{"title":"Bently Nevada Vibration Transmitters","description":"\u003cp\u003eBently Nevada Vibration Transmitters provide a cost-effective method for integrating vibration monitoring directly into a PLC or DCS without a dedicated monitor rack. The architecture centers on a loop-powered device that converts transducer signals—from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-velocity-sensors-accelerometers\"\u003evelocity sensors\u003c\/a\u003e or \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximity-probe\"\u003eproximity probes\u003c\/a\u003e—into a standard 4-20 mA output. Technical characteristics include rugged DIN-rail mountable designs and hazardous area certifications. Functionally, these transmitters enable plant operators to receive continuous machinery health data for \"balance of plant\" equipment like motors and blowers. By simplifying the signal chain, they provide essential protection and trending capabilities, often used alongside \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3300-xl-proximitor-sensor\"\u003e3300 XL sensors\u003c\/a\u003e to facilitate an integrated approach to plant-wide condition monitoring and predictive maintenance strategies.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-991-06-70-01-05-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-06-70-01-05 991 ทรัสต์ ทรานสมิตเตอร์","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-06-70-01-05\u003c\/strong\u003e เป็นเครื่องส่งแรงดันแบบสองสายที่ใช้พลังงานลูป ออกแบบมาเพื่อวัดตำแหน่งแกนหมุนสัมพัทธ์ในแนวแกนของเครื่องจักรหมุน รับสัญญาณอินพุตจาก \u003cstrong\u003eโพรบใกล้เคียง 3300 NSv\u003c\/strong\u003e และสายต่อขยาย แปลงสัญญาณโพรบใกล้เคียงเป็นเอาต์พุตกระแส 4 ถึง 20 mA ที่สัดส่วนตรง อุปกรณ์นี้สามารถเชื่อมต่อโดยตรงกับโปรแกรมเมเบิลลอจิกคอนโทรลเลอร์ (PLC), ระบบควบคุมแบบกระจาย (DCS) และเครือข่าย SCADA เพื่อให้การปกป้องเครื่องจักรและการตรวจสอบสภาพอย่างต่อเนื่อง การใช้งานในอุตสาหกรรมทั่วไป ได้แก่ กังหันไอน้ำขนาดเล็ก ปั๊ม พัดลม และเครื่องอัดที่ไม่ต้องการแร็คระบบปกป้องเครื่องจักรเต็มรูปแบบ\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเอาต์พุตกระแสลูป 4 ถึง 20 mA สองสายที่ใช้พลังงานลูป\u003c\/li\u003e\n\u003cli\u003eออกแบบมาเพื่อวัดการเคลื่อนที่แกนหมุนแบบไม่สัมผัส\u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับ \u003cstrong\u003eโพรบใกล้เคียง 3300 NSv\u003c\/strong\u003e และสายต่อขยาย\u003c\/li\u003e\n\u003cli\u003eตัวเชื่อมต่อ BNC ในตัวสำหรับการเข้าถึงสัญญาณสั่นสะเทือนไดนามิกและการวินิจฉัย\u003c\/li\u003e\n\u003cli\u003eการติดตั้งแบบราง DIN หรือแผง\u003c\/li\u003e\n\u003cli\u003eการปรับศูนย์และช่วงที่ไม่รบกวนกัน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเครื่องอัดแรงเหวี่ยงและแกนหมุน\u003c\/li\u003e\n\u003cli\u003eพัดลมและเครื่องเป่าภาคอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eปั๊มกระบวนการ\u003c\/li\u003e\n\u003cli\u003eกังหันไอน้ำขนาดเล็กและเครื่องกำเนิดไฟฟ้ากังหัน\u003c\/li\u003e\n\u003cli\u003eพัดลมหอทำความเย็น\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสตัวเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบาย\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกช่วงเต็ม: 0.6-0-0.6 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ: 7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง: คลิปราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน: อนุมัติหลายรายการ (CSA NRTL\/C, ATEX Zone 0, ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eแบรนด์\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแหล่งกำเนิด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eลักษณะทางกายภาพ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักโดยประมาณ\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักประมาณ 0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eขนาด: ความยาวรวม\u003c\/td\u003e\n\u003ctd\u003e100.1 มม. (3.94 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eขนาด: ความกว้างรวม\u003c\/td\u003e\n\u003ctd\u003e73.9 มม. (2.91 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eขนาด: ความสูงตัวเครื่อง (ไม่มีคลิป DIN)\u003c\/td\u003e\n\u003ctd\u003e42.6 มม. (1.68 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eขนาด: ความสูงรวม (พร้อมคลิป BNC\/DIN)\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. (2.10 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง (ยาว)\u003c\/td\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง (ยาว) 69.9 มม. (2.75 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง (กว้าง)\u003c\/td\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง (กว้าง) 63.5 มม. (2.50 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง 5.8 มม. (0.23 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟฟ้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eช่วงแรงดันไฟฟ้าอินพุต\u003c\/td\u003e\n\u003ctd\u003e12 ถึง 35 Vdc (ที่ขั้วส่งสัญญาณ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตกระแส\u003c\/td\u003e\n\u003ctd\u003e4 ถึง 20 mA (เชิงเส้นในช่วง 1.2 มม.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความไวเอาต์พุต\u003c\/td\u003e\n\u003ctd\u003e12.8 mA\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตศูนย์ค่าปกติ\u003c\/td\u003e\n\u003ctd\u003e12 mA (อยู่กึ่งกลางในช่วงการเคลื่อนที่เชิงเส้น)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไดนามิก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการตอบสนองความถี่\u003c\/td\u003e\n\u003ctd\u003eDC ถึง 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตตัวเชื่อมต่อ BNC\u003c\/td\u003e\n\u003ctd\u003eแรงดันโพรบใกล้เคียงดิบแบบบัฟเฟอร์ (ค่าปกติ 7.87 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eสิ่งแวดล้อม\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-40 ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eควบแน่น 100% ไม่จมน้ำ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขั้วต่อ \/ ตัวเชื่อมต่อ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วต่ออินพุตโพรบใกล้เคียง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณร่วม \/ กราวด์ระบบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+4-20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วไฟฟ้ากระแสลูปบวก \/ ขั้วเอาต์พุตกระแส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4-20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วไฟฟ้ากระแสลูปลบ \/ ขั้วเอาต์พุตกระแส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเอาต์พุตแบบไดนามิก (แรงดันโพรบใกล้เคียงแบบบัฟเฟอร์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003ch3\u003eขนาดและการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eโมดูลรองรับการติดตั้งทั้งแบบติดแผง (bulkhead) และราง DIN สำหรับการติดตั้งแบบแผง ให้เตรียมรูยึดสี่รูโดยมีระยะห่าง 69.9 มม. คูณ 63.5 มม. ใช้รูยึดมาตรฐานขนาดเส้นผ่านศูนย์กลาง 5.8 มม. หรือสกรู 6-32 x 1.326 ที่ให้มาเพื่อยึดแผงอย่างมั่นคง สำหรับการติดตั้งแบบราง DIN ให้แน่ใจว่ามีการติดตั้งราง DIN ขนาดมาตรฐาน 35 มม. อย่างแข็งแรงก่อนคลิปยึดเครื่องส่งสัญญาณจะถูกยึดเข้ากับราง\u003c\/p\u003e\n\u003ch3\u003eการต่อสายดินและชีลด์\u003c\/h3\u003e\n\u003cp\u003eการต่อสายดินที่ถูกต้องเป็นสิ่งจำเป็นเพื่อลดสัญญาณรบกวน เครื่องส่งสัญญาณต้องติดตั้งบนแผ่นหรือราง DIN ที่ต่อสายดิน และต้องต่อสายชีลด์ของสายเคเบิลที่ปลายเดียวเท่านั้น โดยปกติที่ฝั่งห้องควบคุม\/DCS เพื่อป้องกันวงจรกราวด์ลูป\u003c\/p\u003e\n\u003ch3\u003eการปรับช่องว่างโพรบ\u003c\/h3\u003e\n\u003cp\u003eก่อนการใช้งานขั้นสุดท้าย ต้องปรับตำแหน่งโพรบใกล้ (ช่องว่าง) เทียบกับเป้าหมายเพลา ปรับช่องว่างจนกระทั่งเอาต์พุตของเครื่องส่งสัญญาณอ่านค่าได้ประมาณ 12 mA ซึ่งตรงกับจุดกึ่งกลางของช่วงแรงดันเชิงเส้น\u003c\/p\u003e\n\u003ch3\u003eการเดินสาย\u003c\/h3\u003e\n\u003cp\u003eเดินสายโพรบและสายวงจรในท่อโลหะหรือถาดสายไฟที่มีการต่อสายดินเฉพาะ หลีกเลี่ยงการเดินสายเครื่องส่งสัญญาณขนานกับสายไฟแรงดันสูงหรือวงจรสวิตช์เครื่องจักรหนักเพื่อป้องกันการรบกวนแม่เหล็กไฟฟ้า (EMI)\u003c\/p\u003e\n\u003ch3\u003eข้อควรระวังในพื้นที่อันตราย\u003c\/h3\u003e\n\u003cp\u003eเมื่อทำการติดตั้งในพื้นที่ที่มีการจัดประเภท ต้องใช้แผงกั้นความปลอดภัยภายในหรือกล่องกันระเบิดที่เหมาะสมตามรหัสไฟฟ้าท้องถิ่นและแบบติดตั้งเฉพาะที่ผู้ผลิตให้มา\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของเครื่องส่งสัญญาณแรงดันนี้คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eวัดการเคลื่อนที่ตามแกนหรือตำแหน่งแรงดันของเพลาหมุนของเครื่องจักรเทียบกับจุดอ้างอิงที่แน่นอนโดยใช้โพรบใกล้แบบไม่สัมผัส\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระบบโพรบประเภทใดที่เข้ากันได้กับเครื่องส่งสัญญาณนี้?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eออกแบบมาเฉพาะสำหรับเชื่อมต่อกับโพรบใกล้ Bently Nevada 3300 NSv และระบบสายต่อขยาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้ใช้พลังงานอย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเป็นอุปกรณ์ที่ใช้พลังงานจากวงจรกระแสไฟ 4 ถึง 20 mA โดยทำงานกับแหล่งจ่ายไฟ 12 ถึง 35 Vdc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eขั้วต่อ BNC ให้สัญญาณอะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eขั้วต่อ BNC ให้สัญญาณแรงดันดิบที่ผ่านการบัฟเฟอร์ซึ่งสัมพันธ์กับระยะช่องว่างของโพรบ ช่วยให้นักวิศวกรสามารถเชื่อมต่ออุปกรณ์วินิจฉัยเช่นออสซิลโลสโคปหรือเครื่องวิเคราะห์โดยไม่ต้องถอดวงจร\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้สามารถใช้วัดการสั่นสะเทือนรัศมีได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ รุ่นนี้ถูกตั้งค่าและปรับเทียบสำหรับการวัดตำแหน่งแรงดัน (แกนตามแนว) เท่านั้น สำหรับการสั่นสะเทือนรัศมี ควรใช้เครื่องส่งสัญญาณสั่นสะเทือน 990\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระยะห่างของรูยึดที่แน่นอนสำหรับการติดตั้งบนแผงควบคุมคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eระยะห่างของรูยึดสี่รูที่ต้องการคือ 69.9 มม. (2.75 นิ้ว) ในแนวยาว และ 63.5 มม. (2.50 นิ้ว) ในแนวกว้าง โดยใช้รูที่มีเส้นผ่านศูนย์กลาง 5.8 มม.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666532331883,"sku":"991-06-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-70-01-05-thrust-transmitter-qhotjgv0b0p_f70d5973-876a-48ff-ba1a-79a255c6a650.jpg?v=1765440374"},{"product_id":"bently-nevada-991-25-50-02-05-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-25-50-02-05 991 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณแรงดัน 991\u003c\/strong\u003e แปลงสัญญาณการเคลื่อนที่แกนเพลาในแนวแกนเป็นเอาต์พุต 4 ถึง 20 mA แบบสัดส่วนสำหรับระบบควบคุมและป้องกันเครื่องจักร อุปกรณ์นี้ออกแบบมาสำหรับเครื่องอัดอากาศแบบแรงเหวี่ยง ปั๊ม มอเตอร์ และพัดลมที่ต้องการการตรวจสอบตำแหน่งแรงดันอย่างต่อเนื่องผ่านอินเทอร์เฟซวงจรง่ายๆ ที่ใช้พลังงานจากวงจรเดียวกัน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-25-50-02-05\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณแบบ 2 สาย ใช้พลังงานจากวงจรที่เข้ากันได้กับระบบโพรบใกล้ 3300 NSv โดยใช้สายต่อยาว 5 เมตร เครื่องส่งสัญญาณนี้แปลงสัญญาณโพรบเป็นหน่วยวิศวกรรมที่สัดส่วนกับตำแหน่งแกนเพลาและส่งสัญญาณโดยตรงไปยัง PLC, DCS หรือระบบป้องกันเครื่องจักร\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณรวมเซ็นเซอร์ Proximitor ภายในและไม่ต้องการโมดูลปรับสัญญาณภายนอก การเข้าถึงการวินิจฉัยสามารถทำได้ผ่านขั้ว PROX OUT และ COM ที่ไม่แยกวงจร พร้อมกับขั้วต่อโคแอกเชียลสำหรับการตรวจสอบแรงสั่นสะเทือนและแรงดันช่องว่าง\u003c\/p\u003e\n\u003cp\u003eอุปกรณ์รองรับการติดตั้งแบบบัลค์เฮดและมีการปรับศูนย์และช่วงแบบไม่รบกวนกันสำหรับการสอบเทียบวงจร ขาอินพุตทดสอบเฉพาะช่วยให้สามารถตรวจสอบเอาต์พุตวงจรโดยใช้แหล่งจ่ายไฟ DC แบบปรับค่าได้\u003c\/p\u003e\n\u003cp\u003eการออกแบบตัวเรือนแบบพอตรองรับการติดตั้งในสภาพแวดล้อมอุตสาหกรรมที่มีความชื้นสูง เครื่องส่งสัญญาณนี้มักใช้ในชุดเครื่องจักรหมุน OEM ที่ต้องการการตรวจสอบแรงดันแบบกะทัดรัด\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเครื่องส่งสัญญาณแบบ 2 สาย ใช้พลังงานจากวงจร\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตแรงดันแรงดัน 4 ถึง 20 mA แบบสัดส่วน\u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับโพรบใกล้ 3300 NSv\u003c\/li\u003e\n\u003cli\u003eการออกแบบเซ็นเซอร์ Proximitor แบบบูรณาการ\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตแรงสั่นสะเทือนแบบไดนามิกและแรงดันช่องว่าง\u003c\/li\u003e\n\u003cli\u003eการติดตั้งแบบบัลค์เฮด\u003c\/li\u003e\n\u003cli\u003eการปรับศูนย์และช่วงแบบไม่รบกวนกัน\u003c\/li\u003e\n\u003cli\u003eวงจรป้องกันการเปิดเครื่อง\u003c\/li\u003e\n\u003cli\u003eการป้องกันสัญญาณ NOT OK\u003c\/li\u003e\n\u003cli\u003eรองรับการเข้าถึงสัญญาณวินิจฉัย\u003c\/li\u003e\n\u003cli\u003eโครงสร้างแบบพอตสำหรับสภาพแวดล้อมที่มีความชื้นสูง\u003c\/li\u003e\n\u003cli\u003eเหมาะสำหรับเครื่องอัดอากาศ ปั๊ม มอเตอร์ และพัดลม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเครื่องอัดอากาศแบบแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eปั๊มอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eมอเตอร์ไฟฟ้า\u003c\/li\u003e\n\u003cli\u003eชุดเครื่องจักรหมุน\u003c\/li\u003e\n\u003cli\u003eระบบสกิด OEM\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบแรงดันของเครื่องจักรเทอร์โบ\u003c\/li\u003e\n\u003cli\u003eระบบป้องกันเครื่องจักร\u003c\/li\u003e\n\u003cli\u003eอินเทอร์เฟซการตรวจสอบ PLC และ DCS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรหัส\u003c\/th\u003e\n\u003cth\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003ctd\u003eตัวส่งสัญญาณแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eช่วงเต็มสเกล +\/-25 มิล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eความยาวระบบ 5.0 ม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eสกรูยึดแบบบัลค์เฮด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eหมวดหมู่\u003c\/th\u003e\n\u003cth\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eตัวส่งสัญญาณแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003e991-25-50-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eซีรีส์\u003c\/td\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเทศผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทอินพุต\u003c\/td\u003e\n\u003ctd\u003eสายโพรบและสายต่อขยาย proximity 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุตสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตสัญญาณ 4 ถึง 20 mAdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ 12 ถึง 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำวงจร\u003c\/td\u003e\n\u003ctd\u003eความแม่นยำวงจร +\/-1.5% เต็มสเกล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานวงจรสูงสุด\u003c\/td\u003e\n\u003ctd\u003eความต้านทานวงจรสูงสุด 1000 โอห์ม ที่ 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการตอบสนองความถี่\u003c\/td\u003e\n\u003ctd\u003eตอบสนองความถี่ DC ถึง 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการจำกัดกระแส\u003c\/td\u003e\n\u003ctd\u003eจำกัดกระแส 23 mA โดยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเวลาตอบสนอง\u003c\/td\u003e\n\u003ctd\u003eเวลาตอบสนองความผิดพลาด \u0026lt;100 ไมโครวินาที\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-51 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 100% คอนเดนเสท ไม่จมน้ำ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักตัวส่งสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักตัวส่งสัญญาณ 0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักโดยทั่วไป 0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด\u003c\/td\u003e\n\u003ctd\u003eขนาด 100 x 74 x 53.3 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวิธีการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eสกรูยึดแบบบัลค์เฮด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสายโพรบ\u003c\/td\u003e\n\u003ctd\u003eสายโคแอกเชียล FEP ฉนวน 75 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุตัวเรือนแปลงสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eสแตนเลส AISI 303 หรือ 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุหัวแปลงสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eโพลีฟีนิลีนซัลไฟด์ (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eขาเชื่อมต่อ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1-E2\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟและเอาต์พุต 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE3-E4\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อ Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ2\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อวินิจฉัย PROX OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ3\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อโพรบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตสัญญาณการสั่นสะเทือนแบบไดนามิก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eขั้ววินิจฉัยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eติดตั้งตัวส่งสัญญาณในตู้ควบคุมที่แห้งหรือบริเวณแผงเครื่องจักรที่ได้รับการป้องกัน รักษาการป้องกันและการต่อสายดินที่เหมาะสมสำหรับสายโพรบและสายสัญญาณทั้งหมดเพื่อลดการรบกวน EMI และ RFI\u003c\/p\u003e\n\u003cp\u003eเดินสายโพรบโพรซิมิตี้แยกจากสายไฟแรงดันสูง หลีกเลี่ยงการดัดงอหรือความเครียดทางกลเกินไปบนสายโคแอกเชียลในระหว่างการติดตั้ง\u003c\/p\u003e\n\u003cp\u003eตรวจสอบการปรับช่องว่างของโพรบตามข้อกำหนดตำแหน่งเพลาของเครื่องจักรก่อนเริ่มใช้งาน การวางโพรบผิดตำแหน่งอาจทำให้การวัดเต็มสเกลไม่ทำงาน\u003c\/p\u003e\n\u003cp\u003eใช้เครื่องมือวินิจฉัยแบบแยกเมื่อเข้าถึงสัญญาณ PROX OUT เอาต์พุตวินิจฉัยไม่ได้แยกจากวงจร 4 ถึง 20 mA\u003c\/p\u003e\n\u003cp\u003eจัดให้มีการระบายอากาศเพียงพอรอบตัวส่งสัญญาณเมื่อทำการติดตั้งในตู้ปิดที่มีอุณหภูมิแวดล้อมสูง\u003c\/p\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eมาตรฐาน\u003c\/th\u003e\n\u003cth\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCC Part 15\u003c\/td\u003e\n\u003ctd\u003eการปฏิบัติตาม EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003ctd\u003eความต้านทานต่อ EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61000-6-4\u003c\/td\u003e\n\u003ctd\u003eการปล่อยสัญญาณ EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eคำสั่ง EMC 2014\/30\/EU\u003c\/td\u003e\n\u003ctd\u003eการปฏิบัติตาม EMC ของยุโรป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eคำสั่ง ATEX 2014\/34\/EU\u003c\/td\u003e\n\u003ctd\u003eการรับรองพื้นที่อันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eคำสั่ง RoHS 2011\/65\/EU\u003c\/td\u003e\n\u003ctd\u003eการปฏิบัติตาม RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eกฎเหล็กกล้าเรือ ABS 2009\u003c\/td\u003e\n\u003ctd\u003eการรับรองทางทะเล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA\/NRTL\/C Class I Div 2\u003c\/td\u003e\n\u003ctd\u003eการรับรองพื้นที่อันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\/IECEx Ex ia IIC T4 Ga\u003c\/td\u003e\n\u003ctd\u003eการรับรองความปลอดภัยโดยเนื้อแท้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณ 991 วัดอะไร?\u003c\/strong\u003e\u003cbr\u003eมันวัดการเคลื่อนที่ตามแกนของเพลาและแปลงสัญญาณเป็นเอาต์พุต 4 ถึง 20 mA ที่สัดส่วนกัน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระบบโพรบใดที่เข้ากันได้กับเครื่องส่งสัญญาณนี้?\u003c\/strong\u003e\u003cbr\u003eหน่วยนี้ออกแบบมาเพื่อใช้กับระบบโพรบใกล้ 3300 NSv\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณใช้พลังงานจากวงจรหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันทำงานเป็นอุปกรณ์ที่ใช้พลังงานจากวงจร 2 สาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสามารถให้การวินิจฉัยการสั่นสะเทือนได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การเชื่อมต่อ PROX OUT ให้สัญญาณการสั่นสะเทือนแบบไดนามิกและแรงดันช่องว่าง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรุ่นนี้ใช้วิธีการติดตั้งแบบใด?\u003c\/strong\u003e\u003cbr\u003eรุ่นนี้ใช้สกรูยึดแบบบัลค์เฮด\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณต้องการโมดูล Proximitor ภายนอกหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ เซ็นเซอร์ Proximitor รวมอยู่ในเครื่องส่งสัญญาณแล้ว\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eประเภทสัญญาณเอาต์พุตคืออะไร?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตมาตรฐานคือ 4 ถึง 20 mAdc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสามารถเชื่อมต่อโดยตรงกับ PLC หรือ DCS ได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ เอาต์พุตเหมาะสำหรับอินพุตอนาล็อกของระบบควบคุมอุตสาหกรรมมาตรฐาน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eช่วงอุณหภูมิการทำงานที่รองรับคืออะไร?\u003c\/strong\u003e\u003cbr\u003eช่วงอุณหภูมิการทำงานอยู่ที่ -35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตัวเรือนเหมาะสำหรับสภาพแวดล้อมที่มีความชื้นหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ โครงสร้างแบบพอตเทดรองรับสภาพแวดล้อมที่มีความชื้นสูง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเกิดอะไรขึ้นในกรณีที่เซ็นเซอร์ตรวจจับมีข้อผิดพลาด?\u003c\/strong\u003e\u003cbr\u003eวงจร NOT OK จะขับเคลื่อนเอาต์พุตต่ำกว่า 3.6 mA เมื่อเกิดข้อผิดพลาด\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถทดสอบเอาต์พุตวงจรโดยไม่ต้องเคลื่อนย้ายเครื่องจักรได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ ขาอินพุตทดสอบรองรับการตรวจสอบวงจรโดยใช้แหล่งจ่ายไฟ DC แบบปรับได้\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณรองรับการติดตั้งในพื้นที่อันตรายหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ หน่วยนี้ได้รับการรับรอง CSA และ ATEX\/IECEx ขึ้นอยู่กับการกำหนดค่า\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุตสาหกรรมใดบ้างที่ใช้เครื่องส่งสัญญาณนี้บ่อยครั้ง?\u003c\/strong\u003e\u003cbr\u003eใช้กันอย่างแพร่หลายในระบบตรวจสอบคอมเพรสเซอร์ ปั๊ม มอเตอร์ และอุปกรณ์หมุน\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666539508075,"sku":"991-25-50-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-50-02-05-sensor-proximity-0t0frsy3a1c_f409c99a-d085-41f0-8c60-aad1f927cbb1.jpg?v=1765440452"},{"product_id":"bently-nevada-990-10-70-01-00-vibration-transmitter","title":"เครื่องส่งสัญญาณการสั่นสะเทือน Bently Nevada 990-10-70-01-00","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 990-10-70-01-00\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณการสั่นสะเทือนแบบสองสาย ใช้พลังงานจากวงจรลูป ออกแบบมาสำหรับผู้ผลิตอุปกรณ์ต้นแบบ (OEM) ของเครื่องอัดอากาศแบบแรงเหวี่ยง ปั๊มขนาดเล็ก มอเตอร์ หรือพัดลม หน่วยอุตสาหกรรมนี้ปรับสัญญาณไดนามิกจากโพรบใกล้ 3300 NSv และสายต่อขยายที่เข้ากัน แปลงการเคลื่อนที่ดิบเป็นสัญญาณลูปมาตรฐานอุตสาหกรรม 4 ถึง 20 mA ช่วงการสั่นสะเทือนเต็มสเกล 0 ถึง 10 มิลส์ พีคทูพีค ($0-250 \\mu\\text{m}$ pp) ตั้งค่าสำหรับการจัดวางระบบความยาว 7.0 เมตร ติดตั้งเซ็นเซอร์ Proximitor ในตัว ปรับศูนย์และสแปนที่ไม่รบกวนกัน และวงจรความปลอดภัย Not OK\/Signal Defeat เฉพาะทาง ส่งผลให้สามารถติดตามการสั่นสะเทือนอย่างต่อเนื่องไปยังระบบควบคุมเครื่องจักรและ PLC ได้โดยตรง\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eติดตั้งเซ็นเซอร์ Proximitor ในตัวที่ไม่ต้องการหน่วยปรับสภาพภายนอก\u003c\/li\u003e\n\u003cli\u003eมีขั้วต่อโคแอกเชียล PROX OUT แบบไม่แยกส่วนที่ให้เอาต์พุตแรงสั่นสะเทือนไดนามิกและแรงดันช่องว่างโดยตรงสำหรับการวินิจฉัยเครื่องจักร\u003c\/li\u003e\n\u003cli\u003eมีโพเทนชิโอมิเตอร์ศูนย์และสแปนในตัวที่ไม่รบกวนกันสำหรับการปรับเทียบวงจรภาคสนามอย่างแม่นยำ\u003c\/li\u003e\n\u003cli\u003eขาอินพุตทดสอบในตัวช่วยให้การตรวจสอบวงจรอย่างรวดเร็วโดยใช้เครื่องกำเนิดฟังก์ชันภายนอก\u003c\/li\u003e\n\u003cli\u003eออกแบบด้วยวงจร Not OK\/Signal Defeat เพื่อป้องกันสัญญาณเตือนเครื่องจักรเท็จจากการเชื่อมต่อหลวมหรือฮาร์ดแวร์ที่ชำรุด\u003c\/li\u003e\n\u003cli\u003eมีวิธีการก่อสร้างแบบพอตต์ที่ให้ความต้านทานในสภาพแวดล้อมการทำงานที่มีความชื้นสูง (ถึง 100% การควบแน่น)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการติดตามการสั่นสะเทือนพีคทูพีคอย่างต่อเนื่องบนเครื่องอัดอากาศแบบแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eวงจรติดตามการสั่นสะเทือนโดยรวมในพื้นที่สำหรับปั๊มอุตสาหกรรมขนาดเล็ก มอเตอร์ หรือพัดลม\u003c\/li\u003e\n\u003cli\u003eการรวมเมตริกโพรบแบบไม่สัมผัสแบบไดนามิกโดยตรงเข้าสู่โครงสร้างพื้นฐานการควบคุมที่ใช้ PLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการแยกข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cp\u003eรหัสรุ่น \u003cstrong\u003e990-10-70-01-00\u003c\/strong\u003e แสดงถึงการรวมค่าที่ตั้งไว้ล่วงหน้าของตัวเลือกการสั่งซื้อสี่รายการเฉพาะ:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eชิ้นส่วนตัวเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสที่เลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนดทางเทคนิค\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกเต็มสเกล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 10 มิลส์ พีคทูพีค (0 ถึง 250 ไมโครเมตร พีคทูพีค)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกความยาวระบบ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003eความยาวระบบ 7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกการติดตั้ง  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eคลิปราง DIN ขนาด 35 มม. แบบบูรณาการ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกการอนุมัติหน่วยงาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eไม่ต้องการการอนุมัติ\/รับรอง  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสรุ่น  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-70-01-00 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวส่งสัญญาณการสั่นสะเทือน   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกเต็มสเกล (10)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10 มิล pp ($0-250 \\mu\\text{m}$ pp)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกความยาวระบบ (70)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความยาวระบบ 7.0 เมตร (23.0 ฟุต)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกการติดตั้ง (01)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eคลิปราง DIN ขนาด 35 มม.   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกการอนุมัติหน่วยงาน (00)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไม่จำเป็น   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eข้อกำหนดการจ่ายไฟ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอินพุต +12 ถึง +35 Vdc ที่เทอร์มินัลตัวส่งสัญญาณ   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสัญญาณเอาต์พุต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ถึง 20 mAdc ในช่วงเต็มสเกลที่กำหนด (2 สาย)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความแม่นยำของลูป  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eภายใน ±1.5% ในช่วงเต็มสเกลที่กำหนด   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานลูปสูงสุด  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 โอห์ม รวมสายเคเบิลที่ 35 Vdc   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการจำกัดกระแส  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 mA โดยทั่วไป   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทาน Prox Out  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความต้านทานเอาต์พุต 10 kOhm ปรับเทียบสำหรับโหลด 10 MOhm   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงเชิงเส้นของ Prox Out  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 มม. (55 มิล)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eปัจจัยสเกลเพิ่มขึ้น  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/$\\mu\\text{m}$ (200 mV\/mil) ±6.5% โดยทั่วไป   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการตอบสนองความถี่  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz ถึง 6,000 Hz +0, -3 dB   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน (ตัวส่งสัญญาณ)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-31 ถึง +185 องศาฟาเรนไฮต์)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา (ตัวส่งสัญญาณ)  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 องศาเซลเซียส ถึง +100 องศาเซลเซียส (-62 ถึง +212 องศาฟาเรนไฮต์)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขีดจำกัดความชื้นสัมพัทธ์  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eควบแน่น 100% ไม่จมน้ำ   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักสุทธิของตัวส่งสัญญาณ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 กก. (0.9 ปอนด์)   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eติดตั้งตัวเครื่องส่งสัญญาณอย่างมั่นคงบนโครงสร้างอุตสาหกรรมมาตรฐานโดยใช้คลิปราง DIN ขนาด 35 มม. ที่ติดตั้งมาแล้ว  \u003c\/li\u003e\n\u003cli\u003eต่อสายจ่ายไฟภายนอกเข้ากับบล็อกเทอร์มินัล E1 และ E2 โดยให้แรงดันลูปอินพุตอยู่ในช่วงการทำงานที่กำหนดไว้ที่ +12 ถึง +35 Vdc  \u003c\/li\u003e\n\u003cli\u003eเดินสายเคเบิลต่อขยายยาว 7.0 เมตรจากโพรบ 3300 NSv เข้าพอร์ตโคแอกเชียลแบบบูรณาการโดยตรง หลีกเลี่ยงการขันเกลียวเกินขีดจำกัดเพื่อลดความเสี่ยงของการติดขัดที่ขั้วต่อ  \u003c\/li\u003e\n\u003cli\u003eแยกเส้นทางลูปการสื่อสารที่เชื่อมต่อทั้งหมดออกจากสายไฟแรงดันสูงของมอเตอร์หลักที่อยู่ใกล้เคียง เพื่อลดการรบกวนจากสัญญาณแม่เหล็กไฟฟ้า  \u003c\/li\u003e\n\u003cli\u003eสำหรับการวินิจฉัยความปลอดภัยโดยใช้เครื่องมือทดสอบที่มีกราวด์และใช้ไฟฟ้ากระแสสลับ ให้เชื่อมต่อผ่านอะแดปเตอร์ทดสอบ 122115-01 เพื่อรักษาการแยกวงจรและปกป้องความสมบูรณ์ของเส้นทางสัญญาณลูป  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666540294507,"sku":"990-10-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-70-01-00-vibration-transmitter-q1beombryzw_1670b565-7dd9-4a9d-8140-17eb4ae853a9.jpg?v=1765440460"},{"product_id":"bently-nevada-991-25-70-01-00-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-25-70-01-00 991 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-25-70-01-00\u003c\/strong\u003e เป็นตัวส่งสัญญาณแรงดันแบบสองสาย ใช้พลังงานจากลูป ถูกออกแบบมาสำหรับผู้ผลิตอุปกรณ์ต้นแบบ (OEM) ของเครื่องอัดอากาศแบบแรงเหวี่ยง ปั๊มขนาดเล็ก มอเตอร์ หรือพัดลม รับสัญญาณอินพุตจาก \u003cstrong\u003eโพรบระยะใกล้ 3300 NSv\u003c\/strong\u003e และสายต่อขยายที่เข้ากัน แปลงข้อมูลการเลื่อนตำแหน่งเป็นสัญญาณแรงดันแกนสัดส่วน 4 ถึง 20 mA ง่ายๆ การตั้งค่านี้ช่วยให้รวมเข้ากับระบบควบคุมเครื่องจักร PLC หรือ DCS ได้โดยตรงโดยไม่ต้องใช้หน่วยเซ็นเซอร์ Proximitor ภายนอก  \u003c\/p\u003e\n\u003cp\u003eอุปกรณ์มีขั้วต่อ \"PROX OUT\" และ \"COM\" ที่ไม่แยกวงจรพร้อมขั้วต่อโคแอกเชียล ให้สัญญาณแรงสั่นสะเทือนและแรงดันช่องว่างแบบไดนามิกสำหรับการวินิจฉัยและตรวจสอบการบำรุงรักษาเครื่องจักร  \u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eฟังก์ชันเซ็นเซอร์ Proximitor ในตัวช่วยลดความจำเป็นของหน่วยปรับสัญญาณแยกต่างหาก  \u003c\/li\u003e\n\u003cli\u003eเอาต์พุตลูปกระแส 4 ถึง 20 mA โดยตรงที่สอดคล้องกับอินพุตระบบควบคุมเครื่องจักรมาตรฐาน  \u003c\/li\u003e\n\u003cli\u003eเอาต์พุตสัญญาณวินิจฉัยแบบไดนามิกผ่านขั้วต่อโคแอกเชียลที่ไม่แยกวงจรเพื่อความสะดวกในการแก้ไขปัญหา  \u003c\/li\u003e\n\u003cli\u003eออกแบบให้เข้ากันได้กับระบบโพรบระยะใกล้ 3300 NSv  \u003c\/li\u003e\n\u003cli\u003eออกแบบแข็งแรงเหมาะสำหรับติดตั้งใกล้เครื่องจักรที่ตรวจสอบ  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการเลื่อนแกนของเครื่องอัดอากาศแบบแรงเหวี่ยง  \u003c\/li\u003e\n\u003cli\u003eระบบป้องกันเครื่องจักรปั๊มและพัดลมอุตสาหกรรม  \u003c\/li\u003e\n\u003cli\u003eการตรวจจับการสึกหรอของตลับลูกปืนแรงดันมอเตอร์ไฟฟ้าขนาดเล็ก  \u003c\/li\u003e\n\u003cli\u003eการตรวจสอบกลองสมดุลในเครื่องจักรของเหลวแรงดันสูง  \u003c\/li\u003e\n\u003cli\u003eการติดตามตำแหน่งลูกสูบสมดุลในอุปกรณ์หมุน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003ch3\u003e991-25-70-01-00\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e991\u003c\/strong\u003e: ตัวส่งสัญญาณแรงดัน  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25\u003c\/strong\u003e: ตัวเลือกช่วงเต็มสเกล: 25-0-25 มิล  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70\u003c\/strong\u003e: ตัวเลือกความยาวระบบ: 7.0 เมตร (23.0 ฟุต)  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: ตัวเลือกการติดตั้ง: คลิปติดตั้งราง DIN ขนาด 35 มม.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: ตัวเลือกการอนุมัติจากหน่วยงาน: ไม่จำเป็น \/ การอนุมัติแบบมาตรฐาน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eหมายเลขรุ่น  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e991-25-70-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวส่งสัญญาณแรงดัน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเทศต้นทาง  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา (USA)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงเต็มสเกล  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eช่วงเต็มสเกล 25-0-25 มิล  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความยาวระบบ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 เมตร (23.0 ฟุต)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเลือกการติดตั้ง  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eคลิปติดตั้งราง DIN ขนาด 35 มม.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการอนุมัติจากหน่วยงาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไม่ต้องการการอนุมัติพื้นที่อันตราย (ตัวเลือก -00)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงแรงดันไฟฟ้า  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ถึง 35 Vdc  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทเอาต์พุต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ถึง 20 mA DC สัดส่วนการเลื่อนแกน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงระยะใกล้  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ถึง 65 มิล  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความเสถียรของอุณหภูมิ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eปัจจัยสเกลภายในบวกหรือลบ 10% ของ 7.87 mV\/ไมโครเมตร (200 mV\/มิล) จาก 0 องศาเซลเซียส ถึง 70 องศาเซลเซียส  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงานของตัวส่งสัญญาณ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษาตัวส่งสัญญาณ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 องศาเซลเซียส ถึง +100 องศาเซลเซียส  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eระยะทางเอาต์พุตสัญญาณสูงสุด  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eระยะสูงสุด 13 กม. (8 ไมล์) ระหว่างตัวส่งสัญญาณและอุปกรณ์รับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eระยะเอาต์พุต Proximitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eระยะสายสูงสุด 3 เมตร (10 ฟุต) ผ่านตัวเชื่อมต่อ BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโดยประมาณ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักประมาณ 0.43 กก. (เฉพาะตัวเครื่อง) \/ น้ำหนักจัดส่งประมาณ 2.00 ปอนด์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดโดยประมาณ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขนาดประมาณ 100 มม. x 74 มม. x 53.3 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขา \/ ขั้วเชื่อมต่อ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX OUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณทรานสดิวเซอร์ไดนามิกแบบไม่แยกวงจรสำหรับการวินิจฉัย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดอ้างอิงร่วม \/ กราวด์กลับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณกระแสลูป 4 ถึง 20 mA เอาต์พุต\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วรับแรงดันไฟฟ้าลูปบวก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eตัวเชื่อมต่อโคแอกเชียล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดเชื่อมต่อโดยตรงสำหรับสายต่อขยายโพรบ 3300 NSv ที่เข้ากันได้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003ch3\u003eการติดตั้งราง DIN\u003c\/h3\u003e\n\u003cp\u003eติดตั้งตัวส่งสัญญาณโดยใช้คลิปติดตั้งราง DIN ขนาด 35 มม. ที่ติดตั้งไว้ล่วงหน้า ตรวจสอบให้แน่ใจว่ารางกราวด์อย่างถูกต้องและอยู่ในพื้นที่ที่มีการสัมผัสทางกายภาพกับเศษวัสดุตกหรือการรั่วไหลของของเหลวกระบวนการโดยตรงน้อยที่สุด\u003c\/p\u003e\n\u003ch3\u003eการป้องกันและการกราวด์\u003c\/h3\u003e\n\u003cp\u003eใช้สายคู่บิดเกลียวที่มีการป้องกันเสมอสำหรับการเชื่อมต่อวงจรลูป 4 ถึง 20 mA เชื่อมต่อสายป้องกันกับกราวด์เครื่องมือที่ระบบควบคุมหรือฝั่ง DCS เท่านั้น ห้ามกราวด์สายป้องกันทั้งสองด้านเพื่อหลีกเลี่ยงข้อผิดพลาดกระแสลูปกราวด์\u003c\/p\u003e\n\u003ch3\u003eการเดินสาย\u003c\/h3\u003e\n\u003cp\u003eเดินสายสัญญาณให้ห่างจากสายไฟแรงดันสูง AC สายจ่ายมอเตอร์ไฟฟ้า หรือรีเลย์สวิตชิ่ง เพื่อลดการรบกวนสัญญาณ EMI\/RFI บนสัญญาณวงจรลูปแรงดันต่ำ 4 ถึง 20 mA\u003c\/p\u003e\n\u003ch3\u003eการปรับช่องว่างโพรบ\u003c\/h3\u003e\n\u003cp\u003eตั้งค่าช่องว่างโพรบเริ่มต้นโดยใช้ขั้ว \"PROX OUT\" และ \"COM\" เพื่อตรวจสอบแรงดันช่องว่าง DC เริ่มต้น ตรวจสอบให้แน่ใจว่าระยะทางทางกายภาพระหว่างปลายโพรบกับวัสดุเป้าหมายทำให้เอาต์พุตอยู่ในช่วงการทำงานเชิงเส้นที่ปลอดภัยระหว่าง 10 ถึง 65 มิล\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของ Bently Nevada 991 คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eมันแปลงข้อมูลโพรบใกล้เคียงดิบเป็นสัญญาณวงจรลูปมาตรฐาน 4 ถึง 20 mA ที่แสดงการเลื่อนแกนเพลาหรือแรงดัน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโพรบใกล้เคียงตระกูลใดที่เข้ากันได้กับรุ่นนี้?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรุ่นนี้ออกแบบมาเฉพาะเพื่อเชื่อมต่อกับชุดโพรบใกล้เคียง Bently Nevada 3300 NSv และสายต่อขยายที่เข้ากันได้\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้แหล่งจ่ายไฟประเภทใดเพื่อขับเคลื่อนวงจรลูปของตัวส่งสัญญาณ?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตัวส่งสัญญาณทำงานด้วยแหล่งจ่ายไฟวงจรลูปมาตรฐานที่มีช่วงระหว่าง 12 Vdc ถึง 35 Vdc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฉันสามารถอ่านสัญญาณไดนามิกดิบขณะตัวส่งสัญญาณทำงานได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ ตัวส่งสัญญาณมีตัวเชื่อมต่อ BNC coaxial แบบไม่แยกวงจรและขั้ว PROX OUT เพื่อจับสัญญาณช่องว่างไดนามิกและการสั่นสะเทือนสำหรับการวิเคราะห์วินิจฉัย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตัวเลือกการติดตั้งใดที่รุ่น 991-25-70-01-00 มี?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการกำหนดค่านี้รวมฮาร์ดแวร์ติดตั้งแบบ 01-option ที่รวมอยู่ในตัว เหมาะสำหรับราง DIN ขนาดมาตรฐาน 35 มม.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541605227,"sku":"991-25-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-70-01-00-991-thrust-transmitter-czcnkkkmhcj_abbb7e1f-2cf6-410b-91de-238f48d0cb95.jpg?v=1765440474"},{"product_id":"bently-nevada-990-05-70-01-00-990-2-wire-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-05-70-01-00 เครื่องส่งสัญญาณการสั่นสะเทือน 2 สาย รุ่น 990","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 990-05-70-01-00\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณสั่นสะเทือนขนาดกะทัดรัดที่ออกแบบมาเพื่อตรวจสอบเครื่องจักรหมุนในระบบกระบวนการอุตสาหกรรมอย่างต่อเนื่อง โดยแปลงสัญญาณการสั่นสะเทือนเพลาจากโพรบใกล้ 3300 NSv ที่เข้ากันได้เป็นสัญญาณเอาต์พุตมาตรฐาน 4 ถึง 20 mA ที่เหมาะสำหรับการเชื่อมต่อโดยตรงกับ PLC, DCS และแพลตฟอร์มป้องกันเครื่องจักร\u003c\/p\u003e\n\u003cp\u003eการกำหนดค่านี้ใช้ระบบทรานสดิวเซอร์ยาว 7.0 เมตรและรองรับการติดตั้งที่ต้องเดินสายโพรบยาวระหว่างตัวเครื่องและตู้ควบคุม อิเล็กทรอนิกส์ปรับสัญญาณแบบบูรณาการช่วยให้งานติดตั้งภาคสนามง่ายขึ้นโดยไม่ต้องใช้ชุด Proximitor ภายนอกแยกต่างหาก\u003c\/p\u003e\n\u003cp\u003eตัวเรือนเครื่องส่งสัญญาณถูกห่อหุ้มเต็มที่เพื่อเพิ่มความน่าเชื่อถือในสภาพแวดล้อมที่ชื้นซึ่งพบได้ทั่วไปรอบเครื่องอัด, ปั๊ม และอุปกรณ์กระบวนการเสริม มีการเชื่อมต่อ PROX OUT เฉพาะสำหรับการวิเคราะห์สั่นสะเทือนชั่วคราวและการวัดวินิจฉัยในระหว่างกิจกรรมบำรุงรักษา\u003c\/p\u003e\n\u003cp\u003eการปรับเทียบจากโรงงานสามารถเข้าถึงได้ใต้ป้ายเครื่องส่งสัญญาณ ช่วยให้ช่างเทคนิคภาคสนามปรับแต่งเอาต์พุตลูปได้โดยไม่ต้องถอดฝาครอบ\u003c\/p\u003e\n\u003ch3\u003eฟังก์ชันหลัก\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการสั่นสะเทือนเพลาต่อเนื่อง\u003c\/li\u003e\n\u003cli\u003eการส่งสัญญาณสัดส่วน 4 ถึง 20 mA\u003c\/li\u003e\n\u003cli\u003eอิเล็กทรอนิกส์เซ็นเซอร์ Proximitor แบบบูรณาการ\u003c\/li\u003e\n\u003cli\u003eการเข้าถึงสัญญาณไดนามิกผ่าน PROX OUT\u003c\/li\u003e\n\u003cli\u003eการทำงานแบบลูป 2 สายที่ใช้พลังงานลูป\u003c\/li\u003e\n\u003cli\u003eการตรวจจับข้อผิดพลาดโพรบและตรรกะป้องกันสัญญาณ\u003c\/li\u003e\n\u003cli\u003eการปรับเทียบศูนย์และสเกลภายนอก\u003c\/li\u003e\n\u003cli\u003eรองรับการติดตั้งบนราง DIN\u003c\/li\u003e\n\u003cli\u003eรูปแบบกะทัดรัดสำหรับแผง OEM\u003c\/li\u003e\n\u003cli\u003eโครงสร้างห่อหุ้มกันความชื้น\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการติดตั้งทั่วไป\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eประเภทอุปกรณ์\u003c\/th\u003e\n\u003cth\u003eวัตถุประสงค์การตรวจสอบ\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องอัดแรงเหวี่ยง\u003c\/td\u003e\n\u003ctd\u003eการสั่นสะเทือนเพลารัศมี\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eมอเตอร์อุตสาหกรรม\u003c\/td\u003e\n\u003ctd\u003eแนวโน้มการสั่นสะเทือนของแบริ่ง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปั๊มกระบวนการ\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบสภาพเครื่องจักรทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eพัดลมและเครื่องเป่า\u003c\/td\u003e\n\u003ctd\u003eการป้องกันชุดหมุน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องจักร OEM แบบสกิด\u003c\/td\u003e\n\u003ctd\u003eฟีดแบ็กสั่นสะเทือนแบบบูรณาการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระบบสาธารณูปโภค\u003c\/td\u003e\n\u003ctd\u003eโปรแกรมบำรุงรักษาเชิงคาดการณ์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eตัวเลือก\u003c\/th\u003e\n\u003cth\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003e990 - เครื่องส่งสัญญาณสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e05 - 0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e70 - 7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e01 - คลิปติดราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003e00 - ไม่จำเป็น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eรายละเอียดสินค้า\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรายการ\u003c\/th\u003e\n\u003cth\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n\u003ctd\u003e990-05-70-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณสั่นสะเทือน 2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสภาพสินค้า\u003c\/td\u003e\n\u003ctd\u003eใหม่และแท้ในบรรจุภัณฑ์โรงงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการรับประกันจากโรงงาน\u003c\/td\u003e\n\u003ctd\u003e12 เดือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุปกรณ์นำเข้า\u003c\/td\u003e\n\u003ctd\u003eโพรบใกล้ 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสัญญาณ\u003c\/td\u003e\n\u003ctd\u003e4 ถึง 20 mAdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eข้อกำหนดพลังงาน\u003c\/td\u003e\n\u003ctd\u003e+12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวิธีการเดินสาย\u003c\/td\u003e\n\u003ctd\u003eใช้พลังงานลูป 2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e+\/-1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการจำกัดกระแส\u003c\/td\u003e\n\u003ctd\u003e23 mA ปกติ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการตอบสนองความถี่\u003c\/td\u003e\n\u003ctd\u003e5 Hz ถึง 6000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eข้อกำหนดช่องว่างของโพรบ\u003c\/td\u003e\n\u003ctd\u003e0.5 ถึง 1.75 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานลูปสูงสุด\u003c\/td\u003e\n\u003ctd\u003e1000 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 100% ที่เกิดการควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-52 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงานของโพรบ\u003c\/td\u003e\n\u003ctd\u003e-52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุโพรบ\u003c\/td\u003e\n\u003ctd\u003eสแตนเลสสตีล AISI 303 หรือ 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eโครงสร้างสายเคเบิล\u003c\/td\u003e\n\u003ctd\u003eสายโคแอกเชียล FEP ฉนวน 75 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักสุทธิ\u003c\/td\u003e\n\u003ctd\u003e0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd\u003e0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eการเชื่อมต่อ\u003c\/th\u003e\n\u003cth\u003eวัตถุประสงค์\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตสั่นสะเทือนแบบไดนามิก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eสัญญาณร่วม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตทดสอบ\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบวงจรลูป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตไฟฟ้ากระแสตรง\u003c\/td\u003e\n\u003ctd\u003eแรงดันจ่ายเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุต 4-20 mA\u003c\/td\u003e\n\u003ctd\u003eสัญญาณควบคุมกระบวนการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eติดตั้งเครื่องส่งสัญญาณบนราง DIN ที่มีการต่อสายดินอย่างถูกต้องภายในตู้ควบคุมที่ได้รับการป้องกัน รักษาระยะห่างระหว่างสายทรานสดิวเซอร์กับสายไฟแรงสูงเพื่อลดสัญญาณรบกวนทางไฟฟ้า\u003c\/p\u003e\n\u003cp\u003eควรตรวจสอบช่องว่างระหว่างโพรบกับเป้าหมายก่อนเริ่มใช้งานเพื่อให้แน่ใจว่าการตอบสนองเชิงเส้นถูกต้อง เมื่อใช้เครื่องวิเคราะห์แบบพกพาหรือออสซิลโลสโคปสำหรับการวินิจฉัย แนะนำให้ใช้เครื่องมือทดสอบแยกสำหรับการเชื่อมต่อ PROX OUT\u003c\/p\u003e\n\u003cp\u003eตัวเรือนที่หุ้มช่วยรองรับการทำงานในสภาพความชื้นสูง แต่ขั้วต่อที่เปิดควรได้รับการป้องกันจากความชื้นขังและการล้างโดยตรง\u003c\/p\u003e\n\u003cp\u003eหลีกเลี่ยงการขันเกลียวมากเกินไปในระหว่างการติดตั้งโพรบ การขันแน่นเกินไปอาจทำให้เกิดการติดขัดทางกลภายในตำแหน่งติดตั้งที่มีเกลียว\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณวัดอะไร?\u003c\/strong\u003e\u003cbr\u003eมันวัดการสั่นสะเทือนของเพลาจากระบบโพรบใกล้เคียงที่เข้ากันได้และแปลงสัญญาณเป็นเอาต์พุต 4 ถึง 20 mA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้ระบบโพรบใด?\u003c\/strong\u003e\u003cbr\u003eเครื่องส่งสัญญาณออกแบบมาสำหรับชุดโพรบ Bently Nevada 3300 NSv\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรุ่นนี้มีการอนุมัติสำหรับพื้นที่อันตรายหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ ตัวเลือกการอนุมัติ -00 หมายถึงการกำหนดค่ามาตรฐานที่ไม่เป็นอันตราย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์ติดตั้งใดบ้างที่รวมมาให้?\u003c\/strong\u003e\u003cbr\u003eรุ่นนี้มาพร้อมคลิปติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้สามารถเชื่อมต่อโดยตรงกับ PLC ได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ เอาต์พุตแบบอะนาล็อกมีไว้สำหรับช่องอินพุตอะนาล็อกของ PLC และ DCS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณใช้พลังงานจากวงจรลูปหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันทำงานจากวงจรที่ใช้พลังงานแบบสองสาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับความยาวระบบสายเคเบิลเท่าใด?\u003c\/strong\u003e\u003cbr\u003eรุ่นนี้ใช้ระบบทรานสดิวเซอร์ยาว 7.0 เมตร\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eช่างเทคนิคสามารถเข้าถึงสัญญาณสั่นสะเทือนดิบได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การเชื่อมต่อ PROX OUT ให้การเข้าถึงสัญญาณไดนามิกสำหรับการวินิจฉัย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นเมื่อโพรบล้มเหลว?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตจะลดลงต่ำกว่า 3.6 mA เพื่อแสดงสถานะ NOT OK\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับการสอบเทียบภาคสนามหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การปรับศูนย์และสแปนสามารถเข้าถึงได้จากภายนอก\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตัวเรือนออกแบบมาสำหรับสภาพแวดล้อมแบบใด?\u003c\/strong\u003e\u003cbr\u003eโครงสร้างแบบพอตช่วยรองรับสภาพแวดล้อมอุตสาหกรรมที่มีความชื้นสูง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสามารถวิเคราะห์เฟสการสั่นสะเทือนได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ใช่ เอาต์พุต 4 ถึง 20 mA มีไว้สำหรับการติดตามการสั่นสะเทือนโดยรวมเท่านั้น\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666547536235,"sku":"990-05-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-01-00-990-vibration-transmitter-ag0r2xbfqwa_90db2fd6-9baa-4c27-9b59-19c2d833a0b2.jpg?v=1765440533"},{"product_id":"bently-nevada-990-05-50-01-00-990-2-wire-vibration-transmitter","title":"Bently Nevada 990-05-50-01-00 | เครื่องส่งสัญญาณการสั่นสะเทือน 990 แบบ 2 สาย","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการรวมโดยตรงเข้ากับระบบควบคุมอุปกรณ์หมุน เครื่องส่งสัญญาณการสั่นสะเทือน 2 สาย \u003cstrong\u003e990\u003c\/strong\u003e แปลงการวัดการสั่นสะเทือนเพลาลงเป็นสัญญาณเอาต์พุตมาตรฐาน 4 ถึง 20 mA สำหรับ PLC, DCS และการใช้งานป้องกันเครื่องจักร เครื่องส่งสัญญาณทำงานร่วมกับโพรบ proximity 3300 NSv และชุดสายต่อขยายเพื่อตรวจสอบระดับการสั่นสะเทือนสูงสุดถึงสูงสุดบนคอมเพรสเซอร์ มอเตอร์ ปั๊ม และพัดลมอุตสาหกรรม\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณ \u003cstrong\u003eBently Nevada\u003c\/strong\u003e รวมวงจรอิเล็กทรอนิกส์ปรับสัญญาณและเซ็นเซอร์ Proximitor ไว้ในตัวเรือนกะทัดรัดเดียว ลดความต้องการฮาร์ดแวร์ภายนอกและทำให้ง่ายต่อการติดตั้งภายในชุดอุปกรณ์ OEM โครงสร้างแบบพอตช่วยให้ทำงานได้ในสภาพแวดล้อมที่มีความชื้นสูง ขณะที่การเชื่อมต่อ PROX OUT แบบบูรณาการช่วยให้เข้าถึงสัญญาณการสั่นสะเทือนแบบไดนามิกสำหรับการแก้ไขปัญหาและวินิจฉัยเครื่องจักร\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณ \u003cstrong\u003e990-05-50-01-00\u003c\/strong\u003e การกำหนดค่ารวมความยาวระบบ 5.0 เมตร คลิปติดราง DIN ขนาด 35 มม. และการอนุมัติการกำหนดค่าในพื้นที่ที่ไม่เป็นอันตรายมาตรฐาน\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการออกแบบเครื่องส่งสัญญาณแบบวงจรสองสายที่ใช้พลังงานวงจร\u003c\/li\u003e\n\u003cli\u003eชุดเซ็นเซอร์ Proximitor แบบบูรณาการ\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตการสั่นสะเทือน 4 ถึง 20 mA\u003c\/li\u003e\n\u003cli\u003eรองรับระบบโพรบ 3300 NSv\u003c\/li\u003e\n\u003cli\u003eการปรับเทียบศูนย์และสเกลภายนอก\u003c\/li\u003e\n\u003cli\u003eการเชื่อมต่อสัญญาณวินิจฉัย PROX OUT\u003c\/li\u003e\n\u003cli\u003eการป้องกันสัญญาณขัดจังหวะในกรณีโพรบผิดพลาด\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตตอบสนองเร็ว NOT OK\u003c\/li\u003e\n\u003cli\u003eการกำหนดค่าการติดตั้งราง DIN\u003c\/li\u003e\n\u003cli\u003eตัวเรือนกะทัดรัดสำหรับพื้นที่ติดตั้งจำกัด\u003c\/li\u003e\n\u003cli\u003eทนความชื้นและการควบแน่นสูง\u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับเครื่องมือวินิจฉัยแบบพกพา\u003c\/li\u003e\n\u003cli\u003eการตอบสนองความถี่สูงสุด 6000 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสกิดคอมเพรสเซอร์แรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบการสั่นสะเทือนมอเตอร์\u003c\/li\u003e\n\u003cli\u003eชุดอุปกรณ์หมุน API\u003c\/li\u003e\n\u003cli\u003eชุดพัดลมและเครื่องเป่า\u003c\/li\u003e\n\u003cli\u003eระบบป้องกันปั๊ม\u003c\/li\u003e\n\u003cli\u003eแผงเครื่องจักร OEM\u003c\/li\u003e\n\u003cli\u003eแนวโน้มสุขภาพเครื่องจักรทั่วไป\u003c\/li\u003e\n\u003cli\u003eระบบอัตโนมัติกระบวนการ\u003c\/li\u003e\n\u003cli\u003eโครงการปรับปรุงการตรวจสอบการสั่นสะเทือน\u003c\/li\u003e\n\u003cli\u003eการติดตั้งเครื่องจักรขนาดกะทัดรัด\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรายการ\u003c\/th\u003e\n\u003cth\u003eการกำหนดค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003e990 - เครื่องส่งสัญญาณการสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e05 = 0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e50 = ความยาวระบบ 5.0 เมตร (16.4 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e01 = คลิปติดราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003e00 = ไม่จำเป็น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eรายละเอียด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขรุ่น\u003c\/td\u003e\n\u003ctd\u003e990-05-50-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมวดหมู่สินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเทศผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสัญญาณอินพุต\u003c\/td\u003e\n\u003ctd\u003eโพรบ proximity 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eรองรับสายต่อขยาย\u003c\/td\u003e\n\u003ctd\u003eระบบสายต่อ 5 เมตร และ 7 เมตร\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแรงดันไฟฟ้าแหล่งจ่าย\u003c\/td\u003e\n\u003ctd\u003eแรงดันไฟฟ้าแหล่งจ่าย +12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสัญญาณเอาต์พุต\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเอาต์พุต 4 ถึง 20 mAdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการกำหนดสายไฟ\u003c\/td\u003e\n\u003ctd\u003e2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e+\/-1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานวงจรสูงสุด\u003c\/td\u003e\n\u003ctd\u003e1000 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eกระแสจำกัด\u003c\/td\u003e\n\u003ctd\u003eกระแสจำกัดทั่วไป 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงช่องว่างโพรบ\u003c\/td\u003e\n\u003ctd\u003eช่วงช่องว่างโพรบ 0.5 ถึง 1.75 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานเอาต์พุต\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงเชิงเส้น Prox Out\u003c\/td\u003e\n\u003ctd\u003e1.4 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปัจจัยสเกลเพิ่มขึ้น\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/um (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงความถี่\u003c\/td\u003e\n\u003ctd\u003eช่วงความถี่ 5 Hz ถึง 6000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระดับเสียงรบกวนทั่วไป\u003c\/td\u003e\n\u003ctd\u003e50 mV\/pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003e9.5 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความยาวสายเคเบิลวินิจฉัย\u003c\/td\u003e\n\u003ctd\u003eสูงสุด 3 เมตร\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-52 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงานของโพรบ\u003c\/td\u003e\n\u003ctd\u003e-52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 100% ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุปลายโพรบ\u003c\/td\u003e\n\u003ctd\u003eโพลีฟีนิลีนซัลไฟด์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุตัวเรือนโพรบ\u003c\/td\u003e\n\u003ctd\u003eเหล็กกล้าไร้สนิม AISI 303 หรือ 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสายโพรบ\u003c\/td\u003e\n\u003ctd\u003eสายโคแอกเชียล FEP ฉนวน 75 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุป้องกันเสริม (ออปชัน)\u003c\/td\u003e\n\u003ctd\u003eเหล็กกล้าไร้สนิม AISI 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านแรงดึง\u003c\/td\u003e\n\u003ctd\u003e222 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความสูงตัวเครื่อง\u003c\/td\u003e\n\u003ctd\u003e42.6 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e63.5 มม. x 69.9 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e5.8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักสุทธิ\u003c\/td\u003e\n\u003ctd\u003e0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักรวมของระบบ\u003c\/td\u003e\n\u003ctd\u003e0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eอินเทอร์เฟซ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eขั้วต่อ PROX OUT\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตการสั่นสะเทือนแบบไดนามิก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขั้ว COM\u003c\/td\u003e\n\u003ctd\u003eสัญญาณร่วม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขา TEST\u003c\/td\u003e\n\u003ctd\u003eขาเข้าเพื่อตรวจสอบลูป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขั้วไฟฟ้า\u003c\/td\u003e\n\u003ctd\u003eขาเข้าแหล่งจ่ายไฟ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eลูป 4-20 mA\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเอาต์พุตของระบบควบคุม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eติดตั้งเครื่องส่งสัญญาณบนราง DIN ที่ต่อสายดินภายในตู้ครอบอุตสาหกรรมที่เหมาะสม\u003c\/li\u003e\n\u003cli\u003eรักษาช่องว่างระหว่างโพรบกับเป้าหมายให้ถูกต้องก่อนการปรับเทียบระบบ\u003c\/li\u003e\n\u003cli\u003eเดินสายเคเบิลทรานสดิวเซอร์แยกจากสายไฟแรงดันสูง\u003c\/li\u003e\n\u003cli\u003eใช้สายเคเบิลที่มีการป้องกันเพื่อลดสัญญาณรบกวนทางไฟฟ้า\u003c\/li\u003e\n\u003cli\u003eปกป้องขั้วต่อ PROX OUT จากความชื้นและการปนเปื้อน\u003c\/li\u003e\n\u003cli\u003eตรวจสอบแรงดันไฟฟ้าแหล่งจ่ายลูปก่อนเริ่มใช้งาน\u003c\/li\u003e\n\u003cli\u003eหลีกเลี่ยงการขันเกลียวโพรบเกินความจำเป็นในระหว่างการติดตั้ง\u003c\/li\u003e\n\u003cli\u003eใช้เครื่องมือวินิจฉัยแยกส่วนเมื่อเฝ้าดูรูปคลื่นการสั่นสะเทือน\u003c\/li\u003e\n\u003cli\u003eตรวจสอบให้แน่ใจว่ามีการระบายอากาศที่เหมาะสมรอบส่วนประกอบตู้ควบคุม\u003c\/li\u003e\n\u003cli\u003eยืนยันว่าค่าความต้านทานลูปอยู่ในขอบเขตที่กำหนด\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณส่งสัญญาณอะไรออกมา?