoid routing signal cabling along steam piping or unprotected thermal bridges without proper standoff brackets. Because this is a moving-coil sensor, physical drop damage can misalign the internal suspension springs, causing permanent sensitivity loss or signal distortion.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways verify that the mounting surface is machined flat to at least 0.02 mm (0.001 inches) and free of rust or slag. Tighten the sensor to the specified torque. Avoid over-torqueing, which can warp the base and degrade the transducer frequency response. Ensure the shielding drain wire is only grounded at the system monitor panel; grounding both ends can induce ground loop noise into your turbine casing measurements.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eEnsure the machine is completely de-energized, depressurized, and cooled to ambient levels before performing installation. Direct contact with hot casing surfaces can cause severe personal injury. De-energize all power lines in the conduit route to prevent accidental electrical shock.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInspect the machine casing mounting point. Ensure it matches the Circular M10X1 thread pattern and is drilled perpendicular to the casing surface to guarantee precise vertical alignment within the +\/-2.5 degree specification limit.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eApply a light film of high-temperature mounting lubricant to the base threads and mate the transducer manually. Threading should be smooth. Torque the unit to the mechanical specification using a calibrated hand torque wrench.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the high-temperature signal cable to the top mount connector. Ensure the cable is supported with adequate strain relief loops to prevent the weight of the conduit or cable bundle from stressing the connector housing.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668278604139,"sku":"74712-01-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-01-10-02-00-sz3tyyyns1o_4245b1f8-7625-40eb-b081-d203b3b5d2ff.jpg?v=1765520336"},{"product_id":"bently-nevada-9200-03-05-01-00-9200-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-03-05-01-00 9200 Two-wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eMonitoring absolute casing vibration is critical for detecting mechanical faults in large rotating machinery, and the \u003cstrong\u003eBently Nevada 9200-03-05-01-00\u003c\/strong\u003e provides the precise measurement required for these industrial environments. This self-generating, moving-coil \u003cstrong\u003etwo-wire velocity seismoprobe transducer\u003c\/strong\u003e converts mechanical vibration into a proportional voltage output without requiring any external excitation power. This specific configuration operates on a vertical axis, making it highly effective for continuous diagnostics on critical plant assets.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-01-00\u003c\/strong\u003e is built with an integrated circular base featuring a 1\/4-in 20 UNC stud for robust physical coupling to machine casings. The top-mounted terminal block connector allows for secure wiring directly within local terminal boxes. Because it operates down to a low minimum frequency of 4.5 Hz, it is capable of tracking slow-speed structural vibrations and unbalance conditions across various turbine and pump applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSelf-generating velocity sensor design operates without an external power source.\u003c\/li\u003e\n  \u003cli\u003eDesigned for vertical mounting orientations (90 degrees +\/-2.5 degrees tolerance).\u003c\/li\u003e\n  \u003cli\u003eLow-frequency response threshold starting at 4.5 Hz (270 cpm).\u003c\/li\u003e\n  \u003cli\u003eConvenient top-mounted terminal block for simplified and secure wiring.\u003c\/li\u003e\n  \u003cli\u003eRugged circular mounting base with a integrated 1\/4-in 20 UNC stud.\u003c\/li\u003e\n  \u003cli\u003eSealed, durable mechanical construction ideal for demanding industrial areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine and gas turbine casing vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eIndustrial pump and compressor casing diagnostic systems\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty electric motors and generators\u003c\/li\u003e\n  \u003cli\u003eDraft fans, cooling tower fans, and blowers\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery protection systems in power generation and chemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003e9200-03-05-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Series\u003c\/strong\u003e\n      \u003ctd\u003e9200 Seismoprobe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTransducer Type\u003c\/strong\u003e\n      \u003ctd\u003eTwo-wire Velocity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Angle Option\u003c\/strong\u003e\n      \u003ctd\u003e90 degrees +\/-2.5 degrees (Vertical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\n      \u003ctd\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConnector Option\u003c\/strong\u003e\n      \u003ctd\u003eTop-mount terminal block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Base\u003c\/strong\u003e\n      \u003ctd\u003eCircular; 1\/4-in 20 UNC stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHeight\u003c\/strong\u003e\n      \u003ctd\u003e10.2 cm (4.0 inches) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDiameter\u003c\/strong\u003e\n      \u003ctd\u003e4.1 cm (1.6 inches) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation is vital for ensuring accurate vibration signal transmission. The mounting surface on the machine casing must be clean, flat, and perpendicular to the axis of measurement. Thread the 1\/4-in 20 UNC mounting stud directly into the tapped hole and torque to standard engineering limits to prevent signal attenuation or sensor detachment. Align the sensor within the vertical mounting tolerance (90 degrees +\/-2.5 degrees). Use shielded, twisted-pair cabling to connect the terminal block to the monitoring system, ensuring the shield is grounded at the instrument end only to prevent ground loops.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296724843,"sku":"9200-03-05-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-05-01-00-2wvpki002wy_1e01400b-7f71-4866-976e-aebff3524321.jpg?v=1765520418"},{"product_id":"bently-nevada-9200-01-01-10-00-9200-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-01-01-10-00 9200 Two-Wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous machinery vibration monitoring, the \u003cstrong\u003e9200-01-01-10-00\u003c\/strong\u003e is a highly reliable \u003cstrong\u003evelocity seismoprobe transducer\u003c\/strong\u003e that measures absolute casing vibration. This two-wire, self-generating sensor converts mechanical vibration into an electrical voltage signal directly proportional to vibration velocity, eliminating the need for external excitation power.