{"title":"I\/O Modules","description":"\u003cp\u003eI\/O Modules bridge the gap between physical field devices and the digital control environment of a PLC or DCS. The system architecture consists of isolated input channels for sensors and output channels for actuators, often housed in ruggedized, hot-swappable enclosures. Technical characteristics include optical isolation for circuit protection, varying voltage ranges (AC\/DC), and high-density channel configurations. Functionally, these modules convert analog or discrete electrical signals into data packets for the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/cpus\"\u003eCPU\u003c\/a\u003e to process. By utilizing modular \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/iota-bases\"\u003eIOTA and bases\u003c\/a\u003e, they enable flexible system expansion and simplified field wiring, ensuring precise monitoring and control of industrial machinery and process loops.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Bently Nevada 289837-01 โมดูล I\/O Proximitor\/Seismic 3500 ENCORE","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูล Proximitor\/Seismic I\/O ประสิทธิภาพสูงที่ออกแบบมาเฉพาะสำหรับระบบป้องกันเครื่องจักร Bently Nevada 3500 ENCORE โมดูลนี้ทำหน้าที่เป็นอินเทอร์เฟซด้านหลังที่สำคัญสำหรับเครื่องตรวจจับการสั่นสะเทือน 3500\/42E ช่วยให้เชื่อมต่อกับช่องสัญญาณได้สูงสุดสี่ช่องของเซ็นเซอร์ระยะใกล้หรือเซ็นเซอร์สั่นสะเทือน ถูกใช้อย่างกว้างขวางในภาคพลังงาน น้ำมันและก๊าซ และเหมืองแร่ \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eช่วยให้สามารถตรวจสอบพารามิเตอร์สำคัญของเครื่องจักร เช่น การสั่นสะเทือนรัศมี ตำแหน่งแรงดัน และความเบี้ยว โดยให้การปรับสัญญาณและส่งข้อมูลไปยังโปรเซสเซอร์หลักอย่างเชื่อถือได้ โมดูล I\/O นี้จึงรับประกันการป้องกันเครื่องจักรอย่างต่อเนื่องและการเก็บข้อมูลที่มีความแม่นยำสูง เป็นส่วนประกอบสำคัญสำหรับสถานที่ที่เปลี่ยนจากระบบ 3300 รุ่นเก่าไปยังแพลตฟอร์ม ENCORE ช่วยให้การตรวจสอบการสั่นสะเทือนทันสมัยโดยไม่สูญเสียความสมบูรณ์ของสายไฟภาคสนาม\u003c\/p\u003e\n\u003ch3\u003eการกำหนดค่าทางเทคนิค\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eโมดูล I\/O นี้ถูกออกแบบมาเพื่อรองรับความสามารถสถาปัตยกรรมคู่ของซีรีส์ 3500 ENCORE เพื่อให้มีความยืดหยุ่นสูงสุดสำหรับการตรวจสอบการสั่นสะเทือนและตำแหน่ง\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eความสามารถสี่ช่องสัญญาณ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเมื่อใช้งานในตู้ระบบ 3500 ENCORE มาตรฐาน โมดูลนี้รองรับช่องสัญญาณอิสระสี่ช่อง โดยตั้งโปรแกรมเป็นคู่ (ช่อง 1 \u0026amp; 2; ช่อง 3 \u0026amp; 4) เพื่อทำหน้าที่ตรวจสอบเฉพาะ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eความหลากหลายของเซ็นเซอร์:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเข้ากันได้กับเซ็นเซอร์หลากหลายประเภท รวมถึงโพรบระยะใกล้สำหรับการวัดแบริ่งฟิล์มของเหลว และเซ็นเซอร์สั่นสะเทือน (เครื่องวัดความเร่งหรือเซ็นเซอร์ความเร็ว) สำหรับการสั่นสะเทือนของตัวเครื่อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการรวมระบบ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eในระบบ 3500 ENCORE โมดูล I\/O นี้เชื่อมต่อกับโมดูลรีเลย์ที่ตั้งโปรแกรมได้ เพื่อควบคุมวงจรตัดเครื่องจักรตามจุดตั้งค่าแจ้งเตือนและอันตรายที่ผู้ใช้กำหนด\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eตรรกะการปรับสัญญาณ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eแต่ละช่องสัญญาณจะประมวลผลสัญญาณดิบจากเซ็นเซอร์เป็น \"ค่าคงที่\" เพื่อให้เจ้าหน้าที่ปฏิบัติงานได้รับข้อมูลวินิจฉัยสุขภาพเครื่องจักรแบบเรียลไทม์ ทั้งในสภาวะคงที่และชั่วคราว\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eคุณลักษณะ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eสเปค\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor\/Seismic I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรองรับช่องสัญญาณ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ช่อง (โหมดระบบ) \/ 2 ช่อง (อัปเกรดตู้)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิใช้งาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 ถึง +65 องศาเซลเซียส\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิจัดเก็บ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 ถึง +85 องศาเซลเซียส\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความชื้น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 เปอร์เซ็นต์ ไม่ควบแน่น\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.68 กก.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eขนาด\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208.28 มม. x 48.26 มม. x 127 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eคำถามที่พบบ่อยเกี่ยวกับการใช้งานในอุตสาหกรรม\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้ 289837-01 เป็นอะไหล่แทนโมดูล I\/O ซีรีส์ 3300 ได้โดยตรงหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ได้ ในขณะที่ระบบ 3500 ENCORE ถูกออกแบบมาเพื่ออัปเกรดเครื่องตรวจจับ 3300 แต่ \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eถูกออกแบบมาเฉพาะสำหรับใช้งานในตู้ระบบ 3500 ENCORE สำหรับการตั้งค่า \"อัปเกรดตู้\" ที่ยังใช้โครง 3300 ระบบจะใช้โมดูล I\/O ซีรีส์ 3300 ที่มีอยู่เดิม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูล I\/O นี้รองรับการตรวจจับการสั่นสะเทือนรัศมีและตำแหน่งแรงดันพร้อมกันได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eได้ เนื่องจากช่องสัญญาณถูกตั้งโปรแกรมเป็นคู่ คุณสามารถตั้งค่าช่อง 1 และ 2 สำหรับการสั่นสะเทือนรัศมี ขณะที่ช่อง 3 และ 4 ตั้งค่าสำหรับตำแหน่งแรงดัน (หรือฟังก์ชันอื่นที่รองรับ) ภายในเครื่องตรวจจับ 3500\/42E เดียวกัน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลจัดการกับข้อผิดพลาดของสัญญาณ เช่น เซ็นเซอร์หลุดอย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเครื่องตรวจจับ 3500\/42E ที่เชื่อมต่อผ่าน \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e จะทำการทดสอบตัวเองอย่างต่อเนื่อง หากสัญญาณเซ็นเซอร์ล้มเหลวหรือสายไฟภาคสนามเสียหาย เครื่องตรวจจับจะแจ้งสถานะ \"ไม่ปกติ\" เพื่อป้องกันการตัดเครื่องจักรผิดพลาดและแจ้งเตือนฝ่ายบำรุงรักษาผ่านซอฟต์แวร์กำหนดค่าตู้ 3500\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eคู่มือวิศวกรรมภาคสนามและการติดตั้ง\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการเดินสายและการป้องกันสัญญาณรบกวน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเมื่อเชื่อมต่อเซ็นเซอร์ Proximitor หรือ Seismic กับขั้วต่อของ \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eให้แน่ใจว่าชิลด์สายเคเบิลต่อสายดินเฉพาะที่โมดูล I\/O เท่านั้น หลีกเลี่ยงการต่อสายดินที่ปลายเซ็นเซอร์เพื่อป้องกันวงจรกราวด์ลูป ซึ่งอาจก่อให้เกิดสัญญาณรบกวนและลดความแม่นยำในการวัดการสั่นสะเทือน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการขันยึดติดตั้ง:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eตรวจสอบให้โมดูล I\/O ถูกติดตั้งอย่างเต็มที่ที่ด้านหลังของตู้ ENCORE และขันสกรูยึดให้แน่นเพื่อยึดโมดูลกับแผงหลังอย่างมั่นคง ซึ่งสำคัญต่อการรักษาความสมบูรณ์ของสัญญาณในสภาพแวดล้อมที่มีการสั่นสะเทือนสูง เช่น ชั้นคอมเพรสเซอร์หรือห้องกังหัน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการป้องกันสิ่งแวดล้อม:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eแม้โมดูลจะรองรับความชื้นไม่ควบแน่นสูงสุด 95 เปอร์เซ็นต์ ควรติดตั้งในตู้ที่มีมาตรฐาน NEMA 4 หรือ IP65 หากอยู่ในพื้นที่ที่มีความชื้นสูงหรือสารเคมีกัดกร่อน และควรมีการระบายอากาศภายในตู้เพื่อรักษาอุณหภูมิการใช้งานไม่เกิน 65 องศาเซลเซียส\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการตรวจสอบการตั้งค่า:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eหลังจากเปลี่ยนโมดูล I\/O ให้ใช้ซอฟต์แวร์กำหนดค่าตู้ 3500 ตรวจสอบให้แน่ใจว่าการจับคู่ช่องสัญญาณและประเภทเซ็นเซอร์ตรงกับที่ติดตั้งในภาคสนาม และทำการตรวจสอบวงจรเพื่อให้แน่ใจว่าจุดตั้งค่าแจ้งเตือนและอันตรายควบคุมโมดูลรีเลย์ที่เกี่ยวข้องอย่างถูกต้อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"โมดูล I\/O แบบไม่แยก Bently Nevada 133819-02 3500\/61 RTD\/TC","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e เป็น \u003cspan\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจร\u003c\/span\u003e ที่ออกแบบมาเฉพาะสำหรับ \u003cstrong\u003eเครื่องตรวจวัดอุณหภูมิ 3500\/61\u003c\/strong\u003e โมดูลนี้ให้ส่วนติดต่อทางกายภาพสำหรับการตรวจวัดอุณหภูมิหกช่องทาง รองรับทั้งเซ็นเซอร์ตรวจจับอุณหภูมิแบบต้านทาน (RTD) และเทอร์โมคัปเปิล (TC) \u003cspan\u003e133819-02\u003c\/span\u003e มี \u003cspan\u003eการต่อสายภายใน\u003c\/span\u003e ทำให้สายไฟภาคสนามสามารถเชื่อมต่อโดยตรงกับบล็อกเทอร์มินัลบนโมดูล I\/O ได้ รุ่นนี้ที่ไม่แยกวงจรให้ความยืดหยุ่นสูงสุด โดยอนุญาตให้ผู้ใช้ตั้งค่าโมดูลสำหรับ TC, RTD หรือผสมผสานเซ็นเซอร์ทั้งสองประเภทในหกช่องทางได้\u003c\/p\u003e\n\u003ch3\u003eฟังก์ชันอัจฉริยะและเอาต์พุตเครื่องบันทึก\u003c\/h3\u003e\n\u003cp\u003eในฐานะส่วนประกอบของซีรีส์ \u003cspan\u003e3500\/61\u003c\/span\u003e โมดูล I\/O นี้มี \u003cspan\u003eเอาต์พุตเครื่องบันทึก\u003c\/span\u003e เฉพาะสำหรับแต่ละช่องทางทั้งหกช่อง โดยให้สัญญาณ \u003cspan\u003e+4 ถึง +20 mA\u003c\/span\u003e ที่สัดส่วนกับช่วงเต็มของเครื่องตรวจวัด ช่วยให้สามารถเชื่อมต่อกับระบบควบคุมภายนอก, DCS หรือเครื่องบันทึกกราฟสำหรับการบันทึกข้อมูลได้อย่างราบรื่น สถาปัตยกรรมของโมดูลนี้ทนต่อความผิดพลาด; การทำงานของเครื่องตรวจวัดจะไม่ถูกกระทบจากการลัดวงจรที่เอาต์พุตเครื่องบันทึก เพื่อให้ฟังก์ชันป้องกันเครื่องจักรหลักยังคงทำงานอยู่\u003c\/p\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eคุณลักษณะ\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eรายละเอียดสเปค\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eหมายเลขชิ้นส่วน\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eความเข้ากันได้กับเครื่องตรวจวัด\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eช่องทางอินพุต\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 ช่อง (ตั้งโปรแกรมแยกสำหรับ RTD หรือ TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eประเภทการต่อสาย\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการต่อสายภายใน (บนโมดูล)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eการแยกวงจร\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eไม่แยกวงจร\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eแหล่งจ่ายกระแส RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA ที่ 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eเอาต์พุตเครื่องบันทึก\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 ถึง +20 mA (โหลด: 0 ถึง 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eความแม่นยำ (ภายใน)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C ที่ 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5.4 °F ที่ 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eอุณหภูมิการทำงาน\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C ถึง +65 °C (-22 °F ถึง +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eน้ำหนัก\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 กก. (1.0 ปอนด์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eขนาด (สูงxกว้างxลึก)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 มม. x 24.4 มม. x 99.1 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eคำถามที่พบบ่อยทางเทคนิค\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eความแตกต่างหลักระหว่างโมดูล 3500\/60 และ 3500\/61 คืออะไร?