\u003c\/strong\u003e\u003cbr\u003eอุปกรณ์ให้สัญญาณการสั่นสะเทือนแบบสัดส่วน 4 ถึง 20 mA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับโพรบในกลุ่มใด?\u003c\/strong\u003e\u003cbr\u003eเครื่องส่งสัญญาณออกแบบมาเพื่อใช้กับโพรบใกล้ 3300 NSv\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถติดตั้งเครื่องบนราง DIN ได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การกำหนดค่านี้รวมคลิปติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้ Proximitor ภายนอกหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ อิเล็กทรอนิกส์ของเซ็นเซอร์ Proximitor รวมอยู่ในตัวเครื่อง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องจักรประเภทใดที่มักใช้เครื่องส่งสัญญาณนี้?\u003c\/strong\u003e\u003cbr\u003eเครื่องอัดอากาศ ปั๊ม มอเตอร์ และพัดลมอุตสาหกรรมมักใช้เครื่องมือนี้\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณรองรับสถานที่อันตรายหรือไม่?\u003c\/strong\u003e\u003cbr\u003eการกำหนดค่านี้ไม่มีการอนุมัติสำหรับพื้นที่อันตราย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eความถี่การทำงานสูงสุดคือเท่าใด?\u003c\/strong\u003e\u003cbr\u003eการตอบสนองความถี่ขยายไปถึง 6000 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อมูลการสั่นสะเทือนถูกส่งไปยังระบบควบคุมอย่างไร?\u003c\/strong\u003e\u003cbr\u003eสัญญาณถูกส่งผ่านลูป 4 ถึง 20 mA สองสาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้การเชื่อมต่อ PROX OUT สำหรับการวินิจฉัยได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ ให้การเข้าถึงสัญญาณการสั่นสะเทือนแบบไดนามิกสำหรับการวิเคราะห์\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเกิดอะไรขึ้นในกรณีที่มีข้อผิดพลาดของโพรบ?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตจะลดลงต่ำกว่า 3.6 mA เพื่อแสดงสถานะ NOT OK\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eความยาวสายวินิจฉัยสูงสุดที่แนะนำคือเท่าใด?\u003c\/strong\u003e\u003cbr\u003eความยาวสูงสุดที่แนะนำคือ 3 เมตร\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสามารถทำงานในสภาพแวดล้อมที่มีความชื้นได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ โครงสร้างแบบพอตต์รองรับสภาวะความชื้นควบแน่น 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องการแรงดันไฟฟ้าแหล่งจ่ายเท่าใด?\u003c\/strong\u003e\u003cbr\u003eเครื่องส่งสัญญาณต้องการไฟฟ้าขาเข้า +12 ถึง +35 Vdc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์รองรับการวินิจฉัยรูปคลื่นผ่านเอาต์พุต 4-20 mA หรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ สัญญาณเอาต์พุตแบบอะนาล็อกมีไว้สำหรับการติดตามการสั่นสะเทือนโดยรวมเท่านั้น\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eมีใบรับรองแหล่งกำเนิดสินค้าหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ เอกสารรับรองแหล่งกำเนิดสินค้าสามารถจัดเตรียมได้ตามคำขอ\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666547896683,"sku":"990-05-50-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-50-01-00-vibration-transmitter-mb2ub5e3ozw_9a80da96-d09a-47be-bd35-7962f35dd3d4.jpg?v=1765440541"},{"product_id":"bently-nevada-990-04-50-01-01-2-wire-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-04-50-01-01 เครื่องส่งสัญญาณการสั่นสะเทือนแบบ 2 สาย","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-04-50-01-01\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณการสั่นสะเทือน 2 สายขนาดกะทัดรัดที่ออกแบบมาเพื่อการรวมสัญญาณการสั่นสะเทือนเพลาโดยตรงเข้าสู่ระบบควบคุมอุตสาหกรรม แปลงการเคลื่อนที่ของโพรบใกล้เป็นสัญญาณเอาต์พุตเชิงเส้น 4 ถึง 20 mA ช่วยให้ระบบ PLC และ DCS สามารถติดตามการสั่นสะเทือนอย่างต่อเนื่องและตรรกะการป้องกันพื้นฐาน\u003c\/p\u003e\n\u003cp\u003eเวอร์ชันนี้มักถูกเลือกเมื่อจำเป็นต้องปฏิบัติตาม CSA Division 2 พร้อมกับรูปแบบการติดตั้งราง DIN มาตรฐาน ในการใช้งานวิศวกรรมจริง จะติดตั้งบนอุปกรณ์หมุนที่ต้องการการตรวจสอบการสั่นสะเทือนที่เชื่อถือได้แต่ไม่ขึ้นกับระบบตรวจสอบแบบแร็คเต็มรูปแบบ\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณทำงานร่วมกับระบบโพรบใกล้ 3300 NSv และรองรับการกำหนดค่าความยาวระบบ 5.0 เมตร จากมุมมองภาคสนาม ทำให้เหมาะสำหรับการเดินสายโพรบระยะกลางภายในสกิดเครื่องอัด, ฐานปั๊ม และแผงเครื่องจักรที่บรรจุไว้\u003c\/p\u003e\n\u003cp\u003eเมื่อทำการติดตั้งแล้ว อุปกรณ์มักจะทำงานอย่างต่อเนื่องโดยมีการแทรกแซงน้อยที่สุด ตราบใดที่การจัดแนวโพรบและความเสถียรของพลังงานวงจรถูกตั้งค่าอย่างถูกต้องในระหว่างการเริ่มต้นใช้งาน\u003c\/p\u003e\n\u003ch3\u003eภาพรวมการทำงาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eแปลงสัญญาณการสั่นสะเทือนเพลาลงเป็นสัญญาณอนาล็อก 4–20 mA\u003c\/li\u003e\n\u003cli\u003eออกแบบสำหรับระบบโพรบใกล้ 3300 NSv\u003c\/li\u003e\n\u003cli\u003eการกำหนดค่าที่ได้รับการอนุมัติ CSA Division 2\u003c\/li\u003e\n\u003cli\u003eสถาปัตยกรรมวงจร 2 สายที่ใช้พลังงานจากวงจร\u003c\/li\u003e\n\u003cli\u003eการติดตั้งบนราง DIN โดยใช้คลิป 35 มม.\u003c\/li\u003e\n\u003cli\u003eอิเล็กทรอนิกส์ปรับสัญญาณในตัว\u003c\/li\u003e\n\u003cli\u003eความสามารถในการปรับศูนย์และสเกลภายนอก\u003c\/li\u003e\n\u003cli\u003eจุดเข้าถึงการวินิจฉัย PROX OUT\u003c\/li\u003e\n\u003cli\u003eการตรวจจับข้อผิดพลาดด้วยพฤติกรรมการลดกระแสเอาต์พุต\u003c\/li\u003e\n\u003cli\u003eการออกแบบตัวเรือนอุตสาหกรรมขนาดกะทัดรัดแบบปิดผนึก\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eบริบทการใช้งานทั่วไป\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eประเภทอุปกรณ์\u003c\/th\u003e\n\u003cth\u003eกรณีการใช้งานจริง\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องอัดแรงเหวี่ยง\u003c\/td\u003e\n\u003ctd\u003eการติดตามการสั่นสะเทือนอย่างต่อเนื่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปั๊มอุตสาหกรรม\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบสภาพแบริ่ง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eพัดลมและเครื่องเป่า\u003c\/td\u003e\n\u003ctd\u003eการตรวจจับความไม่สมดุล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชุดสกิด OEM\u003c\/td\u003e\n\u003ctd\u003eวงจรป้องกันในตัว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุปกรณ์เสริมสาธารณูปโภค\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเตือนไปยังระบบ PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องจักรกระบวนการ\u003c\/td\u003e\n\u003ctd\u003eจุดตรวจสอบสภาพพื้นฐาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eโครงสร้างการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eคำอธิบายรหัส\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e-04 = 0-4 mils pp (0-100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e-50 = ความยาวระบบ 5.0 เมตร (16.4 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e-01 = คลิปยึดราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003e-01 = CSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางกล\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรายการ\u003c\/th\u003e\n\u003cth\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n\u003ctd\u003e990-04-50-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสภาพ\u003c\/td\u003e\n\u003ctd\u003eใหม่ \u0026amp; ของแท้ในบรรจุภัณฑ์โรงงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการรับประกันจากโรงงาน\u003c\/td\u003e\n\u003ctd\u003e12 เดือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003e9.5 มม. (0.375 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความสูงตัวเครื่อง (ไม่รวมคลิป DIN)\u003c\/td\u003e\n\u003ctd\u003e42.6 มม.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง  \u003c\/td\u003e\n\u003ctd\u003e63.5 มม. x 69.9 มม.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง  \u003c\/td\u003e\n\u003ctd\u003e5.8 มม.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักเครื่องส่งสัญญาณ  \u003c\/td\u003e\n\u003ctd\u003e0.43 กก.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักรวมระบบ  \u003c\/td\u003e\n\u003ctd\u003e0.82 กก.  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eภาพรวมอินเทอร์เฟซ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eอินเทอร์เฟซ  \u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน  \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตโพรบ  \u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อโพรบ 3300 NSv  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุต 4–20 mA  \u003c\/td\u003e\n\u003ctd\u003eสัญญาณสั่นสะเทือนไปยังระบบควบคุม  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตพลังงาน  \u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ DC แบบใช้พลังงานจากลูป  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT  \u003c\/td\u003e\n\u003ctd\u003eสัญญาณวินิจฉัยสั่นสะเทือนดิบ  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM  \u003c\/td\u003e\n\u003ctd\u003eสัญญาณอ้างอิง  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกการติดตั้ง (แนวปฏิบัติทางวิศวกรรม)  \u003c\/h3\u003e\n\u003cp\u003eในการติดตั้งทั่วไป เครื่องส่งสัญญาณนี้จะติดตั้งบนราง DIN ภายในตู้ควบคุมใกล้กับระบบ I\/O ของ PLC จุดเน้นทางวิศวกรรมหลักไม่ใช่ตัวเครื่องส่งสัญญาณเอง แต่เป็นการเดินสายโพรบที่เสถียรและการปฏิบัติการต่อสายดินที่ถูกต้อง  \u003c\/p\u003e\n\u003cp\u003eการเดินสายควรหลีกเลี่ยงการเดินคู่ขนานกับสายเอาต์พุตอินเวอร์เตอร์หรือสายจ่ายมอเตอร์ โดยเฉพาะในสภาพแวดล้อมของสกิดเครื่องอัดอากาศที่มีสัญญาณรบกวนแม่เหล็กไฟฟ้าสูง การต่อสายดินและการป้องกันที่เหมาะสมเป็นสิ่งสำคัญสำหรับความเสถียรของสัญญาณ  \u003c\/p\u003e\n\u003cp\u003eในระหว่างการเริ่มใช้งาน ควรตรวจสอบกระแสลูปก่อนเปิดใช้งานตรรกะสัญญาณเตือน วิศวกรมักจะยืนยันการอ่านสั่นสะเทือนที่เสถียรภายใต้สภาวะเครื่องจักรที่คงที่ก่อนนำสัญญาณไปใช้กับระบบปิดเครื่องหรือเตือนภัย  \u003c\/p\u003e\n\u003cp\u003eใบรับรอง CSA Division 2 ทำให้การกำหนดค่านี้เหมาะสมสำหรับสถานที่อันตรายเฉพาะ ขึ้นอยู่กับการออกแบบระบบสุดท้ายและการปฏิบัติตามข้อกำหนดของตู้ครอบ  \u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย  \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของเครื่องส่งสัญญาณนี้คืออะไร?  \u003c\/strong\u003e\u003cbr\u003eมันแปลงสัญญาณสั่นสะเทือนจากโพรบใกล้เป็นสัญญาณ 4–20 mA สำหรับระบบควบคุม  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้ระบบโพรบใด?  \u003c\/strong\u003e\u003cbr\u003eออกแบบมาสำหรับระบบโพรบใกล้ Bently Nevada 3300 NSv  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอะไรที่ทำให้รุ่นนี้แตกต่าง?  \u003c\/strong\u003e\u003cbr\u003eรวมใบรับรอง CSA Division 2 สำหรับการใช้งานในพื้นที่อันตราย  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้โดยตรงกับ PLC ได้หรือไม่?  \u003c\/strong\u003e\u003cbr\u003eใช่ มันส่งออกสัญญาณแอนะล็อกมาตรฐานที่เข้ากันได้กับโมดูลอินพุต PLC  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eนี่คือระบบวินิจฉัยหรือไม่?  \u003c\/strong\u003e\u003cbr\u003eไม่ใช่ ระบบนี้ออกแบบมาสำหรับการติดตามสั่นสะเทือนพื้นฐานและตรรกะการป้องกัน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROX OUT ใช้ทำอะไร?  \u003c\/strong\u003e\u003cbr\u003eให้การเข้าถึงสัญญาณสั่นสะเทือนดิบสำหรับการวินิจฉัยบำรุงรักษา  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการติดตั้งบนราง DIN จำเป็นหรือไม่?  \u003c\/strong\u003e\u003cbr\u003eไม่ใช่ แต่เป็นวิธีการติดตั้งมาตรฐานและแนะนำ  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eหลักการทำงานคืออะไร?  \u003c\/strong\u003e\u003cbr\u003eมันแปลงการวัดการเคลื่อนที่เป็นสัญญาณกระแสไฟฟ้าสัดส่วน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโดยปกติจะติดตั้งที่ไหน?  \u003c\/strong\u003e\u003cbr\u003eภายในตู้ควบคุมสำหรับเครื่องอัดอากาศ ปั๊ม และเครื่องจักรหมุน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องการการปรับสัญญาณภายนอกหรือไม่?  \u003c\/strong\u003e\u003cbr\u003eไม่ใช่ การปรับสัญญาณถูกรวมเข้ากับตัวเครื่องอย่างสมบูรณ์  \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666563592555,"sku":"990-04-50-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-01-01-vibration-transmitter-mtt1xuabzyx_e5d68ee9-4136-4777-bac2-a1f09db3a28e.jpg?v=1765440700"},{"product_id":"bently-nevada-990-05-70-03-05-990-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-05-70-03-05 990 เครื่องส่งสัญญาณการสั่นสะเทือน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 990\u003c\/strong\u003e เป็นอุปกรณ์ตรวจสอบการสั่นสะเทือนแบบสองสาย ใช้พลังงานจากวงจร เหมาะสำหรับเครื่องอัดอากาศแรงเหวี่ยง, ปั๊ม, มอเตอร์ และพัดลมที่ต้องการเอาต์พุตการสั่นสะเทือนสัดส่วน 4 ถึง 20 mA สำหรับระบบควบคุมเครื่องจักร \u003cstrong\u003eBently Nevada\u003c\/strong\u003e พัฒนาเครื่องส่งสัญญาณนี้เพื่อการรวมเครื่องจักร OEM โดยเฉพาะ ซึ่งต้องการการติดตามการสั่นสะเทือนอย่างต่อเนื่องและฟังก์ชันป้องกันพื้นฐาน\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณรับสัญญาณจากโพรบใกล้ 3300 NSv และระบบสายต่อขยายที่เข้ากันได้ โดยปรับสัญญาณโพรบเป็นสัญญาณความกว้างการสั่นสะเทือนแบบพีคทูพีค และส่งออกสัญญาณสัดส่วน 4 ถึง 20 mA ไปยัง PLC, DCS หรือระบบควบคุมอัตโนมัติอื่น ๆ  \u003c\/p\u003e\n\u003cp\u003eการออกแบบเซ็นเซอร์ Proximitor แบบบูรณาการช่วยขจัดความจำเป็นในการใช้โมดูล proximitor ภายนอก ทำให้การติดตั้งในพื้นที่เครื่องจักรกะทัดรัดที่มีพื้นที่ติดตั้งจำกัดง่ายขึ้น อุปกรณ์ยังให้สัญญาณ PROX OUT แบบไม่แยกวงจรสำหรับการวินิจฉัยเครื่องจักรและการวิเคราะห์รูปคลื่น  \u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-70-03-05\u003c\/strong\u003e การกำหนดค่ารวมความยาวระบบทรานสดิวเซอร์ 7.0 ม., อุปกรณ์ติดตั้งราง DIN และสกรู, และการรับรองพื้นที่อันตรายที่เหมาะสมสำหรับการติดตั้ง Division 2 และ ATEX  \u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการออกแบบเซ็นเซอร์ Proximitor แบบบูรณาการ  \u003c\/li\u003e\n\u003cli\u003eเครื่องส่งสัญญาณแบบสองสาย ใช้พลังงานจากวงจร  \u003c\/li\u003e\n\u003cli\u003eเอาต์พุตการสั่นสะเทือนสัดส่วน 4 ถึง 20 mA  \u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับระบบโพรบใกล้ 3300 NSv  \u003c\/li\u003e\n\u003cli\u003eสัญญาณวินิจฉัย PROX OUT แบบไม่แยกวงจร  \u003c\/li\u003e\n\u003cli\u003eปรับศูนย์และสเกลภายนอก  \u003c\/li\u003e\n\u003cli\u003eรองรับการติดตั้งด้วยคลิปและสกรูบนราง DIN  \u003c\/li\u003e\n\u003cli\u003eฟังก์ชันปิดสัญญาณในสภาวะ NOT OK  \u003c\/li\u003e\n\u003cli\u003eทนความชื้นสูงถึง 100% การควบแน่น  \u003c\/li\u003e\n\u003cli\u003eการติดตั้งกะทัดรัดสำหรับเครื่องจักรแรงเหวี่ยง  \u003c\/li\u003e\n\u003cli\u003eการตอบสนองความถี่ตั้งแต่ 5 Hz ถึง 6000 Hz  \u003c\/li\u003e\n\u003cli\u003eได้รับการรับรองพื้นที่อันตราย CSA Division 2 และ ATEX  \u003c\/li\u003e\n\u003cli\u003eได้รับการรับรองทางทะเลจาก ABS  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเครื่องอัดอากาศแบบแรงเหวี่ยง  \u003c\/li\u003e\n\u003cli\u003eปั๊มอุตสาหกรรม  \u003c\/li\u003e\n\u003cli\u003eมอเตอร์ไฟฟ้า  \u003c\/li\u003e\n\u003cli\u003eพัดลมและเครื่องเป่ากระบวนการ  \u003c\/li\u003e\n\u003cli\u003eชุดอุปกรณ์หมุน OEM  \u003c\/li\u003e\n\u003cli\u003eการตรวจสอบการสั่นสะเทือนเครื่องจักรทั่วไป  \u003c\/li\u003e\n\u003cli\u003eระบบติดตามการสั่นสะเทือน PLC และ DCS  \u003c\/li\u003e\n\u003cli\u003eอุปกรณ์หมุนติดตั้งบนสไลด์  \u003c\/li\u003e\n\u003cli\u003eการติดตั้งเครื่องจักรขนาดกะทัดรัด  \u003c\/li\u003e\n\u003cli\u003eระบบตรวจสอบการสั่นสะเทือนในพื้นที่อันตราย  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรหัสรุ่น  \u003c\/th\u003e\n\u003cth\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 มิลลิเมตร pp (0-125 ไมครอน pp)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-70\u003c\/td\u003e\n\u003ctd\u003e7.0 เมตร (23.0 ฟุต)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-03\u003c\/td\u003e\n\u003ctd\u003eคลิปและสกรู DIN  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003eได้รับการรับรอง CSA Division 2, ATEX Zone 0, ATEX Zone 2 และ ABS สำหรับการเดินเรือ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eหมวดหมู่\u003c\/th\u003e\n\u003cth\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่นสินค้า\u003c\/td\u003e\n\u003ctd\u003e990-05-70-03-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทอินพุต\u003c\/td\u003e\n\u003ctd\u003eสายโพรบและสายต่อขยาย 3300 NSv Proximity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ +12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสัญญาณเอาต์พุต\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเอาต์พุต 4 ถึง 20 mAdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการกำหนดค่า\u003c\/td\u003e\n\u003ctd\u003eวงจร 2 สายจ่ายไฟ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำวงจร\u003c\/td\u003e\n\u003ctd\u003eความแม่นยำวงจร +\/-1.5% เต็มสเกล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานวงจรสูงสุด\u003c\/td\u003e\n\u003ctd\u003eความต้านทานวงจรสูงสุด 1000 โอห์ม ที่ 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eจำกัดกระแส\u003c\/td\u003e\n\u003ctd\u003eจำกัดกระแส 23 mA โดยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการตอบสนองความถี่\u003c\/td\u003e\n\u003ctd\u003eการตอบสนองความถี่ 5 Hz ถึง 6000 Hz (+0, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงช่องว่างโพรบ\u003c\/td\u003e\n\u003ctd\u003eช่วงช่องว่างโพรบ 0.5 ถึง 1.75 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานเอาต์พุต Prox Out\u003c\/td\u003e\n\u003ctd\u003eความต้านทานเอาต์พุต Prox Out 10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงเชิงเส้น Prox Out\u003c\/td\u003e\n\u003ctd\u003eช่วงเชิงเส้น Prox Out 1.4 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปัจจัยสเกลเพิ่มขึ้น\u003c\/td\u003e\n\u003ctd\u003eปัจจัยสเกลเพิ่มขึ้น 7.87 mV\/um (200 mV\/mil) +\/-6.5% โดยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความเสถียรของอุณหภูมิ\u003c\/td\u003e\n\u003ctd\u003eความเสถียรของอุณหภูมิ ภายใน +\/-10% จาก 0 องศาเซลเซียส ถึง +70 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลาง 9.5 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความยาวสายวินิจฉัยสูงสุด\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการใช้งาน\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการใช้งาน -35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา -52 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการใช้งานโพรบ\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษาโพรบ -52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษาโพรบ\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษาโพรบ -52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 100% คอนเดนเสท ไม่จมน้ำ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุปลายโพรบ\u003c\/td\u003e\n\u003ctd\u003eโพลีฟีนิลีนซัลไฟด์ (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวัสดุปลอกโพรบ\u003c\/td\u003e\n\u003ctd\u003eวัสดุปลอกโพรบสแตนเลส AISI 303 หรือ 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสายโพรบ\u003c\/td\u003e\n\u003ctd\u003eสายโคแอกเชียลหุ้มฉนวน FEP 75 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเกราะสายเคเบิลเสริม (อุปกรณ์เสริม)\u003c\/td\u003e\n\u003ctd\u003eสแตนเลส AISI 302 แบบยืดหยุ่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานแรงดึง\u003c\/td\u003e\n\u003ctd\u003eแรงดึงสูงสุด 222 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003eขนาด (สูง x กว้าง x ลึก) 53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความสูงตัวเครื่อง\u003c\/td\u003e\n\u003ctd\u003eความสูงตัวเครื่อง 42.6 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง 63.5 มม. x 69.9 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง 5.8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักเครื่องส่งสัญญาณ 0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd\u003eน้ำหนัก 0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eขาเชื่อมต่อ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตแรงสั่นสะเทือนและแรงดันช่องว่างแบบไดนามิก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eขั้วอ้างอิงทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตทดสอบ\u003c\/td\u003e\n\u003ctd\u003eอินพุตตรวจสอบสัญญาณวงจร\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eวงจร 4-20 mA\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตระบบควบคุมกระบวนการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตพลังงาน\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟ +12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eติดตั้งเครื่องส่งสัญญาณในกล่องอุตสาหกรรมที่แห้งและมีการกราวด์อย่างเหมาะสม\u003c\/li\u003e\n\u003cli\u003eรักษาช่องว่างของโพรบระหว่าง 0.5 มม. ถึง 1.75 มม. ในระหว่างการเริ่มใช้งาน\u003c\/li\u003e\n\u003cli\u003eใช้วิธีเดินสายเคเบิลที่มีการป้องกันเพื่อ ลดการรบกวน EMI และ RFI\u003c\/li\u003e\n\u003cli\u003eแยกสายสัญญาณออกจากสายมอเตอร์แรงดันสูง\u003c\/li\u003e\n\u003cli\u003eใช้คลิป DIN หรือสกรูติดตั้งที่จัดมาให้เพื่อการติดตั้งที่มั่นคง\u003c\/li\u003e\n\u003cli\u003eป้องกันขั้วต่อโคแอกเชียลจากความชื้นในสภาพแวดล้อมที่มีความชื้นสูง\u003c\/li\u003e\n\u003cli\u003eใช้ตัวแปลงสัญญาณทดสอบ 122115-01 เมื่อเชื่อมต่ออุปกรณ์วินิจฉัยที่ใช้ไฟ AC มีกราวด์\u003c\/li\u003e\n\u003cli\u003eตรวจสอบความต้านทานลูปไม่เกิน 1000 โอห์มที่ 35 Vdc\u003c\/li\u003e\n\u003cli\u003eหลีกเลี่ยงการขันเกลียวโพรบเกินขีดจำกัดที่แนะนำ\u003c\/li\u003e\n\u003cli\u003eตรวจสอบให้แน่ใจว่าการติดตั้งในพื้นที่อันตรายเป็นไปตามข้อบังคับไฟฟ้าท้องถิ่นที่เกี่ยวข้อง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eการรับรอง\u003c\/th\u003e\n\u003cth\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA Division 2\u003c\/td\u003e\n\u003ctd\u003eการรับรองพื้นที่อันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX โซน 0\u003c\/td\u003e\n\u003ctd\u003eการรับรองพื้นที่อันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX โซน 2\u003c\/td\u003e\n\u003ctd\u003eการรับรองพื้นที่อันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003ctd\u003eการรับรองทางทะเล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของเครื่องส่งสัญญาณ 990 คืออะไร?\u003c\/strong\u003e\u003cbr\u003eแปลงสัญญาณการสั่นสะเทือนจากโพรบใกล้เป็นเอาต์พุต 4 ถึง 20 mA ที่สัดส่วนสำหรับระบบตรวจสอบเครื่องจักร\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระบบโพรบใดที่เข้ากันได้กับเครื่องส่งสัญญาณนี้?\u003c\/strong\u003e\u003cbr\u003eอุปกรณ์รองรับโพรบใกล้ Bently Nevada 3300 NSv และสายต่อขยายที่เข้ากันได้\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสามารถให้สัญญาณการสั่นสะเทือนไดนามิกได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ ขั้วต่อ PROX OUT ให้สัญญาณทรานสดิวเซอร์ไดนามิกสำหรับการวินิจฉัย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณใช้พลังงานจากลูปหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ อุปกรณ์ทำงานเป็นอุปกรณ์สองสายที่ใช้พลังงานจากลูป\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับช่วงความถี่เท่าใด?\u003c\/strong\u003e\u003cbr\u003eช่วงการตอบสนองความถี่คือ 5 Hz ถึง 6000 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้สามารถใช้ในพื้นที่อันตรายได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การกำหนดค่านี้รวมการรับรอง CSA Division 2 และ ATEX\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณต้องการโมดูล proximitor ภายนอกหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ใช่ เซ็นเซอร์ Proximitor รวมอยู่ในเครื่องส่งสัญญาณแล้ว\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eแรงดันไฟฟ้าที่ต้องการคือเท่าใด?\u003c\/strong\u003e\u003cbr\u003eช่วงแรงดันไฟฟ้าที่ใช้งานได้คือ +12 ถึง +35 Vdc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชัน NOT OK ทำงานอย่างไร?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตจะลดลงต่ำกว่า 3.6 mA เมื่อเกิดข้อผิดพลาดของโพรบหรือปัญหาสัญญาณ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับวิธีการติดตั้งแบบใดบ้าง?\u003c\/strong\u003e\u003cbr\u003eอุปกรณ์รองรับการติดตั้งบนราง DIN และการติดตั้งด้วยสกรู\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสัญญาณ 4-20 mA สามารถใช้วิเคราะห์เฟสการสั่นสะเทือนได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ใช่ เอาต์พุตแบบแอนะล็อกให้ข้อมูลการติดตามการสั่นสะเทือนแบบพีคทูพีคเท่านั้น\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์วินิจฉัยใดที่ต้องใช้ตัวแปลงสัญญาณทดสอบ?\u003c\/strong\u003e\u003cbr\u003eเครื่องวัดและวิเคราะห์สัญญาณที่ใช้ไฟ AC ต่อสายดินควรใช้ตัวแปลงสัญญาณทดสอบ 122115-01\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณทนต่อระดับความชื้นได้เท่าใด?\u003c\/strong\u003e\u003cbr\u003eเครื่องส่งสัญญาณรองรับความชื้นควบแน่น 100% ในสภาพที่ไม่จมอยู่ใต้น้ำ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระยะสายเคเบิลวินิจฉัยสูงสุดจาก PROX OUT คือเท่าใด?\u003c\/strong\u003e\u003cbr\u003eระยะสายเคเบิลสูงสุดที่แนะนำคือ 3 เมตร\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณนี้เหมาะสำหรับการวินิจฉัยระบบ System 1 หรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ใช่ มีไว้สำหรับการติดตามการสั่นสะเทือนโดยรวมมากกว่าระบบวินิจฉัยไดนามิกเต็มรูปแบบ\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565034347,"sku":"990-05-70-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-03-05-vibration-transmitter-0nsgqefekgz_4637d253-b08f-4483-96d0-74828a468430.jpg?v=1765440723"},{"product_id":"bently-nevada-991-25-50-02-00-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-25-50-02-00 991 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eเครื่องส่งสัญญาณสัญญาณประมวลผล \u003cstrong\u003e991-25-50-02-00\u003c\/strong\u003e ถูกออกแบบมาเพื่อรับอินพุตจากระบบโพรบใกล้เคียงและเซ็นเซอร์เพื่อตรวจสอบการเคลื่อนที่แกนเพลาระดับไมโครนิ้ว โดยเฉพาะอย่างยิ่งในฐานะ \u003cstrong\u003eเครื่องส่งสัญญาณแรงดัน 991\u003c\/strong\u003e อุปกรณ์นี้ทำงานเป็นเครื่องส่งสัญญาณแบบลูป 2 สายที่ใช้พลังงานในตัว ซึ่งแปลงการวัดโพรบใกล้เคียงเป็นเอาต์พุตกระแส 4 ถึง 20 mA ที่สัดส่วนกับการเคลื่อนที่แรงดันรวมอย่างตรงไปตรงมา สามารถรวมเข้ากับโปรแกรมควบคุมลอจิกแบบตั้งโปรแกรม (\u003cstrong\u003ePLC\u003c\/strong\u003e) ระบบควบคุมแบบกระจาย (\u003cstrong\u003eDCS\u003c\/strong\u003e) และระบบเครื่องมือความปลอดภัย (\u003cstrong\u003eSIS\u003c\/strong\u003e) ได้อย่างราบรื่น ช่วยให้ผู้ปฏิบัติงานตั้งค่าการตรวจสอบแรงดันโดยไม่ต้องใช้ระบบป้องกันเครื่องจักรแบบแร็คเฉพาะ เครื่องส่งสัญญาณนี้ให้การปกป้องเครื่องจักรอย่างต่อเนื่องสำหรับอุปกรณ์หมุน เช่น เครื่องอัดแรงเหวี่ยง กังหันไอน้ำ ปั๊ม และพัดลมอุตสาหกรรม\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eรวมอินพุตเซ็นเซอร์โพรบใกล้เคียงแบบไม่สัมผัสด้วยกระแสไหลวนเข้ากับอินเทอร์เฟซลูป 2 สาย 4 ถึง 20 mA มาตรฐาน\u003c\/li\u003e\n\u003cli\u003eให้เอาต์พุตแรงดันแบบบัฟเฟอร์ผ่านขั้วต่อ BNC เฉพาะสำหรับเชื่อมต่อโดยตรงกับเครื่องวิเคราะห์การสั่นสะเทือนแบบพกพาและอุปกรณ์วินิจฉัย\u003c\/li\u003e\n\u003cli\u003eมีวงจรเฉพาะสำหรับการตรวจจับการสึกหรอตลับลูกปืนแรงดันล่วงหน้าหรือความล้มเหลวของการลอยตามแกนที่อาจเกิดขึ้น\u003c\/li\u003e\n\u003cli\u003eออกแบบตัวเรือนที่แข็งแรงและกะทัดรัด เหมาะกับการติดตั้งบนราง DIN ความหนาแน่นสูง\u003c\/li\u003e\n\u003cli\u003eมีวงจรป้องกันในตัวจากการต่อขั้วกลับและความผิดปกติของแรงดันไฟฟ้าเกิน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการเคลื่อนที่ตามแกนและตำแหน่งแรงดันบนเครื่องอัดแรงเหวี่ยงความเร็วสูง\u003c\/li\u003e\n\u003cli\u003eติดตามการสึกหรอของตลับลูกปืนแรงดันปั๊มป้อนน้ำในโรงไฟฟ้า\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบตำแหน่งแกนโรเตอร์ของกังหันไอน้ำและกังหันแก๊ส\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบสุขภาพเครื่องจักรกลของเทอร์โบชาร์จเจอร์และเครื่องขยายไอน้ำในอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eติดตามการเคลื่อนที่ของเพลามอเตอร์ไฟฟ้าขนาดใหญ่และเกียร์ลดรอบ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสตัวเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eประเภทการเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบาย\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกโพรบใกล้เคียง\u003c\/td\u003e\n\u003ctd\u003eโพรบใกล้เคียง 3300 XL 8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกช่วงสเกล\u003c\/td\u003e\n\u003ctd\u003eช่วง 50-0-50 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003eการอนุมัติหลายรายการ (ATEX, IECEx, CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการติดตั้งมาตรฐาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่พารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียดข้อกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e991-25-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณแรงดัน 991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแหล่งกำเนิด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทอินพุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eระบบโพรบใกล้เคียง 3300 XL 8 มม. และสายต่อขยาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทเอาต์พุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ถึง 20 mA DC (สัดส่วนเชิงเส้นกับการเคลื่อนที่ของแรงดัน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้องการพลังงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 ถึง 35 VDC ที่ขั้วส่งสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานลูป\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความต้านทานลูปสูงสุด 1000 โอห์ม ที่แรงดันไฟฟ้า 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเอาต์พุตแบบบัฟเฟอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วต่อ BNC แบบโคแอกเชียล ปัจจัยสเกลเอาต์พุตตามมาตรฐานของเซ็นเซอร์ใกล้เคียง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความแม่นยำ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eภายในช่วงเชิงเส้นที่กำหนดในอุณหภูมิการทำงานมาตรฐาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eราง DIN ขนาด 35 มม. หรือแผ่นติดตั้งบนแผงโดยตรง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81.3 มม. x 61.2 มม. x 103.4 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขาเชื่อมต่อ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+4-20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วบวกของวงจรกระแสไฟ \/ การเชื่อมต่อกระแสไฟออก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4-20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วลบของวงจรกระแสไฟ \/ การส่งคืนกระแสไฟ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวนำกลางสำหรับสายต่อขยายโพรบใกล้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSHIELD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วต่อสายป้องกันสายต่อขยาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดอ้างอิงทั่วไปสำหรับการทดสอบสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแจ็ค BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุตแรงดันแบบไดนามิก (สัญญาณโพรบใกล้ดิบ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งบนราง DIN:\u003c\/strong\u003e ติดตั้งตัวเครื่องบนราง DIN แบบหมวกทรงสมมาตรขนาด 35 มม. โดยให้คลิปบนและล่างยึดแน่น\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการกราวด์:\u003c\/strong\u003e เชื่อมต่อตัวเครื่องส่งสัญญาณโดยตรงกับกราวด์สะอาดของเครื่องมือวัดในพื้นที่หรือบล็อกกราวด์ราง DIN เพื่อหลีกเลี่ยงแรงดันลอยตัว\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการป้องกัน:\u003c\/strong\u003e ต่อสายป้องกันภายนอกของสายไฟภาคสนามที่ปลายระบบควบคุมเท่านั้น; ตรวจสอบให้แน่ใจว่าสายป้องกันโพรบเชื่อมต่อโดยตรงกับขั้วป้องกันของเครื่องส่งสัญญาณและแยกจากกล่องต่อสาย\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการลดสัญญาณรบกวน EMI\/RFI:\u003c\/strong\u003e เดินสายเคเบิลอินพุตเซ็นเซอร์ใกล้ระดับต่ำทั้งหมดในท่อโลหะกราวด์แยกต่างหากที่แยกจากสายไฟฟ้ากระแสสลับแรงสูง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับช่องว่างโพรบ:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าโพรบใกล้ถูกตั้งช่องว่างให้ตรงกับช่วงแรงดันไฟฟ้าทางกายภาพที่ถูกต้องก่อนยึดการตั้งค่าการเชื่อมต่อวงจรเครื่องส่งสัญญาณเพื่อเพิ่มประสิทธิภาพเชิงเส้นแบบไดนามิกสูงสุด\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการป้องกันความชื้น:\u003c\/strong\u003e ติดตั้งอุปกรณ์ภายในกล่องที่มีมาตรฐาน IP65 หรือ NEMA 4X เมื่อใช้งานในสภาพแวดล้อมกลางแจ้งที่มีความชื้นสูงหรือมีสารกัดกร่อนในอากาศ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA\/NRTL\/C\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของเครื่องส่งสัญญาณนี้คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eแปลงสัญญาณโพรบใกล้ความถี่สูงเป็นสัญญาณกระแสวงจรเชิงเส้นมาตรฐาน 4 ถึง 20 mA ที่แสดงตำแหน่งแกนหรือแรงดันเพลาขับ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้ต้องการสายจ่ายไฟแยกต่างหากหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ใช่ เป็นอุปกรณ์สองสายที่ใช้พลังงานจากวงจรโดยใช้แรงดันวงจรที่ได้รับจากโมดูลอินพุตอนาล็อก DCS หรือ PLC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องเก็บข้อมูลแบบพกพาเชื่อมต่ออย่างไรเพื่อตรวจสอบข้อมูลการสั่นสะเทือนดิบ?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเครื่องวิเคราะห์แบบพกพาหรือออสซิลโลสโคปสามารถเชื่อมต่อโดยตรงกับแจ็ค BNC ด้านหน้าโดยไม่รบกวนวงจรควบคุมอัตโนมัติ 4 ถึง 20 mA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระบบเซ็นเซอร์ใกล้ชนิดใดที่เข้ากันได้กับรหัสตัวเลือก 25?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตัวเลือก 25 ระบุความเข้ากันได้กับระบบโพรบใกล้ Bently Nevada 3300 XL ขนาด 8 มม. และสายต่อขยาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้สามารถติดตั้งโดยตรงในสภาพแวดล้อมกลางแจ้งที่รุนแรงได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eต้องการกล่องป้องกันที่มีมาตรฐานเหมาะสมเพื่อปกป้องขั้วต่ออิเล็กทรอนิกส์จากความชื้น ฝุ่น และสารกัดกร่อนในอากาศ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eผลกระทบของการกลับขั้ววงจรอินพุตคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eอุปกรณ์นี้มีวงจรป้องกันขั้วกลับภายในที่ป้องกันความเสียหายทางไฟฟ้า แม้ว่าจะไม่ส่งสัญญาณที่ถูกต้องจนกว่าจะเดินสายอย่างถูกต้อง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้ต้องการการปรับเทียบตามระยะเวลาปกติในภาคสนามหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ใช่ อุปกรณ์นี้ได้รับการปรับเทียบจากโรงงานสำหรับช่วงเชิงเส้นเฉพาะและไม่จำเป็นต้องปรับหรือปรับแต่งด้วยมือในระหว่างการติดตั้งมาตรฐาน\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666565624171,"sku":"991-25-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-50-02-00-thrust-transmitter-omubwe2j10e_9be2c544-1e3f-4c84-9fe9-07d1aa5c49ac.jpg?v=1765440731"},{"product_id":"bently-nevada-990-04-50-01-cn-2-wire-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-04-50-01-CN เครื่องส่งสัญญาณสั่นสะเทือน 2 สาย","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e990-04-50-01-CN\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณการสั่นสะเทือนแบบใช้สายลูปที่ออกแบบมาสำหรับเครื่องจักรที่ต้องแปลงการสั่นสะเทือนเป็นสัญญาณมาตรฐาน 4 ถึง 20 mA สำหรับใช้ในระบบควบคุม โดยทั่วไปใช้ในชุดอุปกรณ์หมุนขนาดกะทัดรัดที่วิศวกรต้องการข้อมูลแนวโน้มที่เสถียรโดยไม่ต้องติดตั้งระบบตรวจสอบแบบแร็คเต็มรูปแบบ\u003c\/p\u003e\n\u003cp\u003eการกำหนดค่ารุ่น CN นี้ถูกเลือกเมื่อความต้องการการปฏิบัติตามมาตรฐานและการรับรองในภูมิภาคเป็นส่วนหนึ่งของข้อกำหนดโครงการ ในการติดตั้งจริงหลายแห่ง สิ่งนี้มีความสำคัญสำหรับชุดอุปกรณ์ที่มุ่งเน้นการส่งออกหรือการออกแบบ OEM มาตรฐานที่ใช้ในหลายไซต์\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณประมวลผลข้อมูลจากระบบโพรบ 3300 NSv และแปลงการสั่นสะเทือนของเพลาขับเป็นสัญญาณไฟฟ้าสัดส่วนสำหรับอินพุต PLC หรือ DCS ความยาวระบบ 5.0 เมตรเหมาะสำหรับการเดินสายโพรบระยะกลางในรูปแบบเครื่องจักรติดตั้งบนสกิด\u003c\/p\u003e\n\u003cp\u003eจากมุมมองวิศวกรรมภาคสนาม รุ่นนี้มักถูกเลือกเมื่อความต้องการการปฏิบัติตามมาตรฐานและการติดตั้งที่ง่ายต้องสมดุลกันภายในพื้นที่ตัวเรือนขนาดเล็ก\u003c\/p\u003e\n\u003ch3\u003eลักษณะทางวิศวกรรม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสถาปัตยกรรมการวัดการสั่นสะเทือนแบบใช้สายลูป 2 เส้น\u003c\/li\u003e\n\u003cli\u003eแปลงการเคลื่อนที่ของโพรบใกล้เข้าหาเป็นสัญญาณเอาต์พุต 4 ถึง 20 mA\u003c\/li\u003e\n\u003cli\u003eออกแบบให้เข้ากันได้กับระบบโพรบ 3300 NSv\u003c\/li\u003e\n\u003cli\u003eติดตั้งบนราง DIN โดยใช้คลิปมาตรฐาน 35 มม.\u003c\/li\u003e\n\u003cli\u003eอิเล็กทรอนิกส์ปรับสัญญาณแบบบูรณาการ (ไม่ต้องใช้โมดูลภายนอก)\u003c\/li\u003e\n\u003cli\u003eสัญญาณเอาต์พุตเสถียรสำหรับการติดตามแนวโน้มการสั่นสะเทือนอย่างต่อเนื่อง\u003c\/li\u003e\n\u003cli\u003eเข้าถึงการปรับศูนย์และสเกลภายนอกได้\u003c\/li\u003e\n\u003cli\u003eมี PROX OUT สำหรับตรวจสอบรูปคลื่นวินิจฉัย\u003c\/li\u003e\n\u003cli\u003eการตรวจจับข้อผิดพลาดพร้อมการแสดงผลการลดสัญญาณอัตโนมัติ\u003c\/li\u003e\n\u003cli\u003eตัวเรือนปิดผนึกขนาดกะทัดรัดสำหรับสภาพแวดล้อมอุตสาหกรรม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eบริบทการใช้งาน\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eประเภทเครื่องจักร\u003c\/th\u003e\n\u003cth\u003eการใช้งานจริง\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องอัดแรงเหวี่ยง\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบแนวโน้มการสั่นสะเทือนเพลาขับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปั๊มอุตสาหกรรม\u003c\/td\u003e\n\u003ctd\u003eการติดตามสภาพแบริ่ง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eพัดลมกระบวนการ\u003c\/td\u003e\n\u003ctd\u003eการตรวจจับความไม่สมดุลและการสึกหรอทางกล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสกิดแพ็คเกจ OEM\u003c\/td\u003e\n\u003ctd\u003eอินพุตป้องกันแบบบูรณาการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระบบหมุนเสริม\u003c\/td\u003e\n\u003ctd\u003eตรรกะสัญญาณเตือนพื้นฐานบน PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชุดอุปกรณ์สำหรับส่งออก\u003c\/td\u003e\n\u003ctd\u003eการสร้างตามมาตรฐานการปฏิบัติตาม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eโครงสร้างการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรายการ\u003c\/th\u003e\n\u003cth\u003eคำอธิบายรหัส\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกสเกลเต็ม\u003c\/td\u003e\n\u003ctd\u003e-04 = 0-4 mils pp (0-100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e-50 = ความยาว 5.0 เมตร (16.4 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e-01 = คลิปติดราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003e-CN = การปฏิบัติตามมาตรฐานจีน \/ NEPSI \/ CCC \/ ATEX \/ IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางกล\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n\u003ctd\u003e990-04-50-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสภาพ\u003c\/td\u003e\n\u003ctd\u003eใหม่ \u0026amp; ของแท้ในบรรจุภัณฑ์โรงงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการรับประกันจากโรงงาน\u003c\/td\u003e\n\u003ctd\u003e12 เดือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003e9.5 มม. (0.375 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความสูงตัวเครื่อง (ไม่รวมคลิปราง DIN)\u003c\/td\u003e\n\u003ctd\u003e42.6 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e63.5 มม. x 69.9 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e5.8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd\u003e0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd\u003e0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eภาพรวมอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eอินเทอร์เฟซ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตตัวตรวจจับ\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อตัวตรวจจับ 3300 NSv proximity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุต 4-20 mA\u003c\/td\u003e\n\u003ctd\u003eสัญญาณการสั่นสะเทือนไปยังระบบ PLC\/DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตพลังงาน\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟวงจร +12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eสัญญาณวินิจฉัยการสั่นสะเทือนดิบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eจุดอ้างอิงสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกการติดตั้ง (มุมมองการปฏิบัติภาคสนาม)\u003c\/h3\u003e\n\u003cp\u003eในการติดตั้งตู้ทั่วไป วิศวกรจะติดตั้งโมดูลนี้บนราง DIN แล้วตรวจสอบความมั่นคงทางกลขึ้นอยู่กับการสัมผัสการสั่นสะเทือนของตู้ สำหรับระบบติดตั้งบนสกิด บางครั้งจะเพิ่มการยึดเพิ่มเติมเพื่อป้องกันการเคลื่อนไหวเล็กน้อยในระหว่างรอบการทำงานยาวนาน\u003c\/p\u003e\n\u003cp\u003eการวางสายเคเบิลควรวางแผนตั้งแต่ต้นในออกแบบตู้ ควรแยกสายสัญญาณตัวตรวจจับออกจากสายไฟมอเตอร์หรืออินเวอร์เตอร์เพื่อลดสัญญาณรบกวน โดยเฉพาะในระบบที่มีความยาว 5 เมตรซึ่งมักจะมัดรวมกัน\u003c\/p\u003e\n\u003cp\u003eก่อนการติดตั้ง ควรตรวจสอบการจัดแนวช่องว่างของตัวตรวจจับอย่างระมัดระวัง เมื่อเปิดใช้งานแล้ว ให้รอให้วงจรเสถียรก่อนเปิดใช้งานตรรกะสัญญาณเตือนในระบบควบคุม\u003c\/p\u003e\n\u003cp\u003eอินเทอร์เฟซ PROX OUT โดยทั่วไปใช้ในระหว่างการติดตั้งหรือแก้ไขปัญหา มากกว่าการใช้งานต่อเนื่องในระบบการผลิต\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eวัตถุประสงค์ของคำต่อท้าย CN ในรุ่นนี้คืออะไร?\u003c\/strong\u003e\u003cbr\u003eมันแสดงถึงการกำหนดค่าที่สอดคล้องกับข้อกำหนดการรับรองในภูมิภาคที่ใช้ในโครงการอุตสาหกรรมบางแห่ง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณนี้เหมาะสำหรับการรวมกับ PLC หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันให้เอาต์พุตมาตรฐาน 4 ถึง 20 mA ที่เข้ากันได้กับอินพุตอนาล็อกของ PLC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับระบบตัวตรวจจับแบบใด?\u003c\/strong\u003e\u003cbr\u003eมันถูกออกแบบมาสำหรับระบบตัวตรวจจับ Bently Nevada 3300 NSv proximity\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้ในอุปกรณ์ที่มุ่งเน้นการส่งออกได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันมักถูกเลือกสำหรับการกำหนดค่าการส่งออก OEM ที่เป็นมาตรฐาน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการติดตั้งราง DIN เป็นมาตรฐานสำหรับรุ่นนี้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันใช้การติดตั้งแบบคลิปราง DIN ขนาด 35 มม.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรองรับการวินิจฉัยการสั่นสะเทือนหรือไม่?\u003c\/strong\u003e\u003cbr\u003eมันให้สัญญาณ PROX OUT สำหรับการตรวจสอบรูปคลื่นวินิจฉัยพื้นฐาน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eนี่คือระบบตรวจสอบเต็มรูปแบบหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ มันเป็นเครื่องส่งสัญญาณแบบง่ายสำหรับการตรวจสอบระดับแนวโน้ม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นถ้าตัวตรวจจับล้มเหลว?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตลดลงถึงระดับกระแสผิดปกติซึ่งบ่งชี้สภาพ NOT OK\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eช่วงอุณหภูมิการทำงานคืออะไร?\u003c\/strong\u003e\u003cbr\u003eมันทำงานได้ในช่วงอุณหภูมิ -35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้กับคอมเพรสเซอร์และปั๊มได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มันถูกนำไปใช้กันอย่างแพร่หลายในเครื่องจักรหมุน เช่น คอมเพรสเซอร์และปั๊ม\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666568900971,"sku":"990-04-50-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-01-cn-vibration-transmitter-iwllhxzlwmi_75cfc6c9-5210-4bb3-b53d-01f25dc24b32.jpg?v=1765440797"},{"product_id":"bently-nevada-990-05-70-01-05-2-wire-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-05-70-01-05 เครื่องส่งสัญญาณการสั่นสะเทือนแบบ 2 สาย","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-70-01-05\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณสั่นสะเทือนแบบ 2 สาย ใช้พลังงานจากวงจร เพื่อรวมการป้องกันเครื่องจักรอย่างต่อเนื่องเข้ากับระบบควบคุมแบบกระจาย (DCS), ตัวควบคุมลอจิกแบบโปรแกรมได้ (PLC) หรือสถาปัตยกรรม SCADA อุตสาหกรรมมาตรฐาน มันปรับสัญญาณโพรบระยะห่างดิบให้เป็นวงจรกระแส 4-20 mA แบบเส้นตรงและสัดส่วนที่แสดงการสั่นสะเทือนรัศมีรวม หรือการเคลื่อนที่ไดนามิกของเพลา\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณนี้เชื่อมต่อโดยตรงกับระบบโพรบกระแสวนแม่เหล็กแบบไม่สัมผัส โดยแปลงสัญญาณในพื้นที่โดยไม่ต้องใช้แร็คตรวจสอบเครื่องจักรกลาง ฮาร์ดแวร์จัดการการขับโพรบความถี่สูงและถอดรหัสสัญญาณกลับเพื่อดึงแนวโน้มการเคลื่อนที่ยอดถึงยอด มันรักษาความเข้ากันได้เต็มรูปแบบกับทรานสดิวเซอร์ระยะห่างเฉพาะและสายต่อขยายที่สอบเทียบเพื่อให้ได้ปัจจัยสเกลที่แม่นยำและเสถียรภายใต้สภาพแวดล้อมอุตสาหกรรมที่หลากหลาย\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสัญญาณขาออกวงจรกระแส 4-20 mA มาตรฐานที่สัดส่วนกับการสั่นสะเทือนเครื่องจักรแบบยอดถึงยอด\u003c\/li\u003e\n\u003cli\u003eความสามารถเชื่อมต่อโดยตรงกับระบบโพรบตรวจจับระยะห่าง 3300 NSv\u003c\/li\u003e\n\u003cli\u003eอิเล็กทรอนิกส์ปรับสัญญาณแบบบูรณาการในตัวเรือนที่ทนทานและติดตั้งภาคสนามได้\u003c\/li\u003e\n\u003cli\u003eฮาร์ดแวร์ติดตั้งบนราง DIN ขนาด 35 มม. สำหรับการติดตั้งในตู้ควบคุมความหนาแน่นสูง\u003c\/li\u003e\n\u003cli\u003eความทนทานต่อแรงดันไฟฟ้าขาเข้ากว้างเพื่อรองรับความต้านทานวงจรในอุตสาหกรรมที่แตกต่างกัน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการสั่นสะเทือนเพลารัศมีบนปั๊มความเร็วสูงและเครื่องอัดแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eการติดตามการสั่นสะเทือนโครงสร้างและที่อยู่อาศัยลูกปืนบนพัดลมและเครื่องเป่าลมอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eวงจรป้องกันมอเตอร์ไฟฟ้า เครื่องกำเนิดไฟฟ้า และเครื่องจักรหมุนเสริม\u003c\/li\u003e\n\u003cli\u003eการรวมอุปกรณ์ส่วนที่เหลือของโรงงานเข้ากับระบบควบคุมโรงงานมาตรฐาน\u003c\/li\u003e\n\u003cli\u003eการบันทึกวงจรบำรุงรักษาเชิงคาดการณ์ในโรงงานปิโตรเคมี น้ำมัน ก๊าซ และพลังงาน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eบล็อกตัวเลือกโมเดล\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนดการกำหนดค่า\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกช่วงเต็มสเกล: 0-5 มิลลิเมตร pp (0-125 ไมโครเมตร pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ: 7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง: ราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการรับรองจากหน่วยงาน: CSA, ATEX, IECEx ปลอดภัยในตัว \u0026 ไม่ก่อให้เกิดประกายไฟ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eค่า\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่นพื้นฐาน\u003c\/td\u003e\n\u003ctd\u003e990-05-70-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกช่วงเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e0-5 มิลลิเมตร pp (0-125 ไมโครเมตร pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขาเข้า\u003c\/td\u003e\n\u003ctd\u003eรองรับโพรบตรวจจับระยะห่างแบบไม่สัมผัส 3300 NSv และสายต่อขยาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eข้อกำหนดพลังงาน\u003c\/td\u003e\n\u003ctd\u003eต้องการแรงดันไฟฟ้า +12 ถึง +35 Vdc ที่ขั้วส่งสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสัญญาณขาออก\u003c\/td\u003e\n\u003ctd\u003eวงจรกระแส 4-20 mA แบบสัดส่วน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-51 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักจัดส่ง\u003c\/td\u003e\n\u003ctd\u003e1.5 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเทศผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eขั้ว \/ พอร์ต\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROBE\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อโคแอกเชียลกับสายต่อขยาย 3300 NSv และโพรบระยะใกล้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eขั้วกราวด์ลูปทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+4-20 mA\u003c\/td\u003e\n\u003ctd\u003eขั้วจ่ายไฟบวกและเอาต์พุตวงจรกระแส 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAP\u003c\/td\u003e\n\u003ctd\u003eขั้วเอาต์พุตแรงดันไฟฟ้าบัฟเฟอร์สำหรับการตั้งค่าช่องว่างโพรบและการวินิจฉัย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งบนราง DIN:\u003c\/strong\u003e ติดตั้งฐานเครื่องส่งสัญญาณอย่างแน่นหนาบนราง DIN ขนาดมาตรฐาน 35 มม. ภายในตู้ป้องกันสิ่งแวดล้อม ตรวจสอบให้โมดูลถูกยึดอย่างมั่นคงเพื่อป้องกันการเลื่อนหรือการตัดการเชื่อมต่อทางกลที่เกิดจากการสั่นสะเทือนของตู้\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับช่องว่างโพรบ:\u003c\/strong\u003e ใช้โวลต์มิเตอร์ดิจิทัลที่เชื่อมต่อขนานกับขั้ว GAP และ COM เพื่อวัดแรงดันไฟฟ้ากระแสตรงแบบคงที่ ปรับช่องว่างทางกลของโพรบระยะใกล้ 3300 NSv จนถึงแรงดันไบแอสเป้าหมาย เพื่อให้ทำงานภายในโซนเชิงเส้นของเซ็นเซอร์\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเดินสายและการป้องกัน:\u003c\/strong\u003e เดินสายต่อขยายยาว 7.0 เมตรผ่านท่อเหล็กที่มีกราวด์เฉพาะ หลีกเลี่ยงสายไฟฟ้ากระแสสลับที่มีกระแสสูง เชื่อมต่อระบบป้องกันสายทั้งหมดกับกราวด์เครื่องมือที่กำหนดไว้ที่แผงควบคุมเพื่อลดการรบกวนทางแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eข้อควรระวังในพื้นที่อันตราย:\u003c\/strong\u003e สำหรับสภาพแวดล้อมที่ต้องการการติดตั้งที่ปลอดภัยโดยเนื้อแท้ ให้ติดตั้งอุปกรณ์กั้นเซเนอร์หรืออุปกรณ์แยกกัลวานิกที่ได้รับอนุมัติในวงจรลูประหว่างแหล่งจ่ายไฟและขั้วต่อเครื่องส่งสัญญาณอย่างเคร่งครัดตามรหัสไฟฟ้าท้องถิ่น\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเซ็นเซอร์อินพุตใดที่จำเป็นสำหรับรุ่นเครื่องส่งสัญญาณนี้โดยเฉพาะ?