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration is optimized for vertical mounting orientations (0 degrees plus\/minus 2.5 degrees) and features a low-frequency capability down to 4.5 Hz (270 cpm). Engineered to withstand the demanding environments of heavy industrial facilities, the \u003cstrong\u003e9200-01-01-10-00\u003c\/strong\u003e provides critical diagnostic data for predictive maintenance programs on rotating machinery such as pumps, fans, and compressors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-Generating Design:\u003c\/strong\u003e Requires no external power supply to produce an output signal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo-Wire Interface:\u003c\/strong\u003e Simplifies wiring architecture and field installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTop Mount Connector:\u003c\/strong\u003e Provides convenient access for cable termination and routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Enclosure:\u003c\/strong\u003e Designed to withstand harsh industrial environments and high-vibration applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eIndustrial air compressors and blowers\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment pumps\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and refining rotating machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9200-01-01-10-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9200 Seismoprobe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Angle Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 plus\/minus 2.5 degrees\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTop Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCircular, M10 x 1 threaded stud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor accurate vibration measurement and long-term reliability, adhere to the following installation standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation:\u003c\/strong\u003e Ensure the transducer is mounted within plus\/minus 2.5 degrees of the true vertical position (0 degrees) as designated by the 01 mounting option.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Surface:\u003c\/strong\u003e The mounting surface must be clean, flat, and free of paint or debris to ensure proper mechanical transmission of vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Tighten the M10 x 1 stud to the manufacturer-specified torque limits using appropriate hand tools; do not overtighten.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Use flexible conduit or secure cable trays to protect the top-mount connector and signal line from mechanical wear or environmental hazards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307538283,"sku":"9200-01-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-01-01-10-00-k4x4przkfln_7d7ac32c-1d4c-4baa-a4be-151165031035.jpg?v=1765520720"},{"product_id":"bently-nevada-74712-03-10-02-00-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-03-10-02-00 74712 High-temperature Two-wire Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for demanding industrial environments, the \u003cstrong\u003eBently Nevada 74712-03-10-02-00\u003c\/strong\u003e operates as a rugged, high-temperature \u003cstrong\u003evelocity transducer\u003c\/strong\u003e designed to monitor machinery vibration. This continuous-duty, two-wire transducer is optimized for structural vibration measurements on critical rotating assets. To ensure precision tracking, this specific configuration features a 90-degree mounting angle paired with a low-frequency capability down to 4.5 Hz (270 cpm).\u003c\/p\u003e\n\n\u003cp\u003eThe mechanical housing incorporates a circular M10x1 mounting base for secure structural attachment, alongside a top-mount electrical connector. Capable of surviving extreme thermal conditions up to +204 degC, this transducer provides reliable, long-term vibration monitoring without the need for active external cooling, making it an ideal choice for high-temperature industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for continuous machinery vibration monitoring in high-temperature environments.\u003c\/li\u003e\n  \u003cli\u003eRobust two-wire loop design ensures simplified wiring and reliable signal transmission over long distances.\u003c\/li\u003e\n  \u003cli\u003e90-degree mounting orientation (±2.5 degrees tolerance) optimized for specific machinery axis tracking.\u003c\/li\u003e\n  \u003cli\u003eLow minimum operating frequency threshold of 4.5 Hz (270 cpm) for capturing low-speed machinery behavior.\u003c\/li\u003e\n  \u003cli\u003eCircular M10x1 threaded mounting base provides high-integrity mechanical coupling.\u003c\/li\u003e\n  \u003cli\u003eTop-mount connector alignment optimizes routing and protects cabling from surrounding mechanical interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature industrial fans and blowers\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and refinery rotating machinery\u003c\/li\u003e\n  \u003cli\u003ePulp and paper mills drying roll monitoring\u003c\/li\u003e\n  \u003cli\u003eIndustrial air compressors and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e74712-03-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e74712 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh-temperature Velocity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Angle \/ Frequency Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90 deg ±2.5 deg, 4.5 Hz (270 cpm) minimum operating frequency (Option 03)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCircular M10x1 (Option 10)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTop mount (Option 02)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo Approvals (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-29 degC to +204 degC (-20 degF to +400 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e102 mm (4 in) typical (dependent on connector installation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal signal response and mechanical stability, ensure the following engineering procedures are observed during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Alignment:\u003c\/strong\u003e Mount the transducer within its specified 90 deg ±2.5 deg mechanical tolerance. Misalignment beyond this envelope can degrade frequency performance and measurement accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Ensure the circular M10x1 mounting thread is tightened using appropriate torque tools to prevent loosening due to continuous machine vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Utilize the top-mount connector configuration to route cables away from hot surface areas, machinery joints, or sources of mechanical wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded cabling to preserve signal integrity and minimize electromagnetic interference (EMI) from nearby high-voltage machinery cables.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310782315,"sku":"74712-03-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-03-10-02-00-isha5hy0bo5_1c2c3394-8ab9-4995-9eb0-99e805f9f9b5.jpg?v=1765520848"},{"product_id":"bently-nevada-74712-06-12-04-cn-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-06-12-04-CN 74712 High-Temperature Two-Wire Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTo monitor casing vibration on high-temperature machinery such as gas turbines, steam turbines, and hot piping systems, industrial plants rely on the \u003cstrong\u003eBently Nevada 74712-06-12-04-CN\u003c\/strong\u003e. This specialized \u003cstrong\u003ehigh-temperature two-wire transducer\u003c\/strong\u003e integrates a moving-coil design that provides a voltage output directly proportional to vibration velocity. The self-generating design requires no external power source to operate the internal sensing element, making it highly reliable in extreme thermal environments. Engineered with an isolated circular base and side-mount connector layout, this unit integrates seamlessly with legacy and modern vibration monitoring systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-temperature design suitable for continuous operation on steam and gas turbine casings.