\u003c\/span\u003e โมดูลทั้งสองให้ฟังก์ชันการตรวจวัดอุณหภูมิหกช่องทางเหมือนกัน แต่ \u003cspan\u003e3500\/61\u003c\/span\u003e (ซึ่งใช้ I\/O \u003cspan\u003e133819-02\u003c\/span\u003e) มีเอาต์พุตเครื่องบันทึก 4-20 mA สำหรับแต่ละช่อง ในขณะที่ 3500\/60 ไม่มีเอาต์พุตแอนะล็อกเหล่านี้\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eฉันสามารถผสมเซ็นเซอร์ประเภทต่าง ๆ บนโมดูล 133819-02 เดียวได้หรือไม่?\u003c\/span\u003e ได้ โมดูล I\/O แบบไม่แยกวงจรนี้สามารถตั้งค่าผ่าน \u003cspan\u003eซอฟต์แวร์กำหนดค่า 3500 Rack\u003c\/span\u003e ให้รับอินพุต TC และ RTD ผสมกันได้ในหกช่องทาง\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eโมดูลจัดการการเดินสาย RTD อย่างไร?\u003c\/span\u003e โมดูลมีแหล่งจ่ายกระแสพิเศษที่ \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e ออกแบบมาเพื่อรองรับ RTD แบบ 3 สาย (ใช้แหล่งจ่ายสองตัวเพื่อชดเชยสายไฟนำ) และ RTD แบบ 4 สาย (ใช้แหล่งจ่ายเดียว) เพื่อให้การวัดอุณหภูมิมีความแม่นยำสำหรับเซ็นเซอร์ประเภทต่าง ๆ\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eคู่มือวิศวกรรมภาคสนามและการติดตั้ง\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eการจัดการการต่อสายภายใน:\u003c\/span\u003e \u003cspan\u003e133819-02\u003c\/span\u003e ใช้บล็อกเทอร์มินัลภายใน โปรดตรวจสอบว่าสายไฟภาคสนามติดป้ายกำกับอย่างถูกต้องและยึดแน่นเพื่อป้องกันสัญญาณขาดตอน ซึ่งอาจทำให้ไฟ LED สถานะ \"Bypass\" หรือ \"Error\" บนแผงหน้าปัดของเครื่องตรวจวัดติดสว่าง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eข้อควรพิจารณาด้านสิ่งแวดล้อม:\u003c\/span\u003e โมดูลนี้รองรับอุณหภูมิการทำงานตั้งแต่ \u003cspan\u003e-30 °C ถึง +65 °C\u003c\/span\u003e สำหรับการติดตั้งในสภาพแวดล้อมที่รุนแรง โปรดตรวจสอบว่าแร็ค 3500 มีการระบายอากาศเพียงพอเพื่อรักษาขอบเขตอุณหภูมินี้และป้องกันการเปลี่ยนแปลงความแม่นยำ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eการกำหนดค่า TMR:\u003c\/span\u003e เมื่อใช้ในแอปพลิเคชัน Triple Modular Redundant (TMR) ต้องติดตั้งเครื่องตรวจวัดอุณหภูมิสามเครื่องในกลุ่มที่อยู่ติดกัน ระบบใช้การโหวตสองประเภทเพื่อป้องกันความล้มเหลวจุดเดียวที่อาจทำให้เกิดการตัดการทำงานผิดพลาดในเครื่องจักรที่สำคัญ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อได้เปรียบทางวิศวกรรม\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e เป็นโซลูชันที่คุ้มค่าและมีความหนาแน่นสูงสำหรับการป้องกันอุณหภูมิของเครื่องจักร โดยรวมการรองรับ TC และ RTD ไว้ในโมดูลเดียวที่มีการต่อสายภายใน ช่วยลดพื้นที่ตู้และลดความซับซ้อนของการเดินสาย สำหรับการจัดซื้อแบบ B2B การเลือก \u003cspan\u003e133819-02\u003c\/span\u003e ของแท้จะรับประกันความเข้ากันได้เต็มที่กับ \u003cspan\u003eระบบตรวจวัด 3500\u003c\/span\u003e รักษาความแม่นยำสูงและความทนทานที่จำเป็นสำหรับการปกป้องเทอร์ไบน์, คอมเพรสเซอร์ และมอเตอร์อุตสาหกรรมขนาดใหญ่\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"bently-nevada-133442-01-3500-50m-i-o-module-with-internal-terminations","title":"Bently Nevada 133442-01 3500\/50M I\/O Module with Internal Terminations","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel Tachometer Input\/Output (I\/O) module designed for the 3500 Series Machinery Protection System. This module serves as the primary physical interface for field wiring, specifically engineered to operate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTachometer Main Modules. It processes high-frequency pulse inputs from proximity probes or passive magnetic pickups to facilitate precise measurements of rotational speed, rotor acceleration, and reverse rotation.\u003c\/p\u003e\n\u003cp\u003eAs an internal termination variant, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated screw terminal blocks directly on the module body, optimizing it for high-density cabinet installations where space is a priority. This hardware configuration is widely deployed in power generation, petrochemical, and gas compression facilities for continuous machinery monitoring and critical overspeed protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTachometer I\/O Module with Internal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-channel differential or single-ended pulse inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity probe systems, Magnetic pickups\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+10.0 Vdc to -24.0 Vdc (internally limited)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.15 kΩ (Internal Barrier variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring spare parts, ensure the part number matches the specific rack configuration to avoid hardware\/software mismatch errors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e: 3500\/50M Tachometer I\/O Module with Internal Terminations (Internal Barrier Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Main Module\u003c\/strong\u003e: 3500\/50-01-XX or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M-01-XX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Fixed screw terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003ch3\u003eWiring and Shielding Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection\u003c\/strong\u003e: Use twisted, shielded pair cabling (18 AWG to 22 AWG) for all transducer connections to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect shields to the designated instrument ground terminal on the 3500 rack chassis at one end only. Do not ground at the field transducer to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Maintain a minimum distance of 300 mm (12 inches) between speed sensor cables and high-voltage AC power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Hot-Swap Precautions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Alignment\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in the rear slot corresponding to the front-mounted 3500\/50M main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBypass Protocol\u003c\/strong\u003e: Prior to module extraction or insertion, bypass all associated machinery trip relays to prevent accidental turbine or compressor trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Tighten terminal block screws to a maximum of 0.56 N·m (5 in·lb) to protect the internal PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 133442-01 compatible with older 3500\/50 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is fully backwards compatible with standard 3500\/50 and upgraded 3500\/50M modules, provided the rack configuration software matches the hardware variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the External Termination (ET) version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures built-in terminal blocks. The ET version requires a multi-pin cable to connect to a remote DIN-rail terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the risks of exceeding the input signal range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile internal clipping circuits limit voltages, sustained overvoltage outside the +10V to -24V range can degrade the internal barrier circuitry and cause channel faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519650667,"sku":"133442-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133442-01-i-o-module-with-internal-terminations-1a4iq1cd4r4_bc83d92f-d0df-4c88-95ae-2fed0e219041.jpg?v=1765440137"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a specialized \u003cstrong\u003eRTD\/TC I\/O Module with Internal Barriers and Internal Terminations\u003c\/strong\u003e developed for the \u003cstrong\u003e3500\/61 16-Channel Temperature Monitor\u003c\/strong\u003e within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.\u003c\/p\u003e\n\u003cp\u003eField programming and configuration of channel types are handled through the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the \u003cstrong\u003e3500\/61\u003c\/strong\u003e subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses physical internal termination blocks paired with integrated safety barriers for hazardous field environments.\u003c\/li\u003e\n\u003cli\u003eNon-isolated universal channel paths support individual configuration for TCs, 3-wire RTDs, or 4-wire RTDs.