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eอุปกรณ์ต้องเชื่อมต่อกับโพรบระยะใกล้ 3300 NSv แบบไม่สัมผัสจำนวนหนึ่งตัวและสายต่อขยายที่จับคู่กันซึ่งกำหนดความยาวระบบที่สอบเทียบแล้วรวม 7.0 เมตรพอดี\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eคุณตรวจสอบการตั้งค่าช่องว่างทางกายภาพของโพรบโดยไม่ถอดเซ็นเซอร์อย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณมีขั้วต่อ GAP ที่เข้าถึงได้จากด้านหน้าโดยเฉพาะ ซึ่งให้เอาต์พุตแรงดันไฟฟ้ากระแสตรงดิบที่สัดส่วนโดยตรงกับระยะทางทางกายภาพระหว่างปลายโพรบกับพื้นผิวเพลาที่สังเกต\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรุ่นเครื่องส่งสัญญาณนี้สามารถติดตั้งในสภาพแวดล้อมอุตสาหกรรมที่เป็นอันตรายได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ การกำหนดค่าพิเศษนี้รวมตัวเลือกการอนุมัติจากหน่วยงาน 05 ซึ่งรับรองอุปกรณ์สำหรับการใช้งานที่ปลอดภัยโดยเนื้อแท้และไม่ก่อให้เกิดประกายไฟภายใต้มาตรฐาน CSA, ATEX และ IECEx เมื่อจับคู่กับอุปกรณ์กั้นแยกที่เหมาะสม\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666578010475,"sku":"990-05-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-01-05-990-vibration-transmitter-la4e1lndz3l_a78e6b5e-9fed-4b4e-b275-1ac715aa5cdf.jpg?v=1765440931"},{"product_id":"bently-nevada-990-05-70-03-00-990-vibration-transmitter","title":"Bently Nevada 990-05-70-03-00 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-50-02-00\u003c\/strong\u003e is a 2-wire, loop-powered device designed to provide continuous machinery vibration monitoring directly to a distributed control system (DCS), programmable logic controller (PLC), or machinery protection architecture. It conditions signals from proximity probes to output a proportional 4-20 mA current loop, representing total radial vibration or axial thrust measurement.\u003c\/p\u003e\n\u003cp\u003eThis transmitter interfaces directly with a non-contacting eddy current probe system to log dynamic shaft displacement. The hardware conversion architecture extracts the peak-to-peak or static position trends without requiring an intermediate machinery monitoring rack, making it suitable for standard control loops. It maintains full system compatibility with specific proximity probe sub-assemblies and calibrated cable lengths to ensure accurate scale-factor linear output.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 4-20 mA current loop output proportional to machinery vibration\u003c\/li\u003e\n\u003cli\u003eDirect interface capability with 3300 NSv proximity probe systems\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning inside a compact, field-mountable enclosure\u003c\/li\u003e\n\u003cli\u003eBulkhead screw mounting hardware for rigid installation on machine housings\u003c\/li\u003e\n\u003cli\u003eWide input voltage range to accommodate varying loop load requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring on small centrifugal pumps and compressors\u003c\/li\u003e\n\u003cli\u003eAxial shaft displacement measurements on industrial fans and blowers\u003c\/li\u003e\n\u003cli\u003eElectric motor and generator bearing housing vibration tracking\u003c\/li\u003e\n\u003cli\u003eAuxiliary rotating machinery protection loops in petrochemical facilities\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant equipment integration into factory control architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Option Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale Option: 0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option: 5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: Bulkhead screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct No.\u003c\/td\u003e\n\u003ctd\u003e990-05-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc input at the transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 Celsius to +85 Celsius (-31 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 Celsius to +100 Celsius (-60 Fahrenheit to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Mount the transmitter base securely onto a flat bulkhead surface using the pre-selected bulkhead screw hardware option. Ensure the surface is free of high vibration spikes that could fatigue the internal board electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Ensure the 3300 NSv proximity probe is mechanically adjusted to its physical mid-range voltage point before finalizing the locknut installation. This adjustment keeps the transducer within its accurate linear operating zone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Shielding:\u003c\/strong\u003e Route the 5.0-meter extension cable through dedicated conduit paths separate from high-voltage motor lines. Bond the overall cable shield firmly to the designated instrumentation ground point at the receiver chassis to mitigate electromagnetic field noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify that the loop power supply source provides clean, regulated direct current within the +12 to +35 Vdc operating range prior to terminating the wires at the input blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific sensor input does this unit support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter accepts exactly one non-contacting 3300 NSv proximity probe along with its matching extension cable configured for a total system length of 5.0 meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this configuration carry hazardous area certifications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit option code includes the 00 modification block, meaning agency approval is not required or provided for this specific product variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the device powered during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter functions as a standard loop-powered module, requiring an external loop supply voltage between +12 and +35 Vdc connected directly across its terminal interface.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666611499371,"sku":"990-05-70-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-03-00-990-vibration-transmitter-fqbqosjzjqi_3635d761-ebf9-4839-a401-aaba4f21b80e.jpg?v=1765444147"},{"product_id":"bently-nevada-990-04-50-03-00-2-wire-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-04-50-03-00 เครื่องส่งสัญญาณการสั่นสะเทือนแบบ 2 สาย","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eคือ \u003cstrong\u003e990-04-50-03-00\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณการสั่นสะเทือนขนาดกะทัดรัดที่ใช้สำหรับรวมการวัดการสั่นสะเทือนเพลาลงในระบบควบคุมโดยไม่ต้องใช้แร็คตรวจสอบเต็มรูปแบบ ออกแบบโดยใช้สถาปัตยกรรมวงจร 2 สายที่ใช้พลังงานจากวงจร และแปลงสัญญาณการเคลื่อนที่ของโพรบใกล้เคียงเป็นเอาต์พุต 4 ถึง 20 mA ที่เสถียรสำหรับใช้งานกับ PLC หรือ DCS\u003c\/p\u003e\n\u003cp\u003eในการติดตั้ง OEM ที่ใช้งานจริง รุ่นนี้มักถูกเลือกเมื่อวิศวกรต้องการความสมดุลระหว่างความเรียบง่ายของสายไฟและความยืดหยุ่นทางกล ความยาวระบบ 5.0 เมตรเหมาะกับการจัดวางอุปกรณ์หมุนบนสกิดส่วนใหญ่ที่มีระยะทางเดินสายโพรบปานกลางแต่ยังต้องการความเสถียรของสัญญาณ\u003c\/p\u003e\n\u003cp\u003eการกำหนดค่านี้ใช้วิธีการติดตั้งแบบผสมผสานระหว่างคลิป DIN และสกรู ซึ่งให้ความยืดหยุ่นแก่ช่างเทคนิคในระหว่างการจัดวางแผง ในการติดตั้งจริงหลายกรณี วิธีการติดตั้งแบบไฮบริดนี้เป็นที่นิยมเพราะช่วยให้ติดตั้งบนรางได้รวดเร็วและเสริมความแข็งแรงทางกลเพิ่มเติมเมื่อมีการสั่นสะเทือนสูงกว่าปกติ\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณนี้มักใช้ในวงจรป้องกันพื้นฐานหรือการติดตามสภาพ โดยมีเป้าหมายเพื่อตรวจจับการเปลี่ยนแปลงพฤติกรรมของเครื่องจักรตั้งแต่เนิ่นๆ แทนการวิเคราะห์เชิงลึก\u003c\/p\u003e\n\u003ch3\u003eหมายเหตุการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eแปลงสัญญาณโพรบใกล้เคียงเป็นเอาต์พุต 4 ถึง 20 mA\u003c\/li\u003e\n\u003cli\u003eออกแบบมาสำหรับแอปพลิเคชันการติดตามการสั่นสะเทือนอย่างต่อเนื่อง\u003c\/li\u003e\n\u003cli\u003eรองรับระบบโพรบใกล้เคียง 3300 NSv\u003c\/li\u003e\n\u003cli\u003eการทำงานแบบ 2 สายที่ใช้พลังงานจากวงจรช่วยให้ออกแบบสายไฟง่ายขึ้น\u003c\/li\u003e\n\u003cli\u003eการติดตั้งแบบไฮบริดราง DIN + สกรูสำหรับการติดตั้งที่ยืดหยุ่น\u003c\/li\u003e\n\u003cli\u003eอิเล็กทรอนิกส์ปรับสัญญาณในตัว\u003c\/li\u003e\n\u003cli\u003eให้การเข้าถึงสัญญาณการสั่นสะเทือนดิบผ่าน PROX OUT\u003c\/li\u003e\n\u003cli\u003eการปรับเทียบภายนอก (ศูนย์\/ช่วง)\u003c\/li\u003e\n\u003cli\u003eการตรวจจับข้อผิดพลาดพร้อมสัญญาณลดลงของเอาต์พุต\u003c\/li\u003e\n\u003cli\u003eตัวเรือนอุตสาหกรรมขนาดกะทัดรัดแบบหุ้ม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eสถานที่ที่วิศวกรมักใช้\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eบริบทของอุปกรณ์\u003c\/th\u003e\n\u003cth\u003eเหตุผลที่ใช้\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eสกิดคอมเพรสเซอร์\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบการสั่นสะเทือนเพลาที่มั่นคง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eปั๊มอุตสาหกรรม\u003c\/td\u003e\n\u003ctd\u003eการตรวจจับความไม่สมดุลหรือการสึกหรอล่วงหน้า\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระบบพัดลม\u003c\/td\u003e\n\u003ctd\u003eการติดตามสภาพอย่างต่อเนื่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเครื่องจักรบรรจุ OEM\u003c\/td\u003e\n\u003ctd\u003eวงจรป้อนกลับการสั่นสะเทือนในตัว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุปกรณ์หมุนเสริม\u003c\/td\u003e\n\u003ctd\u003eการป้องกันพื้นฐานสำหรับอินพุตไปยัง PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแผงรีโทรฟิต\u003c\/td\u003e\n\u003ctd\u003eการรวมเข้ากับตู้ที่มีอยู่ได้ง่าย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการแยกรายการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eองค์ประกอบ\u003c\/th\u003e\n\u003cth\u003eความหมายของรหัส\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e-04 = 0-4 mils pp (0-100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e-50 = 5.0 เมตร (16.4 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e-03 = คลิป DIN และสกรู\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003ctd\u003e-00 = ไม่จำเป็น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางกลและขนาด\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eรายการ\u003c\/th\u003e\n\u003cth\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n\u003ctd\u003e990-04-50-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณการสั่นสะเทือน 2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสภาพ\u003c\/td\u003e\n\u003ctd\u003eใหม่และแท้ในบรรจุภัณฑ์โรงงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการรับประกันจากโรงงาน\u003c\/td\u003e\n\u003ctd\u003e12 เดือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003e9.5 มม. (0.375 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003e53.3 มม. x 73.9 มม. x 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความสูงตัวเครื่อง (ไม่มีคลิป DIN)\u003c\/td\u003e\n\u003ctd\u003e42.6 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eระยะห่างรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e63.5 มม. x 69.9 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเส้นผ่านศูนย์กลางรูติดตั้ง\u003c\/td\u003e\n\u003ctd\u003e5.8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักสุทธิ\u003c\/td\u003e\n\u003ctd\u003e0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักรวมระบบ\u003c\/td\u003e\n\u003ctd\u003e0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eภาพรวมอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eอินเทอร์เฟซ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตตัวตรวจจับ\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อกับตัวตรวจจับระยะใกล้ 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุต 4-20 mA\u003c\/td\u003e\n\u003ctd\u003eสัญญาณการสั่นสะเทือนไปยังระบบควบคุม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอินพุตพลังงาน\u003c\/td\u003e\n\u003ctd\u003eแหล่งจ่ายไฟแบบวงจรลูป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eสัญญาณวินิจฉัยการสั่นสะเทือนดิบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eการอ้างอิงทางไฟฟ้า\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกการติดตั้ง (มุมมองจากประสบการณ์ภาคสนาม)\u003c\/h3\u003e\n\u003cp\u003eในการติดตั้งในตู้ รุ่นนี้มักติดตั้งบนราง DIN ก่อน แล้วจึงยึดด้วยสกรูเมื่อคาดว่าจะมีการสั่นสะเทือนหรือแรงดึงของสายไฟ เพื่อลดการคลายตัวในระยะยาวในสภาพแวดล้อมที่มีการสั่นสะเทือนสูง เช่น ตู้เครื่องอัดอากาศ\u003c\/p\u003e\n\u003cp\u003eการจัดสายตัวตรวจจับสำคัญสำหรับรุ่นนี้ วิศวกรมักแยกสายสัญญาณระดับต่ำออกจากสายไฟมอเตอร์เพื่อหลีกเลี่ยงการรบกวน โดยเฉพาะในแผนผังการเดินสาย 5 เมตรที่มักมัดรวมกัน\u003c\/p\u003e\n\u003cp\u003eในระหว่างการติดตั้ง ควรตรวจสอบช่องว่างของตัวตรวจจับก่อนจ่ายไฟให้วงจร เมื่อเปิดใช้งานแล้ว ให้รอสัญญาณเสถียรภายใต้สภาพเครื่องจักรที่คงที่ก่อนนำไปใช้ในตรรกะสัญญาณเตือน\u003c\/p\u003e\n\u003cp\u003eจุด PROX OUT มีประโยชน์ในระหว่างการแก้ไขปัญหา แต่ในทางปฏิบัติมักใช้เฉพาะในช่วงเริ่มต้นหรือช่วงบำรุงรักษาเท่านั้น ไม่ใช่การใช้งานต่อเนื่อง\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณนี้เหมาะสำหรับเครื่องจักรสกิดขนาดกะทัดรัดหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ มักเลือกใช้กับอุปกรณ์หมุนที่ติดตั้งบนสกิด OEM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อได้เปรียบหลักของความยาวระบบ 5.0 ม. คืออะไร?\u003c\/strong\u003e\u003cbr\u003eเหมาะกับการจัดวางสายตัวตรวจจับระยะกลางส่วนใหญ่โดยไม่มีความซับซ้อนของสัญญาณ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eติดตั้งได้เฉพาะบนราง DIN หรือไม่?\u003c\/strong\u003e\u003cbr\u003eรองรับการติดตั้งบนราง DIN แต่ก็อนุญาตให้เสริมด้วยสกรูได้ด้วย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eให้การเข้าถึงสัญญาณการสั่นสะเทือนดิบหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ PROX OUT ให้สัญญาณวินิจฉัยสำหรับเครื่องมือภายนอก\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eออกแบบมาสำหรับระบบควบคุมประเภทใด?\u003c\/strong\u003e\u003cbr\u003eออกแบบมาเพื่อการรวมเข้ากับอินพุตแอนะล็อกของ PLC และ DCS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eนี่คือระบบวินิจฉัยหรือเครื่องส่งสัญญาณ?\u003c\/strong\u003e\u003cbr\u003eเป็นเครื่องส่งสัญญาณแบบง่าย ไม่ใช่ระบบวิเคราะห์การสั่นสะเทือนเต็มรูปแบบ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นถ้าตัวตรวจจับล้มเหลว?\u003c\/strong\u003e\u003cbr\u003eเอาต์พุตจะลดลงสู่สถานะข้อผิดพลาดกระแสต่ำเพื่อแสดงว่าไม่ปกติ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเหมาะสำหรับเครื่องอัดอากาศและปั๊มหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ ใช้กันอย่างแพร่หลายกับเครื่องอัดอากาศ ปั๊ม และพัดลม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอะไรที่ทำให้รุ่นนี้แตกต่างในการติดตั้ง?\u003c\/strong\u003e\u003cbr\u003eใช้การติดตั้งแบบรวมคลิป DIN และสกรู\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eใช้สำหรับการวินิจฉัยการสั่นสะเทือนอย่างละเอียดหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ ใช้สำหรับการตรวจสอบระดับแนวโน้มเท่านั้น\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666613432683,"sku":"990-04-50-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-03-00-990-vibration-transmitter-3phzlju5ibc_8ef2edb9-f39d-43ca-9b7b-48c54e693a39.jpg?v=1765444172"},{"product_id":"bently-nevada-991-25-70-03-05-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-25-70-03-05 991 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e991-25-70-03-05\u003c\/strong\u003e 991 Thrust Transmitter เป็นตัวส่งสัญญาณการเคลื่อนที่ตามแกนแบบ 2 สาย ใช้พลังงานจากลูป ออกแบบมาสำหรับผู้ผลิตอุปกรณ์ต้นแบบ (OEM) ของเครื่องอัดอากาศแบบแรงเหวี่ยง ปั๊มขนาดเล็ก มอเตอร์ หรือพัดลม อุปกรณ์รับสัญญาณอินพุตเดียวจากโพรบใกล้เคียง 3300 NSv และสายต่อขยายที่ตรงกัน ปรับสัญญาณเป็นเอาต์พุตกระแส 4 ถึง 20 mA ตามมาตรฐานอุตสาหกรรม ซึ่งสัดส่วนกับตำแหน่งแกนเพลาขับ (แรงดัน) เพื่อการรวมเข้ากับระบบควบคุมเครื่องจักรโดยตรงสำหรับการป้องกันและแจ้งเตือน\u003c\/p\u003e\n\u003cp\u003eตัวส่งสัญญาณรวมฟังก์ชันของเซ็นเซอร์ Proximitor ไว้ในหน่วยเดียว ช่วยลดความจำเป็นในการใช้เซ็นเซอร์อิสระภายนอก ขั้ว PROX OUT และ COM ที่ไม่แยกวงจร พร้อมขั้วต่อ BNC แบบโคแอกเชียล ให้สัญญาณแรงสั่นสะเทือนและแรงดันช่องว่างแบบไดนามิกสำหรับการวินิจฉัยเครื่องจักร ตัวส่งสัญญาณมีโครงสร้างเต็มไปด้วยวัสดุป้องกัน ช่วยให้ทำงานได้อย่างเสถียรในสภาพแวดล้อมที่มีความชื้นสูงถึง 100 เปอร์เซ็นต์ที่มีการควบแน่น\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการออกแบบแบบบูรณาการรวมตัวส่งสัญญาณและเซ็นเซอร์ Proximitor ไว้ในหน่วยเดียว\u003c\/li\u003e\n\u003cli\u003eการกำหนดค่าแบบ 2 สาย ใช้พลังงานจากลูป ให้สัญญาณ 4 ถึง 20 mAdc ที่สัดส่วนกับการเคลื่อนที่ตามแกนเต็มสเกล\u003c\/li\u003e\n\u003cli\u003eขั้ว PROX OUT, COM ที่ไม่แยกวงจร และขั้วต่อ BNC ให้สัญญาณแรงสั่นสะเทือนและแรงดันช่องว่างแบบไดนามิกสำหรับการวินิจฉัยภาคสนาม\u003c\/li\u003e\n\u003cli\u003eตัวปรับศูนย์และสเกลภายนอกที่ไม่รบกวนกันใต้ฉลากช่วยให้ปรับแต่งลูปได้ง่าย\u003c\/li\u003e\n\u003cli\u003eขา Test Input ช่วยให้ตรวจสอบสัญญาณลูปเอาต์พุตได้อย่างรวดเร็วโดยใช้แหล่งจ่ายไฟ DC แบบปรับค่าได้\u003c\/li\u003e\n\u003cli\u003eวงจร Power-up Inhibit ช่วยขจัดข้อผิดพลาดของสัญญาณที่เกิดจากแรงดันไฟฟ้าชั่วคราวในสายไฟขณะเริ่มต้นใช้งาน\u003c\/li\u003e\n\u003cli\u003eวงจร Not OK \/ Signal Defeat จะล็อกสัญญาณเอาต์พุตต่ำกว่า 3.6 mA เพื่อป้องกันสัญญาณสูงเกินหรือสัญญาณเตือนผิดพลาดที่เกิดจากข้อผิดพลาดของโพรบหรือสายเคเบิล\u003c\/li\u003e\n\u003cli\u003eตัวเรือนที่เต็มไปด้วยวัสดุป้องกันช่วยให้ใช้งานได้ในสภาพแวดล้อมที่มีความชื้นสูงและการควบแน่น 100 เปอร์เซ็นต์\u003c\/li\u003e\n\u003cli\u003eการกำหนดค่ามาตรฐานรวมคลิปราง DIN ขนาด 35 มม. และอุปกรณ์ติดตั้งบนผนัง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eเครื่องอัดอากาศแบบแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eปั๊มอุตสาหกรรมขนาดเล็ก\u003c\/li\u003e\n\u003cli\u003eมอเตอร์ไฟฟ้าอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eพัดลมระบายอากาศอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบแนวโน้มตำแหน่งแกนโรเตอร์ (แรงดัน) และการป้องกันเครื่องจักร\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003ch4\u003eการกำหนดค่ารุ่น (991-25-70-03-05)\u003c\/h4\u003e\n\u003cp\u003eตามระบบการตั้งชื่อรุ่น Bently Nevada 991 ซีรีส์ พารามิเตอร์การกำหนดค่ารุ่นเฉพาะจะถูกถอดรหัสดังนี้:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eตำแหน่งตัวเลือก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eรายการการกำหนดค่า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนดทางเทคนิค\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eAA\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eตัวเลือกเต็มสเกล\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e25-0-25 มิลส์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBB\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eตัวเลือกความยาวระบบ\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e7.0 เมตร (23.0 ฟุต)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eCC\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eตัวเลือกการติดตั้ง\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eคลิปและสกรู DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eDD\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eตัวเลือกการรับรองหน่วยงาน\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2 รวมถึงการรับรองทางทะเล ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eไฟฟ้า\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eพลังงานขาเข้า\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eต้องการ +12 ถึง +35 Vdc ที่ขั้วเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eสัญญาณเอาต์พุต\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e4 ถึง 20 mAdc การกำหนดแบบ 2 สาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eความแม่นยำลูป\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eความแม่นยำลูปโดยทั่วไป ±1.5 เปอร์เซ็นต์ในช่วงเต็มที่ระบุ (วัดจากขา TEST ถึงความต้านทานลูป 250 โอห์ม)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eความต้านทานลูปสูงสุด\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eความต้านทานลูปสูงสุด 1,000 โอห์ม ที่ 35 Vdc (รวมความต้านทานสาย) สูตร: R_LOOP = 43.5 x (V_PS - 12) โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eการจำกัดกระแส\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e23 mA โดยทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eอิมพีแดนซ์เอาต์พุตไดนามิก\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003ePROX OUT มีอิมพีแดนซ์เอาต์พุต 10 กิโลโอห์ม ปรับเทียบสำหรับโหลด 10 เมกะโอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eช่วงเชิงเส้น\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0.25 ถึง 1.65 มม. (10 ถึง 65 mils) ที่อินเทอร์เฟซ PROX OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eปัจจัยสเกลเพิ่มขึ้น\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e7.87 mV\/ไมโครเมตร (200 mV\/mil) โดยทั่วไป ±6.5 เปอร์เซ็นต์ รวมความผิดพลาดการเปลี่ยนแทนเมื่อวัดกับเป้าหมายเหล็กแบน AISI 4140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eความเสถียรของอุณหภูมิ\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eปัจจัยสเกลเพิ่มขึ้นคงที่ภายใน ±10 เปอร์เซ็นต์ของ 7.87 mV\/ไมโครเมตร (200 mV\/mil) จาก 0 องศาเซลเซียส ถึง +70 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eเส้นผ่านศูนย์กลาง 9.5 มม. (0.375 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eไดนามิกและการจับเวลา\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eดีเลย์ Not OK\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eสัญญาณเอาต์พุตลดลงต่ำกว่า 3.6 mA ภายใน 100 ไมโครวินาทีหลังเกิดเงื่อนไข Not OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eเวลาฟื้นตัว OK\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eสัญญาณเอาต์พุตกลับสู่ปกติภายใน 0.1 วินาทีหลังจากเงื่อนไข Not OK ถูกลบออก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eขีดจำกัดสิ่งแวดล้อม\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eอุณหภูมิการใช้งานเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-35 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eอุณหภูมิการเก็บเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-51 องศาเซลเซียส ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eอุณหภูมิการใช้งานโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e-52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eอุณหภูมิการเก็บโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e-52 องศาเซลเซียส ถึง +177 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eความชื้นสัมพัทธ์\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eการควบแน่น 100 เปอร์เซ็นต์ การทำงานไม่จมน้ำ (ต้องป้องกันขั้วต่อ coaxial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eเชิงกล\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eน้ำหนักเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0.43 กก. (0.9 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eน้ำหนักโดยประมาณ 0.82 กก. (1.8 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eวัสดุตัวเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eสแตนเลส AISI 303 หรือ 304 (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eวัสดุปลายโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eโพลีฟีนิลีนซัลไฟด์ (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eสายโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eสาย coaxial 75 โอห์ม ฉนวน Fluorinated Ethylene Propylene (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eความต้านทานแรงดึง\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eแรงดึงสูงสุด 222 N (50 lbf) ระหว่างตัวโพรบกับสายโพรบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eการเชื่อมต่อ \/ อินเทอร์เฟซ\u003c\/h3\u003e\n\u003ch4\u003eบล็อกขั้วต่อและขั้วต่อของเครื่องส่งสัญญาณ\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eบล็อกขั้วต่อ \/ ขั้วต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eชื่อขั้วต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eE1\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePWR (พลังงาน)\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eลูป 4-20 mA ขั้วบวกป้อนพลังงาน (+17 ถึง +35 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eE2\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eCOM (ร่วม)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eลูป 4-20 mA ขั้วลบ \/ การคืนค่าร่วม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eE3\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePROX OUT\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eเอาต์พุตสัญญาณไดนามิกที่ไม่แยกวงจร (สายคู่บิดสูงสุด 3 เมตร)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eE4\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eสัญญาณไดนามิกอ้างอิงร่วม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eJ2\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003ePROX OUT (BNC)\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eเอาต์พุต BNC coaxial แบบไดนามิกที่ไม่แยกวงจรสำหรับอุปกรณ์วินิจฉัยแบบพกพา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eJ3\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eขั้วต่อโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eขั้วต่อ coaxial ClickLoc สำหรับเชื่อมต่อสายต่อขยายโพรบระยะใกล้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการเลือกสายเคเบิล: สำหรับวงจรกระแส 4 ถึง 20 mA ระหว่างตัวส่งสัญญาณและตัวรับ (PLC\/DCS) ให้ใช้สายเคเบิลคู่บิดมีชิลด์ ขนาด 1.0 มม.² (18 AWG) (หมายเลขชิ้นส่วน 02173006) ความยาวสูงสุดที่อนุญาตคือ 13 กม. (8 ไมล์).\u003c\/li\u003e\n\u003cli\u003eการกราวด์และการป้องกัน: ชิลด์สายเคเบิลต้องต่อเข้ากับกราวด์จุดเดียวที่ปลายรับ ชิลด์ที่ปลายตัวส่งสัญญาณต้องถูกฉนวนและแยกจากตัวเรือนตัวส่งสัญญาณและกราวด์ท้องถิ่นเพื่อป้องกันการเกิดลูปกราวด์.\u003c\/li\u003e\n\u003cli\u003eการแยกอินเทอร์เฟซ PROX OUT: ตัวเชื่อมต่อโคแอกเชียลและขั้ว PROX OUT ไม่ได้แยกจากวงจรกระแส 4 ถึง 20 mA การเชื่อมต่ออุปกรณ์ทดสอบที่มีกราวด์และใช้ไฟฟ้ากระแสสลับ (เช่น ออสซิลโลสโคปหรือเครื่องวิเคราะห์) โดยตรงกับ PROX OUT อาจทำให้วงจรลัดวงจรหรือเกิดกระแสกราวด์ ส่งผลให้เกิดสัญญาณเตือนแรงดันเท็จหรือการตัดวงจร ใช้ตัวปรับทดสอบ 122115-01 สำหรับอุปกรณ์ที่ใช้ไฟฟ้ากระแสสลับ.\u003c\/li\u003e\n\u003cli\u003eลักษณะเฟสสัญญาณ: เฟสของสัญญาณ PROX OUT แบบไดนามิกจะถูกกลับด้านเมื่อเทียบกับเซ็นเซอร์ Bently Nevada Proximitor มาตรฐาน ตัวปรับทดสอบ 122115-01 จะกลับสัญญาณเพื่อคืนค่าขั้วมาตรฐานสำหรับอุปกรณ์วินิจฉัยภายนอก.\u003c\/li\u003e\n\u003cli\u003eข้อจำกัดการยึดเกลียว: ตรวจสอบการยึดเกลียวอย่างถูกต้องเมื่อทำการติดตั้งโพรบ (เช่น การยึดเกลียวสูงสุด 0.375 นิ้วสำหรับเกลียว 1\/4-28 และสูงสุด 0.563 นิ้วสำหรับเกลียว 3\/8-24) การเกิน 1.5 เท่าของเส้นผ่านศูนย์กลางเกลียวปกติอาจทำให้เกิดการติดขัดภายในและทำลายตัวเรือน.\u003c\/li\u003e\n\u003cli\u003eการป้องกันความชื้น: แม้ว่าตัวเรือนตัวส่งสัญญาณจะได้รับการจัดอันดับให้ทนความชื้นสัมพัทธ์ที่มีการควบแน่น 100 เปอร์เซ็นต์ แต่ต้องไม่จมอยู่ในน้ำ ตัวเชื่อมต่อโคแอกเชียลภายนอกทั้งหมดต้องถูกปิดผนึกโดยใช้ตัวป้องกันตัวเชื่อมต่อ ClickLoc (เช่นปลอกฟลูออโรซิลิโคน) เพื่อป้องกันการซึมของความชื้นหรือน้ำมัน.\u003c\/li\u003e\n\u003cli\u003eข้อจำกัดความต้านทานวงจร: ตรวจสอบให้แน่ใจว่าความต้านทานวงจรรวม R_LOOP ไม่เกินค่าที่กำหนดโดยแรงดันไฟฟ้าแหล่งจ่ายไฟ หากความต้านทานวงจรสูงเกินไป ตัวส่งสัญญาณจะไม่สามารถขับกระแสเอาต์พุต 20 mA เต็มที่ภายใต้เงื่อนไขการเคลื่อนที่สูงสุดได้.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและใบรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFCC: เป็นไปตามกฎ FCC ส่วนที่ 15.\u003c\/li\u003e\n\u003cli\u003eATEX: เป็นไปตามคำสั่ง ATEX 2014\/34\/EU.\u003c\/li\u003e\n\u003cli\u003eRoHS: เป็นไปตามคำสั่ง RoHS 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003eChina RoHS: ระยะเวลาการใช้งานที่เป็นมิตรกับสิ่งแวดล้อม (EFUP) ได้รับการจัดอันดับไว้ที่ 15 ปี ตาม SJ\/T 11364-2014.\u003c\/li\u003e\n\u003cli\u003eทางทะเล: ได้รับการอนุมัติภายใต้กฎเรือเหล็ก ABS 2009.\u003c\/li\u003e\n\u003cli\u003eการอนุมัติความปลอดภัยของแคนาดาและสหรัฐอเมริกา (cNRTLus):\n\u003cul\u003e\n\u003cli\u003eคลาส I, แผนก 2, กลุ่ม A, B, C, D; T5 ที่ Ta = +85 องศาเซลเซียส, ประเภท 4 (เมื่อทำการติดตั้งตามแบบร่าง 128838).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eใบรับรองพื้นที่อันตราย (ATEX\/IECEx):\n\u003cul\u003e\n\u003cli\u003eII 1G Ex ia IIC T4 Ga, T4 ที่ Ta = -30 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/li\u003e\n\u003cli\u003eII 3G Ex ec IIC T4 Gc, T4 ที่ Ta = -30 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eพารามิเตอร์ความปลอดภัยภายใน (โซน 0\/1):\n\u003cul\u003e\n\u003cli\u003eขั้วต่อ E1-E2 (พาวเวอร์\/วงจร): U_i = 28 V, I_i = 120 mA, P_i = 0.84 W, C_i = 20 nF, L_i = 10 ไมโครเฮนรี\u003c\/li\u003e\n\u003cli\u003eขั้วต่อ E3-E4 และ J2 (เอาต์พุต Prox): U_o = 28 V, I_o = 6 mA, P_o = 0.17 W, C_o = 80 nF, L_o = 1 H.\u003c\/li\u003e\n\u003cli\u003eJ3 อินเทอร์เฟซ (การเชื่อมต่อโพรบ): U_o = 28 V, I_o = 100 mA, P_o = 0.8 W, C_o = 27.3 nF, L_o = 5.3 mH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eQ1: ข้อจำกัดหลักด้านตรรกะของเครื่องส่งสัญญาณ 991 เมื่อเทียบกับระบบตรวจสอบมาตรฐานเช่นซีรีส์ 3500 คืออะไร?\u003c\/h4\u003e\n\u003cp\u003eA1: เครื่องส่งสัญญาณ 991 ไม่มีตรรกะการตรวจสอบที่ซับซ้อน เช่น การปิดช่อง Timed OK, การบายพาสอันตราย หรือ Trip Multiply กระแสไฟฟ้าขาออกแบบแอนะล็อก 4-20 mA ยังป้องกันการรวมซอฟต์แวร์โดยตรงกับแพลตฟอร์มการจัดการสินทรัพย์โรงงาน เช่น System 1 หรือ Rule Paks\u003c\/p\u003e\n\u003ch4\u003eQ2: ช่วงการวัดที่สอบเทียบแล้วสำหรับการกำหนดค่า 991-25-70-03-05 คืออะไร?\u003c\/h4\u003e\n\u003cp\u003eA2: ตัวเลือกช่วง \"25\" หมายถึงช่วงการวัดเชิงเส้นเต็มสเกล 25-0-25 มิลของการเลื่อนแกนที่แมปกับวงจรกระแส 4 ถึง 20 mA\u003c\/p\u003e\n\u003ch4\u003eQ3: ความยาวระบบรวมที่ต้องการสำหรับการกำหนดค่านี้คือเท่าใด?\u003c\/h4\u003e\n\u003cp\u003eA3: ตัวเลือกความยาวระบบ \"70\" กำหนดให้ต้องใช้เครื่องส่งสัญญาณร่วมกับระบบโพรบและสายต่อขยาย 3300 NSv ความยาวรวม 7.0 เมตร (23.0 ฟุต) เท่านั้น การผสมส่วนประกอบของระบบความยาว 5.0 เมตรจะทำให้การสอบเทียบและความเป็นเส้นตรงลดลง\u003c\/p\u003e\n\u003ch4\u003eQ4: จะเกิดอะไรขึ้นหากเชื่อมต่อออสซิลโลสโคปที่ใช้ไฟ AC โดยตรงกับแจ็ค BNC ของ PROX OUT?\u003c\/h4\u003e\n\u003cp\u003eA4: เนื่องจากกราวด์ของขั้ว PROX OUT ใช้ร่วมกับขั้วกลับของวงจรกระแส 4-20 mA (COM) การเชื่อมต่อเครื่องมือที่ใช้ไฟ AC ที่มีกราวด์ร่วมกันอาจทำให้เกิดวงจรกราวด์ซ้ำซ้อนหรือลัดวงจร ส่งผลให้เกิดสัญญาณเตือนแรงดันเท็จหรือเครื่องจักรหยุดทำงานในระบบควบคุม\u003c\/p\u003e\n\u003ch4\u003eQ5: จะเชื่อมต่อเครื่องมือวินิจฉัยที่ใช้ไฟ AC ภายนอกอย่างปลอดภัยได้อย่างไร?\u003c\/h4\u003e\n\u003cp\u003eA5: ใช้อะแดปเตอร์ทดสอบ Bently Nevada 122115-01 อะแดปเตอร์นี้ให้การแยกวงจรระหว่างวงจรส่งสัญญาณและเครื่องมือทดสอบเพื่อกำจัดวงจรกราวด์ซ้ำซ้อน พร้อมทั้งกลับสัญญาณ 180 องศาให้ตรงกับขั้วของเครื่องมือมาตรฐาน\u003c\/p\u003e\n\u003ch4\u003eQ6: เวลาตอบสนองแบบไดนามิกของวงจรกระแส 991 ในระหว่างข้อผิดพลาดของเซ็นเซอร์คือเท่าใด?\u003c\/h4\u003e\n\u003cp\u003eA6: หากการเปิดวงจรหรือวงจรลัดวงจรของโพรบหรือสายเคเบิลทำให้เกิดสถานะ Not OK กระแสไฟฟ้าขาออกจะลดลงต่ำกว่า 3.6 mA ภายใน 100 ไมโครวินาที เมื่อแก้ไขข้อผิดพลาดแล้ว วงจรจะกลับสู่สถานะ OK ภายใน 0.1 วินาที\u003c\/p\u003e\n\u003ch4\u003eQ7: แรงดันไฟฟ้าแหล่งจ่ายส่งผลต่อความสามารถความต้านทานลูปของตัวส่งสัญญาณอย่างไร?\u003c\/h4\u003e\n\u003cp\u003eA7: ตัวส่งสัญญาณต้องการแรงดันไฟฟ้าระหว่าง +12 Vdc ถึง +35 Vdc ที่ขั้วของมัน ความต้านทานลูปสูงสุดที่อนุญาต (รวมสายไฟและอุปกรณ์กั้นความปลอดภัย) ถูกกำหนดโดยสูตร: R_LOOP = 43.5 x (V_PS - 12) โอห์ม แรงดันไฟฟ้าไม่เพียงพอหรือความต้านทานสูงจะจำกัดกระแสเอาต์พุตสูงสุดให้น้อยกว่า 20 mA\u003c\/p\u003e\n\u003ch4\u003eQ8: ขา Test Input บนตัวส่งสัญญาณมีหน้าที่อะไร?\u003c\/h4\u003e\n\u003cp\u003eA8: ขา Test Input อนุญาตให้ช่างเทคนิคใช้แหล่งแรงดันไฟฟ้ากระแสตรงแปรผันภายนอกเพื่อจำลองการเปลี่ยนแปลงช่องว่างของโพรบ ซึ่งช่วยให้สามารถตรวจสอบลูปและสัญญาณเตือนได้ในระบบควบคุมโดยไม่ต้องถอดหรือปรับโพรบใกล้ชิดทางกายภาพ\u003c\/p\u003e\n\u003ch4\u003eQ9: โพเทนชิโอมิเตอร์ Zero และ Span มีผลกระทบต่อกันในระหว่างการปรับเทียบหรือไม่?\u003c\/h4\u003e\n\u003cp\u003eA9: ไม่ ตัวส่งสัญญาณใช้โพเทนชิโอมิเตอร์ที่ไม่ส่งผลกระทบซึ่งกันและกัน การปรับตำแหน่งศูนย์จะไม่เปลี่ยนความชันของสแปน และการปรับสแปนจะไม่เลื่อนตำแหน่งศูนย์ ทำให้กระบวนการปรับเทียบง่ายขึ้น\u003c\/p\u003e\n\u003ch4\u003eQ10: ระยะทางสูงสุดที่อนุญาตสำหรับสายลูปเอาต์พุตคือเท่าใด?\u003c\/h4\u003e\n\u003cp\u003eA10: เมื่อใช้สายคู่บิดมีชีลด์ขนาด 1.0 มม.² (18 AWG) ที่แนะนำและแหล่งจ่ายไฟ 35 Vdc สัญญาณลูปกระแสสามารถส่งได้ไกลสูงสุดถึง 13 กม. (8 ไมล์)\u003c\/p\u003e\n\u003ch4\u003eQ11: รุ่นนี้สามารถติดตั้งในสถานที่อุตสาหกรรมที่เป็นอันตรายได้หรือไม่?\u003c\/h4\u003e\n\u003cp\u003eA11: ใช่ ตัวเลือกการอนุมัติหน่วยงาน \"05\" ให้ชุดการรับรองหลายหน่วยงาน อุปกรณ์สามารถติดตั้งในสภาพแวดล้อม Class I, Division 2 หรือใช้เป็นอุปกรณ์ปลอดภัยโดยเนื้อแท้ (Ex ia IIC T4 Ga) ในโซน 0\/1 เมื่อเดินสายผ่านอุปกรณ์กั้นความปลอดภัยที่ได้รับอนุมัติ\u003c\/p\u003e\n\u003ch4\u003eQ12: ทำไมต้องจับคู่ตัวส่งสัญญาณ 991 กับโพรบ 3300 NSv แทนโพรบขนาด 8 มม. ทั่วไป?\u003c\/h4\u003e\n\u003cp\u003eA12: วงจรปรับสภาพภายในของตัวส่งสัญญาณ 991 ถูกปรับเทียบสำหรับคุณสมบัติทางไฟฟ้าและทางกายภาพของโพรบ 3300 NSv ซึ่งออกแบบมาสำหรับช่องว่างที่แคบและรูเจาะลึกขนาดเล็ก การเชื่อมต่อโพรบขนาด 8 มม. จะทำให้เกิดข้อผิดพลาดของสเกลแฟกเตอร์อย่างรุนแรง\u003c\/p\u003e\n\u003ch4\u003eQ13: ต้องมีการป้องกันอะไรสำหรับการเชื่อมต่อโคแอกเชียลในสภาพแวดล้อมที่เปียกชื้น?\u003c\/h4\u003e\n\u003cp\u003eA13: แม้ว่าตัวส่งสัญญาณจะถูกเคลือบอย่างเต็มที่เพื่อป้องกันความชื้นที่ควบแน่น 100 เปอร์เซ็นต์ แต่ขั้วต่อ ClickLoc แบบโคแอกเชียลระหว่างโพรบและสายต่อขยายอาจเกิดการลดทอนสัญญาณหากสัมผัสกับความชื้นหรือน้ำมัน จึงต้องปกป้องด้วยตัวป้องกันขั้วต่อฟลูออโรซิลิโคน\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619691371,"sku":"991-25-70-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-70-03-05-thrust-transmitter-igpun1n1wzm_542b5d48-f5db-4c44-848a-9fb221ea0051.jpg?v=1765444241"},{"product_id":"bently-nevada-990-10-xx-01-05-mod-165353-07-vibration-transmitter","title":"เครื่องส่งสัญญาณการสั่นสะเทือน Bently Nevada 990-10-XX-01-05 MOD:165353-07","description":"\u003cp style=\"color: #2d3748;\"\u003eBently Nevada 990-10-XX-01-05 MOD:165353-07 เป็นเครื่องส่งสัญญาณการสั่นสะเทือนแบบ \u003cstrong\u003eใช้สายไฟสองเส้นจ่ายพลังงาน\u003c\/strong\u003e ที่ทนทาน ออกแบบมาเพื่อปกป้องเครื่องจักรหมุนในอุตสาหกรรมอย่างต่อเนื่อง อุปกรณ์ที่มีความน่าเชื่อถือสูงนี้ทำงานร่วมกับ \u003cstrong\u003eระบบโพรบใกล้เคียง\u003c\/strong\u003e เพื่อวัดการสั่นสะเทือนของตัวเครื่องหรือเพลาที่ไม่สัมผัสโดยตรง แปลงการเคลื่อนที่ทางกายภาพเป็นสัญญาณกระแสอนาล็อกมาตรฐานอุตสาหกรรม \u003cstrong\u003e4-20mA\u003c\/strong\u003e ออกแบบมาโดยเฉพาะสำหรับทรัพย์สินสำคัญ เช่น เครื่องอัดอากาศแรงเหวี่ยง ปั๊มขนาดเล็ก มอเตอร์ และพัดลม สามารถเชื่อมต่อโดยตรงกับโปรแกรมเมเบิลลอจิกคอนโทรลเลอร์ (PLC) ระบบควบคุมแบบกระจาย (DCS) หรือเครือข่ายการควบคุมและเก็บข้อมูล (SCADA) โดยไม่ต้องใช้ระบบมอนิเตอร์แยกต่างหาก\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eคุณสมบัติหลัก\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eการออกแบบ Proximitor แบบบูรณาการ:\u003c\/strong\u003e รวมการปรับสภาพเซ็นเซอร์และวงจรเครื่องส่งสัญญาณกระแสในวงจรเดียวในแพ็กเกจขนาดกะทัดรัดสำหรับติดตั้งบนราง DIN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eเอาต์พุต 4-20mA ต่อเนื่อง:\u003c\/strong\u003e ส่งกระแสอนาล็อกแบบสัดส่วนสำหรับการเชื่อมต่อโดยตรงกับ SCADA, DCS หรือ PLC เพื่อการติดตามแนวโน้ม การสร้างสัญญาณเตือน และตรรกะการปิดเครื่อง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตามการเคลื่อนที่แบบไม่สัมผัส:\u003c\/strong\u003e ใช้หลักการกระแสไหลวนเพื่อตรวจสอบช่องว่างของแบริ่งฟิล์มของเหลวขนาดเล็กด้วยความแม่นยำสูง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eได้รับการรับรองสำหรับพื้นที่อันตราย:\u003c\/strong\u003e มีการอนุมัติจากหลายหน่วยงาน (ระบุด้วยตัวเลือก -05) สำหรับการใช้งานในสภาพแวดล้อมอุตสาหกรรมที่มีความเสี่ยงสูง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเข้าถึงสัญญาณแบบไดนามิก:\u003c\/strong\u003e มีจุดต่อ BNC เฉพาะหรือทางเลือกการเดินสายคู่ขนานสำหรับการวิเคราะห์ภาคสนามโดยใช้เครื่องวิเคราะห์การสั่นสะเทือนแบบพกพา\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOD:165353-07 การปรับแต่ง:\u003c\/strong\u003e การกำหนดค่าที่ปรับแต่งโดยโรงงานสำหรับตัวกรองความถี่ OEM เฉพาะ การปรับแต่งสเกลแฟกเตอร์เฉพาะ หรือคุณสมบัติการลดแรงสั่นสะเทือนของฮาร์ดแวร์เฉพาะ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eการใช้งานอุตสาหกรรมหนัก\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eเครื่องอัดอากาศแบบแรงเหวี่ยงและแบบแกนในโรงงานปิโตรเคมี\u003c\/li\u003e\n\u003cli\u003eมอเตอร์ไฟฟ้าความเร็วสูงและพัดลมหอทำความเย็นอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eปั๊มน้ำป้อนหม้อไอน้ำหลายขั้นตอนและปั๊มของเหลวในกระบวนการ\u003c\/li\u003e\n\u003cli\u003eกังหันแก๊สอุตสาหกรรมและชุดเครื่องกำเนิดไฟฟ้ากังหันไอน้ำขนาดเล็ก\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; min-width: 500px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eค่าข้อมูลจำเพาะ\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eชุดผลิตภัณฑ์\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eเครื่องส่งสัญญาณการสั่นสะเทือนรุ่น 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eรหัสช่วงเต็มสเกล (-10)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eโดยปกติจะตั้งค่าไว้ที่ 0-10 มิลลิเมตรพีคทูพีค หรือการเคลื่อนที่ 0-250 ไมโครเมตรพีคทูพีค\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eตัวเลือกความยาวระบบ (-XX)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eกำหนดโดยความยาวสายโพรบ\/สายต่อที่จับคู่ (โดยทั่วไประบบปรับจูนที่ 5.0 เมตร หรือ 9.0 เมตร)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eตัวเลือกการติดตั้ง (-01)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eติดตั้งบนราง DIN ขนาดมาตรฐาน 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eรหัสการอนุมัติหน่วยงาน (-05)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eได้รับการรับรองหลายมาตรฐานในพื้นที่อันตราย (ATEX \/ IECEx \/ CSA \/ Class I Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eรหัสการดัดแปลง\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eMOD:165353-07 (การตอบสนองตัวกรองเฉพาะ \/ การปรับฮาร์ดแวร์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเภทสัญญาณเอาต์พุต\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eลูปกระแส DC แบบเชิงเส้น 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eข้อกำหนดแหล่งจ่ายไฟ\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eใช้พลังงานจากลูป, แรงดันไฟฟ้าอินพุตปกติ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e0.45 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e15.2 ซม. x 12.7 ซม. x 7.6 ซม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eการเชื่อมต่อขั้วต่อภาคสนาม\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; min-width: 500px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eป้ายขั้วต่อ\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eฟังก์ชันสัญญาณ \/ ลูป\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2b6cb0;\"\u003ePROBE\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eขั้วต่อโคแอกเชียลสำหรับโพรบ Bently Nevada Eddy Current Proximity \/ สายต่อขยาย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2b6cb0;\"\u003eCOM\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eขั้วกราวด์อ้างอิงระบบ \/ กราวด์ลูป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2b6cb0;\"\u003eSIG \/ +4-20mA\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eขั้วเชื่อมต่อสายลูปกระแสบวกกลับไปยังโมดูลอินพุตแอนะล็อก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; color: #2b6cb0;\"\u003eBUF \/ OUT\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eสัญญาณแรงดันดิบแบบบัฟเฟอร์สำหรับเชื่อมต่อกับเครื่องบันทึกข้อมูลและเครื่องวิเคราะห์ FFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eแนวทางการติดตั้งและการเริ่มใช้งาน\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eคำเตือนสำคัญในภาคสนาม:\u003c\/strong\u003e\n\u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eแยกและล็อกแหล่งจ่ายไฟทั้งหมดที่จ่ายให้กับตู้เครื่องมือวงจรก่อนเปิดหรือเปลี่ยนแปลงการต่อสาย หากไม่ตัดไฟวงจรอย่างสมบูรณ์ในบรรยากาศอันตรายที่กำหนด อาจทำให้ระบบความปลอดภัยภายในเสียหายและเสี่ยงต่อการจุดระเบิด\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003e\n\u003cstrong\u003eการติดตั้งบนราง DIN:\u003c\/strong\u003e ติดตั้งอย่างมั่นคงบนราง DIN แบบสมมาตรขนาด 35 มม. ภายในตู้ควบคุมอุตสาหกรรมที่สะอาดและปลอดฝุ่น ให้แน่ใจว่าทิศทางการติดตั้งมีช่องว่างระบายอากาศแบบพาสซีฟระหว่างตัวส่งสัญญาณที่อยู่ติดกัน\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003e\n\u003cstrong\u003eการเชื่อมต่อโพรบโคแอกเชียล:\u003c\/strong\u003e เชื่อมต่อขั้วต่อสายต่อขยายที่สะอาดและแห้งจากโพรบเข้ากับฮับตัวรับส่งหลัก ใช้เทปซิลิโคนแบบผสมตัวเองพันรอบปลอกเชื่อมต่อโคแอกเชียลอย่างสมบูรณ์เพื่อป้องกันความชื้นหรือการลัดวงจรกราวด์ไฟฟ้า\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003e\n\u003cstrong\u003e\u003cstrong\u003eการตั้งค่าลูปสายคู่บิด: \u003c\/strong\u003e\u003c\/strong\u003eเดินสายขั้วลูปกระแส 4-20mA โดยใช้สายคู่บิดมีชิลด์ เชื่อมต่อชิลด์สายที่ปลายกราวด์ของแร็คเครื่องมือเท่านั้นเพื่อป้องกันการเกิดลูปกราวด์ภาคสนามที่อาจทำให้เกิดสัญญาณรบกวนในข้อมูลการสั่นสะเทือน\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003e\n\u003cstrong\u003e\u003cstrong\u003eการปรับเทียบแรงดันช่องว่าง: \u003c\/strong\u003e\u003c\/strong\u003eตรวจสอบช่องว่างทางกลเริ่มต้นโดยใช้มัลติมิเตอร์ดิจิทัลที่ขั้ว BUF\/COM ให้แน่ใจว่าแรงดันช่องว่าง DC อยู่ในช่วงเชิงเส้นก่อนเริ่มใช้งานเครื่องจักรเพื่อให้ได้ขอบเขตการตอบสนองแบบไดนามิกที่เหมาะสม\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666634600811,"sku":"990-10-XX-01-05 MOD:165353-07","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-xx-01-05-mod-165353-07-vibration-transmitter-2j5h1xmjwj0_9fd15594-230c-4b4e-9191-adb6f4b6f232.jpg?v=1765444450"},{"product_id":"bently-nevada-991-06-70-01-cn-991-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-06-70-01-CN 991 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-06-70-01-CN\u003c\/strong\u003e เป็นตัวส่งสัญญาณแรงดัน \u003cstrong\u003e991\u003c\/strong\u003e แบบ 2 สาย ใช้พลังงานจากวงจร ออกแบบมาเพื่อวัดตำแหน่งเพลาแกนและการเคลื่อนที่แรงดันบนเครื่องจักรหมุน ตัวส่งสัญญาณประมวลผลสัญญาณดิบจากระบบโพรบใกล้ที่เข้ากันได้ และปรับสัญญาณให้เป็นเอาต์พุต 4 ถึง 20 mA DC ที่เสถียรซึ่งสัมพันธ์โดยตรงกับการเคลื่อนที่ทางกล การออกแบบนี้ช่วยให้สามารถรวมเข้ากับ PLC, สถาปัตยกรรม DCS หรือระบบ SCADA ได้โดยตรงโดยไม่ต้องใช้แร็คเครื่องมือตรวจสอบการป้องกันเครื่องจักรเฉพาะทาง มอบการตรวจสอบอย่างต่อเนื่องและคุ้มค่าสำหรับทรัพย์สินอุตสาหกรรมที่สำคัญซึ่งต้องการติดตามการเคลื่อนที่แกนเพื่อป้องกันความล้มเหลวของตลับลูกปืนแรงดันอย่างรุนแรง\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสถาปัตยกรรม 2 สายแบบใช้พลังงานจากวงจร ลดภาระการเดินสายและค่าใช้จ่ายในการติดตั้ง\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตอนาล็อก 4 ถึง 20 mA DC มาตรฐาน เชื่อมต่อโดยตรงกับระบบควบคุมกระบวนการ\u003c\/li\u003e\n\u003cli\u003eแจ็ค BNC ด้านหน้าแผงควบคุมให้สัญญาณแรงดันดิบแบบบัฟเฟอร์สำหรับการวินิจฉัยและเครื่องเก็บข้อมูลแบบพกพา\u003c\/li\u003e\n\u003cli\u003eเทคโนโลยีเซ็นเซอร์กระแสไหลวนแบบไม่สัมผัส ช่วยให้ใช้งานได้ยาวนานโดยไม่มีการสึกหรอ\u003c\/li\u003e\n\u003cli\u003eออกแบบกะทัดรัดประหยัดพื้นที่ เหมาะสำหรับการติดตั้งบนราง DIN ความหนาแน่นสูงโดยตรง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการเคลื่อนที่แรงดันแกนของเครื่องอัดแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eการติดตามตำแหน่งโรเตอร์ของกังหันไอน้ำและก๊าซ\u003c\/li\u003e\n\u003cli\u003eการจัดแนวเพลาปั๊มป้อนน้ำหม้อน้ำแรงดันสูง\u003c\/li\u003e\n\u003cli\u003eการวินิจฉัยการสึกหรอของตลับลูกปืนแรงดันเกียร์อุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eการกำหนดตำแหน่งเพลาพัดลมแบบบังคับและแบบเหนี่ยวนำ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e991: ตัวส่งสัญญาณแรงดัน\u003c\/li\u003e\n\u003cli\u003e06: ความเข้ากันได้ของโพรบใกล้ 3300 XL ขนาด 8 มม. กับช่วงเชิงเส้น 1.0 มม.\u003c\/li\u003e\n\u003cli\u003e70: ตัวเลือกความยาวระบบ 7.0 เมตร\u003c\/li\u003e\n\u003cli\u003e01: ตัวเลือกการติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/li\u003e\n\u003cli\u003eCN: ตัวเลือกการอนุมัติที่ได้รับการรับรองสำหรับมาตรฐานเฉพาะภูมิภาคหรือประเทศ (จีน\/NEPSI\/GB)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\" style=\"width: 37.9061%;\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\" style=\"width: 61.7329%;\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\" style=\"width: 37.9061%;\"\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd data-row=\"2\" style=\"width: 61.7329%;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\" style=\"width: 37.9061%;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd data-row=\"3\" style=\"width: 61.7329%;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\" style=\"width: 37.9061%;\"\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd data-row=\"4\" style=\"width: 61.7329%;\"\u003eตัวส่งสัญญาณแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\" style=\"width: 37.9061%;\"\u003eสัญญาณขาออก\u003c\/td\u003e\n\u003ctd data-row=\"5\" style=\"width: 61.7329%;\"\u003e4 ถึง 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\" style=\"width: 37.9061%;\"\u003eแรงดันไฟฟ้าขาเข้า\u003c\/td\u003e\n\u003ctd data-row=\"6\" style=\"width: 61.7329%;\"\u003e17 ถึง 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\" style=\"width: 37.9061%;\"\u003eช่วงเชิงเส้น\u003c\/td\u003e\n\u003ctd data-row=\"7\" style=\"width: 61.7329%;\"\u003e1.0 มม. (ประมาณ 40 มิล)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\" style=\"width: 37.9061%;\"\u003eอุณหภูมิการทำงานของตัวส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"8\" style=\"width: 61.7329%;\"\u003e-35 ถึง +85 องศาเซลเซียส (-31 ถึง +185 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\" style=\"width: 37.9061%;\"\u003eอุณหภูมิการเก็บรักษาตัวส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"9\" style=\"width: 61.7329%;\"\u003e-51 ถึง +100 องศาเซลเซียส (-60 ถึง +212 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\" style=\"width: 37.9061%;\"\u003eอุณหภูมิการทำงานของโพรบ\u003c\/td\u003e\n\u003ctd data-row=\"10\" style=\"width: 61.7329%;\"\u003e-52 ถึง +177 องศาเซลเซียส (-62 ถึง +351 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\" style=\"width: 37.9061%;\"\u003eวัสดุตัวเรือน\u003c\/td\u003e\n\u003ctd data-row=\"11\" style=\"width: 61.7329%;\"\u003eเหล็กชุบสังกะสีหรือโพลิเมอร์โครงสร้าง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\" style=\"width: 37.9061%;\"\u003eฐานติดตั้ง\u003c\/td\u003e\n\u003ctd data-row=\"12\" style=\"width: 61.7329%;\"\u003eติดตั้งบนราง DIN ขนาด 35 มม. (หรือการติดตั้งแบบบัลค์เฮด)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\" style=\"width: 37.9061%;\"\u003eน้ำหนักเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd data-row=\"13\" style=\"width: 61.7329%;\"\u003e0.43 กก. (0.9 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\" style=\"width: 37.9061%;\"\u003eน้ำหนักระบบรวม\u003c\/td\u003e\n\u003ctd data-row=\"14\" style=\"width: 61.7329%;\"\u003eน้ำหนักระบบรวม 0.82 กก. (1.8 ปอนด์) โดยประมาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\" style=\"width: 37.9061%;\"\u003eขนาดฐาน \/ พื้นที่ติดตั้ง\u003c\/td\u003e\n\u003ctd data-row=\"15\" style=\"width: 61.7329%;\"\u003e100.1 มม. x 73.9 มม. (3.94 นิ้ว x 2.91 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\" style=\"width: 37.9061%;\"\u003eรูปแบบรูยึด (บัลค์เฮด)\u003c\/td\u003e\n\u003ctd data-row=\"16\" style=\"width: 61.7329%;\"\u003e69.9 มม. x 63.5 มม. (2.75 นิ้ว x 2.50 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\" style=\"width: 37.9061%;\"\u003eความสูง (รวมคลิป DIN)\u003c\/td\u003e\n\u003ctd data-row=\"17\" style=\"width: 61.7329%;\"\u003e53.3 มม. (2.10 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\" style=\"width: 37.9061%;\"\u003eความสูง (เฉพาะตัวเครื่อง)\u003c\/td\u003e\n\u003ctd data-row=\"18\" style=\"width: 61.7329%;\"\u003e42.6 มม. (1.68 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\" style=\"width: 37.9061%;\"\u003eเส้นผ่านศูนย์กลางรูยึด\u003c\/td\u003e\n\u003ctd data-row=\"19\" style=\"width: 61.7329%;\"\u003e5.8 มม. (0.23 นิ้ว), 4 จุด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eการเชื่อมต่อ \/ อินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eขาเชื่อมต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e+4-20mA \/ +VTX\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eขั้วจ่ายไฟบวก \/ ลูปกระแสขาเข้า\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-4-20mA \/ -VTX\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eขั้วจ่ายไฟลบ \/ ลูปกระแสขากลับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePROX\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eขั้วนำสัญญาณศูนย์โพรบใกล้เคียง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eขั้วอ้างอิงทั่วไป \/ ชิลด์โคแอกเชียล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSHLD\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eขั้วกราวด์ชิลด์เครื่องมือ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eแจ็ค BNC\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eสัญญาณแรงดันไฟฟ้าแบบไดนามิก (10.2 mV\/ไมโครเมตร)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งบนราง DIN:\u003c\/strong\u003e ยึดตัวเรือนอย่างแน่นหนาบนราง DIN มาตรฐานขนาด 35 มม. โดยใช้คลิปติดตั้ง DIN ที่รวมอยู่ภายในกล่องอุตสาหกรรมที่มีระดับการป้องกัน IP54 หรือสูงกว่า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eตัวเลือกการติดตั้งแบบบัลค์เฮด:\u003c\/strong\u003e หรือใช้รูยึด 4 รู (เส้นผ่านศูนย์กลาง $5.8 \\text{ มม}$) ที่เว้นระยะ $69.9 \\text{ มม} \\times 63.5 \\text{ มม}$ สำหรับติดตั้งบนแผงแบน\/บัลค์เฮดโดยใช้สกรู 6-32 x 1.326 ที่ให้มา\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eโปรโตคอลการป้องกัน:\u003c\/strong\u003e เชื่อมต่อสายป้องกันของสายส่งสัญญาณขาเข้าเข้ากับขั้ว SHLD ชิลด์ลูปควบคุมภายนอกต้องต่อกราวด์ที่ฝั่งระบบควบคุม (PLC\/DCS) เท่านั้นเพื่อกำจัดลูปกราวด์\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตั้งช่องว่างของโพรบ:\u003c\/strong\u003e ตั้งช่องว่างโพรบทางกายภาพโดยใช้โวลต์มิเตอร์ดิจิทัลวัดข้ามแจ็ค BNC หรือขั้ว COM เพื่อยืนยันว่าเซ็นเซอร์อยู่ในช่วงแรงดันเชิงเส้นก่อนใช้งาน\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการแยกสายไฟ:\u003c\/strong\u003e นำสายเซ็นเซอร์ขาเข้าและสายลูปกระแสขาออกทั้งหมดออกห่างจากสายไฟ AC แรงดันสูงหรือสายไดรฟ์ความถี่แปรผันเพื่อลดสัญญาณรบกวน EMI\/RFI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eตัวเลือกการอนุมัติ CN (ได้รับการรับรองสำหรับการปฏิบัติตามมาตรฐานพื้นที่อันตรายระดับภูมิภาค เช่น มาตรฐาน NEPSI \/ GB)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eขนาดตัวเครื่องที่แน่นอนสำหรับการวางแผนตู้ควบคุมคืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eขนาดฐานกว้าง 100.1 มม. ยาว 73.9 มม. และสูงสุด 53.3 มม. เมื่อแนบคลิปราง DIN ขนาด 35 มม.