\u003c\/li\u003e\n  \u003cli\u003eSelf-generating moving-coil mechanism eliminates the need for external active electronics at the measurement point.\u003c\/li\u003e\n  \u003cli\u003eTwo-wire connection configuration simplifies field wiring and reduces installation complexity.\u003c\/li\u003e\n  \u003cli\u003eIsolating mounting base minimizes electrical noise and ground loop interference.\u003c\/li\u003e\n  \u003cli\u003eSide-mount connector configuration provides low-profile installation clearance in tight industrial spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGas turbine casing vibration monitoring.\u003c\/li\u003e\n  \u003cli\u003eSteam turbine housing and bearing block measurement.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature industrial fans, blowers, and pumps.\u003c\/li\u003e\n  \u003cli\u003eHeat-exchanger and piping system structural vibration analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e74712-06-12-04-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHigh-Temperature Two-Wire Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Angle \/ Minimum Operating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 +\/-100 degrees, 10 Hz (600 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIsolated circular base 1\/2-in 20 UNF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSide mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCN (Approvals country specific)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.48 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting surface is clean, flat, and free of paint or debris to guarantee accurate vibration transmission. Torque the mounting stud to the specified OEM tolerance to avoid sensor distortion or loose coupling. Route the side-mounted connection cable with sufficient strain relief and bend radius to prevent mechanical wear in high-vibration zones. Utilize shielded, twisted-pair cabling to protect the signal from electromagnetic interference (EMI).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668313305451,"sku":"74712-06-12-04-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-12-04-cn-4egbitpt2vi_d289181f-977e-48de-bb85-bdd929ffdbeb.jpg?v=1765520925"},{"product_id":"74712-06-05-02-00-bently-nevada-seismoprobe-velocity-transducer","title":"74712-06-05-02-00 Bently Nevada Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for continuous machinery vibration monitoring in demanding industrial thermal conditions, the \u003cstrong\u003eBently Nevada 74712-06-05-02-00\u003c\/strong\u003e provides precise case velocity measurements on critical rotating machinery. This high-temperature, two-wire transducer operates on moving-coil design principles, generating a voltage proportional to the vibration velocity without requiring external power. The specific configuration of this \u003cstrong\u003e74712 Seismoprobe\u003c\/strong\u003e model makes it highly suitable for structural vibration analysis on gas turbines, steam turbines, pumps, and fans where operating temperatures exceed standard sensor limits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo-Wire Construction:\u003c\/strong\u003e Simplifies wiring infrastructure and integrates directly with traditional machinery protection systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHorizontal Optimization:\u003c\/strong\u003e Calibrated for a horizontal mounting orientation (0 deg plus\/minus 100 deg) with a 10 Hz minimum operating frequency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Stud Mount:\u003c\/strong\u003e Direct attachment via a 1\/2-20 UNF-3A stud, maximizing mechanical high-frequency transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTop-Mount Connector:\u003c\/strong\u003e Minimizes overall physical clearance requirements in tight machine enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-temperature exhaust fans and industrial blowers\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty steam and gas turbine bearing housing monitoring\u003c\/li\u003e\n  \u003cli\u003eMain boiler feed pumps and safety-critical pumping systems\u003c\/li\u003e\n  \u003cli\u003eRotary compressors and high-speed gearboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOption Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eSelected Configuration Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e06\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Angle \/ Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 deg +\/- 100 deg, 10 Hz (600 cpm) minimum operating frequency\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e05\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Base\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo base; 1\/2-20 UNF-3A stud connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e02\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConnector Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTop Mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo Approvals\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e74712 High-Temperature Seismoprobe\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFull Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e74712-06-05-02-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTransducer Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSelf-generating, moving-coil velocity sensor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Angle\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 deg +\/- 100 deg (Horizontal mounting target)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMinimum Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10 Hz (600 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMechanical Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1\/2-20 UNF-3A integral stud mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eElectrical Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTop-mounted multi-pin connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eHazardous Area Certifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNone (Option 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTransducer Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e480 grams (17 ounces) typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kg (3.3 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 74712 series serves as a specialized, high-temperature replacement for standard velocity sensors such as the Bently Nevada 9200. Ensure that the associated monitoring system configuration (e.g., Bently Nevada 3500\/42M) matches the expected electrical characteristics and low-frequency cut-off values of the 74712 transducer.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"06\" option dictates a horizontal mounting angle constraint. Attempting to install this unit vertically (90 degrees relative to horizontal) will cause the internal moving coil to rest off-center, leading to signal clipping, measurement errors, and premature internal mechanical wear. Operating temperature ranges must be kept within the physical limits of the transducer's internal assemblies to prevent coil insulation degradation.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen routing cables from the top-mount connector, provide an adequate drip loop and strain relief. High-temperature environments generate mechanical stress, so armored, shielded cables should be securely tied down to structural points nearby rather than being allowed to hang from the connector head.