\u003c\/li\u003e\n\u003cli\u003eEliminates the need for manual component calibration through full integration with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes dedicated high-precision current source networks to satisfy multi-lead RTD measuring circuits.\u003c\/li\u003e\n\u003cli\u003eStructural design optimizes rack footprint by consolidating external terminal boxes and separate intrinsic safety hardware into one rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel motor and generator stator winding thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust gas temperature (EGT) profile tracking and distribution mapping.\u003c\/li\u003e\n\u003cli\u003eIndustrial bearing temperature monitoring on high-speed pumps, fans, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant auxiliary machinery protection across chemical and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: RTD\/TC I\/O Module with Internal Barriers and Internal Terminations (Non-Isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Subtype\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer \u0026amp; Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple (TC) Capability\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Temperature Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType E: -100 degC to +1000 degC (-148 degF to +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType J: -18 degC to +760 degC (+0 degF to +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType K: -18 degC to +1370 degC (+0 degF to +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType T: -160 degC to +400 degC (-256 degF to +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Temperature Detector (RTD)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges with External Barriers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF (except for 10 Ohm Copper RTDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Isolated External Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-1 degC at 25 degC (+\/-1.8 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated Internal Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-2 degC at 25 degC (+\/-3.6 degF at 77 degF) \/ +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNo field calibration required; specified at +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position Requirements\u003c\/td\u003e\n\u003ctd\u003eConsumes 1 full-height rear slot directly behind the main monitor processor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Barrier Screw Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect physical land connection for raw multi-wire RTD leads and TC field extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Bus Plug\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Install the \u003cstrong\u003e136711-02\u003c\/strong\u003e module directly from the rear side of the 3500 monitoring chassis. It must align perfectly into the slot corresponding to the front-mounted 3500\/61 main processor card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Matching:\u003c\/strong\u003e Verify through configuration utility software that each channel configuration (thermocouple versus 3-wire or 4-wire RTD) exactly matches the field wire layout connected to the terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Wire Uniformity:\u003c\/strong\u003e For all 3-wire and 4-wire RTD configurations, employ copper lead wires of uniform gauge and length to guarantee precise lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Control:\u003c\/strong\u003e Run all external field sensor lines through twisted, shielded wire pairs. Land the shields at the designated instrumentation ground terminal provided on the module frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement:\u003c\/strong\u003e Ensure the cabinet installation maintains clean, unobstructed ventilation paths so that the active operating ambient temperature around the internal barrier housing does not exceed 65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 136711-02 component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500\/61 monitor slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation non-isolated mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouples and RTDs on the same I\/O card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific type of RTD is recommended for standard engineering installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual field calibration required after replacing this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat constant current value is provided for RTD sensors by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated current source network delivers 925 +\/- 15 uA at an environmental reference of 25 degC per transducer pathway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many internal current supplies are engaged when a 4-wire RTD is connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the defined operating temperature limitation for this module version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of this rear-mount component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain the primary digital processor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the rear-insert I\/O termination assembly with built-in barriers; the front processor module is supplied separately.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"โมดูลอินพุต\/เอาต์พุต Keyphasor 3500\/25 รุ่น Bently Nevada 135473-01 (มีแผงกั้นภายใน)","description":"\u003ch3\u003eภาพรวมสินค้า\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูล I\/O ขนาดครึ่งความสูงที่ออกแบบมาเฉพาะสำหรับระบบ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor การกำหนดค่านี้รวม\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eอุปสรรคภายใน\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eและ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eการสิ้นสุดภายใน\u003c\/strong\u003eไว้ด้วยกัน เพื่อให้เป็นอินเทอร์เฟซความปลอดภัยภายในฮาร์ดแวร์สำหรับทรานสดิวเซอร์ที่ตั้งอยู่ในพื้นที่อันตราย โมดูลนี้ถูกออกแบบมาเพื่อรับและประมวลผลสัญญาณพัลส์หนึ่งครั้งต่อรอบหรือหลายครั้งต่อรอบจากโพรบใกล้เคียงหรือการรับสัญญาณแม่เหล็ก ซึ่งจำเป็นสำหรับการคำนวณความเร็วรอบเครื่องจักรและให้ข้อมูลอ้างอิงเฟสสำหรับการวิเคราะห์การสั่นสะเทือน\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eทำหน้าที่เป็นอินเทอร์เฟซทางกายภาพภายในแร็ค 3500 เพื่อให้แน่ใจว่ามีการแยกไฟฟ้าและการปรับสัญญาณสำหรับการปกป้องเครื่องจักรที่สำคัญ แม้ว่าโมดูลจะรองรับการวัดเฟส แต่ได้รับการปรับแต่งสำหรับการตรวจสอบความเร็วเพลาที่มีความแม่นยำสูง เมื่อใช้เวอร์ชันอุปสรรคภายใน โมดูลจะให้จุดเชื่อมต่อที่ปลอดภัยซึ่งจำกัดพลังงานไฟฟ้าที่ส่งไปยังเซ็นเซอร์ภาคสนาม เพื่อให้เป็นไปตามมาตรฐานความปลอดภัยในอุตสาหกรรมที่เข้มงวดสำหรับบรรยากาศที่ระเบิดได้\u003c\/p\u003e\n\u003ch3\u003eการกำหนดค่าทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eคุณลักษณะ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเภทสินค้า\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eโมดูล Keyphasor I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eซีรีส์ 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเภทการสิ้นสุด\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการสิ้นสุดภายใน\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอินเทอร์เฟซความปลอดภัย\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eอุปสรรคภายใน (ชนิด Zener)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eช่องสัญญาณอินพุต\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสัญญาณทรานสดิวเซอร์ 2 ช่อง (Proximity หรือ Magnetic Pickup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการใช้พลังงานทั่วไป 3.2 วัตต์\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความต้านทานอินพุต\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eความต้านทานอินพุตขั้นต่ำ 21.8 กิโลโอห์ม\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eช่วงสัญญาณ (ไม่แยกส่วน)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0.8 V ถึง -21.0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความเร็วขั้นต่ำของการรับสัญญาณแม่เหล็ก\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 200 รอบต่อนาที (3.3 เฮิรตซ์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 มม. x 24.4 มม. x 103.1 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 กก. (1.01 ปอนด์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 องศาเซลเซียส ถึง +65 องศาเซลเซียส (32 องศาฟาเรนไฮต์ ถึง +150 องศาฟาเรนไฮต์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความชื้น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eความชื้นไม่ควบแน่น 95%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cp\u003eการจัดซื้อในอุตสาหกรรมควรมุ่งเน้นที่หมายเลขชิ้นส่วนเฉพาะเพื่อให้แน่ใจว่าเข้ากันได้กับการกำหนดค่าตัวตรวจสอบ 3500\/25\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eคำอธิบาย\u003c\/strong\u003e: โมดูล Keyphasor I\/O พร้อมอุปสรรคภายในและการสิ้นสุดภายใน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eสภาพสินค้า\u003c\/strong\u003e: ของใหม่แท้\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eสถานะสินค้า\u003c\/strong\u003e: สต็อกอะไหล่\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้สามารถให้การแยกส่วนสำหรับแอปพลิเคชัน Proximitor ได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ สามารถใช้งานร่วมกับแอปพลิเคชัน Proximitor ได้ แต่ต้องใช้แหล่งจ่ายไฟภายนอกเพื่อให้เกิดการแยกส่วน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eวัตถุประสงค์หลักของการออกแบบเวอร์ชัน I\/O แบบแยกส่วนคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eถูกสร้างขึ้นโดยเฉพาะสำหรับแอปพลิเคชันการรับสัญญาณแม่เหล็กที่สัญญาณถูกเชื่อมต่อแบบขนานกับอุปกรณ์หลายตัว เช่น ระบบควบคุม\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นถ้าสัญญาณอินพุตเกินช่วงที่กำหนด?