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eขนาดรูติดตั้งแบบบัลค์เฮดทางเลือกมีขนาดเท่าไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eหน่วยนี้มีรูยึด 4 รู เส้นผ่านศูนย์กลาง 5.8 มม. จัดวางในรูปแบบสี่เหลี่ยมผืนผ้าขนาด 69.9 มม. x 63.5 มม. อย่างแม่นยำ  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันของขั้วต่อ BNC บนแผงหน้าคืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eให้เอาต์พุตแรงดันดิบที่ไม่มีการปรับสภาพและมีบัฟเฟอร์สำหรับเชื่อมต่อเครื่องมือวินิจฉัยและเครื่องวิเคราะห์สัญญาณไดนามิกโดยไม่รบกวนลูปกระแส 4 ถึง 20 mA  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้ต้องการสายจ่ายไฟแยกต่างหากหรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ อุปกรณ์ทำงานโดยใช้พลังงานจากลูปอย่างเต็มที่ ดึงแรงดันไฟฟ้าทำงานโดยตรงจากสายสัญญาณ 4 ถึง 20 mA  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นถ้าตัวเลือกความยาวระบบไม่ตรงกับโพรบ?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการเชื่อมต่อสายโพรบ\/สายต่อขยายที่ไม่ตรงกับการปรับเทียบระยะ 7.0 เมตรที่ระบุจะทำให้เกิดความไม่เชิงเส้นของการวัดอย่างรุนแรงและข้อผิดพลาดของปัจจัยสเกล  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณนี้สามารถติดตั้งในสภาพแวดล้อมกลางแจ้งได้หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eต้องติดตั้งภายในกล่องต่อสายกันน้ำที่มีมาตรฐาน NEMA 4X หรือ IP65\/66 เพื่อป้องกันความชื้น ฝุ่น และแสงแดดโดยตรง  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเอาต์พุตของเครื่องส่งสัญญาณเข้ากันได้กับการ์ดอินพุตแอนะล็อกมาตรฐานหรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ เอาต์พุต 4 ถึง 20 mA เชื่อมต่อโดยตรงกับการ์ดอินพุตแอนะล็อกแบบต่างศักย์หรือแบบขั้วเดียวมาตรฐานบน PLC หรือ DCS ใดก็ได้  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eรหัสต่อท้าย CN มีความหมายว่าอย่างไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรหัสต่อท้าย CN หมายถึงการปฏิบัติตามมาตรฐานการรับรองเฉพาะภูมิภาค โดยทั่วไปตรงกับมาตรฐานความปลอดภัยและพื้นที่อันตรายของประเทศจีน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถปรับเทียบหน่วยในภาคสนามสำหรับช่วงเชิงเส้นที่แตกต่างกันได้หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ ช่วงเชิงเส้นและปัจจัยสเกลถูกตั้งค่าคงที่และปรับเทียบจากโรงงาน การเปลี่ยนช่วงต้องใช้การกำหนดค่ารุ่นที่แตกต่างกัน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการต่อขั้วลูปย้อนกลับส่งผลต่อเครื่องส่งสัญญาณอย่างไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eอุปกรณ์นี้มีไดโอดภายในเพื่อป้องกันการต่อขั้วกลับ หมายความว่าจะไม่ทำงานเมื่อสายต่อกลับด้านแต่จะไม่เสียหาย  \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666643317099,"sku":"991-06-70-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-70-01-cn-991-thrust-transmitter-vzobeoytryv_65189d7a-0c45-4520-9f64-15e9dd9f51fd.jpg?v=1765444581"},{"product_id":"bently-nevada-990-04-50-01-00-990-vibration-transmitter","title":"เบนท์ลีย์ เนวาด้า 990-04-50-01-00 เครื่องส่งสัญญาณการสั่นสะเทือน 990","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณสั่นสะเทือน 990\u003c\/strong\u003e ให้ส่วนติดต่อการวัดการสั่นสะเทือนที่เรียบง่ายสำหรับเครื่องจักรหมุนโดยแปลงการเคลื่อนที่ของโพรบใกล้เป็น \u003cstrong\u003eสัญญาณขาออก 4–20 mA มาตรฐาน\u003c\/strong\u003e ออกแบบมาสำหรับการใช้งาน OEM ที่ต้องการแสดงการสั่นสะเทือนเพื่อใช้ในตรรกะระบบควบคุมแทนการตรวจสอบสภาพเต็มรูปแบบ\u003c\/p\u003e\n\u003cp\u003eการกำหนดค่านี้ (\u003cstrong\u003e990-04-50-01-00\u003c\/strong\u003e) ได้รับการปรับแต่งสำหรับการติดตั้งระบบระยะสั้นโดยใช้สายโพรบยาว 5.0 เมตรและโครงสร้างติดตั้งบนราง DIN ทำงานเป็นอุปกรณ์ใช้พลังงานจากลูปและรวมการปรับสัญญาณภายในเพื่อลดความต้องการเครื่องมือภายนอก\u003c\/p\u003e\n\u003cp\u003eหลักการวัดขึ้นอยู่กับการเคลื่อนที่ของโพรบใกล้ ซึ่งถูกประมวลผลเป็นความกว้างการสั่นสะเทือนสูงสุดถึงต่ำสุดที่เหมาะสมสำหรับการป้องกันเครื่องจักรโดยใช้แนวโน้ม\u003c\/p\u003e\n\u003ch3\u003eการแยกการกำหนดค่า\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eการเลือก\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003eเครื่องส่งสัญญาณสั่นสะเทือน 990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงเต็มสเกล\u003c\/td\u003e\n\u003ctd\u003e0–4 mils pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความยาวระบบ\u003c\/td\u003e\n\u003ctd\u003e5.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eคลิปติดราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติ\u003c\/td\u003e\n\u003ctd\u003eรุ่น CSA \/ ATEX \/ สำหรับทางทะเล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eลักษณะการทำงาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสถาปัตยกรรมลูปสองสายที่ใช้พลังงาน\u003c\/li\u003e\n\u003cli\u003eสัญญาณสั่นสะเทือนสัดส่วน 4–20 mA แบบตรง\u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับระบบโพรบใกล้ 3300 NSv\u003c\/li\u003e\n\u003cli\u003eการปรับสัญญาณและการปรับสเกลภายใน\u003c\/li\u003e\n\u003cli\u003eรูปแบบติดตั้งบนราง DIN สำหรับการรวมแผงควบคุม\u003c\/li\u003e\n\u003cli\u003eปรับเทียบลูปได้ผ่านจุดเชื่อมต่อภายนอก\u003c\/li\u003e\n\u003cli\u003eแสดงข้อผิดพลาดผ่านพฤติกรรมการกดสัญญาณ\u003c\/li\u003e\n\u003cli\u003eออกแบบสำหรับชุดเครื่องจักร OEM ขนาดกะทัดรัด\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eคอมเพรสเซอร์แรงเหวี่ยงขนาดเล็ก\u003c\/li\u003e\n\u003cli\u003eชุดปั๊มอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eชุดพัดลมในระบบ HVAC\u003c\/li\u003e\n\u003cli\u003eอุปกรณ์หมุนทั่วไป\u003c\/li\u003e\n\u003cli\u003eแผงควบคุมเครื่องจักร OEM\u003c\/li\u003e\n\u003cli\u003eจุดแนวโน้มการสั่นสะเทือนเสริม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eลักษณะทางไฟฟ้า\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eแรงดันไฟฟ้าเลี้ยง\u003c\/td\u003e\n\u003ctd\u003e+12 ถึง +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสัญญาณขาออก\u003c\/td\u003e\n\u003ctd\u003eการสั่นสะเทือนสัดส่วน 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานลูป\u003c\/td\u003e\n\u003ctd\u003eสูงสุด 1000 โอห์ม (รวมสายเคเบิล)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการจำกัดกระแส\u003c\/td\u003e\n\u003ctd\u003eกระแสจำกัด 23 mA ปกติ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งสัญญาณเข้า\u003c\/td\u003e\n\u003ctd\u003eระบบโพรบใกล้เคียง 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางกล\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักเครื่องส่งสัญญาณ\u003c\/td\u003e\n\u003ctd\u003e0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักระบบทั้งหมด\u003c\/td\u003e\n\u003ctd\u003e0.82 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดเป้าหมายขั้นต่ำ\u003c\/td\u003e\n\u003ctd\u003e9.5 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทตัวเรือน\u003c\/td\u003e\n\u003ctd\u003eโมดูลติดตั้งบนราง DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาด (สูง×กว้าง×ลึก)\u003c\/td\u003e\n\u003ctd\u003e53.3 × 73.9 × 100.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eขีดจำกัดสิ่งแวดล้อม\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eเงื่อนไข\u003c\/th\u003e\n\u003cth\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-35 °C ถึง +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-51 °C ถึง +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความชื้น\u003c\/td\u003e\n\u003ctd\u003eการควบแน่น 100% (ไม่จมน้ำ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eการติดตั้งบนราง DIN ต้องมีการกราวด์แผงที่มั่นคงเพื่อให้สัญญาณมีความสมบูรณ์ภายใต้สภาพแวดล้อมที่มีเสียงรบกวนในอุตสาหกรรม การเดินสายควรหลีกเลี่ยงสายไฟแรงดันสูงเพื่อลดการรบกวนแม่เหล็กไฟฟ้า\u003c\/p\u003e\n\u003cp\u003eช่องว่างโพรบต้องตั้งอยู่ในช่วงที่กำหนดเพื่อรักษาการตอบสนองการวัดเชิงเส้น การเริ่มต้นระบบควรตรวจสอบกระแสลูปที่เสถียรก่อนเปิดใช้งานตรรกะสัญญาณเตือนในระบบควบคุม\u003c\/p\u003e\n\u003ch3\u003eคำจำกัดความอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eขั้วต่อ\u003c\/th\u003e\n\u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLOOP +\u003c\/td\u003e\n\u003ctd\u003eพลังงาน + สัญญาณ 4–20 mA ออก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eสัญญาณอ้างอิง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eสัญญาณวินิจฉัยการสั่นสะเทือนดิบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเครื่องส่งสัญญาณนี้ส่งออกสัญญาณประเภทใด?\u003c\/strong\u003e\u003cbr\u003eให้สัญญาณ 4–20 mA ที่สัดส่วนกับความกว้างของการสั่นสะเทือน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถทำงานได้โดยไม่ต้องมีการปรับสัญญาณภายนอกหรือไม่?\u003c\/strong\u003e\u003cbr\u003eใช่ การปรับสัญญาณถูกรวมอย่างสมบูรณ์ภายในอุปกรณ์\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eใช้วิธีการติดตั้งแบบใด?\u003c\/strong\u003e\u003cbr\u003eเวอร์ชันนี้ใช้การติดตั้งบนราง DIN ขนาด 35 มม. มาตรฐาน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อกำหนดของระบบโพรบคืออะไร?\u003c\/strong\u003e\u003cbr\u003eทำงานร่วมกับระบบโพรบใกล้เคียง Bently Nevada 3300 NSv\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเหมาะสำหรับการวินิจฉัยการสั่นสะเทือนเต็มรูปแบบหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ ใช้สำหรับการตรวจสอบระดับแนวโน้มและตรรกะการป้องกัน\u003c\/p\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eรุ่น: 990 เครื่องส่งสัญญาณการสั่นสะเทือน\u003c\/li\u003e\n\u003cli\u003eตัวเลือกเต็มสเกล: 04 = 0–4 mils pp\u003c\/li\u003e\n\u003cli\u003eความยาวระบบ: 50 = 5.0 เมตร\u003c\/li\u003e\n\u003cli\u003eการติดตั้ง: 01 = คลิปติดตั้งบนราง DIN\u003c\/li\u003e\n\u003cli\u003eการอนุมัติ: 00 = การกำหนดค่ามาตรฐาน\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666732216683,"sku":"990-04-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-01-05-vibration-transmitter-p3uh3udifdj_ffecf2e9-e202-4102-bd8c-f6eef4d50a92.jpg?v=1765446688"},{"product_id":"bently-nevada-991-06-70-02-01-thrust-transmitter","title":"เบนท์ลีย์ เนวาด้า 991-06-70-02-01 เครื่องส่งแรงดัน","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 991-06-70-02-01\u003c\/strong\u003e เป็นเครื่องส่งสัญญาณแรงดันแบบ 2 สาย ใช้พลังงานจากลูป ออกแบบมาเพื่อประมวลผลสัญญาณจากระบบโพรบใกล้เคียงเพื่อวัดตำแหน่งแกนแกนหรือการเคลื่อนที่แรงดันแกนบนเครื่องจักรหมุน อุปกรณ์นี้ปรับสัญญาณดิบเป็นเอาต์พุตอนาล็อกมาตรฐาน 4 ถึง 20 mA ที่สัดส่วนกับการเคลื่อนที่เป้าหมายทั้งหมด ออกแบบมาให้เชื่อมต่อโดยตรงกับระบบควบคุมเช่น PLC หรือสถาปัตยกรรม DCS โดยไม่ต้องใช้แร็คมอนิเตอร์แยกต่างหาก ทำให้การตั้งค่ามีต้นทุนต่ำสำหรับการปกป้องเครื่องจักรที่สำคัญ หน่วยนี้ได้รับการปรับแต่งให้เหมาะสมกับการรวมกับทรานสดิวเซอร์โพรบใกล้เคียงที่เข้ากันได้เพื่อให้มั่นใจในการตรวจสอบการเคลื่อนที่แรงดันแกนที่แม่นยำและรวดเร็วในสภาพแวดล้อมอุตสาหกรรม\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการออกแบบแบบ 2 สายที่ใช้พลังงานจากลูปช่วยลดความซับซ้อนของการเดินสายและลดต้นทุนการติดตั้ง\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตอนาล็อก 4 ถึง 20 mA โดยตรงเชื่อมต่อกับระบบ PLC และ DCS ได้อย่างราบรื่น\u003c\/li\u003e\n\u003cli\u003eหลักการวัดกระแสไหลวนแบบไม่สัมผัสให้ความน่าเชื่อถือในระยะยาว\u003c\/li\u003e\n\u003cli\u003eขั้วต่อ BNC เฉพาะสำหรับสัญญาณแรงดันดิบแบบบัฟเฟอร์สำหรับการวินิจฉัย\u003c\/li\u003e\n\u003cli\u003eการออกแบบขนาดกะทัดรัดสำหรับติดตั้งบนราง DIN ช่วยประหยัดพื้นที่ตู้ควบคุม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบการเคลื่อนที่แรงดันแกนบนเครื่องอัดแรงเหวี่ยง\u003c\/li\u003e\n\u003cli\u003eการติดตามตำแหน่งแกนโรเตอร์ของกังหันไอน้ำและก๊าซ\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบเพลาปั๊มป้อนน้ำหม้อน้ำ\u003c\/li\u003e\n\u003cli\u003eการประเมินการสึกหรอของตลับลูกปืนแรงดันเกียร์อุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eการกำหนดตำแหน่งเพลาพัดลมและเครื่องเป่าความเร็วสูง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e991: เครื่องส่งสัญญาณแรงดัน\u003c\/li\u003e\n\u003cli\u003e06: ความเข้ากันได้กับโพรบใกล้เคียง 3300 XL ขนาด 8 มม. พร้อมช่วงเชิงเส้น 1.0 มม.\u003c\/li\u003e\n\u003cli\u003e70: ตัวเลือกความยาวระบบ 7.0 เมตร\u003c\/li\u003e\n\u003cli\u003e02: ตัวเลือกการติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/li\u003e\n\u003cli\u003e01: ตัวเลือกการอนุมัติหลายรายการ (ATEX, IECEx, CSA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eเครื่องส่งสัญญาณแรงดัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eสัญญาณเอาต์พุต\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4 ถึง 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eความต้องการพลังงาน\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e17 ถึง 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eปัจจัยสเกล\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e4 mA\/มม. (หรือเทียบเท่าการสอบเทียบแบบมิล)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eช่วงอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e-35 ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eช่วงอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-40 ถึง +100 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eวัสดุของตัวเครื่อง\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eเหล็กชุบสังกะสีหรือโพลิเมอร์เฉพาะทาง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eประเภทการติดตั้ง\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eการติดตั้งบนราง DIN ขนาด 35 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eน้ำหนักโดยประมาณ\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eน้ำหนักประมาณ 0.43 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eขนาด\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eกว้าง 25.4 มม. x สูง 112 มม. x ลึก 99 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eการเชื่อมต่อ \/ อินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eขาเชื่อมต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e+4-20mA \/ +VTX\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eขั้วไฟฟ้าบวก \/ การรับกระแสลูป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-4-20mA \/ -VTX\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eขั้วไฟฟ้าลบ \/ การส่งกระแสลูปกลับ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePROX\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eขั้วรับสัญญาณโพรบใกล้เคียง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eขั้วอ้างอิงทั่วไป\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSHLD\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eขั้วต่อสายดิน \/ ชิลด์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eแจ็ค BNC\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eเอาต์พุตแรงดันดิบแบบบัฟเฟอร์ (10.2 mV\/ไมโครเมตร)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งบนราง DIN:\u003c\/strong\u003e คลิปตัวส่งสัญญาณอย่างมั่นคงบนราง DIN ขนาด 35 มม. ที่มีการต่อสายดินภายในกล่องที่มีมาตรฐาน IP54 หรือดีกว่า เพื่อป้องกันฝุ่นและน้ำเข้า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการต่อชิลด์:\u003c\/strong\u003e เชื่อมต่อชิลด์สายเคเบิลทรานสดิวเซอร์กับขั้ว SHLD ของเครื่องส่งสัญญาณ และตรวจสอบให้แน่ใจว่าชิลด์วงจรควบคุมกราวด์ที่ด้าน DCS\/PLC เท่านั้น\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับช่องว่างโพรบ:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าโพรบใกล้เคียงที่เกี่ยวข้องถูกปรับเชิงกลไปยังแรงดันไฟฟ้ากลางช่วงกายภาพก่อนปรับเทียบจุดศูนย์ 4 ถึง 20 mA  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเดินสายเคเบิล:\u003c\/strong\u003e แยกสายโพรบใกล้เคียงขาเข้าและสายวงจรกระแสขาออกออกจากสายไฟ AC แรงดันสูงเพื่อป้องกันการรบกวนแม่เหล็ก  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eขั้วจ่ายไฟ:\u003c\/strong\u003e ตรวจสอบขั้วแรงดันไฟฟ้าวงจรก่อนเปิดใช้งานเพื่อป้องกันความเสียหายต่อไดโอดป้องกันภายใน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX  \u003c\/li\u003e\n\u003cli\u003eIECEx  \u003c\/li\u003e\n\u003cli\u003eCSA  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย  \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันหลักของเครื่องส่งสัญญาณนี้คืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eแปลงสัญญาณโพรบใกล้เคียงดิบเป็นสัญญาณกระแส 4 ถึง 20 mA ที่สัดส่วนกับการเคลื่อนที่ตามแกนของเพลาหมุน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอุปกรณ์นี้ต้องการระบบตรวจสอบแบบแร็คแยกต่างหากหรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ อุปกรณ์นี้ออกแบบมาเพื่อส่งข้อมูลโดยตรงไปยัง PLC หรือ DCS โดยไม่ต้องใช้ระบบตรวจสอบแบบแร็คแยกต่างหาก  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eวิศวกรเก็บข้อมูลการสั่นสะเทือนไดนามิกดิบจากหน่วยนี้อย่างไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eแจ็ค BNC ด้านหน้าช่วยให้เข้าถึงสัญญาณไดนามิกดิบโดยตรงโดยใช้เครื่องเก็บข้อมูลแบบพกพามาตรฐาน  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต้องใช้แรงดันไฟฟ้าวงจรลูปเท่าใดเพื่อจ่ายพลังงานให้หน่วยอย่างถูกต้อง?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเครื่องส่งสัญญาณทำงานได้อย่างมีประสิทธิภาพภายในช่วงแรงดันไฟฟ้าวงจรลูปมาตรฐาน 17 ถึง 30 VDC  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถติดตั้งหน่วยนี้โดยตรงบนตัวเครื่องจักรได้หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eควรติดตั้งในกล่องต่อสายภาคสนามที่ป้องกันหรือกล่องควบคุมเพื่อป้องกันความร้อนสูงและการสั่นสะเทือนมากเกินไป  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นหากขั้ววงจรถูกต่อกลับโดยไม่ตั้งใจในระหว่างการเดินสาย?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการป้องกันขั้วกลับภายในช่วยป้องกันความเสียหายของชิ้นส่วน แม้ว่าหน่วยจะไม่ส่งสัญญาณกระแสจนกว่าจะแก้ไขขั้วให้ถูกต้อง  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจำเป็นต้องปรับเทียบในระหว่างการติดตั้งครั้งแรกหรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eฮาร์ดแวร์ได้รับการปรับเทียบจากโรงงานให้เหมาะสมกับความยาวระบบและประเภทโพรบเฉพาะ โดยต้องตรวจสอบช่องว่างระหว่างโพรบเท่านั้นในระหว่างการติดตั้ง  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถเชื่อมต่อระบบโพรบความยาว 5 เมตรกับตัวเลือกเครื่องส่งสัญญาณความยาว 7.0 เมตรได้หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ การเลือกความยาวระบบไฟฟ้าที่ไม่ตรงกันจะทำให้เกิดข้อผิดพลาดเชิงเส้นอย่างรุนแรงและทำลายความแม่นยำของสัญญาณขาออก  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eความสำคัญของตัวเลือกคำต่อท้ายที่ได้รับการอนุมัติหลายรายการคืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรับรองเครื่องส่งสัญญาณสำหรับการติดตั้งในพื้นที่อันตรายเฉพาะภายใต้แนวทาง ATEX, IECEx และ CSA เมื่อใช้ร่วมกับอุปกรณ์กั้นสัญญาณ  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eควรจัดการกับสัญญาณรบกวนไฟฟ้าจากตัวขับความถี่แปรผันอย่างไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตรวจสอบให้แน่ใจว่าชิลด์ทั้งหมดสมบูรณ์ แยกอย่างถูกต้องจากกราวด์ของเครื่องจักร และเชื่อมต่อเฉพาะกับรางร่วมของเครื่องมือที่ถูกต้องเท่านั้น  \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666733953387,"sku":"991-06-70-02-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-70-02-01-thrust-transmitter-fb4rym3o53w_88ad2eb0-7ac2-4e76-be22-962babfff94a.jpg?v=1765446737"},{"product_id":"bently-nevada-991-25-70-01-05-thrust-transmitter","title":"Bently Nevada 991-25-70-01-05 Thrust Transmitter","description":"\u003cp\u003eThe Bently Nevada 991-25-70-01-05 is a 2-wire loop-powered thrust (axial displacement) transmitter developed for OEM machinery monitoring applications on compressors, pumps, motors, and rotating equipment. It converts the proximity probe signal into a standard 4–20 mA output for direct integration with PLC, DCS, or control systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eSuffix CodeOption \/ ParameterTechnical Description\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e-25\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-70\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e-01\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eMounting Option\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e-05\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated proximity probe driver circuit\u003c\/li\u003e\n\u003cli\u003e4–20 mA proportional axial displacement output\u003c\/li\u003e\n\u003cli\u003eNon-interacting Zero and Span adjustments\u003c\/li\u003e\n\u003cli\u003ePower-up signal suppression to avoid false trips\u003c\/li\u003e\n\u003cli\u003e“Not OK” signal blanking diagnostics\u003c\/li\u003e\n\u003cli\u003eDedicated PROX OUT dynamic signal connector\u003c\/li\u003e\n\u003cli\u003eEncapsulated construction for high-humidity environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameterDescription\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e4–20 mA DC loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e+12 to +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eDynamic Output\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003ePROX OUT coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e100% condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.43 kg (0.95 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003ch4\u003ePhysical Mechanical Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the transmitter onto a standard 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003eInstall away from high-temperature sources\u003c\/li\u003e\n\u003cli\u003eUse a 304 stainless steel enclosure for outdoor environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProbe Installation \u0026amp; Gapping\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse only matched 3300 NSv probe systems\u003c\/li\u003e\n\u003cli\u003eMaintain a total system cable length of exactly 7.0 meters\u003c\/li\u003e\n\u003cli\u003eVerify the shaft target area meets minimum sizing requirements\u003c\/li\u003e\n\u003cli\u003eAdjust the probe to the midpoint of the linear operating range\u003c\/li\u003e\n\u003cli\u003eConfirm the PROX OUT voltage is approximately 6.5 Vdc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Loop Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the transmitter to a +12 to +35 Vdc loop supply\u003c\/li\u003e\n\u003cli\u003eVerify Power (+) and Signal (-) polarity before energizing\u003c\/li\u003e\n\u003cli\u003eTighten the miniature coaxial connector securely\u003c\/li\u003e\n\u003cli\u003eGround the cable shield at the control cabinet side only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eZero \u0026amp; Span Calibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjust the Zero potentiometer at the mechanical center position\u003c\/li\u003e\n\u003cli\u003eSet loop output current to 12 mA during midpoint calibration\u003c\/li\u003e\n\u003cli\u003eAdjust the Span potentiometer at full-scale displacement\u003c\/li\u003e\n\u003cli\u003eNon-interacting potentiometers minimize recalibration iterations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhy is the initial probe gap important?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncorrect gaps limit usable measurement range\u003c\/li\u003e\n\u003cli\u003eImproper installation may allow probe-to-rotor contact\u003c\/li\u003e\n\u003cli\u003eThe operating gap must remain within 0.25 to 1.65 mm (10 to 65 mils)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhy does the loop current drop below 3.6 mA?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe transmitter has entered “Not OK” protection mode\u003c\/li\u003e\n\u003cli\u003eProbe or extension cable may be open or shorted\u003c\/li\u003e\n\u003cli\u003eThe coaxial connector may not be fully seated\u003c\/li\u003e\n\u003cli\u003eThe failsafe output prevents false PLC or DCS trip signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCan an oscilloscope connect directly to the PROX OUT port?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe PROX OUT connector is non-isolated from the 4–20 mA loop\u003c\/li\u003e\n\u003cli\u003eStandard grounded oscilloscopes can create ground loops\u003c\/li\u003e\n\u003cli\u003eUse a battery-powered meter or isolated interface adapter instead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCan the extension cable be shortened or spliced?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eModifying cable length is strictly prohibited\u003c\/li\u003e\n\u003cli\u003eCable impedance changes affect calibration accuracy\u003c\/li\u003e\n\u003cli\u003eShortening or extending the cable invalidates factory calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Notes\u003c\/h3\u003e\n\u003cp\u003eThe transmitter is specifically designed for use with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3300 NSv proximity probe systems\u003c\/li\u003e\n\u003cli\u003eOEM centrifugal compressors\u003c\/li\u003e\n\u003cli\u003eSmall pumps and rotating machinery\u003c\/li\u003e\n\u003cli\u003ePLC and DCS analog input systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735296875,"sku":"991-25-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-70-01-05-thrust-transmitter-4nnys1eggun_8af749c8-fb0e-4137-a612-cfed2c951e30.jpg?v=1765446775"},{"product_id":"bently-nevada-991-25-50-03-05-991-thrust-transmitter","title":"Bently Nevada 991-25-50-03-05 991 Thrust Transmitter","description":"\u003cp\u003e\u003cstrong\u003e991 Thrust Transmitter 991-25-50-03-05\u003c\/strong\u003e is a 2-wire, loop-powered axial displacement transmitter designed for continuous thrust position measurement using a 3300 NSv proximity probe and matching extension cable system. The transmitter integrates the Proximitor sensor internally and converts eddy-current scaling signals into a proportional 4 to 20 mA output for machinery control systems monitoring rotor dynamics and shaft axial position. The unit provides non-isolated PROX OUT and COM terminals for dynamic vibration and gap voltage diagnostics, incorporates Not OK signal defeat circuitry for fault suppression, and supports DIN-rail or bulkhead mounting in high-humidity industrial environments.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eSuffix Code Option \/ Parameter Technical Description\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e-25\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-50\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e-03\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eMounting Option\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDIN clips and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e-05\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameter Specification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eAxial Position Thrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eOne 3300 NSv proximity probe with extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e+12 to +35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4 to 20 mADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSignal Configuration\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2-wire loop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eWithin ±1.5% of full scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eAccuracy Reference\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eMeasured across 250 Ohm loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e1,000 Ohm at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eZero Adjustment\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eExternal non-interacting potentiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eSpan Adjustment\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eExternal non-interacting potentiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eNot OK Response Time\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eLess than 100 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eOutput Recovery Time\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eLess than 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eDynamic Signal Output\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eNon-isolated PROX OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eRecommended Isolation Adapter\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e122115-01 Test Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-35 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e-51 °C to +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e-52 °C to +177 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eProbe Storage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e-52 °C to +177 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e100% condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003eTransducer Tip Material\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003eProbe Cable Type\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003e75 Ohm coaxial FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"25\"\u003eOptional Cable Armor\u003c\/td\u003e\n\u003ctd data-row=\"25\"\u003eFlexible AISI 302 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"26\"\u003eTensile Strength\u003c\/td\u003e\n\u003ctd data-row=\"26\"\u003e222 N (50 lbf) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"27\"\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd data-row=\"27\"\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"28\"\u003eTypical System Weight\u003c\/td\u003e\n\u003ctd data-row=\"28\"\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"29\"\u003eProbe Thread Options\u003c\/td\u003e\n\u003ctd data-row=\"29\"\u003e1\/4-28, 3\/8-24, M8x1, M10x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"30\"\u003eMaximum Thread Engagement 1\/4-28\u003c\/td\u003e\n\u003ctd data-row=\"30\"\u003e0.375 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"31\"\u003eMaximum Thread Engagement 3\/8-24\u003c\/td\u003e\n\u003ctd data-row=\"31\"\u003e0.563 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"32\"\u003eMaximum Thread Engagement M8x1\u003c\/td\u003e\n\u003ctd data-row=\"32\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"33\"\u003eMaximum Thread Engagement M10x1\u003c\/td\u003e\n\u003ctd data-row=\"33\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrust Monitoring Limitations:\u003c\/strong\u003e Unlike continuous monitoring racks, the 991 transmitter cannot perform Timed OK channel defeat, Danger Bypass, or Trip Multiply functions. Connected PLCs or DCSs are not compatible with plant-wide diagnostic software like System 1 or Rule Paks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Calibration:\u003c\/strong\u003e Accurate probe physical gap adjustment is critical. Incorrect target gap settings prevent the loop from reaching full-scale limits in either the normal or counter directions, which deactivates machinery protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Materials:\u003c\/strong\u003e All eddy-current scaling specifications are calibrated using an AISI 4140 steel target. Other target materials will alter the loop accuracy and response characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement:\u003c\/strong\u003e When mounting the probe, the maximum thread engagement must not exceed 1.5 times the nominal thread diameter (0.375 in for 1\/4-28 threads, 0.563 in for 3\/8-24 threads, 12 mm for M8x1, and 15 mm for M10x1).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Polarity and Signal Isolation:\u003c\/strong\u003e The PROX OUT coaxial signal is not isolated from the 4 to 20 mA loop current. Connecting AC-powered oscilloscopes or analyzers directly can cause ground loops and fault alarms; use a 122115-01 \/ 990\/991 Test Adapter to invert and isolate the signal while maintaining standard polarity conventions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Connector Insulation:\u003c\/strong\u003e Ensure all coaxial connections between the 3300 NSv probe and the extension cable are clean, dry, and wrapped with self-mating silicone tape to maintain 100% condensing humidity protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminal 3 (COM) must be tied to the loop return or system ground at a single point. Keep instrument cable shields continuous up to the termination point and isolate them from the field housing to prevent electrical noise interference on the loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Adjustment Routing:\u003c\/strong\u003e Use the non-interacting zero and span potentiometers located under the transmitter label for minor loop calibration. For verification, a variable DC voltage source can be applied to the Test Input pin to confirm loop output current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 991 transmitter operate without an external Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The transmitter contains an integrated Proximitor sensor and directly accepts a 3300 NSv probe input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PROX OUT signal isolated from the loop output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The PROX OUT terminal is non-isolated and should be connected through the 122115-01 Test Adapter when using grounded AC-powered test equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which probe system lengths are supported by the 991-25-50-03-05 configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified configuration supports a 5.0 meter 3300 NSv probe and extension cable system length.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666741883243,"sku":"991-25-50-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-50-03-05-thrust-transmitter-5xhxta0jxjj_c6629be5-70ed-4b84-bd5f-c922465d505a.jpg?v=1765446881"},{"product_id":"bently-nevada-991-06-50-01-05-991-thrust-transmitter","title":"Bently Nevada 991-06-50-01-05 991 Thrust Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 991-06-50-01-05\u003c\/strong\u003e is a 2-wire, loop-powered machinery protection instrument designed to measure axial shaft displacement. This \u003cstrong\u003e991 Thrust Transmitter\u003c\/strong\u003e interfaces directly with a 3300 NSv proximity probe and its matching 5.0-meter extension cable. It processes proximity sensor signals into a standard 4 to 20 mA DC linear current output proportional to total thrust movement. This continuous monitoring signal integrates directly with standard programmable logic controllers (PLCs), distributed control systems (DCSs), or SCADA hardware without requiring dedicated machinery monitoring rack systems. The transmitter incorporates an internal Proximitor sensor within a single potted housing to withstand demanding industrial plant conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Proximitor sensor inside a standalone enclosure requires no external driver module\u003c\/li\u003e\n\u003cli\u003eNon-isolated PROX OUT and COM coaxial terminals provide dynamic voltage access for portable diagnostic instruments\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustment potentiometers simplify field calibration trims\u003c\/li\u003e\n\u003cli\u003eTest Input pin accepts external signal sources for quick verification of current loop output performance\u003c\/li\u003e\n\u003cli\u003eIntegral Power-up Inhibit circuit prevents signal tracking errors caused by initial line voltage transients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluid-film thrust bearing monitoring on small centrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eShaft axial displacement tracking on industrial pumps, motors, and cooling tower fans\u003c\/li\u003e\n\u003cli\u003eCritical machinery protection inside petrochemical refineries and power generation plants\u003c\/li\u003e\n\u003cli\u003eGeneral rotating machinery predictive maintenance setups lacking monitoring rack space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectrical Parameters Value\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e2-wire, loop-powered (12 to 35 VDC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCurrent Loop Output\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e4 to 20 mA DC proportional to thrust position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMaximum Loop Load\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e1,000 ohms at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSystem Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003ePlus or minus 1.5% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eFault Response\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eLess than 3.6 mA in 100 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003ePerformance and Hardware Configuration Value\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFull-Scale Range Option (-06)\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0.6-0-0.6 mm (±0.6 mm \/ 25 mils) total thrust movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eCable System Length (-50)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMounting Type Option (-01)\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSensor Input Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3300 NSv proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmental and Mechanical Value\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-35 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-51 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e0 to 100% RH condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e50g conforming to IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eShock Survival\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e100g at 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConnections \/ Interfaces\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eTerminal \/ Connector Pin Function\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e+4-20mA\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePositive loop power supply input and current transmission terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-4-20mA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNegative loop power supply return connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePROX OUT\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eCoaxial\/terminal signal output for unisolated dynamic diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCommon circuit reference return for diagnostic instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eTEST IN\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eTest pin interface for function generator or variable DC verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eMiniature female socket matching the 3300 NSv extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the device onto a standard 35 mm DIN rail assembly or bolt using optional hardware within a weatherproof panel enclosure.\u003c\/li\u003e\n\u003cli\u003eRoute the loop current conductors through dedicated conduit paths separate from high-current AC motor leads or switching control wires to protect against EMI.\u003c\/li\u003e\n\u003cli\u003eSeal all coaxial connections between the 3300 NSv proximity probe, extension cable, and transmitter terminal socket with self-fusing tape to prevent moisture infiltration.\u003c\/li\u003e\n\u003cli\u003eAvoid structural connection adjustments to the zero and span potentiometers until the proximity probe tip clearance has been set to the proper physical gap.\u003c\/li\u003e\n\u003cli\u003eUse an isolated test instrument or a matching Bently Nevada test adapter when connecting AC-powered oscilloscopes to the PROX OUT and COM terminals to protect loop signaling integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompliance and Certifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mechanical movement does the Bently Nevada 991-06-50-01-05 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures the axial thrust or displacement of a rotating machinery shaft rather than radial casing vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a standalone Proximitor driver unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it features a built-in Proximitor sensor that processes proximity probe eddy-current fields directly within the transmitter module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific cable length is this transmitter calibrated to support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -50 option specifies that the transmitter is calibrated to match a 5.0-meter proximity probe and extension cable system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the full-scale range defined by the -06 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe full-scale measurement limits are 0.6-0-0.6 mm, providing an aggregate scale of ±0.6 mm of shaft axial travel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect an AC-powered oscilloscope directly to the PROX OUT pin?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the dynamic PROX OUT terminal is not isolated from the 4 to 20 mA power loop, using an external signal isolation adapter is highly recommended to protect against signal interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensor is electrically matched with this thrust transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is built exclusively to read signals from a Bently Nevada 3300 NSv proximity probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Power-up Inhibit feature protect the control room loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt mutes erroneous transient output currents during startup spikes to prevent false alarms or safety trips in the connected DCS or PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of mounting method does this unit feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -01 option provides integral 35 mm DIN rail mounting clips for immediate standard rail installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit operate in high-humidity machinery environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is built with fully potted electronic assemblies and certified up to 100% condensing humidity when coaxial connections are properly protected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the -05 configuration suffix represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -05 code designates a specific multi-certification agency approval package, including ATEX, CSA, and ABS Marine ratings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746274155,"sku":"991-06-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-06-50-01-05-vibration-transmitter-bh34x4ouvy4_82ac7102-9bd7-4cad-8aff-31c08d8a50e3.jpg?v=1765446945"},{"product_id":"bently-nevada-990-05-50-02-01-vibration-transmitter","title":"Bently Nevada 990-05-50-02-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-50-02-01\u003c\/strong\u003e provides continuous, proportional linear scaling of proximity probe signals into a simplified two-wire loop architecture. Engineered to serve industrial plant operators looking to streamline monitoring on high-speed assets, this compact component interfaces directly with standard machinery control infrastructure where basic alarm limits and process monitoring calculations are performed. By translating physical shaft movement into a standard analog format, it bridges the gap between field-level eddy current measurements and plant-wide control loops.\u003c\/p\u003e\n\u003cp\u003eConstructed using a ruggedized, fully encapsulated potting compound, the unit functions safely when exposed to severe moisture, shifting temperatures, and airborne industrial contaminants. The system operates out of a single combined module housing, removing traditional multi-component panel steps and lowering the total hardware footings required inside remote field enclosures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombined Signal Processing Housing:\u003c\/strong\u003e Houses the proximity measurement electronics and transmitter circuitry inside a unified enclosure to reduce total component counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaw Signal Accessibility:\u003c\/strong\u003e Provides unfiltered dynamic diagnostic measurements through a dedicated high-frequency coaxial port without altering the primary loop output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-Panel Leveling Potentiometers:\u003c\/strong\u003e Contains uncoupled, non-interacting zero and span trimpots situated safely beneath the environmental overlay label for straightforward device loop adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Output Injection Test Pin:\u003c\/strong\u003e Includes an integrated verification path that allows external frequency signals to validate internal circuit operation and loop tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Alarm Suppression Logic:\u003c\/strong\u003e Uses an intelligent Not OK fault verification system to swiftly drop loop current below 3.6 mA, ensuring field wiring degradation or probe breaks do not induce false trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Humidity Environmental Sealing:\u003c\/strong\u003e Features specialized internal potting that permits full 100% condensing humidity operation without degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Bulkhead Hardware Integration:\u003c\/strong\u003e Comes factory-configured with rugged mounting bolts optimized for direct plate attachment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed centrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eCompact industrial process pumps\u003c\/li\u003e\n\u003cli\u003eMedium and small electric induction motors\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fans and exhaust blower systems\u003c\/li\u003e\n\u003cli\u003eAsset-level plant-wide vibration trending networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Selection Breakdown\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003eBase Vibration Transmitter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-Scale Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils peak-to-peak (0 to 125 micrometers pp) range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Calibrated System Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) total transducer tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Hardware Mounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eBulkhead installation screws configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Safety Agency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2 certified hazardous location option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCore Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eVerified Engineering Parameter Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Input Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 single channel non-contacting 3300 NSv eddy current probe and matching cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc input measured directly at the transmitter wire blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Loop Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-wire configuration supplying 4 to 20 mAdc proportional to peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Error Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% of full-scale across a standard 250 ohm monitoring loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Proximity Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical installation gap between 0.5 and 1.75 mm (20 and 55 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ohms maximum loop resistance threshold at full 35 Vdc input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLimited internally to a maximum of 23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Fail-Safe Action\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput drops below 3.6 mA within 100 microseconds of a probe or connection fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Recovery Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRestores normal analog tracking within 2 to 3 seconds after fault clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower-On Stabilization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrops output below 3.6 mA for 2 to 3 seconds during initial system power ramp-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Port Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm calibrated source impedance configured specifically for a 10 Mohm testing load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Linear Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils) total span beginning 0.25 mm (10 mils) away from target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Factor Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/micrometer (200 mV\/mil) ±6.5% typical based on an AISI 4140 steel target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInherent Noise Floor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV peak-to-peak typical noise level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Drift Deviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale factor remains within ±10% of nominal from 0 degC to +70 degC (+32 degF to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz flat response with +0, -3 dB attenuation curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Profiling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) minimum target surface diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Cable Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10 feet) maximum physical cable distance for the coaxial BNC connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Ambient Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating: -35 degC to +85 degC; Storage: -52 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating and Storage limits rated from -52 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Mass Metrics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmitter Unit: 0.43 kg (0.9 lbm); Total System: 0.82 kg (1.8 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor tip: Polyphenylene sulfide (PPS); Case body: AISI 303 or 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWiring Pin Location\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSystem Terminal Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop Power Supply Positive Input (+) \/ 4 to 20 mA Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop Power Supply Negative Input (-) \/ 4 to 20 mA Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated Proximitor Dynamic Output (PROX OUT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated Proximitor Dynamic Common Reference (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial J2 Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-Facing BNC Dynamic Signal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial J3 Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy Duty Integrated Proximity Probe Input Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection Requirements:\u003c\/strong\u003e Run twisted-pair, shielded 1.0 mm2 (18 AWG) conductors for the primary 4 to 20 mA loop runs. The total length of this field loop wiring path can extend up to a maximum distance of 13 km (8 miles).