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate the machine and ensure it is in a zero-energy state before drilling, tapping, or mounting the sensor. Physical impact or excessive torque applied directly to the transducer body during installation can permanently damage the internal moving-coil alignment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 0.875rem;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePrepare a clean, flat surface on the bearing housing perpendicular to the desired measurement axis.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 0.875rem;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the mounting thread matches the 1\/2-20 UNF-3A stud specification precisely.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 0.875rem;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eApply thread-locking compound if required by plant specifications, and torque the transducer base using the flat wrench surfaces only. Do not torque by gripping the sensor body.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 12px; font-weight: bold; font-size: 0.875rem;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAttach the top-mount connector and secure the cable shield to the designated monitoring rack ground to prevent electro-magnetic interference.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314222955,"sku":"74712-06-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-02-00-cyfd3iyjgjv_e560f033-a3e4-4963-8b71-d4bfa39ab199.jpg?v=1765520958"},{"product_id":"bently-nevada-9200-03-05-10-00-9200-series-two-wire-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-03-05-10-00 9200 Series Two-Wire Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for continuous machinery vibration monitoring, the \u003cstrong\u003eBently Nevada 9200-03-05-10-00\u003c\/strong\u003e functions as a self-generating, two-wire velocity sensor that translates casing vibration into an electrical signal. This moving-coil transducer is engineered specifically for vertical installation configurations, operating at a 90-degree angle to provide high-precision measurements of absolute structural vibration on bearing housings, casings, or structural supports. By utilizing a passive design, this transducer operates without external power, converting physical motion directly into an AC voltage output proportional to vibration velocity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelf-Generating Operation:\u003c\/strong\u003e Moving-coil configuration requires zero external excitation voltage or auxiliary power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVertical Orientation Calibration:\u003c\/strong\u003e Factory-calibrated for 90 degrees (plus\/minus 2.5 degrees) mounting angles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Frequency Capability:\u003c\/strong\u003e Minimum operating frequency rating of 4.5 Hz (270 cpm) for capturing low-speed machinery defects.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Interface:\u003c\/strong\u003e Top-mounted terminal block connection eliminates molded cable dependencies for field-terminated wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Mounting Interface:\u003c\/strong\u003e Features a circular base equipped with an M10x1 stud for high-frequency transmission.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eVertical industrial pumps and motor casing vibration monitoring\u003c\/li\u003e\n  \u003cli\u003eLarge fans, blowers, and air-handling equipment maintenance paths\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator bearing housing structural tracking\u003c\/li\u003e\n  \u003cli\u003eCasing vibration measurements on steam and gas turbines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; font-size: 14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9200-03-05-10-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTransducer Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTwo-wire moving-coil velocity transducer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Angle Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e90 degrees plus\/minus 2.5 degrees (Vertical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMinimum Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnection Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTerminal block, top mount (no cable included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Base\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCircular base with M10x1 threaded stud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOption 00 (No hazardous area approvals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe top-mounted terminal block option simplifies on-site wiring without requiring proprietary molded connector cables. Ensure proper polarity connections to preserve signal phase relative to machinery vibration direction.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; font-size: 14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTerminal designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSignal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eA (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSignal Positive (High side of coil)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eB (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSignal Negative (Low side of coil \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShield \/ Case Ground\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCable shield termination (to be isolated at the sensor case and grounded at the monitor end only)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 9200 series moving-coil Seismoprobe is a legacy mechanical design. It is highly valued because it does not require external power loops, unlike modern solid-state piezo-velocity sensors (such as the Bently Nevada 330500 Velomitor). If you are replacing a 9200 unit, you must match the mounting angle option exactly. A vertical \"-03\" model (90 degrees) cannot be replaced with a horizontal \"-01\" or \"-02\" model, as the internal spring suspension is physically tuned to counteract gravity only at the specified operating orientation.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eCross-axis sensitivity is a known limitation of moving-coil transducers. To prevent physical wear on the internal coil guide and to avoid false signal generation, the sensor must not deviate more than plus\/minus 2.5 degrees from the vertical axis. Additionally, check for nearby magnetic fields; because the 9200 uses an internal permanent magnet and moving coil, high-power magnetic fields from adjacent large motors can induce noise directly into the signal path.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen wiring to the terminal block, prevent dynamic stress on the terminals by installing a physical strain relief clamp within 100 mm of the sensor head. This prevents wiring fatigue from continuous structural vibration. Always use twisted, shielded cable (typically 18 AWG to 22 AWG) and ensure the shield is floated at the sensor and grounded at the rack monitor to mitigate ground loop noise.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to installation or replacement, ensure that all machinery is safely locked out and de-energized. Do not mount the transducer on surfaces that exceed the maximum rated thermal capacity of the unit, as overheating can permanently demagnetize the internal moving-coil system, causing permanent sensitivity loss.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003ePrepare the mounting surface. It must be flat, smooth, and free of paint, rust, or debris. A surface finish of 1.6 micrometers (63 microinches) or better is recommended.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eApply an approved thread-locking compound to the M10x1 stud threads. Thread the sensor onto the mounting hole and torque to the manufacturer's specification using a flat wrench on the housing hex flats (do not hand-tighten by twisting the terminal head).