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eสัญญาณที่เกินช่วงแรงดันที่กำหนดจะถูกจำกัดภายในโดยวงจรของโมดูล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eเอกสารอ้างอิงทางเทคนิค: การเดินสายไฟ, จัมเปอร์ และข้อกำหนด\u003c\/h3\u003e\n\u003ch3\u003e1. การเดินสายช่องสัญญาณ \u0026amp; คำนิยามพิน\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูล I\/O การสิ้นสุดภายในที่มี Galvanic Barriers ในตัว มีแถบเทอร์มินัลอิสระสองแถบสำหรับช่อง 1 และช่อง 2\u003c\/p\u003e\n\u003ch4\u003eA. การเดินสาย Proximity Probe (3-Wire)\u003c\/h4\u003e\n\u003cp\u003eสำหรับเซ็นเซอร์กระแส Eddy มาตรฐาน (เช่น ซีรีส์ 3300 XL):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eจ่ายไฟสำหรับ Proximitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eสัญญาณร่วม\/กลับ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eอินพุตสำหรับสัญญาณแรงดันพัลส์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. การเดินสาย Magnetic Pickup (แบบ Passive 2-Wire)\u003c\/h4\u003e\n\u003cp\u003eสำหรับเซ็นเซอร์ความเร็วแม่เหล็กไฟฟ้าสร้างตัวเอง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเชื่อมต่อกับขั้วบวก (+) ของเซ็นเซอร์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเชื่อมต่อกับขั้วลบ (-) ของเซ็นเซอร์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eต้องไม่เชื่อมต่อ (ลอย)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. การป้องกันและการต่อสายดิน IS\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Shield):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเชื่อมต่อสายชีลด์ของสายฟิลด์กับเทอร์มินัลเฉพาะนี้\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS Earth :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eโมดูลนี้ต้องต่อสายดินผ่าน\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Barrier Earth Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eไปยังบัสสายดิน Intrinsic Safety เฉพาะเพื่อความปลอดภัยป้องกันการระเบิด\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. การกำหนดค่าจัมเปอร์ฮาร์ดแวร์\u003c\/h3\u003e\n\u003cp\u003eจัมเปอร์ตั้งอยู่บนแผงวงจรภายในและต้องตั้งค่าก่อนการติดตั้ง\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภททรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eจัมเปอร์จ่ายไฟทรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eจัมเปอร์การเชื่อมต่ออินพุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eฟังก์ชันตรรกะ\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eโพรบตรวจจับใกล้\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (ภายใน)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (กระแสตรง)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eจ่ายไฟ; อนุญาตให้มีไบแอส DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการรับแม่เหล็ก\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (ภายนอก\/ปิด)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (กระแสสลับ)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eตัดไฟ; กรองสัญญาณรบกวน DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eสำคัญ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eปิดเครื่อง 3500 rack หรือถอดโมดูลมอนิเตอร์ก่อนปรับจัมเปอร์เพื่อหลีกเลี่ยงการเกิดประกายไฟฟ้า\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. ข้อกำหนดประสิทธิภาพหลัก\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eความจุช่องสัญญาณ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 ช่องสัญญาณอินพุตอิสระ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eช่วงความถี่:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 ถึง 1,200,000 cpm (\u003cstrong\u003e0.017 Hz ถึง 20 kHz\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eช่วงแรงดันไฟฟ้าอินพุต:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V ถึง -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(เฉพาะสำหรับ Barrier I\/O)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโหมดการปรับสภาพ:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเกณฑ์อัตโนมัติ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eสัญญาณขั้นต่ำ 2 V peak-to-peak; ความเร็วขั้นต่ำ 120 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเกณฑ์ด้วยตนเอง:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eปรับได้ตั้งแต่ 0 ถึง -20 Vdc; สัญญาณขั้นต่ำ 500 mV; รองรับความเร็วต่ำสุดถึง 1 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eสิ่งแวดล้อม:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eการใช้พลังงาน:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.2 วัตต์\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(โดยทั่วไป)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิการทำงาน:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 องศาเซลเซียส ถึง 65 องศาเซลเซียส\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. ใบรับรองพื้นที่อันตราย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาสำหรับสภาพแวดล้อมที่มีความเสี่ยงสูง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eอเมริกาเหนือ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Div 2, Groups A, B, C, D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eยุโรป (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (อินพุตที่ได้รับการจัดอันดับสำหรับโซน 0)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. การสนับสนุนการกำหนดค่าระบบ\u003c\/h3\u003e\n\u003cp\u003eหลังการติดตั้งทางกายภาพ ให้ใช้\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eซอฟต์แวร์กำหนดค่าแร็ค 3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเพื่อตรวจสอบ:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการตั้งค่า Hysteresis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเพื่อป้องกันการทริกเกอร์ผิดพลาดจากสัญญาณที่มีเสียงรบกวน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eทิศทาง:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eตั้งทิศทางพัลส์ (บวก\/ลบ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eช่องสัญญาณแอคทีฟ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eตรวจสอบให้ซอฟต์แวร์ตรงกับการตั้งค่า jumper ทางกายภาพ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eส่วนที่ 2: แผนภาพเทอร์มินัล \u0026amp; การกำหนดค่าซอฟต์แวร์\u003c\/h3\u003e\n\u003ch3\u003e1. แผนผังขาเทอร์มินัล (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eใช้ลำดับ 4 เทอร์มินัลเฉพาะสำหรับแต่ละช่อง ด้านล่างเป็นแผนผังการเชื่อมต่อสายภาคสนามของคุณ:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eเทอร์มินัล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eป้ายชื่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Probe (3 สาย)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup (2 สาย)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 Vdc แหล่งจ่ายไฟ (สีขาว)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eไม่มีการเชื่อมต่อ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eกราวด์\/ทั่วไป (สีดำ)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสัญญาณลบ (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสัญญาณเข้า (สีแดง)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสัญญาณบวก (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสายชีลด์\/สายระบาย\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสายชีลด์\/สายระบาย\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. การกำหนดค่าซอฟต์แวร์ (3500 RACK CONFIG)\u003c\/h3\u003e\n\u003cp\u003eเมื่อฮาร์ดแวร์ติดตั้งแล้ว คุณต้องกำหนดค่าต่อไปนี้ในซอฟต์แวร์ยูทิลิตี้:\u003c\/p\u003e\n\u003ch4\u003eA. การตั้งค่าเกณฑ์\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเกณฑ์อัตโนมัติ\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eระบบจะคำนวณจุดทริกเกอร์โดยอัตโนมัติที่ 50% ของความกว้างสัญญาณ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเหมาะสำหรับ\u003c\/strong\u003e: ความเร็วการทำงานมาตรฐาน (\u0026gt;120 รอบต่อนาที) ที่มีพัลส์สะอาดและสม่ำเสมอ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเกณฑ์ด้วยตนเอง\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eคุณตั้งค่าแรงดันไฟฟ้าคงที่ด้วยตนเอง (เช่น -8.0 Vdc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเหมาะสำหรับ\u003c\/strong\u003e: การเริ่มต้นความเร็วต่ำหรือสัญญาณที่มี \"กลิทช์\" หรือเสียงรบกวนมาก\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eเคล็ดลับการคำนวณ\u003c\/strong\u003e: ตั้งค่าเกณฑ์ที่จุดกึ่งกลางระหว่างจุดสูงสุดของพัลส์และสัญญาณฐาน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Hysteresis (ลดเสียงรบกวน)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eสำหรับ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMagnetic Pickups\u003c\/strong\u003e คุณควรกำหนดค่าค่า Hysteresis (โดยทั่วไป\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.2V ถึง 0.5V\u003c\/strong\u003e) เพื่อป้องกันการทริกเกอร์ซ้ำหากสัญญาณมีเสียงรบกวนขณะข้ามเกณฑ์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. ขอบแอคทีฟ (ทิศทาง)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eขอบลบ\u003c\/strong\u003e: ทริกเกอร์เมื่อสัญญาณเปลี่ยนจาก 0V ไปยัง -24V (มาตรฐานสำหรับโพรบ Bently ส่วนใหญ่)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eขอบบวก\u003c\/strong\u003e: ทริกเกอร์เมื่อสัญญาณเคลื่อนที่ในทิศทางบวก\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. รายการตรวจสอบการติดตั้งที่สำคัญ\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eกราวด์บาเรียร์\u003c\/strong\u003e: ตรวจสอบให้แน่ใจว่าโมดูล\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eติดตั้งอยู่ในแร็ค หากไม่มีโมดูลนี้ 135473-01 จะไม่สามารถกราวด์บาเรียร์ความปลอดภัยภายในได้อย่างถูกต้อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการตรวจสอบ Jumper\u003c\/strong\u003e: ตรวจสอบให้แน่ใจว่า\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eและ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eของ jumper ตรงกับเซ็นเซอร์ที่เกี่ยวข้อง ข้อผิดพลาดทั่วไปคือการปล่อย jumper PWR ไว้ที่\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเมื่อใช้ Magnetic Pickup ซึ่งอาจทำให้เกิดเสียงรบกวนหรือความร้อน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการเข้ารหัส\u003c\/strong\u003e: ใช้\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eองศาเซลเซียส\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eและ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eเซลเซียส\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eในเอกสารทางเทคนิคของคุณเพื่อหลีกเลี่ยงปัญหาตัวอักษรเสียหายที่เคยเกิดขึ้นใน CMS ของคุณ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-81546-01-xdcr-i-o-and-record-terminals","title":"เทอร์มินัลอินพุต\/เอาต์พุตและบันทึก Bently Nevada 81546-01 XDCR","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e81546-01\u003c\/strong\u003e เป็นโมดูล \u003cstrong\u003eขั้วต่ออินพุต\/เอาต์พุตทรานสดิวเซอร์และขั้วบันทึก\u003c\/strong\u003e เกรดอุตสาหกรรมที่มีความน่าเชื่อถือสูง ออกแบบมาเพื่อการรวมอย่างราบรื่นภายในระบบตรวจสอบสภาพเครื่องจักรหมุน อุปกรณ์ต่อสายฮาร์ดแวร์เฉพาะนี้สร้างการเชื่อมต่อเส้นทางสัญญาณที่สำคัญระหว่างทรานสดิวเซอร์สนามที่ติดตั้งบนตัวเรือนกับเครื่องมือตรวจสอบป้องกันทรัพย์สินส่วนกลางหรืออุปกรณ์บันทึกข้อมูลภายนอก \u003cstrong\u003e81546-01\u003c\/strong\u003e ให้การจัดเส้นทางบล็อกขั้วต่อที่มีโครงสร้างสำหรับสัญญาณโพรบตรวจจับระยะใกล้ดิบ เซ็นเซอร์ความเร็ว หรือเครื่องวัดความเร่ง พร้อมทั้งจัดหาเส้นทางขั้วบันทึกอิสระในเวลาเดียวกัน  \u003c\/p\u003e\n\u003cp\u003eโดยช่วยให้การต่อสายเป็นระเบียบและปลอดภัย ปกป้องรูปคลื่นวินิจฉัยแรงดันต่ำที่บอบบางจากการเสื่อมสภาพและการรบกวนจากความจุไฟฟ้า ออกแบบมาให้ทำงานได้อย่างน่าเชื่อถือภายในตู้แผงที่มีสภาพแวดล้อมรุนแรง บล็อกนี้มีช่องทางแยกกายภาพที่ชัดเจนเพื่อแยกเอาต์พุตการตรวจสอบหลักออกจากสายเครื่องมือบันทึกรอง   \u003cstrong\u003e-01\u003c\/strong\u003e การกำหนดตัวเลือกระบุรูปแบบฮาร์ดแวร์มาตรฐานพื้นฐาน เพื่อให้แน่ใจว่ามีการจัดวางคงที่ การกำหนดพินมาตรฐาน และความเข้ากันได้ในการติดตั้งเชิงกลกับแร็คป้องกันโรงงานเฉพาะทาง  \u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eสถาปัตยกรรมการต่อสายแบบสองวัตถุประสงค์ที่รวมเส้นทางอินพุต\/เอาต์พุตทรานสดิวเซอร์หลักกับเส้นทางขั้วบันทึกอิสระ  \u003c\/li\u003e\n\u003cli\u003eบล็อกต่อสายแบบหนีบสกรูหรือสปริงที่ให้การเชื่อมต่อสายที่ทนต่อการสั่นสะเทือนสำหรับสายสนาม  \u003c\/li\u003e\n\u003cli\u003eช่องทางแยกกายภาพของฮาร์ดแวร์ที่ชัดเจนเพื่อป้องกันการรบกวนสัญญาณและการรบกวนระหว่างช่องสัญญาณ  \u003c\/li\u003e\n\u003cli\u003eโปรไฟล์การรวมแผงที่เรียบง่ายเพื่อเพิ่มประสิทธิภาพการใช้พื้นที่ภายในตู้จัดสายท้องถิ่น  \u003c\/li\u003e\n\u003cli\u003eโครงสร้างกายภาพที่ทนทานสำหรับการใช้งานต่อเนื่องบนสกิดสมดุลของโรงงานที่มีการสั่นสะเทือนสูง  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการต่อสายสนามความหนาแน่นสูงสำหรับโพรบตรวจจับระยะใกล้และเซ็นเซอร์ตัวเรือนที่ติดตามเครื่องจักรหมุนที่สำคัญ  \u003c\/li\u003e\n\u003cli\u003eการเดินสายสัญญาณวินิจฉัยที่สะอาดจากแร็คป้องกันเครื่องจักรไปยังเครื่องบันทึกแบบไม่ใช้กระดาษต่อเนื่องหรืออินพุตของระบบบันทึกประวัติของโรงงาน  \u003c\/li\u003e\n\u003cli\u003eการจัดการเครื่องมือวัดแบบมีโครงสร้างภายในตู้ป้องกันทรัพย์สินส่วนกลางและโซนเขตพื้นที่อันตราย  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียด\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อมูลอ้างอิงการสั่งซื้อสินค้า  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสรุ่นพื้นฐาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546 (ขั้วต่ออินพุต\/เอาต์พุตทรานสดิวเซอร์และขั้วบันทึก)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสประกอบเต็มรูปแบบ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eบล็อกต่อท้ายตัวเลือกเต็มรูปแบบ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (การกำหนดค่าและตัวเลือกฐานติดตั้งมาตรฐาน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลอินพุต\/เอาต์พุตและต่อสายบันทึกทรานสดิวเซอร์ (XDCR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทการเชื่อมต่อสายไฟ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eบล็อกขั้วสกรูอุตสาหกรรมหรือแถบหนีบแบบหนีบ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโปรไฟล์ความเข้ากันได้ของสัญญาณ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eรูปคลื่นการสั่นสะเทือนแบบไดนามิกแรงดันต่ำ ตำแหน่ง และความเร็ว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eระดับการแยก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการแยกทางกายภาพระหว่างช่องและการป้องกันเส้นวงจร\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eจำนวนเส้นทางบันทึก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eกำหนดค่าสำหรับการส่งออกบันทึกข้อมูลรองอิสระ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการกำหนดค่าการติดตั้ง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01 ขนาดฐาน\/รอยเท้าโครงเครื่องเฉพาะ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโปรไฟล์วัสดุโครงเครื่อง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eแผ่นหลังโพลิเมอร์กันไฟหรือแก้วอีพ็อกซี่เสริมแรงสำหรับอุตสาหกรรม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการเพิ่มประสิทธิภาพเส้นทางฮาร์ดแวร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการออกแบบโปรไฟล์ต่ำสำหรับแผงมาร์แชลลิ่งโครงสร้าง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขอบเขตอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eซองประสิทธิภาพมาตรฐานอุตสาหกรรมที่ได้รับการจัดอันดับสำหรับสเกลความร้อนในตู้ปิด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการอ้างอิงน้ำหนักปฏิบัติการ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักบล็อกต่อสายภาคสนามมาตรฐานอุตสาหกรรม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eกลุ่มขั้วต่อ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eการกำหนดฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอินพุตทรานสดิวเซอร์ (XDCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดต่อสายสำหรับสายเซ็นเซอร์ภาคสนามดิบ (ไฟฟ้า, สัญญาณ, คอม)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเส้นทาง I\/O ของมอนิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสายส่งออกเฉพาะที่เชื่อมต่อโดยตรงกับแร็คป้องกันหลัก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขั้วบันทึก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อเอาต์พุตแบบขนานแยกสำหรับเครื่องบันทึกและล็อกเกอร์วินิจฉัยภายนอก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eชิลด์\/กราวด์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดกราวด์เฟรมทั่วไปสำหรับต่อสายดรนของสายเคเบิลที่เข้ามา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งแผงมาร์แชลลิ่ง:\u003c\/strong\u003e ยึดโครงบล็อกต่อสายให้แน่นกับแร็คภายในหรือแผ่นหลังที่กำหนด ตรวจสอบให้แน่ใจว่าสกรูทุกตัวถูกขันแน่นเพื่อทนต่อการสั่นสะเทือนของโครงสร้างท้องถิ่น\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการต่อสายทรานสดิวเซอร์:\u003c\/strong\u003e ลอกสายเซ็นเซอร์ที่เข้ามาตามมาตรฐานวิศวกรรมและต่อสายภายในขั้ว XDCR ยึดสกรูให้แน่นเพื่อให้การสัมผัสทางไฟฟ้าต่อเนื่องโดยไม่บีบฉนวนสายไฟ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการแยกสายสัญญาณ:\u003c\/strong\u003e เดินสายบันทึกข้อมูลรองให้ห่างจากสายมอเตอร์ไฟฟ้าแรงสูงหรือรีเลย์สวิตชิ่งหนักภายในแผงเพื่อกำจัดสัญญาณรบกวนแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการต่อสายดรนไวร์:\u003c\/strong\u003e เชื่อมต่อสายดรนของสายเคเบิลเครื่องมือที่เข้ามาอย่างเคร่งครัดกับจุดต่อสายดรนที่กำหนดไว้เพื่อสร้างกราวด์แผงแบบจุดเดียวและป้องกันการเกิดวงจรกราวด์ลูป\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847199595,"sku":"81546-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81546-01-xdcr-i-o-and-record-terminals-qleh4l44are_5a17253a-6dc8-4d4a-a55e-6f41284e3088.jpg?v=1765448948"},{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 3500\/61-02-00 133827-02 โมดูลอินพุต\/เอาต์พุตแบบไม่แยกสำหรับตรวจวัดอุณหภูมิ RTD\/TC","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e เป็นโมดูลตรวจสอบอุณหภูมิหกช่องสัญญาณที่ออกแบบมาสำหรับ \u003cstrong\u003eระบบป้องกันเครื่องจักร Bently Nevada 3500\u003c\/strong\u003e โมดูลนี้รับอินพุตอุณหภูมิทั้ง RTD และเทอร์โมคัปเปิล และทำการวัดอุณหภูมิต่อเนื่องพร้อมฟังก์ชันเปรียบเทียบสัญญาณเตือนสำหรับการใช้งานเครื่องจักรหมุนที่สำคัญ\u003c\/p\u003e\n\u003cp\u003eโมดูล \u003cstrong\u003e133827-02\u003c\/strong\u003e RTD\/TC I\/O แบบไม่แยกวงจรใช้การต่อสายภายนอกและรองรับการกำหนดค่าช่องสัญญาณผสม RTD และ TC ผู้ใช้สามารถกำหนดค่าช่องสัญญาณแต่ละช่องผ่านซอฟต์แวร์กำหนดค่าชั้นวาง 3500 สำหรับการใช้งาน RTD หรือเทอร์โมคัปเปิล\u003c\/p\u003e\n\u003cp\u003eโมดูล \u003cstrong\u003e3500\/61\u003c\/strong\u003e ซีรีส์นี้แตกต่างจาก \u003cstrong\u003e3500\/60\u003c\/strong\u003e โดยให้เอาต์พุตเครื่องบันทึกสำหรับแต่ละช่องสัญญาณตรวจสอบ เอาต์พุตเครื่องบันทึกรองรับการส่งสัญญาณ 4 ถึง 20 mA ซึ่งสัดส่วนกับช่วงเต็มที่ตั้งค่าไว้ของมอนิเตอร์\u003c\/p\u003e\n\u003cp\u003eโมดูลรองรับอินพุตทรานสดิวเซอร์ได้สูงสุดหกช่องสัญญาณ และมีจุดตั้งค่าสัญญาณเตือน Alert และ Danger ที่ตั้งโปรแกรมได้ ในระบบ Triple Modular Redundant (TMR) มอนิเตอร์อุณหภูมิจะติดตั้งเรียงกันเป็นกลุ่มสามตัวเพื่อรองรับตรรกะการลงคะแนนซ้ำและความทนทานต่อความผิดพลาด\u003c\/p\u003e\n\u003cp\u003eโมดูลนี้เหมาะสำหรับระบบตรวจสอบกังหัน, ชุดคอมเพรสเซอร์, โรงงานกระบวนการ, สถานีผลิตไฟฟ้า