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Voltage Calculations:\u003c\/strong\u003e Verify field loop resistances do not violate the linear operational boundary formula: RLOOP = 43.5 x (Vps - 12). If total resistance exceeds this computed maximum, the transmitter cannot reach full-scale 20 mA transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Port Phase Orientation:\u003c\/strong\u003e Note that the dynamic voltage signal supplied at the PROX OUT coaxial port is 180 degrees inverted relative to standard Bently Nevada instrumentation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Loop Protection:\u003c\/strong\u003e Do not interface standard mains-powered or non-isolated AC diagnostic instruments directly to the raw PROX OUT ports. Use the 122115-01 Test Adapter to introduce necessary isolation and maintain plant safety integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Coupling Restrictions:\u003c\/strong\u003e Ensure mechanical probe casings do not cross the absolute thread engagement maximum profiles (12 mm for M8x1 and 15 mm for M10x1) to eliminate permanent thread binding risks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC Rules Enforcement:\u003c\/strong\u003e Verified under Part 15 of standard FCC interference regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial EMC Performance:\u003c\/strong\u003e Certified to EN 61000-6-2, EN 61000-6-4, and the general EMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosive Atmosphere Directives:\u003c\/strong\u003e Compliant with ATEX Directive 2014\/34\/EU and RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Lifecycle Compliance:\u003c\/strong\u003e China RoHS 15-Year Environment Friendly Use Period (EFUP) specification under SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Type Approvals:\u003c\/strong\u003e Certified under ABS 2009 Steel Vessels Rules criteria\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Safety Marking:\u003c\/strong\u003e cNRTLus certified for Class I, Division 2, Groups A, B, C, and D hazardous fields (T5 @ Ta = +85 degC, Type 4 rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational ATEX\/IECEx Classification:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eII 1 G Ex ia IIC T4 Ga (T4 rating with Ta operational window of -30 degC to +85 degC)\u003c\/li\u003e\n\u003cli\u003eII 3 G Ex ec IIC T4 Gc (T4 rating with Ta operational window of -30 degC to +85 degC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the practical consequence of exceeding the maximum calculated loop resistance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the circuit resistance exceeds the limit defined by the supply voltage formula, the system runs out of electrical headroom. As a result, the loop current becomes clamped and fails to reach the 20 mA full-scale limit during high vibration events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the analog loop current read under 3.6 mA immediately after applying power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an automated power-up inhibit cycle that runs for 2 to 3 seconds. It holds the transmitter in a Not OK state to let internal circuits stabilize, preventing initial electrical switch-on spikes from being misread as vibration trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the integrated signal defeat logic handle a broken extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter recognizes the open circuit as a Not OK condition and immediately drops the analog loop current below 3.6 mA within 100 microseconds. This rapid drop alerts the attached PLC or DCS that the measurement channel has failed rather than reporting an actual machine over-vibration event.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan standard diagnostic instruments be hooked directly up to the BNC terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly battery-powered or fully floating diagnostic instruments should be attached to the non-isolated PROX OUT port. Grounded, AC-powered instruments require the 122115-01 signal isolation adapter to prevent ground loops that could trigger false alarms on the loop network.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746437995,"sku":"990-05-50-02-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-50-02-01-vibration-transmitter-dhn50edof3l_2202303d-6031-43f4-b352-3c8d2644e6c3.jpg?v=1765446950"},{"product_id":"bently-nevada-991-25-50-01-01-991-thrust-transmitter","title":"Bently Nevada 991-25-50-01-01 991 Thrust Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 991-25-50-01-01\u003c\/strong\u003e is a two-wire, loop-powered \u003cstrong\u003ethrust transmitter\u003c\/strong\u003e designed to measure the relative axial position of a rotating machine shaft. It accepts input directly from a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and extension cable, transforming the proximity signal into a proportional 4 to 20 mA current output. This device integrates directly with Programmable Logic Controllers (PLCs), Distributed Control Systems (DCSs), and SCADA networks to provide continuous machinery protection and condition monitoring. Typical industrial applications include centrifugal air compressors, small pumps, motors, and fans with fluid-film thrust bearings where a full machinery protection system monitor rack is not required.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire, 4 to 20 mA loop-powered current output\u003c\/li\u003e\n\u003cli\u003eDesigned for non-contacting shaft axial displacement measurement\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and extension cable\u003c\/li\u003e\n\u003cli\u003eIntegrated BNC connector for dynamic vibration signal access and diagnostics\u003c\/li\u003e\n\u003cli\u003eDIN rail or panel mounting configurations\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustments\u003c\/li\u003e\n\u003cli\u003ePotted construction for high humidity environments up to 100% condensing\u003c\/li\u003e\n\u003cli\u003eNot OK\/Signal Defeat circuit to prevent false alarms due to faulty proximity probes or loose connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eProcess pumps and industrial motors\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eElectric motors with thrust bearings\u003c\/li\u003e\n\u003cli\u003eCooling tower fans and blowers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e991\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale Option: 25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option: 5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: 35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm (2.10 in x 2.91 in x 3.94 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBody Height (without DIN clip)\u003c\/td\u003e\n\u003ctd\u003e42.6 mm (1.68 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMounting Hole Distance (Width x Length)\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm (2.50 in x 2.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm (0.23 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 35 Vdc (at the transmitter terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA (Linear over 50 mils range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% over specified full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohms including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBNC Connector Output\u003c\/td\u003e\n\u003ctd\u003eRaw proximity probe voltage buffered (Nominal 200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 to +85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +100 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Input Terminal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal Common \/ System Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+4-20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Loop Power \/ Current Output Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4-20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Loop Power \/ Current Output Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic Signal Output (Buffered Proximity Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eDimensions and Mounting\u003c\/h3\u003e\n\u003cp\u003eThe module accommodates both panel (bulkhead) and DIN rail mounting options. When using the panel mount configuration, prepare four mounting holes with a spacing layout of 63.5 mm (width) by 69.9 mm (length). Use the standard 5.8 mm diameter mounting holes or the supplied 6-32 x 1.326 screws for secure bulkhead fixation. For DIN rail configurations, ensure a standard 35 mm DIN rail is rigidly installed before snapping on the transmitter's DIN mount clips.\u003c\/p\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eProper grounding is essential to minimize noise interference. The transmitter must be mounted to a grounded plate or a grounded DIN rail. Ensure the cable shield is grounded at only one end, typically at the control room\/DCS side, to prevent ground loops.\u003c\/p\u003e\n\u003ch3\u003eProbe Gap Adjustment\u003c\/h3\u003e\n\u003cp\u003eBefore final commissioning, the proximity probe must be physically positioned (gapped) relative to the shaft target. Adjust the gap until the transmitter output reads approximately 12 mA, which corresponds to the midpoint of the linear thrust range (0 mils).\u003c\/p\u003e\n\u003ch3\u003eCable Routing\u003c\/h3\u003e\n\u003cp\u003eRun probe and loop cables in dedicated, grounded metal conduits or cable trays. Avoid routing transmitter cables parallel to high-voltage AC power lines or heavy machinery switching circuits to prevent electro-magnetic interference (EMI).\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Precautions\u003c\/h3\u003e\n\u003cp\u003eWhen installed in classified areas, appropriate intrinsic safety barriers or explosion-proof housings must be utilized in accordance with local electrical codes and the specific installation drawings provided by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of this thrust transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures the axial displacement or thrust position of a rotating machine shaft relative to a fixed reference point using a non-contacting proximity probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of probe system is compatible with this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed specifically to interface with a Bently Nevada 3300 NSv proximity probe and extension cable system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the device powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a loop-powered device operating on a 12 to 35 Vdc supply connected via the 4 to 20 mA current loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the BNC connector provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BNC connector provides a buffered raw voltage signal proportional to the probe gap distance, allowing engineers to connect diagnostic equipment like oscilloscopes or analyzers without disconnecting the loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this device be used for radial vibration measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific model is configured and calibrated for thrust (axial) position measurement. For radial vibration, a 990 Vibration Transmitter should be used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the Not OK\/Signal Defeat circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe circuit forces the signal output to drop below 3.6 mA within 100 microseconds of a probe fault or loose connection to prevent false alarms in the control system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746962283,"sku":"991-25-50-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-50-01-01-thrust-transmitter-apzkr42z0zt_98ab5da5-7e2f-4c22-ba5c-ac12cefa8949.jpg?v=1765446967"},{"product_id":"bently-nevada-990-05-50-01-01-990-series-vibration-transmitter","title":"Bently Nevada 990-05-50-01-01 990 Series Vibration Transmitter","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-50-01-01\u003c\/strong\u003e is a two-wire, loop-powered vibration transmitter designed primarily for original equipment manufacturers (OEMs) of centrifugal air compressors, small pumps, motors, or fans. This device accepts an input signal from a non-contacting \u003cstrong\u003e3300 NSv\u003c\/strong\u003e proximity probe and its matching extension cable. It conditions the incoming transducer signal into appropriate peak-to-peak vibration amplitude engineering units and provides a proportional 4 to 20 mA industry-standard output signal directly to a machinery control system where alarm logic and protection processes occur.\u003c\/p\u003e\n\u003cp\u003eEquipped with an integrated \u003cstrong\u003eProximitor\u003c\/strong\u003e sensor, the \u003cstrong\u003e990-05-50-01-01\u003c\/strong\u003e eliminates the requirement for an external standalone proximitor unit, reducing cabinet footprint. The encapsulated potted construction makes it highly reliable in harsh, high-humidity environments. For auxiliary diagnostic purposes, the unit includes non-isolated \u003cstrong\u003ePROX OUT\u003c\/strong\u003e and \u003cstrong\u003eCOM\u003c\/strong\u003e terminals along with a coaxial connector to supply dynamic vibration data and gap voltage outputs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor:\u003c\/strong\u003e Combines the electronics within the transmitter casing, requiring no additional separate processing units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Diagnostic Outputs:\u003c\/strong\u003e Features non-isolated PROX OUT and COM terminals alongside a coaxial connector to deliver unfiltered dynamic vibration and gap voltage measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Calibration:\u003c\/strong\u003e Includes non-interacting zero and span potentiometers beneath the primary label to support effortless field loop adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Loop Verification:\u003c\/strong\u003e Integrates a Test Input pin allowing rapid validation of loop signal outputs via a function generator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot OK \/ Signal Defeat Circuitry:\u003c\/strong\u003e Intercepts faulty inputs from loose connections or damaged proximity probes to immediately suppress false alarms by dropping the loop signal below 3.6 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotted Casing Construction:\u003c\/strong\u003e Optimized for high-humidity deployment up to 100% condensing environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Mounting Hardware:\u003c\/strong\u003e Supports standard choice of 35 mm DIN-rail clips or bulkhead mounting configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial small pumps\u003c\/li\u003e\n\u003cli\u003eElectric motors\u003c\/li\u003e\n\u003cli\u003eCooling and ventilation fans\u003c\/li\u003e\n\u003cli\u003eRotating machinery overall vibration trending\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Selection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 micrometers pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2 regulatory approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires +12 to +35 Vdc input at the transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc over specified full-scale range in 2-wire configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4 to 20 mA Loop Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% over specified full-scale range (rated from TEST signal input to voltage across a 250 ohm loop resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Probe Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGapped between 0.5 and 1.75 mm (20 and 55 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ohm including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Adjustments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-interacting external zero and span adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNOT OK \/ Signal Defeat Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput drops to less than 3.6 mA within 100 microseconds after Not OK; restores within 2-3 seconds after removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower-up Inhibit Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStays at less than 3.6 mA for 2 to 3 seconds after power application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm output impedance calibrated for a 10 Mohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils); begins at approximately 0.25 mm (10 mils) from target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Incremental Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/micrometer (200 mV\/mil) ±6.5% typical over linear range; worst case ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Typical Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScale factor remains within ±10% of 7.87 mV\/micrometer from 0 degC to +70 degC (+32 degF to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz +0, -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Coaxial Cable Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum cable distance is 3 meters (10 feet) for Proximitor Sensor BNC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Storage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Operating\/Storage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged, with protection of coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block \/ Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply (+) \/ 4-20 mA Loop Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply (-) \/ 4-20 mA Loop Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Dynamic Output \/ Terminal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Dynamic Common \/ Terminal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ2 (Coaxial)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic Vibration \u0026amp; Gap Voltage Output (PROX OUT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ3 (Connector)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Input Terminal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Specifications:\u003c\/strong\u003e Use standard 2-conductor, twisted, shielded 1.0 mm2 (18 AWG) cable (part number 02173006) for loop wiring and terminal-strip PROX OUT runs. Maximum acceptable loop wire path length is 13 km (8 miles).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Resistance Restrictions:\u003c\/strong\u003e Ensure that the total loop resistance satisfies the mechanical formulation: RLOOP = 43.5 x (Vps - 12) ohms. Exceeding the maximum resistance region limits full-scale current outputs below 20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROX OUT Phasing \u0026amp; Isolation:\u003c\/strong\u003e The phase of the PROX OUT raw diagnostic output signal is natively inverted compared to standard Bently Nevada outputs. Never directly connect grounded AC-powered diagnostic gear to the PROX OUT port to protect against false trip conditions. Use the specialized 122115-01 Test Adapter to introduce necessary dynamic voltage inversion and signal isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Grounding and Shielding:\u003c\/strong\u003e Terminate cable shields safely at the instrumentation common end to mitigate severe EMI\/RFI noise pickup. Verify probe coaxial cables are protected from industrial moisture intrusion via connector protectors or fluorosilicone boots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement Boundaries:\u003c\/strong\u003e Strictly respect nominal installation torque and maximum thread engagement lengths (12 mm for M8x1, 15 mm for M10x1) to avoid mechanical binding or physical housing failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e EN 61000-6-2, EN 61000-6-4, EMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Directive:\u003c\/strong\u003e 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU, China RoHS 15-year EFUP (SJ\/T 11364-2024)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e ABS 2009 Steel Vessels Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Approvals:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, D (T5 @ Ta = +85 degC, Type 4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area ATEX\/IECEx Ratings:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eII 1 G Ex ia IIC T4 Ga (T4 @ Ta = -30 degC to +85 degC)\u003c\/li\u003e\n\u003cli\u003eII 3 G Ex ec IIC T4 Gc (T4 @ Ta = -30 degC to +85 degC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the Not OK\/Signal Defeat circuit on the transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe circuit detects internal or environmental faults such as broken proximity probe hardware or unsecured cable interfaces. When an issue occurs, it rapidly forces the loop output current down to less than 3.6 mA within 100 microseconds, suppressing downstream false protection triggers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan a standard oscilloscope be attached directly to the coaxial output plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDirectly connecting mains-powered, grounded AC diagnostic test gear to the raw PROX OUT BNC or terminal strip can create ground loops and generate false alarms. For safe dynamic diagnostic analysis, a 122115-01 Test Adapter is required to correctly invert and isolate the signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply range is required for standard 2-wire loop operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device operates on a 2-wire transmitter network and requires a DC supply voltage input between +12 Vdc and +35 Vdc measured right across the terminal blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the power-up inhibit feature behave during system startup sequences?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUpon receiving loop power, the device forces its output signal to drop below 3.6 mA for a duration of 2 to 3 seconds. This initialization delay keeps the machinery control logic from confusing startup power transients with valid over-vibration signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666754040171,"sku":"990-05-50-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-50-01-01-vibration-transmitter-qn5uinaqimo_67d12540-3a46-4016-93f8-17cf0f5fec84.jpg?v=1765447016"},{"product_id":"bently-nevada-990-10-xx-01-05-mod-163930-01-vibration-transmitter","title":"Bently Nevada 990-10-XX-01-05 MOD: 163930-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-10-XX-01-05 MOD: 163930-01\u003c\/strong\u003e is a loop-powered 2-wire vibration transmitter engineered to process raw signals from proximity probe systems and output a proportional 4-20 mA analog current loop directly to control architectures. This integration eliminates the need for separate proximitor sensors and centralized monitor racks, allowing for a simplified machinery protection interface on compact rotating assets. The device monitors peak-to-peak casing or shaft vibration to safeguard original equipment manufacturer (OEM) packages against mechanical faults. Optimized for confined physical spaces, the system utilizes specialized narrow-profile transducers to deliver reliable dynamic measurements. The \u003cstrong\u003eMOD: 163930-01\u003c\/strong\u003e designation indicates a specific factory modification tailored to adjust internal circuit gain, tune frequency response curves, or match the input impedance requirements of targeted industrial control loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated proximitor and transmitter functionality within a single potted enclosure.\u003c\/li\u003e\n\u003cli\u003eDirectly outputs a 4-20 mA DC signal proportional to overall vibration displacement.\u003c\/li\u003e\n\u003cli\u003eDedicated non-isolated dynamic signal terminals (PROX OUT and COM) for field analysis.\u003c\/li\u003e\n\u003cli\u003eNot OK \/ Signal Defeat circuitry to prevent erroneous control system trips during sensor faults.\u003c\/li\u003e\n\u003cli\u003eFully encapsulated electronics providing resistance to 100% condensing humidity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOEM centrifugal air compressor protection packages.\u003c\/li\u003e\n\u003cli\u003eSmall industrial pump vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eElectric motor shaft displacement tracking.\u003c\/li\u003e\n\u003cli\u003eIndustrial cooling fan and blower machinery protection loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-XX-01-05 MOD: 163930-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10 mils peak-to-peak (0-250 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC analog current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated coaxial\/terminal PROX OUT and COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clip mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully potted internal electronics (100% condensing humidity rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mm x 45 mm x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4-20mA (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Loop Power Supply Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4-20mA (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Loop Current Output \/ Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX OUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnisolated Dynamic Voltage Signal Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal Common \/ Ground reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Securely latch the integrated mounting clip onto a standard 35 mm DIN rail inside a dust-tight enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Noise Suppression:\u003c\/strong\u003e Connect the cable shield wires to the instrument ground at the PLC\/DCS cabinet only. Maintain shield continuity through any intermediate junction boxes without grounding the shield locally at the transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Gap Adjustment:\u003c\/strong\u003e Follow standard engineering procedures to adjust the initial mechanical gap of the 3300 NSv probe using the dynamic voltage output from the PROX OUT terminal prior to finalizing installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit and Cable Routing:\u003c\/strong\u003e Separate field wiring from high-power electrical cabling to mitigate electromagnetic interference that can distort the low-level transmitter inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA Division 2\u003c\/li\u003e\n\u003cli\u003eATEX Zone 0 \/ Zone 2\u003c\/li\u003e\n\u003cli\u003eABS Marine Type Approval\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666763051371,"sku":"990-10-XX-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-xx-01-05-mod-163930-01-vibration-transmitter-dydkzrpq2dc_11cadf60-001c-4dad-8c64-bc0d097c2891.jpg?v=1765447159"},{"product_id":"bently-nevada-990-10-50-01-05-990-vibration-transmitter","title":"Bently Nevada 990-10-50-01-05 990 Vibration Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003e990-10-50-01-05\u003c\/strong\u003e is a two-wire, loop-powered vibration transmitter designed to provide a simple 4 to 20 mA proportional vibration signal directly to a machinery control system. This \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e integrates a Proximitor Sensor into a single unit, accepting input from a 3300 NSv proximity probe and its matching extension cable. It conditions the transducer signal into appropriate peak-to-peak vibration amplitude engineering units, enabling cost-effective machinery protection alarming, logic, and overall vibration trending without requiring an external proximity sensor unit.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Proximitor Sensor eliminates the need for an external housing or separate signal conditioner.\u003c\/li\u003e\n\u003cli\u003eNon-isolated PROX OUT and COM terminals alongside a coaxial connector provide dynamic vibration and gap voltage signal output for diagnostics.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span potentiometers beneath the transmitter label allow easy loop adjustment.\u003c\/li\u003e\n\u003cli\u003eDedicated Test Input pin enables swift verification of the loop signal output via an external function generator.\u003c\/li\u003e\n\u003cli\u003eBuilt-in Not OK\/Signal Defeat circuit prevents false alarms or high loop outputs caused by loose connections or a faulty proximity probe.\u003c\/li\u003e\n\u003cli\u003eDual mounting flexibility with standard options for either 35 mm DIN-rail clips or bulkhead mounting screws.\u003c\/li\u003e\n\u003cli\u003ePotted construction ensures dependable performance in high-humidity environments up to 100% condensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eSmall industrial pumps\u003c\/li\u003e\n\u003cli\u003eElectric motors\u003c\/li\u003e\n\u003cli\u003eIndustrial cooling fans\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003e990: Vibration Transmitter\u003c\/p\u003e\n\u003cp\u003e10: 0-10 mils pp (0-250 um pp) Full-scale Option\u003c\/p\u003e\n\u003cp\u003e50: 5.0 meters (16.4 feet) System Length Option\u003c\/p\u003e\n\u003cp\u003e01: 35 mm DIN rail clips Mounting Option\u003c\/p\u003e\n\u003cp\u003e05: CSA Division 2, ATEX Zone 0, ATEX Zone 2 and includes ABS maritime approval Agency Approval Option\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-50-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc input at the transmitter terminal (28 Vdc for Hazardous locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc over specified full-scale range in 2-wire configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin +-1.5% over specified full-scale range across a 250 Ohm loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 Ohm including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Limiting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Gap Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 1.75 mm (20 to 55 mils) from target to ensure full scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils), starting at approx 0.25 mm (10 mils) from target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/um (200 mV\/mil) +-6.5% typical; worst case +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz +0, -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNot OK \/ Signal Defeat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput drops to less than 3.6 mA within 100 us of fault; restores in 2-3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower-up Inhibit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput held at less than 3.6 mA for 2 to 3 seconds after power application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProx Out Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm output impedance calibrated for a 10 MOhm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) diameter AISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10 feet) for Proximitor Sensor Output (BNC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Transmitter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 to +85 Celsius (-31 to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature (Transmitter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +100 Celsius (-62 to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\/Storage Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 to +177 Celsius (-62 to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged (with coaxial connector protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e222 N (50 lbf) probe case to probe lead, maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX OUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated dynamic vibration and gap voltage signal (BNC\/Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon reference terminal for loop power and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive loop power input (+12 to +35 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative loop power return \/ 4-20 mA current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTEST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Input pin for external function generator signal verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Jack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect connection to the 3300 NSv matching extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eProbe Gap Adjustment\u003c\/h3\u003e\n\u003cp\u003eThe proximity probe must be mechanically gapped between 0.5 and 1.75 mm (20 and 55 mils) from the target surface during installation. This ensures that the probe operates entirely within its linear range and allows the transmitter to accurately generate the full-scale 4 to 20 mA output.\u003c\/p\u003e\n\u003ch3\u003eThread Engagement Limits\u003c\/h3\u003e\n\u003cp\u003eWhen installing the probe into a threaded mounting hole, do not exceed the industry-standard maximum thread engagement length of 1.5 times the nominal thread diameter. For a 1\/4-28 thread, maximum engagement is 0.375 in; for M8x1, it is 12 mm. Exceeding these limits can cause mechanical binding and voids the warranty. For 1\/4-28 probes, a #3 or larger tap drill is recommended.\u003c\/p\u003e\n\u003ch3\u003eSignal Isolation and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe PROX OUT coaxial connector provides a dynamic transducer signal for diagnostics but is not isolated from the 4 to 20 mA loop. While it can connect directly to isolated, battery-powered test equipment, using an external test adapter (such as the 990\/991 Test Adapter) is strongly recommended when connecting to AC-powered equipment like oscilloscopes. This preserves loop isolation and prevents false alarms or loop degradation.\u003c\/p\u003e\n\u003ch3\u003eMoisture Protection\u003c\/h3\u003e\n\u003cp\u003eThe transmitter features a potted construction rated for up to 100% condensing humidity. However, the coaxial connectors on the probe and extension cable must be physically protected against fluid ingress to maintain calibration and signal integrity.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Division 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Zone 0, Zone 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine:\u003c\/strong\u003e ABS maritime approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 4 to 20 mA loop output be used to analyze vibration phase or establish gap alarms?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 4 to 20 mA loop output provides only overall peak-to-peak vibration amplitude data. It cannot capture vibration phase or support advanced monitoring features such as gap alarms, phase alarms, Danger Bypass, or Trip Multiply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the loop output if the proximity probe cable is disconnected or cut?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter features a Not OK\/Signal Defeat circuit. If a fault or loose connection occurs, the loop signal drops to less than 3.6 mA within 100 microseconds to prevent high outputs or false machinery alarms. It restores within 2 to 3 seconds once the fault condition is resolved.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external Proximitor sensor needed when ordering this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The unit features a fully integrated Proximitor sensor inside the transmitter housing. It connects directly to the 3300 NSv probe extension cable without needing an intermediary signal conditioner.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666769703275,"sku":"990-10-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-50-01-05-990-vibration-transmitter-szxyhyku41t_b40d044d-afe4-4e90-9a27-c5eb4e1db6b8.jpg?v=1765447266"},{"product_id":"bently-nevada-990-05-xx-01-cn-mod-165335-01-990-vibration-transmitter","title":"Bently Nevada 990-05-XX-01-CN MOD: 165335-01 | 990 Vibration Transmitter","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/strong\u003e is a high-reliability, two-wire \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e to supply continuous machinery protection monitoring directly to plant control networks. This industrial component integrates the processing circuitry of a standard proximity sensor into a compact field-mount transmitter package. It accepts inputs from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable, processing raw high-frequency micro-gap changes into a linear, proportional 4 to 20 mA current output loop. This analog signal interfaces directly with standard Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), or simple process data recorders without requiring a separate rack system monitor.\u003c\/p\u003e\n\u003cp\u003eThis precise hardware configuration features a factory-calibrated \u003cstrong\u003efull-scale measurement option of 0-5 mils pp (0-125 um pp)\u003c\/strong\u003e, designed for direct tracking of radial shaft vibration amplitudes. The physical casing comes integrated with \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e to allow fast, secure snap-on mounting into field marshalling junctions. This variant is engineered with the \u003cstrong\u003eCN agency option\u003c\/strong\u003e, which provides global and local industrial compliance covering ATEX\/IECEx and Chinese NEPSI hazardous area safety certifications. The assignment \u003cstrong\u003eMOD: 165335-01\u003c\/strong\u003e designates a specialized factory modification code that ensures specific internal processing tweaks or precise component matching parameters tailored to targeted machinery requirements while preserving full base-model compatibility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire loop-powered architecture providing direct 4 to 20 mA analog output integration into host PLC or DCS loops.\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated full-scale range measuring 0-5 mils peak-to-peak (0-125 um peak-to-peak) for high-accuracy shaft vibration logging.\u003c\/li\u003e\n\u003cli\u003eIntegral 35 mm DIN rail mounting clips allowing rapid, toolless snap-fit structural deployment on enclosure racks.\u003c\/li\u003e\n\u003cli\u003eRobust hazardous area safety design certified with combined ATEX\/IECEx and local Chinese NEPSI industrial markings.\u003c\/li\u003e\n\u003cli\u003eDedicated factory configuration label designated under MOD: 165335-01 for precise system architecture synchronization.\u003c\/li\u003e\n\u003cli\u003eOnboard BNC buffered output connector providing unconditioned dynamic eddy-current waveforms for local machinery diagnostics.\u003c\/li\u003e\n\u003cli\u003eBuilt-in non-interacting zero and span adjustments allowing clean precision calibration touch-ups under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect radial vibration tracking on fluid-filmed bearings of industrial centrifugal air compressors and process fans.\u003c\/li\u003e\n\u003cli\u003eContinuous asset health processing loop monitoring on medium-sized balance-of-plant electric motor or pump skids.\u003c\/li\u003e\n\u003cli\u003eDistributed, standalone field instrumentation integration on specialized gas or water utility infrastructure pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils peak-to-peak (0-125 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length option (Matches probe\/cable design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCombined ATEX\/IECEx and Chinese NEPSI hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD: 165335-01\u003c\/td\u003e\n\u003ctd\u003eSpecialized factory configuration modification designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils pp (0 to 125 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signaling Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear 4 to 20 mAdc proportional current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to the probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Connector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePin terminals accepting wire cross-sections up to 1.5 mm squares\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Framework Build\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure with integrated aluminum mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing exposure boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial port linking to the incoming proximity transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive loop terminal interface receiving incoming +12 to +35 Vdc power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated front coaxial BNC socket providing unconditioned voltage waveforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Alignment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter plate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666849034603,"sku":"990-05-XX-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-xx-01-cn-vibration-transmitter-e1zi1lxp55q_5212f2cd-b252-4be2-9040-fdde7be189e4.jpg?v=1765449005"},{"product_id":"bently-nevada-990-05-70-02-00-vibration-transmitter","title":"Bently Nevada 990-05-70-02-00 Vibration Transmitter","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-05-70-02-00\u003c\/strong\u003e is a two-wire, loop-powered \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e designed to process signals from proximity probes into a proportional 4 to 20 mA industry-standard current loop. The device directly interfaces with a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and its matching extension cable to monitor peak-to-peak vibration amplitude. This transmitter provides an engineered solution for machinery control systems where local control-level protection alarming and logic are required. It operates as an integrated Proximitor Sensor unit, optimizing signal processing for compact industrial equipment.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Proximitor Sensor requires no external driver unit.\u003c\/li\u003e\n\u003cli\u003eNon-isolated PROX OUT and COM terminals plus a coaxial connector deliver dynamic vibration and gap voltage signals.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span potentiometers enable straightforward calibration and loop adjustment.\u003c\/li\u003e\n\u003cli\u003eTest Input pin permits direct verification of the loop output using an external function generator.\u003c\/li\u003e\n\u003cli\u003eNot OK\/Signal Defeat circuit quickly drops output below 3.6 mA to suppress false alarms during probe faults.\u003c\/li\u003e\n\u003cli\u003ePotted construction provides robust environmental protection for high-humidity installations.\u003c\/li\u003e\n\u003cli\u003eCompact design supports installation in confined spaces with minimal clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eSmall pumps and fluid machinery\u003c\/li\u003e\n\u003cli\u003eIndustrial electric motors\u003c\/li\u003e\n\u003cli\u003eCooling and ventilation fans\u003c\/li\u003e\n\u003cli\u003eOEM machinery control system integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eField Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA: Full-scale Option\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB: System Length Option\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC: Mounting Option\u003c\/td\u003e\n\u003ctd\u003eBulkhead screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: Agency Approval Option\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-70-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc input at the transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc over specified full-scale range (2-wire configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA Loop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1.5% over specified full-scale range across 250 Ohm resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ohm including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZero and Span\u003c\/td\u003e\n\u003ctd\u003eNon-interacting external adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNOT OK\/Signal Defeat\u003c\/td\u003e\n\u003ctd\u003eSignal output \u0026lt; 3.6 mA within 100 us of fault; restores in 2-3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower-up Inhibit\u003c\/td\u003e\n\u003ctd\u003eSignal output \u0026lt; 3.6 mA for 2 to 3 seconds after power application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx Out Linear Range\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils), begins approx. 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProx Out Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/um (200 mV\/mil) +\/-6.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003eScale factor remains within +\/-10% of 7.87 mV\/um from 0 Celsius to +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz +0, -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in) diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmitter Operating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 Celsius to +85 Celsius (-31 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransmitter Storage Temp\u003c\/td\u003e\n\u003ctd\u003e-52 Celsius to +100 Celsius (-62 Fahrenheit to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProbe Operating\/Storage Temp\u003c\/td\u003e\n\u003ctd\u003e-52 Celsius to +177 Celsius (-62 Fahrenheit to +351 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged (with coaxial connector protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransducer Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc Loop Power Input and 4-20 mA Signal Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROX OUT Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated dynamic transducer signal for local diagnostic connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon reference point for signal verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC connection for dynamic vibration and gap voltage monitoring (Max 3m distance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Input Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal injection point for verifying loop response via a function generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eProbe Gap Adjustment\u003c\/h3\u003e\n\u003cp\u003eThe proximity probe must be physically gapped between 0.5 and 1.75 mm (20 and 55 mils) from the target surface. This ensures the target remains inside the transmitter's linear measurement range during machine operation.\u003c\/p\u003e\n\u003ch3\u003eThread Engagement Limits\u003c\/h3\u003e\n\u003cp\u003eDo not exceed the maximum thread engagement lengths during installation to avoid component binding. For 1\/4-28 threads, the limit is 0.375 inches; for M8x1 threads, the limit is 12 mm. Bently Nevada does not cover warranty replacements for probes damaged by excessive thread engagement.\u003c\/p\u003e\n\u003ch3\u003eMoisture Protection\u003c\/h3\u003e\n\u003cp\u003eThe unit utilizes potted construction suitable for up to 100% condensing humidity. To maintain loop integrity, all coaxial connectors must be protected against direct moisture ingress using appropriate sealing boots or enclosures.\u003c\/p\u003e\n\u003ch3\u003eSignal Isolation and Test Adapters\u003c\/h3\u003e\n\u003cp\u003eThe PROX OUT coaxial connector is non-isolated from the 4 to 20 mA loop circuit. While compatible with ungrounded, portable test equipment, you must use a 122115-01 or 990\/991 Test Adapter when connecting to grounded, ac-powered test equipment like oscilloscopes to isolate the loops and maintain safety integrity.