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eConfirm vertical alignment using a precision level or inclinometer. The deviation from vertical must be less than 2.5 degrees.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eConnect the field wiring to the terminal block. Secure the cable with local flexible conduit or strain-relief clamps to prevent mechanical fatigue on the connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314714475,"sku":"9200-03-05-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-05-10-00-ddmttupc3g2_bf51cf0e-e4e8-4147-b598-f31196a66de4.jpg?v=1765520975"},{"product_id":"bently-nevada-74712-01-10-03-00-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-01-10-03-00 High-temperature Two-wire Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to capture dynamic casing vibration in demanding thermal environments, the \u003cstrong\u003eBently Nevada 74712-01-10-03-00\u003c\/strong\u003e operates as a high-reliability, self-generating velocity transducer. This specialized industrial sensor translates structural physical motion into a proportional two-wire current loop, enabling direct interfacing with diagnostic instruments, distributed control systems (DCS), and continuous machinery protection architectures. By utilizing a \u003cstrong\u003eself-generating moving-coil design\u003c\/strong\u003e, the unit minimizes active components in high-heat zones, ensuring long-term structural integrity and precise signal fidelity without requiring external power at the point of measurement.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Temperature Resilience:\u003c\/strong\u003e Engineered to withstand sustained operational temperatures up to 204 degC (400 degF).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eTwo-Wire Interface:\u003c\/strong\u003e Streamlines field wiring requirements by utilizing a robust two-wire current-loop telemetry format.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eSelf-Generating Mechanism:\u003c\/strong\u003e Requires no external excitation power to operate the primary velocity sensing coil.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eTop-Mount Terminal Block:\u003c\/strong\u003e Provides a simplified connection point that eases field wiring termination and routine maintenance checks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eLow-Frequency Optimization:\u003c\/strong\u003e Calibrated with a 4.5 Hz (270 cpm) minimum operating frequency threshold for tracking low-speed machinery dynamics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCasing vibration monitoring on industrial gas turbines and steam turbine housings.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eContinuous predictive maintenance on high-temperature boiler feed pumps and draft fans.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMechanical health monitoring of heavy-duty petrochemical process compressors and gearboxes.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eStructural vibration tracking in heat-treatment and primary metal manufacturing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eOption Selection\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eOption Description\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eConfigured Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTransducer Mounting Angle \u0026amp; Min Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 degrees +\/-2.5 degrees, 4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e10\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMounting Base Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCircular M10x1 thread style\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e03\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConnector Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTop-mounted terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo agency approvals\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eEngineering Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e74712-01-10-03-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHigh-temperature Two-wire Velocity Transducer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Orientation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVertical (0 degrees +\/-2.5 degrees)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMinimum Operating Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4.5 Hz (270 cpm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-29 degC to +204 degC (-20 degF to +400 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCasing Diameter\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSensor Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e102 mm (4 in) typical (dependent on terminal block)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Transducer Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.00 kg (4.41 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States of America (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 74712-01-10-03-00 utilizes an \"01\" mounting option, constraining its measurement path strictly to a vertical orientation (0 degrees +\/-2.5 degrees). If horizontal machinery surfaces require monitoring, a different option code must be specified to align the internal spring-mass system with the correct axis of gravity. It functions as a direct field replacement for legacy 74712 units with identical suffix configurations, ensuring seamless mounting footprint integration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating near the upper thermal limit of 204 degC requires careful consideration of mechanical cable ratings. Standard PVC-jacketed field wiring will fail rapidly under these conditions; always utilize high-temperature fluoropolymer (PTFE\/Teflon) jacketed shielded cables. In high-vibration environments, ensure the M10x1 mounting base is torqued according to OEM specifications to prevent thread loosening and signal attenuation.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe top-mounted terminal block (Option 03) simplifies connections but exposes the termination points to ambient airborne contaminants. Use high-integrity industrial conduit or protective terminal covers when deploying in environments with conductive dust or oil mist. Ensure that the shield drain wire is isolated at the sensor head and grounded exclusively at the monitoring system cabinet to prevent artificial ground loops from distorting critical phase or amplitude measurements.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING: SAFETY FIRST\u003c\/p\u003e\n  \u003cp style=\"margin: 5px 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003eBefore beginning mechanical installation or terminal wiring, ensure the target machinery is completely de-energized, locked out, and tagged out (LOTO). Verify that local process temperatures at the mounting point have cooled to a safe handling range to prevent severe thermal burns.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInspect the machinery mounting location, ensuring the surface is machined flat and tapped perpendicular with the correct M10x1 mating threads.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eApply a light film of high-temperature anti-seize lubricant strictly to the mounting stud threads, avoiding any excess that could contaminate electrical contact zones.