และการป้องกันเครื่องจักรอุตสาหกรรมที่ต้องการการควบคุมอุณหภูมิและการประมวลผลสัญญาณเตือน\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบอุณหภูมิหกช่องสัญญาณ\u003c\/li\u003e\n\u003cli\u003eรองรับอินพุต RTD และเทอร์โมคัปเปิล\u003c\/li\u003e\n\u003cli\u003eรองรับการกำหนดค่าช่องสัญญาณผสม RTD และ TC\u003c\/li\u003e\n\u003cli\u003eการออกแบบ I\/O แบบไม่แยกวงจรที่มีการต่อสายภายนอก\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตเครื่องบันทึกสำหรับทุกหกช่องสัญญาณ\u003c\/li\u003e\n\u003cli\u003eจุดตั้งค่าสัญญาณเตือนที่ผู้ใช้กำหนดได้\u003c\/li\u003e\n\u003cli\u003eโหมดการวัด RTD หรือ TC ที่กำหนดค่าได้ด้วยซอฟต์แวร์\u003c\/li\u003e\n\u003cli\u003eเข้ากันได้กับซอฟต์แวร์กำหนดค่าชั้นวาง 3500\u003c\/li\u003e\n\u003cli\u003eรองรับสถาปัตยกรรมระบบ TMR\u003c\/li\u003e\n\u003cli\u003eไฟ LED ด้านหน้าปุ่ม OK, TX\/RX และ Bypass\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตเครื่องบันทึก 4 ถึง 20 mA\u003c\/li\u003e\n\u003cli\u003eการตั้งค่าช่วงเต็มของช่องสัญญาณผ่านซอฟต์แวร์\u003c\/li\u003e\n\u003cli\u003eไม่ต้องสอบเทียบ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการตรวจสอบอุณหภูมิกังหันไอน้ำ\u003c\/li\u003e\n\u003cli\u003eระบบป้องกันกังหันแก๊ส\u003c\/li\u003e\n\u003cli\u003eการควบคุมอุณหภูมิของคอมเพรสเซอร์\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบเครื่องจักรหมุนในอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eระบบปิดโรงงานกระบวนการ\u003c\/li\u003e\n\u003cli\u003eการป้องกันอุปกรณ์ผลิตไฟฟ้า\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบกระบวนการปิโตรเคมี\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบเครื่องจักรในสถานี LNG\u003c\/li\u003e\n\u003cli\u003eระบบสัญญาณเตือนอุปกรณ์สำคัญ\u003c\/li\u003e\n\u003cli\u003eการติดตั้งระบบป้องกันเครื่องจักร TMR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: ชุดมอนิเตอร์ RTD\/TC ครบชุดพร้อมการต่อสายภายนอก\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eระบุชุดรวมที่ประกอบด้วยโมดูลหน้าจอหลัก 3500\/61 และบอร์ด I\/O ด้านหลังแบบไม่แยกวงจรเฉพาะ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: ตัวเลือกประเภทโมดูล I\/O\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจรพร้อมการสิ้นสุดภายนอก (หมายเลขชิ้นส่วนบอร์ดด้านหลัง: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: ตัวเลือกการอนุมัติหน่วยงาน\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eไม่ต้องการการอนุมัติหรือรับรองจากหน่วยงานพื้นที่อันตราย\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eอะไหล่และอุปกรณ์เสริม\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eหมายเลขชิ้นส่วน \u003cstrong\u003e133827-02\u003c\/strong\u003e: โมดูล I\/O RTD\/TC แบบไม่แยกวงจร 3500\/61 สำหรับเปลี่ยนทดแทนพร้อมการสิ้นสุดภายนอก\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eหมวดหมู่\u003c\/th\u003e\n\u003cth\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสินค้า\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจรสำหรับมอนิเตอร์อุณหภูมิ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eซีรีส์\u003c\/td\u003e\n\u003ctd\u003eซีรีส์ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eหมายเลขอะไหล่สำรอง\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่องสัญญาณขาเข้า\u003c\/td\u003e\n\u003ctd\u003e1 ถึง 6 สัญญาณทรานสดิวเซอร์ RTD หรือ TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานขาเข้า\u003c\/td\u003e\n\u003ctd\u003e10 เมกะโอห์มสำหรับแต่ละขั้วนำเข้า\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการใช้พลังงาน\u003c\/td\u003e\n\u003ctd\u003eกำลังไฟฟ้าปกติ 9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n\u003ctd\u003e+4 ถึง +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแรงดันไฟฟ้าสอดคล้อง\u003c\/td\u003e\n\u003ctd\u003e0 ถึง +12 Vdc ข้ามโหลด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความต้านทานโหลด\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 600 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความละเอียด\u003c\/td\u003e\n\u003ctd\u003e0.3662 ไมโครแอมป์ต่อบิต\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งจ่ายกระแส RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 ไมโครแอมป์ที่ 25 องศาเซลเซียสต่อทรานสดิวเซอร์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่วงเวลาหน่วงสัญญาณเตือน\u003c\/td\u003e\n\u003ctd\u003eการแจ้งเตือน: 1 ถึง 60 วินาที, อันตราย: 1 ถึง 60 วินาที\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n\u003ctd\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดมอนิเตอร์\u003c\/td\u003e\n\u003ctd\u003eขนาดมอนิเตอร์ 241.3 x 24.4 x 241.8 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักมอนิเตอร์\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักมอนิเตอร์ 0.91 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eขนาดโมดูล I\/O\u003c\/td\u003e\n\u003ctd\u003eขนาดโมดูล I\/O 241.3 x 24.4 x 99.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักโมดูล I\/O\u003c\/td\u003e\n\u003ctd\u003eน้ำหนักโมดูล I\/O 0.45 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eข้อกำหนดช่องแร็ค\u003c\/td\u003e\n\u003ctd\u003eช่องด้านหน้าสูงเต็ม 1 ช่องและช่องด้านหลัง 1 ช่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งกำเนิด\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนด RTD\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิด RTD\u003c\/td\u003e\n\u003ctd\u003eช่วงการวัด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD แพลตตินัม 100 โอห์ม อัลฟา 0.00385\u003c\/td\u003e\n\u003ctd\u003e-200 องศาเซลเซียส ถึง +850 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD แพลตตินัม 100 โอห์ม อัลฟา 0.00392\u003c\/td\u003e\n\u003ctd\u003e-200 องศาเซลเซียส ถึง +700 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD นิกเกิล 120 โอห์ม\u003c\/td\u003e\n\u003ctd\u003e-80 องศาเซลเซียส ถึง +260 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD ทองแดง 10 โอห์ม\u003c\/td\u003e\n\u003ctd\u003e-100 องศาเซลเซียส ถึง +260 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดเทอร์โมคัปเปิล\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิดเทอร์โมคัปเปิล\u003c\/td\u003e\n\u003ctd\u003eช่วงการวัด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิด E\u003c\/td\u003e\n\u003ctd\u003e-100 องศาเซลเซียส ถึง +1000 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิด J\u003c\/td\u003e\n\u003ctd\u003e-18 องศาเซลเซียส ถึง +760 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิด K\u003c\/td\u003e\n\u003ctd\u003e-18 องศาเซลเซียส ถึง +1370 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eชนิด T\u003c\/td\u003e\n\u003ctd\u003e-160 องศาเซลเซียส ถึง +400 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดการปรับสัญญาณ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eพารามิเตอร์\u003c\/td\u003e\n\u003ctd\u003eข้อกำหนด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความละเอียดของ RTD และ TC\u003c\/td\u003e\n\u003ctd\u003e1 องศาเซลเซียสหรือ 1 องศาฟาเรนไฮต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความละเอียดของ RTD ทองแดง\u003c\/td\u003e\n\u003ctd\u003e1 องศาเซลเซียสหรือ 1 องศาฟาเรนไฮต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำของการชดเชยจุดต่อเย็น\u003c\/td\u003e\n\u003ctd\u003e+\/-1 องศาเซลเซียสที่ 25 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำของสัญญาณเตือน\u003c\/td\u003e\n\u003ctd\u003eภายใน 0.13% ของค่าที่ต้องการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำของการสิ้นสุดภายนอกแบบไม่แยกวงจร\u003c\/td\u003e\n\u003ctd\u003e+\/-1 องศาเซลเซียสที่ 25 องศาเซลเซียสสำหรับแร็คมาตรฐาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eความแม่นยำของแร็คแบบบัลค์เฮด\u003c\/td\u003e\n\u003ctd\u003e+\/-3 องศาเซลเซียสที่ 25 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eเอาต์พุตและตัวบ่งชี้\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eตัวบ่งชี้หรือเอาต์พุต\u003c\/td\u003e\n\u003ctd\u003eฟังก์ชัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eไฟ LED OK\u003c\/td\u003e\n\u003ctd\u003eแสดงการทำงานของมอนิเตอร์ที่ถูกต้อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eไฟ LED TX\/RX\u003c\/td\u003e\n\u003ctd\u003eแสดงการสื่อสารกับโมดูลแร็ค\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eไฟ LED บายพาส\u003c\/td\u003e\n\u003ctd\u003eแสดงโหมดบายพาส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n\u003ctd\u003eเอาต์พุต 4 ถึง 20 mA แยกตามช่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกทางวิศวกรรม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eตัวเลือก Platinum RTD\u003c\/strong\u003e: Platinum RTD ที่มีสัมประสิทธิ์อัลฟา 0.00385 เป็นไปตามมาตรฐานอุตสาหกรรมทั่วโลกและแนะนำสำหรับการติดตั้งวงจรอุณหภูมิใหม่ทั้งหมด\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eความทนทานต่อการลัดวงจรของเครื่องบันทึก\u003c\/strong\u003e: วงจรภายในรับประกันว่าเครื่องตรวจวัดหลักและตรรกะสัญญาณเตือนจะไม่ถูกกระทบกระเทือนจากการลัดวงจรในวงจรเครื่องบันทึกภายนอก\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eจุดตั้งค่าต่ำและสูง\u003c\/strong\u003e: เครื่องประมวลผลภายในให้ขอบเขตสัญญาณเตือนทั้งบนและล่างเพื่อการป้องกันหลายทิศทาง (เช่น สภาวะเยือกแข็งหรือความร้อนเกิน)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eข้อกำหนด TMR\u003c\/strong\u003e: เมื่อกำหนดค่าเป็น Triple Modular Redundancy ต้องมีเครื่องตรวจวัดอุณหภูมิที่เหมือนกันสามเครื่องติดตั้งในช่องแชสซีด้านหน้าที่อยู่ติดกันสามช่อง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eแนวทางภาคสนาม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเดินสายต่อภายนอก\u003c\/strong\u003e: นำสาย RTD หรือ TC ทั้งหมดไปยังบล็อกต่อภายนอกโดยให้การเชื่อมต่อสะอาดและแน่นหนาเพื่อรักษาความแม่นยำของ CJC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการต่อสายกราวด์ของชิลด์\u003c\/strong\u003e: ต่อสายชิลด์ของสายเคเบิลเฉพาะที่เทอร์มินัลกราวด์ชิลด์ที่กำหนดบนโมดูล I\/O เพื่อป้องกันวงจรกราวด์และป้องกันสัญญาณรบกวนแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจับคู่เซ็นเซอร์ CJC\u003c\/strong\u003e: ตรวจสอบให้แน่ใจว่าเซ็นเซอร์ชดเชยจุดเย็น (Cold Junction Compensation) ติดตั้งอย่างแน่นหนาที่ฐานเทอร์มินัลเพื่อการชดเชยสภาพแวดล้อมที่ถูกต้องในระหว่างการวัดเทอร์โมคัปเปิล\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการลดความต้านทานของสายไฟ\u003c\/strong\u003e: สำหรับการเชื่อมต่อ RTD แบบ 3 สายและ 4 สาย ให้รักษาความยาวสายไฟให้เท่ากันเพื่อปรับสมดุลแรงดันตกและรับประกันการชดเชยสะพานที่แม่นยำ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อยด้านเทคนิคและการจัดซื้อ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ความแตกต่างหลักระหว่างโมดูล 3500\/60 กับ 3500\/61 คืออะไร?