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat limitations do vibration transmitters have compared to standard machinery protection monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransmitters provide peak-to-peak trending data only and cannot capture dynamic waveforms during an alarm event. They do not support phase tracking, gap alarms, Timed OK channel defeat, Danger Bypass, or Trip Multiply, and they cannot interface with plant-wide diagnostic platforms like System 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Not OK circuit manage loose sensor connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf a probe connection loosens or fails, the transmitter drops the loop output below 3.6 mA within 100 microseconds. Once the connection is secure, the transmitter waits 2 to 3 seconds before restoring the standard output signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size target is required for the transmitter to meet its accuracy specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe target must have a minimum diameter of 9.5 mm (0.375 inches) and be composed of AISI 4140 steel to maintain the calibrated scale factor.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666849362283,"sku":"990-05-70-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-02-00-vibration-transmitter-dzqdke2pxtm_6cabc840-bf2b-46c8-9c16-0efd97486b2a.jpg?v=1765449009"},{"product_id":"bently-nevada-990-08-xx-01-00-mod-165353-01-2-wire-vibration-transmitter","title":"Bently Nevada 990-08-XX-01-00 MOD: 165353-01 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-08-XX-01-00\u003c\/strong\u003e, bearing modification code \u003cstrong\u003eMOD: 165353-01\u003c\/strong\u003e, is a 2-wire vibration transmitter engineered for continuous machine asset condition tracking and monitoring. This microprocessor-driven microprocessor-compatible industrial instrument converts a signal from a proximity probe into a proportional loop-powered current output, enabling direct integration into plant management machinery controllers without standalone monitoring monitors. The device features an architecture specialized for basic non-contacting vibration sensing, extracting structural displacement and dynamic motion trends directly from target machinery components. Equipped with standard integrated mounting brackets, it allows simple control panel integration within localized termination enclosures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizes a highly efficient loop-powered 2-wire transmitter configuration.\u003c\/li\u003e\n\u003cli\u003eIntegrated structural modification variant designated under code MOD: 165353-01.\u003c\/li\u003e\n\u003cli\u003eEngineered directly for non-contacting proximity probe sensor interfaces.\u003c\/li\u003e\n\u003cli\u003eBuilt-in industrial mechanical frame features 35 mm DIN rail clips for quick installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous vibration tracking and shaft displacement monitoring on heavy industrial rotating machinery.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery monitoring and sensor loop protection integration across factory networks.\u003c\/li\u003e\n\u003cli\u003eControl cabinet installations requiring localized process signals and hardwired loop outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-08-XX-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD: 165353-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (U.S.A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign and snap the transmitter housing firmly onto a standard industrial 35 mm DIN rail inside an electrical equipment enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect the field proximity sensor wiring to the input terminal points on the device housing shell, adhering to correct technical pin mapping layouts.\u003c\/li\u003e\n\u003cli\u003eAttach the external 2-wire loop cables to the designated termination blocks, confirming precise power supply voltage polarity before energizing the system loop.\u003c\/li\u003e\n\u003cli\u003eRoute all critical signal paths separate from heavy electrical primary power lines to prevent field noise coupling or transient signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852606315,"sku":"990-08-XX-01-00 MOD:165353-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-08-xx-01-00-mod-165353-01-vibration-transmitter-gt3kgufzga1_ca579635-0e5d-4f16-a9d8-0437c5a86af1.jpg?v=1765449090"},{"product_id":"bently-nevada-990-04-50-02-00-2-wire-vibration-transmitter","title":"Bently Nevada 990-04-50-02-00 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-04-50-02-00\u003c\/strong\u003e is a compact loop-powered vibration transmitter used to convert proximity probe displacement into a standard 4 to 20 mA signal for industrial monitoring systems. It is designed for applications where vibration data is required for continuous trend observation and basic protection logic rather than full waveform diagnostics.\u003c\/p\u003e\n\u003cp\u003eThis version uses a \u003cstrong\u003ebulkhead screw mounting arrangement\u003c\/strong\u003e, which is often preferred in control panel designs where direct enclosure mounting is required. In practice, engineers choose this type when they want a rigid installation point that reduces mechanical movement and simplifies wiring routing inside tight cabinets.\u003c\/p\u003e\n\u003cp\u003eThe device operates with a 3300 NSv proximity probe system and supports a 5.0 meter system length. This configuration is commonly applied in compressor packages, pump systems, and fan assemblies where probe installation distance is moderate and routing is straightforward.\u003c\/p\u003e\n\u003cp\u003eThe design focus is operational simplicity: once installed and commissioned, it typically runs continuously with minimal adjustment.\u003c\/p\u003e\n\u003ch3\u003eEngineering Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-wire loop-powered vibration transmitter architecture\u003c\/li\u003e\n\u003cli\u003eConverts proximity probe signal into 4–20 mA output\u003c\/li\u003e\n\u003cli\u003eDesigned for 3300 NSv probe compatibility\u003c\/li\u003e\n\u003cli\u003eBulkhead screw mounting with 4-point fixation\u003c\/li\u003e\n\u003cli\u003eSupplied with 6-32 x 1.326 mounting screws when specified\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning electronics\u003c\/li\u003e\n\u003cli\u003eStable output for continuous vibration trending\u003c\/li\u003e\n\u003cli\u003eExternal zero\/span adjustment capability\u003c\/li\u003e\n\u003cli\u003ePROX OUT available for diagnostic signal access\u003c\/li\u003e\n\u003cli\u003eFault indication via output current drop behavior\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Perspective\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment Type\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentrifugal compressors\u003c\/td\u003e\n\u003ctd\u003eShaft vibration trending into PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n\u003ctd\u003eBearing condition monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling fans\u003c\/td\u003e\n\u003ctd\u003eMechanical imbalance detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM skid systems\u003c\/td\u003e\n\u003ctd\u003eEmbedded vibration input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary rotating machinery\u003c\/td\u003e\n\u003ctd\u003eAlarm and shutdown logic input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess support equipment\u003c\/td\u003e\n\u003ctd\u003eContinuous condition tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Structure\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eCode Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e04 = 0–4 mils pp (0–100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e50 = 5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e02 = Bulkhead screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Option\u003c\/td\u003e\n\u003ctd\u003e00 = Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical \u0026amp; Installation Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e990-04-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height (without DIN clip)\u003c\/td\u003e\n\u003ctd\u003e42.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Distance\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003e4 × bulkhead holes, 6-32 x 1.326 screws provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInterface Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Input\u003c\/td\u003e\n\u003ctd\u003eConnection to 3300 NSv proximity probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4–20 mA Output\u003c\/td\u003e\n\u003ctd\u003eVibration signal to PLC\/DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eLoop-powered DC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eRaw vibration diagnostic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSignal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Notes (Field Engineering View)\u003c\/h3\u003e\n\u003cp\u003eBulkhead mounting is typically selected when the panel layout requires a fixed and mechanically stable installation point. The four-point fixation reduces vibration-induced loosening, which can be a concern in compressor or pump skid environments.\u003c\/p\u003e\n\u003cp\u003eIn practical wiring design, probe signal routing should be separated from high-voltage or high-current conductors. This helps avoid induced noise, especially when cable runs are bundled inside compact enclosures.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify probe gap alignment and confirm loop current stability under steady machine operation. Engineers usually delay alarm logic activation until the signal behavior is confirmed under real operating conditions.\u003c\/p\u003e\n\u003cp\u003ePROX OUT is mainly used during maintenance or diagnostic checks rather than continuous monitoring in production.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is bulkhead mounting used in this model?\u003c\/strong\u003e\u003cbr\u003eIt provides a rigid enclosure-mounted installation with better mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre mounting screws included?\u003c\/strong\u003e\u003cbr\u003eYes, 6-32 x 1.326 screws are provided when the mounting option is specified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of this transmitter?\u003c\/strong\u003e\u003cbr\u003eIt converts vibration from a proximity probe into a 4–20 mA signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with PLC systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for direct PLC and DCS analog input integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe system is required?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 NSv proximity probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for compressor applications?\u003c\/strong\u003e\u003cbr\u003eYes, it is commonly used on compressors, pumps, and fans.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support vibration diagnostics?\u003c\/strong\u003e\u003cbr\u003eIt provides PROX OUT for basic diagnostic signal access.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it a full monitoring system?\u003c\/strong\u003e\u003cbr\u003eNo, it is a simplified vibration transmitter for trend-level monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe fails?\u003c\/strong\u003e\u003cbr\u003eThe output current drops to indicate a fault condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is it typically installed?\u003c\/strong\u003e\u003cbr\u003eInside control cabinets or skid-mounted equipment panels.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852933995,"sku":"990-04-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-02-00-vibration-transmitter-ghs0ash3mzd_bf0dfbdc-8417-4406-82f9-2a26d0af0b40.jpg?v=1765449099"},{"product_id":"bently-nevada-990-10-xx-01-05-mod-285269-01-2-wire-vibration-transmitter","title":"Bently Nevada 990-10-XX-01-05 MOD:285269-01 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e990-10-XX-01-05\u003c\/strong\u003e (including MOD:285269-01) is a 2-wire, loop-powered industrial vibration transmitter. It interfaces directly with a 3300 NSv proximity probe and its matching extension cable to provide non-contacting machinery protection. The transmitter conditions the eddy current sensor signals and outputs a proportional 4 to 20 mA analog current loop representing peak-to-peak vibration amplitude. This standalone design integrates an internal Proximitor sensor, allowing a direct connection to a distributed control system (DCS), programmable logic controller (PLC), or machinery control network without a separate monitoring rack. \u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Proximitor sensor eliminates the need for external processing units\u003c\/li\u003e\n\u003cli\u003eProportional 4 to 20 mA loop-powered output for straightforward control system integration\u003c\/li\u003e\n\u003cli\u003eNon-isolated PROX OUT and COM coaxial terminals for dynamic vibration and gap voltage diagnostics\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span potentiometers for simple calibration adjustments\u003c\/li\u003e\n\u003cli\u003eTest input pin for system verification using external function generators\u003c\/li\u003e\n\u003cli\u003eFully potted construction protecting interior circuits against harsh, high-humidity environments \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring on small centrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eMachinery protection for industrial motors and cooling tower fan systems\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance for small pumps and process gas equipment\u003c\/li\u003e\n\u003cli\u003eNon-contacting shaft displacement analysis in tight installation clearances \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectrical Parameters Value\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e2-wire, loop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e4 to 20 mA DC (proportional to peak-to-peak vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDiagnostic Outputs\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDynamic PROX OUT and COM terminal coaxial signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCompatible Sensor Input\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3300 NSv proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eSupported System Lengths\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5 m or 7 m configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003ePerformance and Physical Value\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0 to 5 mils pp (0 to 125 micrometers pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e5 Hz to 6000 Hz (at +\/-3 dB limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMinimum Target Diameter\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e9.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMounting Interface\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard DIN rail clip or bulkhead options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEnclosure Dimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e7.3 cm x 6 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eApproximate Net Weight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConnections \/ Interfaces\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eTerminal \/ Connector Function\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e+4-20mA\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePositive loop power supply and current output connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-4-20mA\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eNegative loop power supply return connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePROX OUT\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDynamic voltage signal output for vibration diagnostic instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eCOM\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCommon return reference terminal for diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eTEST IN\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eInput pin for loop-output verification via signal generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eCoaxial Connector\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eDirect connection to the 3300 NSv extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter securely onto a standard DIN rail or a flat bulkhead plate inside an appropriate environmental enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure the coaxial connections between the transmitter, extension cable, and 3300 NSv probe are clean, dry, and locked into place.\u003c\/li\u003e\n\u003cli\u003eRoute the high-level 4 to 20 mA current loop wiring away from high-voltage motor power leads to avoid electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eAvoid exposing the terminal connections directly to continuous water spray or standing moisture; house the hardware in an IP54 or better enclosure if necessary.\u003c\/li\u003e\n\u003cli\u003eUse the non-interacting zero and span potentiometers carefully when running field loop performance trims. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompliance and Certifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the Bently Nevada 990-10-XX-01-05?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt functions as a loop-powered transmitter that processes proximity probe signals into a standard 4 to 20 mA output for a PLC or DCS. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this device require a separate Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it has an integrated Proximitor sensor, eliminating the need for external processing hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich proximity probes are electrically compatible with this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed exclusively to interface with Bently Nevada 3300 NSv proximity probes and matching extension cables. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the XX signify in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe XX denotes specific unlisted sub-options within the ordering guide, such as specific full-scale range calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can field engineers access dynamic vibration waveforms for diagnostic analysis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDynamic signals can be checked directly across the PROX OUT and COM coaxial terminals using a portable vibration analyzer or oscilloscope.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of machinery is this transmitter optimized for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is primarily intended for industrial OEMs of centrifugal air compressors, small pumps, fans, and electric motors. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter a loop-powered or a 4-wire device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a 2-wire, loop-powered device that receives power and transmits data over the same current loop. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat engineering units are represented by the 4 to 20 mA signal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe current signal represents the peak-to-peak vibration amplitude of the target machine shaft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the physical dimensions of the chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter body measures approximately 7.3 cm x 6 cm x 10 cm. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I verify the loop output without moving the machine shaft?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, you can use the designated Test Input pin with an external function generator to simulate input signals and verify loop response.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858045803,"sku":"990-10-XX-01-05 MOD:285269-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-xx-01-05-mod-285269-01-2-wire-vibration-transmitter-idog5ppy2b2_eef6852e-4988-4c74-a518-d0a7ad920161.jpg?v=1765449234"},{"product_id":"bently-nevada-990-04-70-02-00-2-wire-vibration-transmitter","title":"Bently Nevada 990-04-70-02-00 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-04-70-02-00\u003c\/strong\u003e is a loop-powered vibration transmitter designed for straightforward integration into rotating equipment protection and monitoring systems. It translates proximity probe vibration input into a standard 4 to 20 mA signal for use in PLC and DCS environments, focusing on stable long-term trending rather than full diagnostic vibration analysis.\u003c\/p\u003e\n\u003cp\u003eThis version uses a \u003cstrong\u003ebulkhead screw mounting design\u003c\/strong\u003e, making it more suitable for installations where panel surface mounting is preferred over DIN rail systems. In practice, it is often selected for compact OEM skids, retrofit panels, or locations where mechanical fixation strength is prioritized over modular rail layouts.\u003c\/p\u003e\n\u003cp\u003eEngineers typically deploy this model on compressors, pumps, and small rotating machines where vibration thresholds need continuous supervision without adding complexity to the control architecture. The integrated signal conditioning electronics reduce external wiring and simplify commissioning during machine build or site installation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e0-4 mils pp full-scale range\u003c\/strong\u003e supports tighter vibration resolution, which is useful in applications requiring early detection of mechanical wear or imbalance trends.\u003c\/p\u003e\n\u003ch3\u003eKey Design Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-wire loop-powered vibration transmitter architecture\u003c\/li\u003e\n\u003cli\u003eConverts proximity probe input into 4 to 20 mA signal\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 NSv probe systems\u003c\/li\u003e\n\u003cli\u003eBulkhead screw mounting for direct panel installation\u003c\/li\u003e\n\u003cli\u003eIntegrated Proximitor signal conditioning module\u003c\/li\u003e\n\u003cli\u003eCompact sealed industrial housing\u003c\/li\u003e\n\u003cli\u003eSupports basic vibration trending applications\u003c\/li\u003e\n\u003cli\u003eAccess to raw vibration signal via PROX OUT\u003c\/li\u003e\n\u003cli\u003eExternal zero and span adjustment capability\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous industrial operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment Type\u003c\/th\u003e\n\u003cth\u003eMonitoring Purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall centrifugal compressors\u003c\/td\u003e\n\u003ctd\u003eShaft vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n\u003ctd\u003eBearing condition trending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFans and ventilation systems\u003c\/td\u003e\n\u003ctd\u003eImbalance detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM machinery packages\u003c\/td\u003e\n\u003ctd\u003eEmbedded vibration feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess skids\u003c\/td\u003e\n\u003ctd\u003eContinuous condition monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary drive systems\u003c\/td\u003e\n\u003ctd\u003eBasic protection logic input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Structure\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eCode Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e-04 = 0-4 mils pp (0-100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e-70 = 7.0 metres (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e-02 = Bulkhead screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e-00 = Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Summary\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e990-04-70-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew \u0026amp; Original in Factory Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Warranty\u003c\/td\u003e\n\u003ctd\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Source\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-4 mils pp (0-100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cable Length\u003c\/td\u003e\n\u003ctd\u003e7.0 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eBulkhead screw fixation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInterface Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal \/ Interface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Input\u003c\/td\u003e\n\u003ctd\u003eAccepts 3300 NSv proximity probe signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Output\u003c\/td\u003e\n\u003ctd\u003eVibration signal to PLC\/DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eLoop-powered DC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration diagnostic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSignal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Notes (Engineering Perspective)\u003c\/h3\u003e\n\u003cp\u003eThis version is typically installed directly onto a control panel surface using bulkhead screws, which provides better mechanical rigidity in environments with vibration or limited DIN rail availability.\u003c\/p\u003e\n\u003cp\u003eCable routing should maintain separation between low-level probe wiring and high-current conductors to reduce induced noise. Proper shielding and grounding practices are important for maintaining signal stability over long cable runs.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, verify probe gap alignment before energizing the loop. Once operational, confirm that the 4 to 20 mA signal stabilizes under steady machine conditions before enabling protection logic in the control system.\u003c\/p\u003e\n\u003cp\u003eThe PROX OUT interface should be used only with appropriate isolated measurement equipment to avoid ground loop effects.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose bulkhead screw mounting for this model?\u003c\/strong\u003e\u003cbr\u003eIt is preferred when panel rigidity and fixed mechanical mounting are required instead of DIN rail flexibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this transmitter suitable for PLC integration?\u003c\/strong\u003e\u003cbr\u003eYes, it provides a standard 4 to 20 mA output designed for PLC analog input modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe system is required?\u003c\/strong\u003e\u003cbr\u003eIt is designed for use with the Bently Nevada 3300 NSv proximity probe family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the 0-4 mils range?\u003c\/strong\u003e\u003cbr\u003eIt provides higher resolution vibration monitoring for tighter mechanical tolerances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support diagnostic signal access?\u003c\/strong\u003e\u003cbr\u003eYes, PROX OUT provides raw vibration data for external analysis tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a rack-based monitoring system?\u003c\/strong\u003e\u003cbr\u003eNo, it is a standalone transmitter intended for simplified machine protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during probe failure?\u003c\/strong\u003e\u003cbr\u003eThe output drops to a fault condition below normal operating current levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environments can it operate in?\u003c\/strong\u003e\u003cbr\u003eIt is designed for industrial environments with temperatures from -35 degC to +85 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used on compressors and pumps?\u003c\/strong\u003e\u003cbr\u003eYes, it is commonly used on small rotating machinery such as compressors and pumps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this version available immediately?\u003c\/strong\u003e\u003cbr\u003eYes, it is listed as in stock.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858504555,"sku":"990-04-70-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-70-02-00-vibration-transmitter-bipupyjwwre_1e9723c0-7f5c-48e5-a9e1-5e555f6e3465.jpg?v=1765449239"},{"product_id":"bently-nevada-990-04-50-02-cn-2-wire-vibration-transmitter","title":"Bently Nevada 990-04-50-02-CN 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-04-50-02-CN\u003c\/strong\u003e is a loop-powered vibration transmitter designed for converting proximity probe signals into a standardized 4 to 20 mA output for machinery monitoring systems. It is used in rotating equipment applications where vibration needs to be continuously tracked without deploying a full vibration monitoring rack.\u003c\/p\u003e\n\u003cp\u003eThis configuration is typically chosen when a \u003cstrong\u003ebulkhead-mounted installation\u003c\/strong\u003e is preferred over DIN rail mounting. In practical panel design, this is often the case when engineers want the transmitter fixed directly to the enclosure wall for improved mechanical stability or simplified wiring layout.\u003c\/p\u003e\n\u003cp\u003eThe device is intended for use with a 3300 NSv proximity probe system and supports a 5.0 meter system length. This makes it suitable for compact to medium-sized rotating machinery installations such as compressors, pumps, and fan assemblies where probe routing remains relatively short and controlled.\u003c\/p\u003e\n\u003cp\u003eFrom a field engineering perspective, this version is often used when installation rigidity and straightforward panel layout take priority over modular mounting flexibility.\u003c\/p\u003e\n\u003ch3\u003eEngineering Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-wire loop-powered vibration transmitter architecture\u003c\/li\u003e\n\u003cli\u003eConverts proximity probe displacement into 4–20 mA output\u003c\/li\u003e\n\u003cli\u003eDesigned for 3300 NSv probe system compatibility\u003c\/li\u003e\n\u003cli\u003eBulkhead screw mounting for direct enclosure installation\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning electronics\u003c\/li\u003e\n\u003cli\u003eStable output for continuous vibration trending\u003c\/li\u003e\n\u003cli\u003eExternal zero\/span adjustment for calibration\u003c\/li\u003e\n\u003cli\u003ePROX OUT available for diagnostic signal access\u003c\/li\u003e\n\u003cli\u003eFault detection with current drop behavior on signal failure\u003c\/li\u003e\n\u003cli\u003eSealed compact industrial housing design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Context\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment Type\u003c\/th\u003e\n\u003cth\u003ePractical Role\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentrifugal compressors\u003c\/td\u003e\n\u003ctd\u003eShaft vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n\u003ctd\u003eBearing condition tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFans and blowers\u003c\/td\u003e\n\u003ctd\u003eImbalance detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM skid packages\u003c\/td\u003e\n\u003ctd\u003eEmbedded protection input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess auxiliary systems\u003c\/td\u003e\n\u003ctd\u003ePLC-based alarm input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral rotating equipment\u003c\/td\u003e\n\u003ctd\u003eContinuous vibration trending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Structure\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eCode Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e04 = 0–4 mils pp (0–100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e50 = 5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e02 = Bulkhead screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Option\u003c\/td\u003e\n\u003ctd\u003eCN configuration variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Transmitter)\u003c\/td\u003e\n\u003ctd\u003e-35 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature (Transmitter)\u003c\/td\u003e\n\u003ctd\u003e-52 C to +100 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n\u003ctd\u003e-52 C to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature (Probe)\u003c\/td\u003e\n\u003ctd\u003e-52 C to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e990-04-50-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height (without DIN clip)\u003c\/td\u003e\n\u003ctd\u003e42.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Distance\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInterface Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Input\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4–20 mA Output\u003c\/td\u003e\n\u003ctd\u003eVibration signal to PLC\/DCS system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eLoop-powered DC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eRaw vibration diagnostic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSignal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Notes (Field Engineering View)\u003c\/h3\u003e\n\u003cp\u003eBulkhead mounting changes the mechanical behavior of the installation compared to DIN rail versions. In real panel work, this model is usually mounted directly onto the enclosure wall to reduce movement and improve strain resistance on wiring.\u003c\/p\u003e\n\u003cp\u003eCable routing should be planned to avoid long parallel runs with motor feeders or inverter output cables. This is especially important in compressor and pump packages where electromagnetic noise can distort low-level probe signals.\u003c\/p\u003e\n\u003cp\u003eBefore system start-up, probe gap alignment should be verified carefully. After power-up, allow the loop signal to stabilize under steady machine conditions before enabling alarm logic in the control system.\u003c\/p\u003e\n\u003cp\u003ePROX OUT is typically used during commissioning or troubleshooting rather than continuous operation.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose bulkhead mounting for this version?\u003c\/strong\u003e\u003cbr\u003eIt provides a fixed mechanical installation point directly on the enclosure wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this compatible with PLC systems?\u003c\/strong\u003e\u003cbr\u003eYes, it outputs a standard 4–20 mA signal for PLC or DCS inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe system does it require?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 NSv proximity probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a full diagnostic system?\u003c\/strong\u003e\u003cbr\u003eNo, it is intended for vibration trending and basic protection logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of PROX OUT?\u003c\/strong\u003e\u003cbr\u003eIt provides raw vibration signal output for diagnostic measurement tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the probe fails?\u003c\/strong\u003e\u003cbr\u003eThe output drops to a low-current fault state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is it typically used?\u003c\/strong\u003e\u003cbr\u003eOn compressors, pumps, fans, and other rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require external signal conditioning?\u003c\/strong\u003e\u003cbr\u003eNo, conditioning is fully integrated into the transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for skid-mounted equipment?\u003c\/strong\u003e\u003cbr\u003eYes, especially where rigid enclosure mounting is preferred.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate in humid environments?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for high humidity and condensing conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861125995,"sku":"990-04-50-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-04-50-02-cn-vibration-monitor-4epp5ugexd4_8904adbf-22ea-4ebc-98e7-af0a99c75075.jpg?v=1765449302"},{"product_id":"bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter","title":"Bently Nevada 990-05-XX-03-CN 104M6732-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e990-05-XX-03-CN\u003c\/strong\u003e (Internal Part Number: \u003cstrong\u003e104M6732-01\u003c\/strong\u003e) is a high-accuracy, loop-powered \u003cstrong\u003e2-wire vibration transmitter\u003c\/strong\u003e engineered to provide continuous, standalone machinery asset protection. This field-rugged industrial instrument integrates the functionality of a proximity sensor conditioner and transmitter into a single unified circuit block, converting raw non-contacting proximity probe inputs directly into an industry-standard 4-20 mA analog current loop output proportional to overall shaft vibration. The \u003cstrong\u003e990-05-XX-03-CN 104M6732-01\u003c\/strong\u003e accepts dynamic electrical signals from a standard proximity probe array and processes raw peak-to-peak displacement, delivering an immediate, linear current stream to local programmable logic controllers (PLCs), distributed control systems (DCSs), or SCADA platforms. Designed specifically with space-restricted and safety-critical machinery skids in mind, it interfaces with external measurement loops without requiring an intermediate Proximitor sensor housing. It features physical terminal integration supporting a 4-20 mA current output loop, separate dynamic voltage output points for portable vibration analyzers, and special hardware certification variants for localized control markets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 2-wire transmitter design providing a direct 4-20 mA proportional current output path without intermediate signal conditioners.\u003c\/li\u003e\n\u003cli\u003eDynamic voltage output terminal provisioning real-time raw proximity waveforms directly to field analyzers.\u003c\/li\u003e\n\u003cli\u003eRobust electrical isolation and solid-state encapsulation to eliminate electrical noise interference inside tight machine enclosures.\u003c\/li\u003e\n\u003cli\u003eSeamless host system integration linking directly with any control interface featuring standard analog current input blocks.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability vibration tracking across thin fluid-filmed bearing shells and rotating shaft assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous radial vibration and casing displacement tracking on centrifugal air and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eCritical machinery safety loops on high-speed industrial fans, cooling pumps, and fluid-handling blowers.\u003c\/li\u003e\n\u003cli\u003eStandalone balancing and predictive maintenance monitoring across small-scale power generation turbines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990 (2-Wire Vibration Transmitter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Factory Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M6732-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Code Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05 (System Full-Scale Range Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-XX (Variable Options Selection Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-03 (Mounting Hardware Base Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-CN (Regional Specific Certification \/ Approval Suffix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M6732-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Interface Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop-powered current loop circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC proportional to overall peak-to-peak vibration displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Waveform Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered voltage output terminal for local analyzer plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Power Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC external supply loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting proximity transducer probe assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 Option Specific Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Envelope Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03 Mounting Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Assembly Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN Certified Configuration Variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Mechanical Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum housing with integrated terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Core Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-profile compact footprint optimized for high-density side-by-side rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field transmitter assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Point Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Function Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ \/ Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive DC Loop Voltage Input Supply \/ Signal Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- \/ Return\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Return \/ Current Loop Signal Output Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF \/ Dynamic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic Raw Voltage Output Signal Point (For portable vibration meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM \/ Ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon Circuit Ground reference terminal line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated connection terminal block input for external proximity probe lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Chassis Mounting:\u003c\/strong\u003e Fix the transmitter block securely onto a clean, unpainted, vibration-isolated instrument panel inside an electrical enclosure. Verify proper physical layout alignment to prevent internal structural stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Probe Connection:\u003c\/strong\u003e Direct the primary proximity transducer coaxial lead wire straight into the designated input terminal channel block. Keep the internal signal wires separate from any high-voltage motor electrical conduits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Power Verification:\u003c\/strong\u003e Check the overall loop resistance parameters and source power input ratings before energizing the 4-20 mA current network lines to avoid unexpected component strain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Terminal Shielding:\u003c\/strong\u003e Ensure the dynamic voltage output terminal covers are completely sealed when not hooked up to local portable instruments to keep moisture and dust off the diagnostic contacts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863157611,"sku":"990-05-XX-03-CN 104M6732-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-xx-03-cn-104m6732-01-vibration-transmitter-2p0d2asnnce_24d3e90c-bdb7-4d6a-ae74-4313620d804e.jpg?v=1765449361"},{"product_id":"bently-nevada-990-05-xx-03-cn-104m1359-01-vibration-transmitter","title":"Bently Nevada 990-05-XX-03-CN 104M1359-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-XX-03-CN\u003c\/strong\u003e (Internal Part Number: \u003cstrong\u003e104M1359-01\u003c\/strong\u003e) is an industrial, loop-powered \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business) to deliver continuous machinery condition tracking directly to plant control systems. This integrated field unit combines the signal-conditioning electronics of a proximity sensor and a transmitter into a single, space-saving package. It accepts inputs from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable system, converting dynamic shaft micro-gap variations into a linear 4 to 20 mA analog current loop. This direct interface allows plant operators to route critical vibration data straight into Programmable Logic Controllers (PLC) or Distributed Control Systems (DCS) without the need for a separate rack-based monitoring monitor.\u003c\/p\u003e\n\u003cp\u003eThe exact hardware configuration \u003cstrong\u003e990-05-XX-03-CN\u003c\/strong\u003e features a factory-calibrated \u003cstrong\u003efull-scale measurement scale of 0-5 mils pp (0-125 um pp)\u003c\/strong\u003e, optimized for monitoring radial shaft vibration amplitudes. It is equipped with a \u003cstrong\u003eBulkhead Coaxial Connector Mounting Option\u003c\/strong\u003e, ensuring a high-integrity mechanical and electrical anchor through junction box enclosures or field bulkheads. Certified with the \u003cstrong\u003eCN agency approval designation\u003c\/strong\u003e, this module complies with global safety frameworks, including ATEX\/IECEx and local Chinese NEPSI hazardous area regulations. The part number \u003cstrong\u003e104M1359-01\u003c\/strong\u003e represents the modern OEM manufacturing assembly designation, incorporating upgraded high-stability surface-mount components and improved RFI\/EMI shielding over older product iterations while maintaining identical physical and electrical drop-in backward compatibility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire loop-powered configuration providing a direct 4 to 20 mA proportional current output to DCS\/PLC automation cards.\u003c\/li\u003e\n\u003cli\u003eStandardized 0-5 mils peak-to-peak (0-125 um peak-to-peak) linear scale calibration for precision shaft vibration logging.\u003c\/li\u003e\n\u003cli\u003eRobust bulkhead coaxial mounting arrangement for secure structural installation through panel or enclosure walls.\u003c\/li\u003e\n\u003cli\u003eDual hazardous zone certifications matching global ATEX\/IECEx standards with local Chinese NEPSI industrial markings.\u003c\/li\u003e\n\u003cli\u003eModern 104M1359-01 component build featuring enhanced noise immunity and thermal stability in harsh processing zones.\u003c\/li\u003e\n\u003cli\u003eFront-mounted isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for on-site diagnostic analyzers.\u003c\/li\u003e\n\u003cli\u003eIndependent non-interacting zero and span adjustment pots allowing seamless calibration verification under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandalone radial shaft vibration monitoring on fluid-filmed bearings of industrial process fans and blowers.\u003c\/li\u003e\n\u003cli\u003eDirect asset protection loop integration for medium-sized balance-of-plant electric motors and centrifugal pump skids.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery monitoring inside remote oil and gas transport pipeline stations or water utility infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils peak-to-peak (0-125 um peak-to-peak) scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length (Matches probe\/cable parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-03\u003c\/td\u003e\n\u003ctd\u003eBulkhead coaxial connector mounting layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCombined ATEX\/IECEx and Chinese NEPSI hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M1359-01\u003c\/td\u003e\n\u003ctd\u003eModern factory production assembly code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-03-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOEM Assembly Part ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104M1359-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils pp (0 to 125 um pp) displacement amplitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Loop Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional 4 to 20 mAdc current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to the raw probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the termination interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Matching Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Block Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts wire gauges up to 1.5 mm squares (16 to 24 AWG) solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body integrated with an anodized aluminum base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing atmosphere constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTermination Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial connection port receiving the incoming transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive current loop terminal receiving incoming +12 to +35 Vdc loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative current loop connection returning the regulated 4 to 20 mA measurement tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel isolated BNC dynamic port providing unconditioned sensor voltage waves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulkhead Mount Assembly:\u003c\/strong\u003e Secure the transmitter body through the enclosure wall panel or custom bulkhead interface plates using the integrated mechanical thread mounts to ensure a clean, rattle-free anchor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Ground Isolation:\u003c\/strong\u003e Verify that the transmitter housing base plate remains electrically isolated from structural cabinet metals. This isolation blocks raw loop noise and prevents ground currents from corrupting vibration waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Synchronization:\u003c\/strong\u003e Check that your specified system length option (Option -XX) perfectly matches the total physical length of the attached 3300 XL 8mm probe and extension cable to maintain calibrated accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostics:\u003c\/strong\u003e Connect vibration data collectors directly to the front-facing BNC socket for diagnostics. This isolated port outputs raw data (200 mV\/mil) without affecting or interrupting the primary 4-20 mA control loop signaling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864238955,"sku":"990-05-XX-03-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-xx-03-cn-104m1359-01-vibration-transmitter-yrd0eij2nni_f1f4fa4b-ad69-4c46-a7a2-bce4364d89b8.jpg?v=1765449392"},{"product_id":"bently-nevada-990-10-xx-01-00-283278-01-vibration-transmitter","title":"Bently Nevada 990-10-XX-01-00 283278-01 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-10-XX-01-00\u003c\/strong\u003e (Internal SKU\/Part Number: \u003cstrong\u003e283278-01\u003c\/strong\u003e) is an industrial, loop-powered \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business). This specialized device provides continuous machinery condition monitoring and asset protection by interfacing field transducers directly with plant automation systems. It integrates the high-frequency signal conditioning electronics of a proximity sensor and an analog transmitter into a single, compact polycarbonate housing. The unit accepts inputs from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable system, converting raw shaft micro-gap variations into a linear, proportional 4 to 20 mA analog current loop output. This configuration enables plant operators to route critical radial vibration data straight to Distributed Control Systems (DCS) or Programmable Logic Controllers (PLC) without the added infrastructure of a separate, rack-based monitor chassis.