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eThread the transducer mounting base manually into the pre-tapped hole. Tighten to the specified installation torque using a calibrated deep-well socket to avoid damaging the sensor's outer casing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTerminate the shielded twisted-pair cabling to the top terminal block. Ensure that lead wire jackets are stripped cleanly without nicking the conductors, and secure the conduit connections to isolate the assembly from structural stress.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668316025195,"sku":"74712-01-10-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-01-10-03-00-m3zjpa1myws_880ef928-4296-4e06-b0b1-a06f38790aae.jpg?v=1765521023"},{"product_id":"bently-nevada-9200-01-02-02-00-two-wire-transducer","title":"Bently Nevada  9200-01-02-02-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 9200-01-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-wire vibration transducer designed for continuous measurement of machinery vibration in pumps, fans, compressors, and general-purpose industrial rotating equipment. It provides a compact and cost-effective monitoring solution for condition-based maintenance systems where full proximity probe architecture is not required.\u003c\/p\u003e\n\u003cp\u003eThis transducer is widely used in auxiliary machinery protection systems across power plants, water treatment facilities, and process industries. It converts mechanical vibration into a proportional electrical signal suitable for direct connection to monitoring and control systems.\u003c\/p\u003e\n\u003cp\u003eThe side-mount connector and circular 1\/4 in 28 UNF stud base support flexible installation on standard machine housings, ensuring stable mechanical coupling and consistent vibration transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9200\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMounting angle and minimum operating frequency option (0 ±2.5, 4.5 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eSide-mount connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eCircular base with 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines mechanical orientation, connector position, and mounting interface within the 9200 series transducer architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-01-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire vibration transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eSide mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003eCircular, 1\/4 in 28 UNF stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz minimum (270 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle\u003c\/td\u003e\n\u003ctd\u003e0 ±2.5 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eTwo-wire loop powered system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe two-wire design simplifies installation by combining power supply and signal transmission in a single loop configuration. This reduces wiring complexity in distributed monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe circular stud mounting base ensures stable mechanical coupling to machine surfaces, which is critical for accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003eLow-frequency response capability allows monitoring of slow-speed machinery where traditional high-frequency sensors may not provide sufficient sensitivity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this transducer typically used?\u003c\/strong\u003e\u003cbr\u003eIt is used in general industrial machinery such as pumps, fans, and auxiliary compressors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for high-speed turbine monitoring?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for general-purpose machinery, not high-precision turbine proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of two-wire design?\u003c\/strong\u003e\u003cbr\u003eIt reduces wiring complexity by combining signal and power in a single loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in legacy monitoring systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in retrofit and general-purpose condition monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure solid mechanical mounting using the 1\/4 in 28 UNF stud to guarantee accurate vibration transmission from machine surface to sensor body.\u003c\/p\u003e\n\u003cp\u003eAvoid loose mounting conditions, as poor mechanical coupling directly affects signal accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute transducer wiring away from high-voltage and motor drive cables to minimize electrical noise interference.\u003c\/p\u003e\n\u003cp\u003eVerify correct loop power configuration before commissioning to ensure stable signal output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper surface preparation before installation to ensure flat and stable mounting contact.\u003c\/p\u003e\n\u003cp\u003eUse torque-controlled tightening for stud mounting to prevent mechanical stress damage to the housing.\u003c\/p\u003e\n\u003cp\u003eAvoid installing in areas with excessive structural resonance that may distort vibration readings.\u003c\/p\u003e\n\u003cp\u003ePeriodically inspect mounting integrity in high-vibration environments to ensure long-term measurement stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321268075,"sku":"9200-01-02-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-01-02-02-00-lyutop23y3j_d66bbd30-1837-4d70-a2d9-9f4778f18244.jpg?v=1765521151"},{"product_id":"bently-nevada-9200-03-24-10-00-two-wire-velocity-seismoprobe-transducer","title":"Bently Nevada 9200-03-24-10-00 Two-wire Velocity Seismoprobe Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200-03-24-10-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etwo-wire velocity Seismoprobe transducer from Bently Nevada is designed for continuous vibration monitoring of industrial rotating and reciprocating machinery. It is widely used in power generation plants, oil and gas facilities, compressors, pumps, and heavy industrial systems where accurate vibration measurement is required to ensure machine reliability and reduce unplanned downtime.\u003c\/p\u003e\n\u003cp\u003eThis velocity transducer operates on a two-wire configuration, simplifying field wiring while maintaining stable signal transmission for condition monitoring systems. The mounting configuration supports a circular M10x1 stud, providing secure mechanical installation in industrial environments with high vibration levels. The 90 degree ±2.5 mounting angle option and 4.5 Hz minimum operating frequency ensure stable low-frequency response for slow-speed machinery applications. The environmentally resistant integral cable connector allows direct installation in exposed environments. With a compact body design and rugged construction, the device maintains consistent performance under harsh operational and thermal conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode Segment\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eMounting angle 90 degree ±2.5, minimum operating frequency 4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eEnvironmentally resistant connector with integral cable (custom length 2.1 m to 15 m range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eCircular mounting base with M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-03-24-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eCircular base M10x1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Angle\u003c\/td\u003e\n\u003ctd\u003e90 deg ±2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eIntegral cable, environmentally resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Range\u003c\/td\u003e\n\u003ctd\u003e2.1 m to 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e102 