\u003c\/strong\u003e ตอบ: ทั้งสองโมดูลมีการตรวจวัดอุณหภูมิและตรรกะสัญญาณเตือนเหมือนกัน แต่ 3500\/61 มีเอาต์พุตเครื่องบันทึกแยกอิสระ +4 ถึง +20 mA จำนวนหกช่อง ในขณะที่ 3500\/60 ไม่มี\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ตัวเลือกโมดูล I\/O แบบไม่แยกส่วนนี้มีการแยกช่องสัญญาณต่อช่องสัญญาณหรือไม่?\u003c\/strong\u003e ตอบ: ไม่ใช่ นี่คือตัวเลือก 02 ซึ่งไม่แยกส่วน; หากต้องการการแยกช่องสัญญาณเพื่อป้องกันความผิดพลาดของกราวด์หนักหรือการข้ามสายแรงดันสูง ควรระบุเวอร์ชันโมดูล I\/O แบบแยกส่วนแทน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ต้องมีการปรับเทียบภาคสนามสำหรับโมดูล 3500\/61 เมื่อทำการติดตั้งหรือไม่?\u003c\/strong\u003e ตอบ: ไม่จำเป็นต้องปรับเทียบภาคสนามเนื่องจากช่วงเต็มสเกลและประเภทเซ็นเซอร์ถูกตั้งค่าดิจิทัลโดยใช้ซอฟต์แวร์ 3500 Rack Configuration\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 Low Current 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e is a \u003cstrong\u003e16-channel failsafe relay output module\u003c\/strong\u003e used as a main or spare module in \u003cstrong\u003e3500 machinery protection systems\u003c\/strong\u003e. It provides 16 independently programmable relay outputs with alarm drive logic, supporting AND\/OR logic combinations of alert, danger, Not-OK statuses, and measured variables from any monitor channel. Each relay output can perform voting logic and integrates with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module interfaces with \u003cstrong\u003ePLC, DCS, SIS, and TSI systems\u003c\/strong\u003e, offering both normally de-energized (ND) and normally energized (NE) operation selectable in four groups of four channels. Front-panel LEDs indicate module status, communication activity, and channel alarm states.\u003c\/p\u003e\n\u003cp\u003eIt supports low current switching applications with gold-plated contacts, suitable for standard, failsafe, or hazardous area configurations. Module compatibility includes installation to the right of the Transient Data Interface (TDI) in a \u003cstrong\u003e3500 rack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with independent programmable logic\u003c\/li\u003e\n\u003cli\u003eAlarm drive logic using AND\/OR conditions\u003c\/li\u003e\n\u003cli\u003eSelectable normally de-energized (ND) or normally energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs for OK, TX\/RX, and channel alarm status\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relays with arc suppressors (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eRelay life up to 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLow current gold-plated contact option for 1 mA @ 1 Vdc minimum load\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial machinery monitoring and protection\u003c\/li\u003e\n\u003cli\u003eProcess automation alarm outputs\u003c\/li\u003e\n\u003cli\u003eHazardous area relay interfacing\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC, DCS, SIS, TSI systems\u003c\/li\u003e\n\u003cli\u003eLow-current signal switching in control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Complete 16-Channel Relay Module Assembly\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the pre-configured combination consisting of the front main module card and the rear low-current failsafe output board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Output Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLow Current 16-Channel Failsafe Relay Output Module featuring gold-plated contacts (Rear I\/O Module Spare: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Hazardous Area Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e149992-04\u003c\/strong\u003e: Spare 16-Channel Low Current Failsafe Relay Output Module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain module: 0.7 kg (1.6 lb), I\/O module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMain module: 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in), I\/O module: 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003eMain: 1 full-height front slot, I\/O: 1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSPDT (Single-pole Double-throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA @ 5 Vdc, Low Current: 1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003eDC: 5 A, AC: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003eDC: 70 W @ 24 Vdc, AC: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003eDC: 125 Vdc, AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, CH Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eRefer to 3500 rack manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay outputs, power, communication connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eGrounding and Shielding\u003c\/h4\u003e\n\u003cp\u003eEnsure the rack frame is properly tied to the plant instrumentation ground before inserting modules. Field wiring shields should be terminated at the designated shield terminals on the I\/O module to minimize electromagnetic interference and ensure signal integrity.\u003c\/p\u003e\n\u003ch4\u003eHazardous Area Precautions\u003c\/h4\u003e\n\u003cp\u003eDo not disconnect field wiring or module connections while the circuit is live unless the location is verified to be non-hazardous. Live handling in explosive atmospheres can result in arc-induced ignition risks.\u003c\/p\u003e\n\u003ch4\u003eModule Placement\u003c\/h4\u003e\n\u003cp\u003eAlign the main module with the chosen front slot to the right of the TDI module. Slide it firmly into the backplane connectors and tighten the panel screws. Install the matching I\/O module in the corresponding slot directly on the rear of the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 04 option signify in this module part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The 04 code specifies that this is the Low Current 16-Channel Failsafe variant equipped with gold-plated contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum current rating for the gold-plated contact version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum switched current rating is 1 mA @ 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the configuration for Normally Energized and Normally De-energized modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the sixteen channels are split into four distinct groups of four channels, and each group is independently switch-selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the TX\/RX LED on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TX\/RX LED flashes to indicate active transmission and reception of communication data between this module and other rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware package contain built-in spark protection for the contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, an internal 250 Vrms epoxy-sealed relay arc suppressor is standard equipment on the hardware channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit process individual variables from multiple monitor modules at once?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Alarm Drive Logic can combine Alert, Danger, or Not-OK inputs from any monitor channel or combination of monitor channels within the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software tool is required to configure the voting logic pathways?