\u003c\/p\u003e\n\u003cp\u003eThis exact hardware configuration features an expanded factory-calibrated \u003cstrong\u003efull-scale measurement scale of 0-10 mils pp (0-250 um pp)\u003c\/strong\u003e, designed for machines with larger expected rotor vibration amplitudes. The unit is equipped with integrated \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e for rapid, toolless snap-on installation into local marshalling junction boxes. The agency option is designated as \u003cstrong\u003e-00\u003c\/strong\u003e, which represents the standard, non-hazardous area base model for general-purpose plant zones. The internal tracking number \u003cstrong\u003e283278-01\u003c\/strong\u003e represents the modern OEM manufacturing assembly designation, incorporating high-stability surface-mount components and enhanced RFI\/EMI noise suppression filters over legacy iterations while maintaining identical physical and electrical drop-in backward compatibility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire, loop-powered configuration that routes a proportional 4 to 20 mA analog signal directly to host DCS or PLC automation cards.\u003c\/li\u003e\n\u003cli\u003eExpanded 0-10 mils peak-to-peak (0-250 um peak-to-peak) linear scale calibration for high-amplitude shaft displacement logging.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty 35 mm DIN rail clips for secure, vibration-resistant installation on standard terminal enclosure tracks.\u003c\/li\u003e\n\u003cli\u003eStandard-area application footprint (-00 option) engineered for reliable cost-effective deployment in non-classified plant zones.\u003c\/li\u003e\n\u003cli\u003eModern 283278-01 component build featuring enhanced noise immunity and thermal stability in harsh processing environments.\u003c\/li\u003e\n\u003cli\u003eFront-mounted, isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for local diagnostic data collectors.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustment pots allowing seamless, independent calibration verification under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous radial shaft vibration monitoring on fluid-filmed bearings of industrial turbo-fans, exhausters, and blowers.\u003c\/li\u003e\n\u003cli\u003eStandalone asset protection loop integration for large electric motors, industrial gearboxes, and high-capacity centrifugal pumps.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery condition monitoring inside factory utility rooms, water handling skids, and HVAC cooling towers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0-10 mils peak-to-peak (0-250 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length (Matches probe\/cable design parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips factory-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eNone (Standard safety area classification for non-hazardous zones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Assembly Part ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e283278-01\u003c\/td\u003e\n\u003ctd\u003eModern factory production assembly code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-XX-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOEM Assembly Part ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e283278-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 mils pp (0 to 250 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Loop Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional 4 to 20 mAdc current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to raw probe gap voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for standard 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Block Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal strip accepting wire cross-sections up to 1.5 mm squares (16 to 24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure integrated with an aluminum base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing atmosphere constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE Coaxial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial connection point receiving the incoming transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive current loop connection receiving incoming +12 to +35 Vdc loop power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative current loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF BNC Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel isolated BNC socket providing unconditioned sensor voltage waves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter backplate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864894315,"sku":"990-10-XX-01-00 283278-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-xx-01-00-283278-01-vibration-transmitters-jhqrcqlj0j4_497e5c40-6a6e-4963-bdbc-02b2a6f1142a.jpg?v=1765449403"},{"product_id":"bently-nevada-990-10-xx-01-00-mod-165353-01-990-vibration-transmitter","title":"Bently Nevada 990-10-XX-01-00 MOD:165353-01 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-10-XX-01-00 MOD:165353-01\u003c\/strong\u003e is a loop-powered, two-wire \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business). It is engineered to provide continuous machinery condition monitoring and asset protection by interfacing directly with plant automation systems. This field-mountable instrument integrates the signal conditioning electronics of a proximity sensor and an analog transmitter into a single, space-saving housing. It accepts high-frequency inputs from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable, processing raw target gap variations into a linear 4 to 20 mA current loop output. This proportional signal routes directly to standard Distributed Control Systems (DCS) or Programmable Logic Controllers (PLC) without requiring a separate rack monitoring system.\u003c\/p\u003e\n\u003cp\u003eThis exact configuration features a factory-calibrated \u003cstrong\u003efull-scale measurement scale of 0-10 mils pp (0-250 um pp)\u003c\/strong\u003e, designed for machines with larger expected rotor vibration amplitudes. The unit is equipped with integrated \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e for rapid, toolless snap-on installation into local marshalling junction boxes. The agency option is designated as \u003cstrong\u003e-00\u003c\/strong\u003e, which represents the standard, non-hazardous area base model for general-purpose plant zones. The specialized factory suffix \u003cstrong\u003eMOD:165353-01\u003c\/strong\u003e denotes a controlled engineering modification that provides precise hardware component optimization or specific filter tuning tailored to optimized machinery metrics while maintaining standard physical chassis profiles.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire, loop-powered configuration that routes a proportional 4 to 20 mA analog signal directly to host DCS or PLC automation cards.\u003c\/li\u003e\n\u003cli\u003eExpanded 0-10 mils peak-to-peak (0-250 um peak-to-peak) linear scale calibration for high-amplitude shaft displacement logging.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty 35 mm DIN rail clips for secure, vibration-resistant installation on standard terminal enclosure tracks.\u003c\/li\u003e\n\u003cli\u003eStandard-area application footprint (-00 option) engineered for reliable cost-effective deployment in non-classified plant zones.\u003c\/li\u003e\n\u003cli\u003eFactory modification code MOD:165353-01 for specialized internal filtering stability and target material synchronization.\u003c\/li\u003e\n\u003cli\u003eFront-mounted, isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for local diagnostic data collectors.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustment pots allowing seamless, independent calibration verification under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous radial shaft vibration monitoring on fluid-filmed bearings of industrial turbo-fans, exhausters, and blowers.\u003c\/li\u003e\n\u003cli\u003eStandalone asset protection loop integration for large electric motors, industrial gearboxes, and high-capacity centrifugal pumps.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery condition monitoring inside factory utility rooms, water handling skids, and HVAC cooling towers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0-10 mils peak-to-peak (0-250 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length (Matches probe\/cable design parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips factory-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eNone (Standard safety area classification for non-hazardous zones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD:165353-01\u003c\/td\u003e\n\u003ctd\u003eSpecialized factory hardware configuration modification code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-10-XX-01-00 MOD:165353-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 mils pp (0 to 250 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Loop Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional 4 to 20 mAdc current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to raw probe gap voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for standard 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Block Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal strip accepting wire cross-sections up to 1.5 mm squares (16 to 24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure integrated with an aluminum base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing atmosphere constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE Coaxial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial connection point receiving the incoming transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive current loop connection receiving incoming +12 to +35 Vdc loop power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative current loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF BNC Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel isolated BNC socket providing unconditioned sensor voltage waves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter backplate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866172267,"sku":"990-10-XX-01-00 MOD:165353-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-10-xx-01-00-mod-165353-01-vibration-transmitters-g0ysqlauzfu_d754ba18-e8d0-488f-adc2-9145d8da6a5b.jpg?v=1765449457"},{"product_id":"bently-nevada-990-05-70-02-05-vibration-transmitter","title":"Bently Nevada 990-05-70-02-05 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-70-02-05\u003c\/strong\u003e is a 2-wire, loop-powered vibration transmitter developed for original equipment manufacturers (OEMs) of rotating machinery. It integrates the functional capabilities of a proximity probe driver (proximitor) and signal conditioning electronics into a single, compact field unit. The transmitter tracks dynamic radial vibration or shaft elongation by interfacing directly with a non-contacting proximity transducer system, translating raw displacement data into a proportional 4-20 mA analog current output. This continuous current loop interfaces directly into distributed control systems (DCS), programmable logic controllers (PLCs), or SCADA networks without the addition of separate monitor racks or dedicated proximitor modules, making it a space-efficient selection for critical machinery safety loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated driver and signal conditioning circuitry to reduce instrumentation layout footprints.\u003c\/li\u003e\n\u003cli\u003e2-wire loop-powered configuration providing a 4-20 mA DC signal representation of vibration levels.\u003c\/li\u003e\n\u003cli\u003eAccessible frontal BNC jack delivering a buffered dynamic raw voltage output (Prox Out) scaled at 200 mV\/mil.\u003c\/li\u003e\n\u003cli\u003eSpecialized tuning optimized for direct interface with the 3300 NSv proximity transducer system.\u003c\/li\u003e\n\u003cli\u003eReliable design constructed to maintain precision under extreme temperature variants and high-vibration stresses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressor radial vibration and shaft movement tracking.\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pump and motor mechanical protection.\u003c\/li\u003e\n\u003cli\u003eCooling tower fan and blower structural safety loops.\u003c\/li\u003e\n\u003cli\u003eOEM rotating asset integrated control panel configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: 2-Wire Vibration Transmitter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-Scale Range Option: 0 to 5 mils peak-to-peak (0 to 125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option: 7.0 meters (23.0 feet) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: Bulkhead screws configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Certified for CSA\/ATEX Zone 0, Zone 2, and ABS maritime standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-70-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Proximitor and Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (proportional to 0-5 mils pp displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz (+0 dB, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc (at the transmitter terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Calibration Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (via front-accessible BNC connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Match\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 NSv Proximity Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.95 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.3 mm x 81.3 mm x 44.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal block (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Loop Power Input (+12 to +35 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal block (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Loop Return \/ Current Signal Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBNC Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Prox Out Dynamic Raw Signal (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput connection from the 3300 NSv proximity probe extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Bulkhead Installation:\u003c\/strong\u003e Mount the transmitter module securely onto a flat panel surface inside an enclosure using the bulkhead screw holes provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Setup:\u003c\/strong\u003e Install and gap the 3300 NSv proximity probe relative to the target material according to project engineering guidelines. Connect the 7.0m extension cable between the probe and the transmitter coaxial input port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Wrap the probe-to-extension cable coaxial connections with self-fusing silicone tape to prevent moisture infiltration and grounding errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Loop Wiring:\u003c\/strong\u003e Connect the 4-20 mA signal wires from the receiver instrument to the transmitter terminal block while maintaining correct (+\/-) polarity. Do not exceed the maximum supply limit of 35 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Avoidance:\u003c\/strong\u003e Route transmitter loop wiring and probe extension cables isolated from variable frequency drive (VFD) outputs, motor supply wires, or high-voltage AC electrical lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Verification:\u003c\/strong\u003e Energize the loop circuit and verify a standard 4 mA baseline output when the monitored shaft is completely static.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA Certified Zone 0 \/ Zone 2\u003c\/li\u003e\n\u003cli\u003eATEX Certified Zone 0 \/ Zone 2\u003c\/li\u003e\n\u003cli\u003eABS Maritime Type Certification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869547371,"sku":"990-05-70-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-02-05-vibration-transmitter-t1w2xbl0y0j_0c55c315-3a36-413c-9be3-504fcf6770ea.jpg?v=1765449576"},{"product_id":"990-05-70-02-01-bently-nevada-vibration-transmitter-get-a-quote","title":"990-05-70-02-01 Bently Nevada Vibration Transmitter | Get a Quote","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-70-02-01\u003c\/strong\u003e is a loop-powered vibration transmitter that integrates a non-contacting proximity probe sensor driver and analog signal conditioning electronics into a single module. It measures standard radial shaft vibration on rotating machinery and outputs a continuous 4 to 20 mA current loop signal directly to a PLC, DCS, or SCADA system. This direct-to-control architecture eliminates the necessity of a separate, dedicated monitoring rack. By utilizing eddy current measurement principles, the transmitter monitors dynamic shaft movement without mechanical wear, delivering reliable protection data for plant operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated driver and signal conditioner design reduces panel space requirements.\u003c\/li\u003e\n\u003cli\u003eDirect 4-20 mA output interfaces smoothly with standard industrial control platforms.\u003c\/li\u003e\n\u003cli\u003eNon-contacting eddy current measurement eliminates mechanical friction and wear.\u003c\/li\u003e\n\u003cli\u003eAccessible front BNC connector delivers buffered raw vibration signals for diagnostics.\u003c\/li\u003e\n\u003cli\u003eSolid-state circuit protection guards against wiring errors and voltage surges.\u003c\/li\u003e\n\u003cli\u003eRobust environmental design engineered for placement in harsh industrial process areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressor vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eSmall industrial fan and process blower protection.\u003c\/li\u003e\n\u003cli\u003eCooling tower fan mechanical protection loops.\u003c\/li\u003e\n\u003cli\u003eIndustrial centrifugal pump shaft tracking.\u003c\/li\u003e\n\u003cli\u003eElectric motor and generator asset monitoring.\u003c\/li\u003e\n\u003cli\u003eHydroelectric turbine rotor displacement analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e990\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: Bently Nevada 990 Vibration Transmitter Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-Scale Range Option: 0 to 5 mils pp (0 to 125 um pp) radial vibration range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option: 7.0 meters (23.0 feet) total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: 35 mm DIN-rail mount style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA, ATEX, and IECEx intrinsic safety and non-incendive approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-70-02-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Proximity Probe Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts input from a 3300 XL 5mm or 8mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC (proportional to full-scale vibration range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 35 VDC (measured at the transmitter terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRaw Vibration Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered signal via BNC connector (nominal 7.87 V\/mm or 200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC (-31 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +100 degC (-40 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyamide (PBT) blend, corrosion-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lbs) approx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 43.2 mm x 94.0 mm (3.20 in x 1.70 in x 3.70 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Install the transmitter securely onto a clean 35mm DIN rail inside a protective field enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Placement:\u003c\/strong\u003e Install the proximity probe and extension cable at the designated machine bearing housing. Maintain a minimum cable bend radius of 25.4 mm (1 in) to prevent internal core damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the extension cable to the transmitter location. Avoid routing probe cables parallel to high-voltage power lines or variable frequency drive wiring to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Connection:\u003c\/strong\u003e Connect the probe extension cable to the coaxial connector located on the bottom of the transmitter housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Wiring:\u003c\/strong\u003e Wire the 4-20mA loop power source to the transmitter terminal block. Ensure correct polarity is maintained: Terminal 1 (+) and Terminal 2 (-). Isolate the power supply before connecting any field wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate the cable shields properly at the control room instrument ground only. Do not ground the shield at both ends to prevent destructive ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666870104427,"sku":"990-05-70-02-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-70-02-01-vibration-transmitter-ttuo5x40ixp_2fdb38fa-a047-49e7-b914-e8d4d7445d9c.jpg?v=1765449595"},{"product_id":"bently-nevada-177230-02-seismic-transmitter","title":"Bently Nevada 177230-02 Seismic Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous machinery vibration monitoring, the \u003cstrong\u003eBently Nevada 177230-02\u003c\/strong\u003e seismic transmitter provides a reliable 4 to 20 mA loop-powered output proportional to overall vibration velocity. This solid-state sensor is engineered to integrate directly with PLC, DCS, and SCADA control systems without requiring an external interface module. Operating by measuring case vibration, it provides an efficient and cost-effective method for tracking the health of balance-of-plant mechanical assets.\u003c\/p\u003e\n\n\u003cp\u003eThe hermetically sealed 316L stainless steel housing guarantees robust performance in demanding industrial settings. Please note that the manufacturer has designated the 177230-01-01-CN seismic transmitter as a replacement model for legacy 177230-02 configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides a direct 4 to 20 mA DC velocity output for direct PLC and DCS interface.\u003c\/li\u003e\n  \u003cli\u003eConstructed with a rugged, corrosion-resistant 316L stainless steel housing.\u003c\/li\u003e\n  \u003cli\u003eIntegral 3-pin MIL-C-5015 electrical connector for secure, industrial-grade wiring.\u003c\/li\u003e\n  \u003cli\u003eSimple loop-powered installation eliminates the need for dedicated transmitter monitors.\u003c\/li\u003e\n  \u003cli\u003eHermetically sealed design for maximum reliability in wet, dusty, or corrosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCooling tower fan monitoring\u003c\/li\u003e\n  \u003cli\u003eCentrifugal pumps and industrial compressors\u003c\/li\u003e\n  \u003cli\u003eElectric motors and gearboxes\u003c\/li\u003e\n  \u003cli\u003eBalance of Plant (BOP) machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth\u003eManufacturer\u003c\/th\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003ePart Number\/Model\u003c\/th\u003e\n      \u003ctd\u003e177230-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProduct Type\u003c\/th\u003e\n      \u003ctd\u003eSeismic Transmitter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMeasurement Range\u003c\/th\u003e\n      \u003ctd\u003e0 to 50.8 mm\/s (0 to 2.0 in\/s) velocity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOutput Signal\u003c\/th\u003e\n      \u003ctd\u003e4 to 20 mA DC (loop-powered)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOperating Temperature Range\u003c\/th\u003e\n      \u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eElectrical Isolation\u003c\/th\u003e\n      \u003ctd\u003eGreater than 10^8 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003ctd\u003e3-pin MIL-C-5015, 316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCase Material\u003c\/th\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eHeight\u003c\/th\u003e\n      \u003ctd\u003e66.0 mm (2.60 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eDiameter\u003c\/th\u003e\n      \u003ctd\u003e25.4 mm (1.00 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eWeight\u003c\/th\u003e\n      \u003ctd\u003e0.131 kg (0.29 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure accurate vibration measurements, mount the transmitter on a clean, flat surface that has been machined to a high finish. Utilize the specified mounting stud and apply the recommended torque to ensure rigid physical coupling with the machinery casing. Route the cabling away from high-voltage motor supply lines to minimize electromagnetic interference, and utilize appropriate shielding techniques with the 3-pin MIL-C-5015 connector.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668296135019,"sku":"177230-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/177230-02-azx2m5nntdi_07c352c7-239b-4917-9187-3286e3925484.jpg?v=1765520397"},{"product_id":"991-06-50-01-00-bently-nevada-991-thrust-transmitter","title":"991-06-50-01-00 | Bently Nevada | 991 Thrust Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e991-06-50-01-00\u003c\/strong\u003e is a thrust position transmitter designed for continuous shaft axial displacement monitoring in rotating machinery systems. It converts proximity probe signals into a proportional industrial output for integration with turbine supervisory instrumentation, machinery protection systems, and distributed control systems.\u003c\/p\u003e\n\u003cp\u003eThe transmitter supports thrust measurement applications in steam turbines, compressors, pumps, and other critical rotating assets where axial shaft movement monitoring is required. The unit is compatible with proximity probe systems using a 5.0 metre system length configuration and supports DIN-rail installation for industrial control panels.\u003c\/p\u003e\n\u003cp\u003eDesigned for machinery condition monitoring environments, the \u003cstrong\u003e991 Thrust Transmitter\u003c\/strong\u003e provides reliable signal conditioning and simplified integration into plant monitoring architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous axial thrust position monitoring\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting configuration\u003c\/li\u003e\n\u003cli\u003e0 to 0.6 mm full-scale measurement range\u003c\/li\u003e\n\u003cli\u003eCompatible with 5.0 metre probe system length\u003c\/li\u003e\n\u003cli\u003eIndustrial panel installation design\u003c\/li\u003e\n\u003cli\u003eCompact transmitter housing\u003c\/li\u003e\n\u003cli\u003eSuitable for turbine supervisory systems\u003c\/li\u003e\n\u003cli\u003eSupports machinery protection applications\u003c\/li\u003e\n\u003cli\u003ePanel or enclosure integration capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine thrust monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor axial displacement measurement\u003c\/li\u003e\n\u003cli\u003eRotating equipment protection systems\u003c\/li\u003e\n\u003cli\u003eTurbine supervisory instrumentation systems\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery monitoring panels\u003c\/li\u003e\n\u003cli\u003eOil and gas rotating equipment\u003c\/li\u003e\n\u003cli\u003ePower generation facilities\u003c\/li\u003e\n\u003cli\u003eProcess industry condition monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-06\u003c\/td\u003e\n\u003ctd\u003e0 to 0.6 mm full-scale option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-50\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet) system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eAgency approval not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e991-06-50-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 0.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height Without DIN Clip\u003c\/td\u003e\n\u003ctd\u003e42.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Distance (W x L)\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Lead Time\u003c\/td\u003e\n\u003ctd\u003e12 - 18 Weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter on a properly grounded 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eRoute probe and signal cables separately from high-voltage wiring.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling to reduce EMI and RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify probe system length compatibility before commissioning.\u003c\/li\u003e\n\u003cli\u003eEnsure secure terminal connections during installation.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive vibration or moisture exposure inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eConfirm proper polarity and signal wiring before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 991 transmitter measure?\u003c\/strong\u003e\u003cbr\u003eIt monitors axial shaft displacement in rotating machinery applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the full-scale measurement range?\u003c\/strong\u003e\u003cbr\u003eThe configured range is 0 to 0.6 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich mounting method is used?\u003c\/strong\u003e\u003cbr\u003eThe unit uses 35 mm DIN-rail clips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system length is supported by this model?\u003c\/strong\u003e\u003cbr\u003eThis version supports a 5.0 metre probe system length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the transmitter be installed in control cabinets?\u003c\/strong\u003e\u003cbr\u003eYes. The compact housing is suitable for industrial panel installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device suitable for turbine monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in turbine supervisory systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit include hazardous area approvals?\u003c\/strong\u003e\u003cbr\u003eNo approvals are specified for this configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat industries commonly use this transmitter?\u003c\/strong\u003e\u003cbr\u003ePower generation, oil and gas, and process industries frequently use it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of machinery can use this transmitter?\u003c\/strong\u003e\u003cbr\u003eSteam turbines, compressors, pumps, and other rotating assets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter compatible with machinery protection systems?\u003c\/strong\u003e\u003cbr\u003eYes. It can interface with machinery monitoring and protection platforms.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668299411819,"sku":"991-06-50-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/991-06-50-01-00-mrx1sfku4cs_16f417d9-abde-4564-9871-1a1dac0d35d6.jpg?v=1765520501"},{"product_id":"991-25-70-01-cn-bently-nevada-991-thrust-transmitter","title":"991-25-70-01-CN | Bently-Nevada | 991 Thrust Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e991-25-70-01-CN\u003c\/strong\u003e is a 2-wire, loop-powered thrust transmitter designed to provide a proportional 4 to 20 mA axial displacement signal for rotating machinery monitoring applications. It accepts input from a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and matching extension cable, then conditions the signal into engineering units proportional to shaft axial position for machinery control and protection systems.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e991 Thrust Transmitter\u003c\/strong\u003e integrates the Proximitor Sensor within the transmitter housing, eliminating the need for an external unit. It provides non-isolated PROX OUT and COM outputs for dynamic vibration and gap voltage diagnostics, supporting machinery analysis and troubleshooting.\u003c\/p\u003e\n\u003cp\u003eThe transmitter is suitable for centrifugal air compressors, pumps, motors, and fans where compact installation space and continuous thrust position indication are required. Compatibility with the \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e allows installation in small clearance areas typical of centrifugal compressor systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-wire loop-powered transmitter\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA proportional thrust position output\u003c\/li\u003e\n\u003cli\u003eIntegrated Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 NSv proximity probe systems\u003c\/li\u003e\n\u003cli\u003eNon-isolated PROX OUT diagnostic signal\u003c\/li\u003e\n\u003cli\u003eCoaxial connector for vibration diagnostics\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustments\u003c\/li\u003e\n\u003cli\u003eTest Input pin for loop verification\u003c\/li\u003e\n\u003cli\u003ePower-up inhibit circuit\u003c\/li\u003e\n\u003cli\u003eNot OK\/Signal Defeat protection circuit\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting support\u003c\/li\u003e\n\u003cli\u003ePotted construction for high humidity environments\u003c\/li\u003e\n\u003cli\u003eSuitable for 100% condensing environments\u003c\/li\u003e\n\u003cli\u003eSupports compact installation areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eSmall industrial pumps\u003c\/li\u003e\n\u003cli\u003eRotating machinery monitoring\u003c\/li\u003e\n\u003cli\u003eMotor thrust position measurement\u003c\/li\u003e\n\u003cli\u003eFan shaft displacement monitoring\u003c\/li\u003e\n\u003cli\u003eOEM machinery control systems\u003c\/li\u003e\n\u003cli\u003eTurbine auxiliary systems\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems\u003c\/li\u003e\n\u003cli\u003eCondition monitoring panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-70\u003c\/td\u003e\n\u003ctd\u003e7.0 metres (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eChina explosion-proof certification NEPSI\/CCC\/ATEX\/IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e991-25-70-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThrust Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e1 non-contacting 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-1.5% full scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohm including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero and Span Adjustment\u003c\/td\u003e\n\u003ctd\u003eNon-interacting external adjustments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot OK\/Signal Defeat Response\u003c\/td\u003e\n\u003ctd\u003eOutput less than 3.6 mA within 100 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Recovery Time\u003c\/td\u003e\n\u003ctd\u003eRestored within 0.1 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0.25 to 1.65 mm (10 to 65 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProx Out Incremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/um (200 mV\/mil) +\/-6.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-10% from 0 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeadwire Length\u003c\/td\u003e\n\u003ctd\u003e3 metres maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Distance Non-Hazardous Areas\u003c\/td\u003e\n\u003ctd\u003e13 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Distance Intrinsically Safe Areas\u003c\/td\u003e\n\u003ctd\u003e68 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Armor\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 SST optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength\u003c\/td\u003e\n\u003ctd\u003e222 N maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e53.3 mm x 73.9 mm x 100.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Height Without DIN Clip\u003c\/td\u003e\n\u003ctd\u003e42.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Distance (W x L)\u003c\/td\u003e\n\u003ctd\u003e63.5 mm x 69.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e5.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Classification\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C approval in North America and VDE approval in Europe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEurope Marking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration and gap voltage signal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Input\u003c\/td\u003e\n\u003ctd\u003eLoop signal verification input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBNC Connector\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor diagnostic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter on a grounded 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eMaintain proper probe gap adjustment during commissioning.\u003c\/li\u003e\n\u003cli\u003eSeparate probe cables from high-voltage power wiring.\u003c\/li\u003e\n\u003cli\u003eUse shielded cable routing practices to reduce EMI and RFI interference.\u003c\/li\u003e\n\u003cli\u003eProtect coaxial connectors from moisture exposure.\u003c\/li\u003e\n\u003cli\u003eVerify loop power supply voltage before startup.\u003c\/li\u003e\n\u003cli\u003eUse the 122115-01 Test Adapter when connecting grounded AC-powered diagnostic equipment.\u003c\/li\u003e\n\u003cli\u003eEnsure proper signal isolation during machinery diagnostics.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive mechanical stress on probe lead connections.\u003c\/li\u003e\n\u003cli\u003eConfirm correct polarity before energizing the loop circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA\/NRTL\/C\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Approval for North America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVDE\u003c\/td\u003e\n\u003ctd\u003eEurope approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eEuropean CE marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEPSI\u003c\/td\u003e\n\u003ctd\u003eChina explosion-proof certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC\u003c\/td\u003e\n\u003ctd\u003eChina Compulsory Certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eHazardous area certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eInternational hazardous area certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of this transmitter?\u003c\/strong\u003e\u003cbr\u003eIt converts axial shaft displacement into a proportional 4 to 20 mA signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich probe system is compatible with this model?\u003c\/strong\u003e\u003cbr\u003eThe transmitter is designed for use with the 3300 NSv proximity probe system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the transmitter require an external Proximitor unit?\u003c\/strong\u003e\u003cbr\u003eNo. The Proximitor Sensor is integrated into the transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output signal does the device provide?\u003c\/strong\u003e\u003cbr\u003eIt provides a 4 to 20 mAdc industry-standard signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PROX OUT signal be used for diagnostics?\u003c\/strong\u003e\u003cbr\u003eYes. The PROX OUT connection supports vibration and gap voltage diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting method does this configuration use?\u003c\/strong\u003e\u003cbr\u003eThis model uses 35 mm DIN-rail clips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter suitable for humid environments?\u003c\/strong\u003e\u003cbr\u003eYes. The potted construction supports 100% condensing environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during a Not OK condition?\u003c\/strong\u003e\u003cbr\u003eThe output drops below 3.6 mA within 100 microseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan grounded test equipment connect directly to PROX OUT?\u003c\/strong\u003e\u003cbr\u003eThe manual recommends using the 122115-01 Test Adapter for signal isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat industries commonly use this transmitter?\u003c\/strong\u003e\u003cbr\u003eOil and gas, power generation, and industrial rotating machinery applications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301672811,"sku":"991-25-70-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/991-25-70-01-CN-p3q31sowur5_71146f97-f12b-4430-9a6f-1ccb5ce0c52c.jpg?v=1765520558"},{"product_id":"bently-nevada-990-05-70-01-cn-990-series-2-wire-vibration-transmitter","title":"Bently Nevada 990-05-70-01-CN 990 Series 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for integration into PLC, DCS, and safety-instrumented machinery protection systems, the \u003cstrong\u003eBently Nevada 990-05-70-01-CN\u003c\/strong\u003e provides continuous proportional radial vibration monitoring via a robust 2-wire current loop. This transmitter conditions signals directly from a compatible proximity probe system to output a standard 4-20 mA analog signal, removing the need for dedicated monitor racks in the control architecture. The \u003cstrong\u003e990-05-70-01-CN\u003c\/strong\u003e is factory-calibrated for high-precision machinery diagnostics and features a 35 mm DIN rail mounting footprint for high-density control cabinet integration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e2-Wire Loop Powered:\u003c\/strong\u003e Operates on standard 24 VDC loop power, reducing field wiring complexity and installation costs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous 4-20 mA Output:\u003c\/strong\u003e Delivers a stable analog signal proportional to the overall peak-to-peak radial vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Prox Input:\u003c\/strong\u003e Interfaces directly with a 3300 NSv proximity transducer system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Factory fitted with 35 mm DIN rail clips for secure, space-efficient control room mounting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolid State Design:\u003c\/strong\u003e No moving parts or field adjustments required, ensuring long-term measurement stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eCentrifugal and reciprocating air\/gas compressors\u003c\/li\u003e\n  \u003cli\u003eIndustrial draft fans, blowers, and exhausters\u003c\/li\u003e\n  \u003cli\u003eHigh-speed process pumps and electric motors\u003c\/li\u003e\n  \u003cli\u003eSmall-scale steam turbines and gas expanders\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eSKU Segment\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eTechnical Meaning \/ Configuration\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFull-scale Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e05\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 5 mils pp (0 to 125 micrometers pp)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e70\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e01\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e35 mm DIN rail clips installed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCountry-specific approvals (China\/CN zone compliance)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e990-05-70-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Sensor Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3300 NSv Proximity Transducer System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Requirement\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12 to 35 VDC (Loop voltage at transmitter terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAnalog Output Signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4-20 mA (proportional to peak-to-peak vibration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Calibrated Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.0 meters (including probe, extension cable, and transmitter)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-35 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kg (3.3 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15.2 cm x 12.7 cm x 10.2 cm (6.0 in x 5.0 in x 4.0 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eTerminal \/ Connection\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eDesignation\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eFunctional Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e+ \/ Loop\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePower positive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+12 to +35 VDC Supply Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e- \/ Return\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4-20 mA current output and return line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSensor Common\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCommon reference terminal for proximity probe return\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePROX\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProbe Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRaw dynamic signal input from 3300 NSv probe\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSHIELD\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGrounding Shield\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTo prevent EMI noise; terminate at the instrument end only\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis transmitter is strictly calibrated to be compatible with a 3300 NSv proximity probe configuration. It cannot be used with standard 3300 XL 8mm or 5mm probes because of different scale factors and sensor gap behaviors. Ensure that the total system length (probe plus extension cable) matches the 7.0-meter configuration specification exactly; mismatching system lengths will result in linearity and scaling calibration errors.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that the 4-20 mA loop resistance is matched to the input voltage. If the voltage drops below 12 VDC at the transmitter terminal block during a maximum 20 mA loop excursion, the transmitter output will clamp, skewing high-vibration alarms. Avoid routing high-voltage motor power leads in parallel with the 990 transmitter cabling inside cable trays to prevent inductive noise injection.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring commissioning, verify the loop current with a high-accuracy digital multimeter in series with the return terminal. A static loop current of approximately 4.0 mA indicates a zero-vibration condition, whereas a current under 3.6 mA indicates a field sensor fault, probe disconnect, or open-circuit loop connection.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all associated loop power sources and instrument systems before performing mechanical mounting or field wiring terminations. Failure to isolate power lines can result in control loop short-circuits or accidental tripping of safety interlocks on critical rotating machinery.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the 990-05-70-01-CN onto a rigid 35 mm DIN rail inside a dry, low-vibration enclosure to minimize thermal drift and atmospheric contamination.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 3300 NSv proximity probe coaxial connector or cable to the designated PROX and COM terminal blocks using correct insulation and torque limits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRoute shielded, twisted-pair field cables to the + and - loop terminals, and connect the shield wire to the DCS or PLC instrumentation ground terminal only.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eApply 24 VDC loop power and verify loop current baseline performance at 4 mA with the machine in a shut-down, vibration-free state.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302426475,"sku":"990-05-70-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-05-70-01-CN-s0zjq0dbtam_f7346470-1d9f-479f-91eb-be930d127408.jpg?v=1765520583"},{"product_id":"bently-nevada-177230-00-01-cn-seismic-transmitter","title":"Bently Nevada 177230-00-01-CN Seismic Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating directly into PLC, DCS, or SCADA control architectures, the \u003cstrong\u003eBently Nevada 177230-00-01-CN\u003c\/strong\u003e serves as a loop-powered seismic transmitter designed for continuous vibration monitoring of industrial rotating machinery. This velocity-based transmitter utilizes a piezo-electric accelerometer with onboard signal conditioning to produce a \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e analog output proportional to the overall vibration velocity. Encased in a rugged, hermetically sealed \u003cstrong\u003e316L stainless steel\u003c\/strong\u003e housing, it is engineered for long-term deployment in high-reliability industrial environments, providing immediate protection and diagnostics for balance-of-plant assets.