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e41 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eVelocity vibration sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a two-wire velocity transducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt simplifies installation by reducing wiring complexity while maintaining reliable vibration signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transducer be used in low-speed machinery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports a low-frequency response down to 4.5 Hz, suitable for slow-speed equipment monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable length adjustable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The integral cable option supports lengths from 2.1 m up to 15 m depending on installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for outdoor industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The environmentally resistant connector and rugged housing support harsh field conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure the mounting stud is tightened according to manufacturer torque specifications to maintain accurate vibration coupling.\u003c\/p\u003e\n\u003cp\u003eRoute signal cables away from high voltage and VFD lines to reduce electromagnetic interference in vibration measurement systems.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief to prevent connector fatigue in high vibration installations.\u003c\/p\u003e\n\u003cp\u003eAvoid installing near high thermal radiation sources to preserve sensor stability and long-term accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322349419,"sku":"9200-03-24-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-03-24-10-00-kul4bizo52s_0af56f41-8cb1-467a-aa7e-5c3c3e17f1b5.jpg?v=1765521195"},{"product_id":"bently-nevada-74712-06-05-03-00-74712-high-temperature-two-wire-transducer","title":"Bently Nevada 74712-06-05-03-00 | 74712 High-Temperature Two-Wire Transducer","description":"\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eis a heavy-duty, high-temperature two-wire seismic vibration transducer engineered for aggressive machinery protection systems. This specialized sensor is primarily deployed in gas and steam turbine power plants, petrochemical refineries, and heavy steel mills where standard vibration probes fail due to excessive ambient heat. By generating a continuous, proportional velocity signal from critical rotating machinery castings and bearing housings, it provides instant diagnostic visibility. Installing this highly stable seismic sensor ensures real-time detection of structural imbalance, mechanical looseness, and bearing degradation. This predictive monitoring directly mitigates catastrophic failures, extends operational runtimes, and prevents costly unplanned downtime in critical high-heat processes.\u003c\/p\u003e\n\u003ch3\u003eCode Allocation \u0026amp; Suffix Decoupling\u003c\/h3\u003e\n\u003cp\u003eThe specialized model number structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseismic transducer translates to the following factory mechanical configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model designation for the Bently Nevada High-Temperature Two-Wire Seismic Transducer series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: Transducer Mounting Angle\/Minimum Operating Frequency Option specifying a 0 plus\/minus 100 degrees mounting orientation with a 10 Hz (600 cpm) minimum operating frequency threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Mounting Base Option designating no integrated base, utilizing a standard 1\/2-in 20 UNF-3A mounting stud.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Connector Option featuring a ruggedized, top-mounted integrated terminal block for simplified field wire connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option denoting a standard, non-certified build for non-hazardous industrial areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertified Mechanical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Metric Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeismic Velocity (Two-wire loop powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Angle Orientation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 plus\/minus 100 degrees vertical alignment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Operating Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A stud (no base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTop-mount terminal block connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Housing Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Core Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (including rugged shock-absorbent packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Diagnostics \u0026amp; Integration FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary operational advantage of the 10 Hz (600 cpm) low-frequency limit specified by Option 06?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 10 Hz low-frequency limit enables the sensor to accurately monitor low-speed structural vibrations and bearing casing movements common in heavy industrial machinery, filtering out slow-frequency thermal expansion while preserving high-frequency rotational data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the top-mounted terminal block option simplify installation compared to integrated cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"03\" top-mount terminal block design allows field technicians to terminate existing industrial field cabling directly onto the sensor body. This eliminates the need for expensive molded proprietary connectors and simplifies cable replacements in tight, high-temperature conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this transducer be mounted in any orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \"06\" option limits the functional orientation to 0 plus\/minus 100 degrees (typically vertical or near-vertical). Mounting this transducer outside of this specified angular tolerance will cause the internal seismic mass to drift off-center, leading to inaccurate readings and physical internal wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Manual\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Mechanical Coupling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the mounting surface of the machine housing is flat, clean, and free of paint or rust before mounting. Thread the 1\/2-in 20 UNF-3A mounting stud into the machine casing. Apply a thin layer of silicone grease to the mating surfaces and tighten the transducer to the recommended installation torque to ensure perfect acoustic coupling for dynamic vibration transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Cable Strain Relief:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring the top-mounted terminal block in extreme temperature zones, use high-temperature rated, shielded twisted-pair cabling. Provide a generous cable loop (strain relief) immediately exiting the terminal block to prevent high-amplitude mechanical vibration from putting physical stress on the wire termination screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Ground Loop Prevention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the cable shield wire to the instrument common ground at the monitor or DCS end only. Do not ground the cable shield at the transducer terminal block or machine casing. This single-point grounding layout prevents ground loops and blocks electromagnetic interference (EMI) from adjacent high-power motor drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668323561835,"sku":"74712-06-05-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-03-00-5nhmfoh3mdd_5c3f81cf-6735-4129-b6ef-4b0b7c8cff34.jpg?v=1765521236"},{"product_id":"74712-06-05-04-00-bently-nevada-high-temperature-two-wire-transducer","title":"74712-06-05-04-00 Bently Nevada High-Temperature Two-Wire Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, high-temperature seismic velocity transducer engineered by Bently Nevada for the most demanding industrial environments. Specifically designed to monitor vibration on gas turbines, steam turbines, and other rotating machinery where surface temperatures exceed the limits of standard sensors, this two-wire transducer provides a self-generated electrical signal proportional to vibration velocity. Its robust construction ensures reliable performance in the high-heat zones of power generation and petrochemical facilities, allowing for continuous monitoring of critical assets to prevent costly mechanical failure and extend the Mean Time Between Failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003eSuffix Logic Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe specific hardware configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by the following industrial options:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e74712\u003c\/strong\u003e: Base model for the High-Temperature Two-Wire Velocity Transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-90\"\u003e\u003c\/span\u003e\u003cstrong\u003e06 (Mounting Angle\/Freq Option)\u003c\/strong\u003e\u003cspan class=\"citation-90 citation-end-90\"\u003e: Optimized for a mounting angle of 0 plus or minus 100 degrees, with a minimum operating frequency of 10 Hz (600 cpm).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Mounting Base Option)\u003c\/strong\u003e: Supplied without a base; features a direct 1\/2-in 20 UNF-3A integrated stud for rigid mechanical coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Connector Option)\u003c\/strong\u003e: Configured with a side-mount connector interface, ideal for installations with limited vertical overhead clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option)\u003c\/strong\u003e: Standard non-certified version for general industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74712-06-05-04-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-Wire Velocity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin Operating Freq\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz (600 cpm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Angle\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 +\/- 100 degrees\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Stud\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-in 20 UNF-3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSide Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41 mm (1.6 in) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg (1.06 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn what specific scenarios is a side-mount connector (Option 04) preferred?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe side-mount configuration is critical for turbine housings or bearing pedestals where the surrounding heat shielding or acoustic enclosures provide insufficient vertical space for a top-exit cable. It also assists in creating a natural \"drip loop\" to prevent moisture from following the cable into the connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transducer require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-89\"\u003eAs a velocity transducer based on moving-coil technology, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan class=\"citation-89 citation-end-89\"\u003e\u003cspan\u003e \u003c\/span\u003eis self-generating.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt converts mechanical vibration directly into a voltage signal, which simplifies field wiring and reduces the risk of electronic component failure in high-heat zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 10 Hz minimum frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis frequency rating ensures the sensor is tuned to capture the fundamental rotational speeds and primary harmonics of large-scale turbines (600 rpm and above). It is not recommended for very slow-speed machinery where frequencies drop below 10 Hz.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Isolation and Cable Selection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74712-06-05-04-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high temperatures, the longevity of the installation depends heavily on the cabling. Always use high-temperature TFE-insulated shielded cables. Ensure the side-mount connector is securely tightened and, if necessary, protected by a heat-reflective sleeve to prevent localized \"hot spots\" from degrading the connector seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1\/2-in 20 UNF stud (Option 05) provides a massive, rigid connection point necessary for accurate seismic vibration transmission. Ensure the mounting surface is machined flat to a 0.001-inch total indicator reading. Apply appropriate torque to prevent the sensor from loosening under high-vibration conditions, as any \"sensor rattle\" will manifest as high-frequency noise in the vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation Awareness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"06\" option is designed for near-horizontal mounting. Significant deviation from the specified mounting angle (outside the +\/- 100-degree range) can cause the internal moving coil to contact the housing walls, resulting in \"clipped\" signals and inaccurate vibration readings. Always verify the machine surface angle before installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668324053355,"sku":"74712-06-05-04-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/74712-06-05-04-00-g0ib0cc4duz_7b5a4c3a-dec7-4315-957f-3f91417ce102.jpg?v=1765521256"},{"product_id":"bently-nevada-9200-10-01-10-00-two-wire-transducer","title":"Bently Nevada 9200-10-01-10-00 Two-wire Transducer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe 9200-10-01-10-00 is a two-wire transducer designed for continuous vibration and condition monitoring. It supports stable signal transmission using a simple two-wire configuration. Moreover, it is suitable for permanent installation in industrial machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e9200-10-01-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin (COO)\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Angle \/ Min Operating Frequency\u003c\/td\u003e\n\u003ctd\u003eOption 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Option\u003c\/td\u003e\n\u003ctd\u003e01 = Top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base Option\u003c\/td\u003e\n\u003ctd\u003e10 = Circular base, M10 × 1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00 = No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Configuration\u003c\/td\u003e\n\u003ctd\u003eStud-mounted transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePermanent installation on rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial asset protection applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668329984363,"sku":"9200-10-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/9200-10-01-10-00-ow5ndtwc2ed_67e75373-b998-4e38-a061-173aebb38270.jpg?v=1765521408"}],"url":"https:\/\/www.plcprotech.com\/th\/collections\/bently-nevada-9200-74712-two-wire-transducer.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}