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Interface:\u003c\/strong\u003e Eliminates the need for specialized monitoring monitors by transmitting a direct 4 to 20 mA loop-powered signal to any standard input card.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHermetic Seal:\u003c\/strong\u003e Built with 316L stainless steel housing and a 3-pin MIL-C-5015 top connector, guaranteeing ingress protection in high-moisture settings up to 100% relative humidity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fidelity Signal:\u003c\/strong\u003e Onboard electronics process raw piezo-electric charge output to accurately represent vibration velocity across the defined frequency band.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolid-State Durability:\u003c\/strong\u003e No moving internal components, minimizing wear-and-tear drift and ensuring consistent, long-term calibration stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eBalance-of-plant rotating machinery, including industrial fans and blowers.\u003c\/li\u003e\n  \u003cli\u003eContinuous monitoring of centrifugal and reciprocating fluid pumps.\u003c\/li\u003e\n  \u003cli\u003eMedium-to-large electric motors, generators, and auxiliary gearboxes.\u003c\/li\u003e\n  \u003cli\u003eAir and process gas compressors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0; font-family: inherit;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePart Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e177230-00-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMeasurement Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 12.7 mm\/s (0 to 0.5 in\/s) RMS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eFrequency Response\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 Hz to 1 kHz (600 to 60,000 cpm) RMS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 to 20 mA DC (loop-powered)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eApprovals Option Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCN (China-specific industrial and hazardous area approvals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTo 100% non-submerged\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCase Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e316L Stainless Steel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-pin MIL-C-5015, 316L Stainless Steel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMounting Thread\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1\/4-28 UNF\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTransmitter Diameter\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e25.4 mm (1.00 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTransmitter Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e66.0 mm (2.60 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSensor Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.131 kg (0.29 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.50 kg (including secure transit packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0; font-family: inherit;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMIL-C-5015 Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePositive 4 to 20 mA Current Loop (+ TX \/ Power)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNegative 4 to 20 mA Current Loop Return (- TX \/ Common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin C\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eShield \/ Ground Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis transmitter acts as a standardized replacement for legacy case velocity transducers when direct-to-PLC output is desired. Note that the 177230 series outputs a \u003cstrong\u003e4 to 20 mA DC current\u003c\/strong\u003e corresponding to overall root-mean-square (RMS) velocity, meaning it cannot directly drive legacy dynamic vibration monitors (such as Bently Nevada 3500\/42M modules configured for dynamic inputs) without proper module configuration for static analog signals.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDo not mount this transmitter on flexible machine casings or thin plate sections. Doing so can introduce high-frequency structural resonances that do not represent true bearing housing movement, causing false high readings. The sensor must be bolted to a solid, flat, machined surface directly on or near the machine's bearing housing to ensure accurate mechanical energy transfer.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo guarantee optimal high-frequency signal coupling, ensure the mounting surface is completely free of debris and paint. Apply a thin layer of silicone grease to the 1\/4-28 UNF mounting stud before installation. Cable runs should be completed using high-quality twisted, shielded pair cabling. Ground the shield at the receiver (PLC\/DCS) chassis ground only to prevent ground loops that cause noise injection on the loop current signal.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore starting mechanical mounting or electrical wiring, ensure the monitored rotating asset is fully de-energized and locked out. Keep loop power supply disconnected until all wiring is physically terminated to prevent electrical shocks or component damage in hazardous areas.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePrepare a flat, spot-faced area with a diameter of at least 25.4 mm (1.00 in) on the bearing housing.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eDrill and tap a vertical mounting hole perpendicular to the machined surface using a 1\/4-28 UNF tap, minimum depth 12 mm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTorque the transmitter to 9.9 N-m (88 in-lb) using a calibrated torque wrench. Do not overtighten, as this can degrade internal crystal elements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 3-pin MIL-C-5015 cable connector and secure the locking collar. Run the cable through conduit to protect against mechanical abrasions.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303311211,"sku":"177230-00-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/177230-00-01-CN-rkkyl3z5rxi_84f4d4f0-806e-41a2-95da-f782692026ab.jpg?v=1765520612"},{"product_id":"990-05-50-02-00-bently-nevada-990-vibration-transmitter","title":"990-05-50-02-00 | Bently Nevada | 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis two-wire, loop-powered device is designed to interface with a non-contacting \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e and its matching extension cable. The \u003cstrong\u003e990-05-50-02-00\u003c\/strong\u003e conditions the incoming proximity sensor signal into appropriate peak-to-peak vibration amplitude engineering units, converting it into a proportional 4 to 20 mA industry-standard current loop output. This analog output is transmitted directly to a machinery control system, such as a PLC or DCS, where standard protection alarming and machinery logic are performed.\u003c\/p\u003e\n\u003cp\u003eThe unit integrates the functionality of a \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e directly into its housing, requiring no separate external driver. It features a non-isolated \u003cstrong\u003ePROX OUT\u003c\/strong\u003e coaxial connector and terminal block connection to supply a dynamic vibration and gap voltage signal for troubleshooting and machinery diagnostic operations. Built with potted construction, the device provides robust environmental protection suitable for highly humid or condensing locations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor:\u003c\/strong\u003e Combines full proximity probe driver capabilities inside the transmitter housing to eliminate external signal conditioning modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 4 to 20 mA Output:\u003c\/strong\u003e Transmits a continuous analog current loop proportional to peak-to-peak vibration amplitude over a standard two-wire configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Interfaces:\u003c\/strong\u003e Provides non-isolated \u003cstrong\u003ePROX OUT\u003c\/strong\u003e and COM terminals plus an integrated coaxial connector for direct connection to diagnostic tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Not OK \/ Signal Defeat Circuit:\u003c\/strong\u003e Drops the loop current output to less than 3.6 mA within 100 microseconds of a probe or cable fault to prevent false control system alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Interacting Field Adjustments:\u003c\/strong\u003e Accessible zero and span potentiometers underneath the device label facilitate straightforward field loop adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Test Input Pin:\u003c\/strong\u003e Allows for rapid on-site verification of the loop output current by using an external function generator as the input signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotted Enclosure Construction:\u003c\/strong\u003e Fully sealed housing protects internal electronic components against up to 100% condensing humidity conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors\u003c\/li\u003e\n\u003cli\u003eSmall industrial pumps\u003c\/li\u003e\n\u003cli\u003eElectric motor machinery monitoring\u003c\/li\u003e\n\u003cli\u003eCooling and ventilation fans\u003c\/li\u003e\n\u003cli\u003eOEM machinery control system integration\u003c\/li\u003e\n\u003cli\u003eOverall vibration trending and peak-to-peak amplitude data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFull-Scale Option (AA)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSystem Length Option (BB)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMounting Option (CC)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAgency Approval Option (DD)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e990-05-50-02-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e05 (0-5 mils pp \/ 0-125 um pp)\u003c\/td\u003e\n\u003ctd\u003e50 (5.0 meters \/ 16.4 feet)\u003c\/td\u003e\n\u003ctd\u003e02 (Bulkhead screws)\u003c\/td\u003e\n\u003ctd\u003e00 (Not required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eSpecifications apply at +22 Celsius (+72 Fahrenheit) using a 3300 NSv Probe and Extension Cable, and an AISI 4140 steel target unless specified otherwise.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Values\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Requirements\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc input at the transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mAdc over specified full-scale range (2-wire configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±1.5% over specified full-scale range across 250 Ohm loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ohm including cable at 35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower-up Inhibit\u003c\/td\u003e\n\u003ctd\u003eSignal output stays below 3.6 mA for 2 to 3 seconds after power application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx Out Linear Range\u003c\/td\u003e\n\u003ctd\u003e1.4 mm (55 mils), starting approx 0.25 mm (10 mils) from target surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 mV\/um (200 mV\/mil) ±6.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm output impedance calibrated for a 10 MOhm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz +0, -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTypical Noise Level\u003c\/td\u003e\n\u003ctd\u003e50 mV pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 Celsius to +85 Celsius (-31 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 Celsius to +100 Celsius (-62 Fahrenheit to +212 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submerged (requires coaxial connector protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransducer Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100.1 mm x 73.9 mm x 42.6 mm (3.94 in x 2.91 in x 1.68 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTarget Requirements\u003c\/td\u003e\n\u003ctd\u003eMinimum 9.5 mm (0.375 in) diameter, AISI 4140 steel target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply (+) \/ 4 to 20 mA loop input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply (-) \/ Loop return connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROX OUT dynamic signal terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal E4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOM terminal reference for PROX OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ2 BNC Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial PROX OUT dynamic transducer signal for portable diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ3 Coaxial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput connection from the 3300 NSv proximity probe extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Specifications:\u003c\/strong\u003e Use 1.0 mm2 (18 AWG), 2-conductor, twisted, shielded cable for the 4 to 20 mA current loop and field terminal connections. The maximum loop cable run distance is 13 km (8 miles).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e Maintain a minimum voltage of +17 Vdc at the transmitter terminal when accounting for full loop resistance to prevent clipping at the 20 mA limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Ensure the matched 3300 NSv proximity probe is gapped between 0.5 mm and 1.75 mm (20 and 55 mils) from the target surface during installation to ensure valid full-scale operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Instrument Isolation:\u003c\/strong\u003e The PROX OUT signal is not electrically isolated from the 4 to 20 mA loop. Do not connect grounded, AC-powered test equipment directly to the BNC or terminal strips as it will cause loop interference or false trips. Connect via a 122115-01 Test Adapter to safely isolate and invert the signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulkhead Mounting Alignment:\u003c\/strong\u003e Mount the transmitter base securely to a flat surface using the four integrated bulkhead mounting holes and the supplied 6-32 x 1.326 screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e Install connector protector sleeves over all ClickLoc coaxial junctions to maintain sealing integrity in environments subject to high humidity or condensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2, EN 61000-6-4, and EMC Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e ATEX Directive 2014\/34\/EU; Ex ia IIC T4 Ga, and Ex ec IIC T4 Gc (Ta = -30 Celsius to +85 Celsius).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU and China RoHS with a 15-year EFUP designation under SJ\/T 11364-2024.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e ABS 2009 Steel Vessels Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Approvals:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, D (T5 @ Ta = +85 Celsius, Type 4 Enclosure).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the behavior of the output loop current when a proximity probe is damaged or disconnected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter is equipped with an internal Not OK and Signal Defeat circuit. If a faulty probe or open connection is experienced, the loop output current automatically drops to less than 3.6 mA within 100 microseconds to suppress false machine alarms in the control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run standard plant diagnostic software using the 4 to 20 mA output of this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4 to 20 mA signal provides overall peak-to-peak trending data only and is not compatible with plant-wide dynamic diagnostic systems like System 1. The analog output cannot determine the phase of vibration or handle specialized parameters like gap alarms or Trip Multiply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is an external test adapter required when connecting an oscilloscope to the PROX OUT terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PROX OUT signal shares a common ground reference with the non-isolated 4 to 20 mA loop current. Connecting grounded, AC-powered diagnostic tools directly to the transmitter can alter the loop current and cause accidental machinery shutdowns, so an isolating test adapter must be used\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303540587,"sku":"990-05-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-05-50-02-00-q0sixid00vm_a524031d-e1ba-4b33-abbc-40a31b60a4e9.jpg?v=1765520623"},{"product_id":"bently-nevada-990-04-70-01-cn-990-series-2-wire-vibration-transmitter","title":"Bently Nevada 990-04-70-01-CN 990 Series 2-Wire Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for seamless integration into industrial machinery protection systems, the \u003cstrong\u003eBently Nevada 990-04-70-01-CN\u003c\/strong\u003e functions as a high-precision, loop-powered sensor interface designed to continuously monitor shaft vibration. This 2-wire transmitter converts the dynamic displacement signal from a proximity probe system into a standard 4-20 mA analog current loop, facilitating direct communication with programmable logic controllers (PLCs), distributed control systems (DCSs), or machine condition monitoring platforms. \n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed for rugged industrial environments, this unit simplifies field wiring by combining the proximitor sensor electronics and transmitter functionality into a single, compact housing. The \u003cstrong\u003e990-04-70-01-CN\u003c\/strong\u003e is factory-configured for a 0-4 mils peak-to-peak measurement range, optimized for a 7.0-meter system length, and equipped with quick-install DIN rail mounting clips.\n\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Design:\u003c\/strong\u003e Merges proximity probe driver circuitry with 4-20 mA transmitter loops to minimize total component count in monitoring panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoop-Powered 2-Wire Interface:\u003c\/strong\u003e Reduces wiring costs and installation complexity by utilizing the same pair of conductors for both signal transmission and operating power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Contacting Displacement Measurement:\u003c\/strong\u003e Interfaces with standard eddy current proximity probes to measure dynamic shaft movement without physical contact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Buffered Output:\u003c\/strong\u003e Provides a raw dynamic signal via a coaxial connector for diagnostic access and vibration analysis with portable instruments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Noise Immunity:\u003c\/strong\u003e Robust shielding and isolation prevent electromagnetic interference in high-power motor and turbine environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eRadial vibration monitoring on centrifugal air and gas compressors.\u003c\/li\u003e\n  \u003cli\u003eCasing and shaft vibration monitoring of industrial steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eOverhung fan shaft displacement tracking in cooling towers.\u003c\/li\u003e\n  \u003cli\u003eContinuous condition monitoring of heavy-duty process pumps.\u003c\/li\u003e\n  \u003cli\u003eBalance-of-plant rotating machinery protection where full rack systems are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Suffix Configuration\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eSuffix Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOption Class\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eTechnical Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-04\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eFull-Scale Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 4 mils pp (0 to 100 micrometers peak-to-peak)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-70\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSystem Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.0 meters (23.0 feet) total electrical length\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Hardware\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e35 mm DIN rail clips pre-installed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-CN\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRegion-specific safety certifications (China\/Asia-Pacific)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.9rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e990 Vibration Transmitter Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFull-Scale Input Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 4 mils peak-to-peak (0 to 100 um pp)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Signal Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 to 20 mA DC (proportional to full scale)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12 to 35 VDC (at the transmitter terminal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMaximum Loop Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRLoop = (VSupply - 12V) \/ 0.02A ohms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRequired Probe Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3300 XL 8mm proximity probe (or verified equivalent)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTarget Calibration Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAISI 4140 steel (standard target configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-35 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 to +100 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kg (approx. 3.3 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; width: 30%;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eLabel \/ Standard Marker\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eFunction \u0026amp; Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+ \/ PWR\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePositive supply voltage connection (4-20 mA Loop +)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e- \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSignal return connection (4-20 mA Loop -)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSHD\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInstrumentation shield tie-point (internally isolated from DIN rail)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCoaxial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBUF\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCoaxial buffered raw voltage output (approx. 7.87 V\/mm scale)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003e990-04-70-01-CN\u003c\/strong\u003e requires an absolute electrical system length match of 7.0 meters. Do not mix and match with 5.0-meter probe configurations (such as the -50 options) or non-3300 XL systems without recalibrating, as mismatching will cause extreme signal non-linearity and scale factor errors. \n\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  In highly active electromagnetic environments (e.g., adjacent to variable frequency drives), a common error is allowing the transmitter housing to float electrically. Ensure the 35 mm DIN rail has a direct, low-impedance ground path. Additionally, calculate loop resistance strictly using the minimum expected voltage supply at the cabinet to prevent transmitter dropout at full-scale signal levels (20 mA peaks).\n\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When wiring the coaxial sensor extension cable, protect the connector with self-fusing silicone tape or heat-shrink tubing to prevent moisture ingress. Liquid intrusion at the probe-to-extension cable joint alters loop impedance, showing up on the DCS as false high vibration or erratic signal spikes.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #742a2a; font-size: 0.95rem;\"\u003e\n    Before installing, removing, or performing maintenance on the transmitter, de-energize all connected electrical loops. Ensure the ambient atmosphere is certified non-hazardous or that proper intrinsically safe barriers are active if deploying this -CN model in classified field areas.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Mount the unit firmly onto standard 35 mm symmetric DIN rail (EN 50022) using the integrated -01 mounting clips. Ensure the rail is bonded to a noise-free industrial ground.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Connect the 7.0-meter proximity probe coaxial cable system to the integrated coaxial input connector on the transmitter. Hand-tighten the coupling, then snug-tighten to prevent vibration loosening.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Route a shielded, twisted-pair instrument cable from the 4-20 mA loop controller to the transmitter terminal block. Terminate +PWR to Pin 1, -SIG to Pin 2, and the cable shield to Pin 3 (SHD).\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003e\n      Apply loop power (typically 24 VDC) and verify quiescent loop current draws approximately 4 mA under static (no-vibration, gapped probe) conditions.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303573355,"sku":"990-04-70-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-04-70-01-CN-t1ekda5ofh1_2f500447-913f-494b-9a07-4299a6e98c83.jpg?v=1765520624"},{"product_id":"bently-nevada-990-04-70-01-00-990-vibration-transmitter","title":"Bently Nevada 990-04-70-01-00 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-04-70-01-00\u003c\/strong\u003e vibration transmitter provides a simplified method for integrating shaft vibration monitoring into industrial automation systems. Developed by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e, the unit converts vibration measurements from a 3300 NSv proximity probe into a linear 4 to 20 mA output signal for machine protection and condition monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThis transmitter configuration is commonly installed on rotating equipment where continuous vibration trending is required without deploying a full rack-based monitoring system. The compact housing and DIN rail mounting arrangement support installation inside OEM control cabinets, compressor skids, and packaged machinery panels.\u003c\/p\u003e\n\u003cp\u003eThe transmitter operates from a standard DC loop supply and combines the Proximitor electronics and signal conditioning circuitry into a single encapsulated assembly. Maintenance personnel can also access dynamic vibration information through the PROX OUT connection during commissioning and troubleshooting procedures.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e0-4 mils pp\u003c\/strong\u003e full-scale range makes this version suitable for machinery applications requiring tighter vibration measurement resolution.\u003c\/p\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous vibration signal conversion\u003c\/li\u003e\n\u003cli\u003eLinear 4 to 20 mA output transmission\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 NSv transducer systems\u003c\/li\u003e\n\u003cli\u003eIntegrated Proximitor functionality\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting design\u003c\/li\u003e\n\u003cli\u003eDynamic vibration signal access\u003c\/li\u003e\n\u003cli\u003eCompact encapsulated transmitter body\u003c\/li\u003e\n\u003cli\u003eExternal calibration adjustments\u003c\/li\u003e\n\u003cli\u003eProbe fault indication logic\u003c\/li\u003e\n\u003cli\u003eLow-maintenance two-wire configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Industrial Uses\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication Area\u003c\/th\u003e\n\u003cth\u003eTypical Equipment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil and gas systems\u003c\/td\u003e\n\u003ctd\u003eCompressors and auxiliary pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing plants\u003c\/td\u003e\n\u003ctd\u003eElectric motors and blowers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtility operations\u003c\/td\u003e\n\u003ctd\u003eCooling water pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess industries\u003c\/td\u003e\n\u003ctd\u003eRotating process machinery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM equipment packages\u003c\/td\u003e\n\u003ctd\u003eIntegrated monitoring panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance programs\u003c\/td\u003e\n\u003ctd\u003eMachine vibration trending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eSelection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990 - Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Option\u003c\/td\u003e\n\u003ctd\u003e04 = 0-4 mils pp (0-100 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e70 = 7.0 metres (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e01 = 35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00 = Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e990-04-70-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e1 non-contacting 3300 NSv proximity probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-4 mils pp (0-100 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e7.0 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnection Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Input\u003c\/td\u003e\n\u003ctd\u003eConnection for 3300 NSv probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Power Terminal\u003c\/td\u003e\n\u003ctd\u003eLoop power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA vibration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eDynamic diagnostic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon signal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Recommendations\u003c\/h3\u003e\n\u003cp\u003eInstall the transmitter in a vibration-protected control enclosure with adequate grounding and cable shielding practices. The DIN rail mounting arrangement allows quick integration into existing automation panels.\u003c\/p\u003e\n\u003cp\u003eSeparate low-level transducer wiring from high-current motor cables to reduce electromagnetic interference. During startup, verify the probe gap and confirm stable loop current before placing the machine into service.\u003c\/p\u003e\n\u003cp\u003eFor diagnostic waveform measurements, use suitable isolated monitoring equipment connected to the PROX OUT interface. Protect exposed connectors from excessive moisture and contamination in high-humidity process environments.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat measurement range does this configuration use?\u003c\/strong\u003e\u003cbr\u003eThis model uses a 0-4 mils peak-to-peak vibration range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich probe series is compatible with the transmitter?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 NSv proximity probe systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the unit be mounted inside a standard control cabinet?\u003c\/strong\u003e\u003cbr\u003eYes. The transmitter includes DIN rail mounting clips for panel installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output signal is provided to the control system?\u003c\/strong\u003e\u003cbr\u003eThe transmitter outputs a proportional 4 to 20 mA vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter suitable for compressor monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used on centrifugal compressors and auxiliary rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this version include hazardous area certification?\u003c\/strong\u003e\u003cbr\u003eNo. The -00 approval option indicates standard non-hazardous configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply range is required?\u003c\/strong\u003e\u003cbr\u003eThe transmitter operates from +12 to +35 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan maintenance teams access dynamic vibration signals?\u003c\/strong\u003e\u003cbr\u003eYes. Diagnostic signals are available through the PROX OUT connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the supplied system cable length?\u003c\/strong\u003e\u003cbr\u003eThis configuration uses a 7.0 metre system length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the transmitter installed?\u003c\/strong\u003e\u003cbr\u003eThe unit mounts directly onto a 35 mm DIN rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the transmitter designed for continuous monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It supports ongoing vibration trending in industrial machinery systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environmental conditions can the unit withstand?\u003c\/strong\u003e\u003cbr\u003eThe transmitter operates in temperatures from -35 degC to +85 degC.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308390251,"sku":"990-04-70-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-04-70-01-00-qlanuhvxffo_ce339ec9-b0bc-48b5-9374-af5386332e0c.jpg?v=1765520752"},{"product_id":"990-05-70-02-cn-bently-nevada-990-vibration-transmitter","title":"990-05-70-02-CN | Bently Nevada | 990 Vibration Transmitter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e990 vibration transmitter\u003c\/strong\u003e converts proximity probe displacement into a proportional \u003cstrong\u003e4–20 mA vibration signal\u003c\/strong\u003e for continuous monitoring of rotating machinery. It is designed for compact OEM installations where vibration indication is required for control logic rather than full diagnostic analysis.\u003c\/p\u003e\n\u003cp\u003eThis configuration (\u003cstrong\u003e990-05-70-02-CN\u003c\/strong\u003e) uses a bulkhead-mounted housing and supports a 7.0 meter probe system length based on the \u003cstrong\u003e3300 NSv proximity probe platform\u003c\/strong\u003e. The measurement output represents peak-to-peak vibration amplitude under steady-state operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe transmitter is typically installed close to machinery skid assemblies or panel structures where rigid mounting is preferred. Signal conditioning is fully integrated, eliminating the need for external Proximitor modules.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire loop-powered vibration transmitter\u003c\/li\u003e\n\u003cli\u003e4–20 mA proportional vibration output\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 NSv proximity probe system\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning electronics\u003c\/li\u003e\n\u003cli\u003eBulkhead screw mounting configuration\u003c\/li\u003e\n\u003cli\u003eExternal zero and span adjustment capability\u003c\/li\u003e\n\u003cli\u003ePROX OUT diagnostic signal access\u003c\/li\u003e\n\u003cli\u003ePower-up inhibit and NOT OK fault indication\u003c\/li\u003e\n\u003cli\u003eDesigned for OEM machinery protection loops\u003c\/li\u003e\n\u003cli\u003eSuitable for compact installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial pump systems\u003c\/li\u003e\n\u003cli\u003eCooling and ventilation fans\u003c\/li\u003e\n\u003cli\u003eElectric motor assemblies\u003c\/li\u003e\n\u003cli\u003eOEM packaged rotating equipment\u003c\/li\u003e\n\u003cli\u003eAuxiliary vibration monitoring points\u003c\/li\u003e\n\u003cli\u003eSmall to medium rotating machinery skids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-70-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e2-Wire Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4–20 mA vibration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0–5 mils pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e7.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Configuration\u003c\/td\u003e\n\u003ctd\u003e2-wire loop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 C to +100 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing (non-submerged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Size\u003c\/td\u003e\n\u003ctd\u003e9.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Style\u003c\/td\u003e\n\u003ctd\u003eBulkhead mounted enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eConnections \/ Interfaces\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLOOP +\u003c\/td\u003e\n\u003ctd\u003e4–20 mA output \/ power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eSignal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROX OUT\u003c\/td\u003e\n\u003ctd\u003eRaw vibration signal for diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEST\u003c\/td\u003e\n\u003ctd\u003eLoop verification input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eThe transmitter is intended for rigid mounting using bulkhead screw fixation. Installation should ensure stable mechanical coupling between enclosure and mounting surface to avoid resonance-induced signal variation.\u003c\/p\u003e\n\u003cp\u003eProbe cable routing must avoid parallel alignment with high-power conductors to reduce EMI coupling. Shield termination should be implemented at a single grounding point.\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, verify probe gap alignment and confirm stable loop current under normal machine operating conditions before enabling alarm logic in the control system.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function of this transmitter?\u003c\/strong\u003e\u003cbr\u003eIt converts proximity probe vibration into a 4–20 mA signal for monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe system is required?\u003c\/strong\u003e\u003cbr\u003eIt is designed for the Bently Nevada 3300 NSv probe system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the bulkhead mounting provide?\u003c\/strong\u003e\u003cbr\u003eIt allows rigid installation directly onto panels or machine skids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a diagnostic vibration system?\u003c\/strong\u003e\u003cbr\u003eNo, it is intended for trend-level monitoring only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is PROX OUT used for?\u003c\/strong\u003e\u003cbr\u003eIt provides raw vibration signal access for maintenance diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a probe fault occurs?\u003c\/strong\u003e\u003cbr\u003eThe output drops to indicate a NOT OK condition.\u003c\/p\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: 990 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003eFull-scale Option: 05 = 0–5 mils pp\u003c\/li\u003e\n\u003cli\u003eSystem Length Option: 70 = 7.0 meters\u003c\/li\u003e\n\u003cli\u003eMounting Option: 02 = Bulkhead screws\u003c\/li\u003e\n\u003cli\u003eAgency Option: CN variant marking\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308423019,"sku":"990-05-70-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-05-70-02-CN-oaygg0ehdlq_bde42cfa-7566-42f5-8e4a-d0f6bc82e176.jpg?v=1765520754"},{"product_id":"bently-nevada-177230-02-01-cn-seismic-transmitter","title":"Bently Nevada 177230-02-01-CN Seismic Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for continuous machinery vibration monitoring, the \u003cstrong\u003eBently Nevada 177230-02-01-CN\u003c\/strong\u003e is a high-performance \u003cstrong\u003eseismic transmitter\u003c\/strong\u003e designed to measure casing vibration in industrial rotating equipment. This loop-powered, common-axis velocity transmitter provides a standard 4-to-20 mA output proportional to the overall vibration velocity. This output allows direct integration with Programmable Logic Controllers (PLCs), Distributed Control Systems (DCSs), and other process monitoring systems without requiring specialized monitoring monitors.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a robust 316L stainless steel casing and utilizes a 3-pin MIL-C-5015 connector, ensuring reliable performance in harsh, demanding industrial environments. The \u003cstrong\u003e177230-02-01-CN\u003c\/strong\u003e is factory-configured with specific scaling, frequency, and local approval designations to ensure compatibility with regional safety and technical requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Interface:\u003c\/strong\u003e Provides a 4-to-20 mA velocity output for straightforward integration with control systems (PLC\/DCS).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Constructed with a 316L stainless steel housing for superior corrosion resistance and durability in harsh plant environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHermetic Seal:\u003c\/strong\u003e Employs a 3-pin MIL-C-5015 top connector, preventing moisture and dust ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Performance:\u003c\/strong\u003e Factory-configured frequency and range options provide accurate seismic casing measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis seismic transmitter is suitable for a wide variety of industrial rotating machinery, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial fans and blowers\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and reciprocating pumps\u003c\/li\u003e\n  \u003cli\u003eAir and process compressors\u003c\/li\u003e\n  \u003cli\u003eSmall-to-medium steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eElectric motors and gearboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCategory\u003c\/strong\u003e\n      \u003cstrong\u003eSpecification Parameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n      \u003ctd\u003e177230-02-01-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eSeismic Transmitter\u003c\/td\u003e\n      \u003ctd\u003e0 to 50.8 mm\/s (0 to 2.0 in\/s) rms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e10 Hz to 1 kHz (600 to 60 kcps) rms\u003c\/td\u003e\n      \u003ctd\u003eCN (Country-specific approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003e3-pin MIL-C-5015\u003c\/td\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n      \u003ctd\u003e66.0 mm (2.60 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiameter\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.00 in)\u003c\/td\u003e\n      \u003ctd\u003e0.131 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n      \u003ctd\u003e4 to 20 mA DC (loop-powered)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMIL-C-5015 Pin Connection\u003c\/th\u003e\n      \u003cth\u003eSignal Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eLoop Power \/ Positive (+)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eLoop Return \/ Negative (-)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin C\u003c\/td\u003e\n      \u003ctd\u003eNo Connection \/ Shield\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the mounting surface is flat, clean, and free of paint to guarantee accurate transmission of high-frequency vibration signals. Torque the sensor to the manufacturer-specified values using a proper mounting stud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the interface cable through protective conduit where mechanical damage or extreme fluid exposure is likely. Avoid routing adjacent to high-voltage power cables to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the transmitter casing is properly grounded to the machine frame. The cable shield should be grounded at the control system receiver side only to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308750699,"sku":"177230-02-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/177230-02-01-CN-csz2zdtbpdd_4aea254a-bc27-4d32-b126-132b5a2f2640.jpg?v=1765520767"},{"product_id":"990-05-xx-01-cn-mod-165335-01-bently-nevada-990-vibration-transmitter","title":"990-05-XX-01-CN MOD: 165335-01 | Bently Nevada | 990 Vibration Transmitter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/strong\u003e is a loop-powered, two-wire \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business) to provide continuous machinery condition monitoring by interfacing directly with industrial plant networks. This field-mountable device combines the processing electronics of a proximity sensor and a transmitter into a single, compact housing. It accepts high-frequency input signals from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable system, converting raw micro-gap variations into a linear 4 to 20 mA analog current loop. This enables plant operators to route critical radial vibration data straight to standard Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), or simple process data recorders without requiring a separate, rack-based machinery protection system.\u003c\/p\u003e\n\u003cp\u003eThis exact hardware configuration features a factory-calibrated \u003cstrong\u003efull-scale measurement scale of 0-5 mils pp (0-125 um pp)\u003c\/strong\u003e, purposefully optimized for tracking radial shaft vibration amplitudes on rotating machinery. The transmitter body is equipped with standard \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e for rapid, secure snap-on mounting into field marshalling enclosures or local junction boxes. Certified with the \u003cstrong\u003eCN agency approval option\u003c\/strong\u003e, this hardware meets stringent international and regional safety frameworks, including ATEX\/IECEx and Chinese NEPSI hazardous area standards for classified zones. The specialized suffix \u003cstrong\u003eMOD: 165335-01\u003c\/strong\u003e designates a factory-controlled engineering modification that provides precise internal component matching or targeted circuit tuning tailored to optimized machinery metrics while maintaining identical physical dimensions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire, loop-powered configuration that routes a proportional 4 to 20 mA analog signal directly to host DCS or PLC automation cards.\u003c\/li\u003e\n\u003cli\u003eStandardized 0-5 mils peak-to-peak (0-125 um peak-to-peak) linear scale calibration for high-accuracy shaft displacement metrics.\u003c\/li\u003e\n\u003cli\u003eIntegrated heavy-duty 35 mm DIN rail mounting clips for toolless, secure installation on standard terminal enclosure tracks.\u003c\/li\u003e\n\u003cli\u003eDual hazardous zone certifications combining global ATEX\/IECEx standards with local Chinese NEPSI industrial safety markings.\u003c\/li\u003e\n\u003cli\u003eFactory modification code MOD: 165335-01 for specialized circuit optimization and application-specific operational stability.\u003c\/li\u003e\n\u003cli\u003eFront-mounted, isolated BNC dynamic terminal providing raw, unconditioned voltage waveforms for local diagnostic data collectors.\u003c\/li\u003e\n\u003cli\u003eNon-interacting zero and span adjustment pots allowing seamless, independent calibration verification under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandalone radial shaft vibration monitoring on fluid-filmed bearings of industrial centrifugal air compressors and turbo-fans.\u003c\/li\u003e\n\u003cli\u003eDirect asset protection loop integration for medium-sized balance-of-plant electric motors and high-speed centrifugal pumps.\u003c\/li\u003e\n\u003cli\u003eDistributed machinery condition monitoring inside remote oil and gas transport pipeline stations or utility water pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils peak-to-peak (0-125 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length (Matches probe\/cable design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips factory-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCombined ATEX\/IECEx and Chinese NEPSI hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD: 165335-01\u003c\/td\u003e\n\u003ctd\u003eSpecialized factory hardware configuration modification code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils pp (0 to 125 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Loop Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional 4 to 20 mAdc current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to raw probe gap voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit faults)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for standard 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Block Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal strip accepting wire cross-sections up to 1.5 mm squares (16 to 24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure integrated with an aluminum base plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50 kg (3.3 lbm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing atmosphere constraints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE Coaxial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial connection point receiving the incoming transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive current loop connection receiving incoming +12 to +35 Vdc loop power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM) Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative current loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF BNC Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel isolated BNC socket providing unconditioned sensor voltage waves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter backplate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668313272683,"sku":"165335-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/990-05-xx-01-cnmod165335-01-1nopkpz4p4a_225c3749-4676-4cba-b2e5-268285def2e4.jpg?v=1765520925"}],"url":"https:\/\/www.plcprotech.com\/th\/collections\/bently-nevada-vibration-transmitters.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}