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system logic is engineered and uploaded using the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the relay operation if the module encounters an internal failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Failsafe design ensures that when a major failure or loss of control occurs, the relays drop to their safe de-energized or default state depending on wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to exceed 5 mA when using an AC supply voltage up to 120Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, currents exceeding 5 mA on these low-current gold relays will degrade or permanently damage the contact plating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does the complete main and I\/O assembly take up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt occupies one full-height slot on the front of the rack and one corresponding full-height slot on the rear panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into the slot immediately adjacent to the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt must be placed in any available slot situated to the right of the Transient Data Interface module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a solid light on the OK LED indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid light confirms that the hardware is powered up, has passed initial self-tests, and is operating properly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-15-04-04-01-133300-01-legacy-low-voltage-dc-power-input-module","title":"เบนท์ลีย์ เนวาด้า 3500\/15-04-04-01 133300-01 โมดูลอินพุตพลังงาน DC แรงดันต่ำรุ่นเก่า","description":"\u003cp style=\"color: #2d3748;\"\u003e\u003cstrong\u003eBently Nevada 3500\/15-04-04-01\u003c\/strong\u003e ทำงานร่วมกับอินเทอร์เฟซด้านหลัง \u003cstrong\u003e133300-01\u003c\/strong\u003e เป็นเครื่องแปลงพลังงานแร็คครึ่งความสูงระดับอุตสาหกรรมที่ออกแบบมาสำหรับระบบปกป้องเครื่องจักรชุด 3500 ซีรีส์ ชุดฮาร์ดแวร์นี้สร้างโครงสร้างพื้นฐานอินพุตกระแสตรงแรงดันต่ำรุ่นเก่า รับแรงดันไฟฟ้าจากแหล่งจ่ายไฟโรงงานดิบและดำเนินการควบคุมแรงดันลดขั้นสูงเพื่อจ่ายแรงดันไฟฟ้ากระแสตรงที่ตรวจสอบอย่างเข้มงวดให้กับแร็คหลังแบบพาสซีฟภายในระบบ\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eคุณสมบัติหลัก\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eโทโพโลยีซ้ำซ้อน N+1 แท้จริง:\u003c\/strong\u003e รองรับการจัดสรรแหล่งจ่ายไฟคู่ต่อเนื่องภายในการกำหนดค่าแร็คเดียว โดยช่องล่างทำหน้าที่เป็นแหล่งพลังงานหลักและช่องบนเป็นหน่วยสแตนด์บายร้อนที่ไม่ขัดจังหวะ\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eการเปลี่ยนแบบร้อนโดยไม่หยุดทำงาน:\u003c\/strong\u003e วงจรปรับสมดุลแบบไดนามิกภายในอนุญาตให้ถอดหรือใส่การ์ดพลังงานใดก็ได้ในขณะที่แร็คเครื่องจักรยังคงเปิดใช้งานเต็มที่ ป้องกันการตัดการทำงานผิดพลาดหรือจุดบอดการป้องกัน\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eเกราะกั้นแยกวงจรไฟฟ้า:\u003c\/strong\u003e ออกแบบด้วยเส้นทางวงจรแยกอย่างชัดเจนระหว่างเทอร์มินัลอินพุตและการเชื่อมต่อแผงหลังเพื่อดูดซับแรงดันไฟฟ้าชั่วขณะและความผันผวนของกราวด์ลูปขนาดใหญ่\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eโมดูลอินพุตพลังงานเฉพาะ (PIM):\u003c\/strong\u003e จับคู่กับโมดูลด้านหลังรุ่นเก่า 133300-01 ที่มีบล็อกเทอร์มินัลแข็งแรงและพื้นที่กรองอินพุตที่ปรับแต่งสำหรับแบตเตอรี่แรงดันต่ำ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eการปกป้องเครื่องจักรหมุนความสำคัญสูง:\u003c\/strong\u003e จ่ายแรงดันไฟฟ้าคงที่สำหรับโมดูลตรวจจับการสั่นสะเทือนเพลาหลัก ตำแหน่งแรงดัน และความเร็วในชุดเครื่องจักรไอน้ำและกังหันแก๊ส\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eการรวมแบตเตอรี่โรงงาน:\u003c\/strong\u003e การเชื่อมต่อโดยตรงกับระบบแบตเตอรี่สำรอง 24V DC กลางในโรงงานผลิตไฟฟ้าและโรงงานแปรรูปปิโตรเคมี\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eตู้ควบคุมความพร้อมใช้งานสูง:\u003c\/strong\u003e ใช้งานในตู้เครื่องจักรระยะไกลที่ต้องการเวลาทำงานระบบสูงสุดผ่านแหล่งจ่ายไฟเครื่องมือซ้ำซ้อน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eรหัสตัวเลือก\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eรายละเอียดการเลือกวิศวกรรม\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eการกำหนดค่าพื้นฐาน 3500\/15-AA-BB-CC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eแหล่งจ่ายไฟ DC แรงดันต่ำรุ่นเก่า (ช่วง 20 ถึง 30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eโมดูลอินพุตพลังงาน DC แรงดันต่ำรุ่นเก่า (PIM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eCC - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเลือกการอนุมัติจากหน่วยงาน: CSA-c-US (ชั้น I, แผนก 2, กลุ่ม A, B, C, D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eหมายเลขชิ้นส่วนแยกส่วนประกอบ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e106M1081-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eชุดการ์ดหลักแหล่งจ่ายไฟ DC แรงดันต่ำรุ่นเก่า\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e133300-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eโมดูลอินพุตพลังงาน DC แรงดันต่ำรุ่นเก่า (PIM) ฮาร์ดแวร์ด้านหลัง\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eพารามิเตอร์ทางเทคนิค\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eค่าทางวิศวกรรมที่ตรวจสอบแล้ว\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงแรงดันไฟฟ้าขาเข้า\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eช่วงแรงดันไฟฟ้าขาเข้า 20 Vdc ถึง 30 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eกระแสไฟขาเข้าสูงสุด\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10.0 A ต่อเนื่อง\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eการใช้พลังงานทั่วไป\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eกำลังไฟสูงสุด 230 วัตต์ ภายใต้การโหลดโครงเต็มรูปแบบ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eรางจ่ายไฟที่ควบคุมแรงดัน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+5 Vdc, -5 Vdc, +15 Vdc, -15 Vdc กระจายผ่านแบ็คเพลนแบบพาสซีฟ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความแข็งแรงการแยกไดอิเล็กทริก\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eค่าความต้านทานต่อกราวด์เทอร์มินัลถึงโครง 500 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดรูปแบบ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eรูปแบบการ์ดครึ่งความสูง (ครอบครองช่องแร็คด้านซ้ายเฉพาะ)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขีดจำกัดอุณหภูมิการทำงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 องศาเซลเซียส ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขีดจำกัดอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงความชื้นสัมพัทธ์\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eความชื้นสัมพัทธ์สูงสุด 95% ไม่ควบแน่น\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eการตรวจสอบสถานะแผงด้านหน้า\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eเมทริกซ์ไดโอด LED สีเขียวแบบบูรณาการ 'Supply OK'\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (บริษัทในเครือ Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักการ์ดจ่ายไฟหลัก\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.77 กก. (1.70 ปอนด์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักการ์ด PIM ด้านหลัง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.31 กก. (0.68 ปอนด์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักสุทธิรวมของระบบ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.08 กก. (2.38 ปอนด์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.55 กก. (ระบบกล่องการ์ดคู่ครบชุด)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e285 มม. x 210 มม. x 155 มม.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eการกำหนดเทอร์มินัล\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eการกำหนดอินเทอร์เฟซวงจร\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสายป้อนไฟ DC บวก (รับแรงดันอ้างอิง +20 ถึง +30 Vdc)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสายส่งกลับ DC ลบ (เส้นทางส่งกลับทั่วไปของวงจรพลังงาน)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eการเชื่อมต่อสายดินความปลอดภัย (เส้นทางเชื่อมโลหะโดยตรงกับโครง)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eคำเตือนสำคัญ:\u003c\/strong\u003e แยกเบรกเกอร์วงจรจ่ายไฟ DC 24V หลักก่อนเริ่มติดตั้ง หลีกเลี่ยงการจัดการหรือเดินสายไฟที่มีไฟฟ้าสดโดยตรงกับบล็อกอัดด้านหลังของ 133300-01 การเชื่อมต่อสายไฟที่มีไฟฟ้าสดเสี่ยงต่อการเกิดประกายไฟอย่างต่อเนื่อง วงจรลัดวงจรภายในชั้นทองแดง และความเสียหายถาวรของการ์ดตรวจสอบทั้งหมดบนแบ็คเพลนร่วม\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eเชื่อมต่อสายรัดข้อมือป้องกันไฟฟ้าสถิตที่ตรวจสอบแล้วกับโครงเหล็กที่ไม่ได้ทาสีของแร็คเพื่อปล่อยประจุไฟฟ้าสถิตส่วนบุคคลก่อนเปิดซองป้องกันโมดูล\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eดันการ์ดพลังงานครึ่งความสูงหลักลงในรางช่องเฉพาะที่ด้านหน้าซ้ายของโครง 3500 อย่างราบรื่นจนเข้ากับชุดขั้วต่อพินแบ็คเพลน\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eจัดตำแหน่งการ์ดป้อนพลังงานรุ่นเก่า 133300-01 เข้ากับช่องด้านหลังแบบขนาน ขันสกรูยึดด้านหลังให้แน่นเพื่อยึดอุปกรณ์ไม่ให้สั่นสะเทือนจากแรงสั่นสะเทือนทางกลอย่างต่อเนื่อง\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eลอกสายป้อนฟีดเดอร์ออก 7 มิลลิเมตร ใส่สายให้แน่นในบล็อกหนีบเทอร์มินัล DC โดยจับคู่ขั้วที่ตรวจสอบแล้ว และขันสกรูหนีบให้แน่นตามข้อกำหนด\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850673003,"sku":"3500\/15-04-04-01 133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-01-133300-01-low-voltage-dc-power-input-module-jkcdk13hega_bc249377-abc5-4e7b-890f-e8d2efa9342f.jpg?v=1765449036"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"เครื่องตรวจวัดอุณหภูมิแบบอินพุตเทอร์โมคัปเปิล 6 ช่อง Bently Nevada 3300\/30","description":"\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูลตรวจสอบอุณหภูมิหกช่องที่ออกแบบมาสำหรับระบบตรวจสอบ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e รุ่นเก่า\u003cbr\u003eเวอร์ชันนี้ถูกกำหนดค่าเฉพาะเพื่อรับ\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eอินพุตเทอร์โมคัปเปิล (TC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eแทนเซ็นเซอร์ RTD\u003c\/p\u003e\n\u003cp\u003eโดยทั่วไปใช้เพื่อตรวจสอบจุดอุณหภูมิที่สำคัญในเครื่องจักรอุตสาหกรรม รวมถึง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิของโลหะแบริ่ง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิแก๊สไอเสีย\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิขดลวดสเตเตอร์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิน้ำมันหล่อลื่น\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eเครื่องมอนิเตอร์ให้การป้องกันอย่างต่อเนื่องผ่านรีเลย์สัญญาณเตือนที่ตั้งค่าได้และเอาต์พุตเครื่องบันทึกมาตรฐาน เพื่อให้การควบคุมอุณหภูมิในเครื่องกำเนิดไฟฟ้า, คอมเพรสเซอร์ และกังหันเป็นไปอย่างเชื่อถือได้\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h2\u003e\n\u003ch3\u003e1. อินพุต\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eความจุอินพุต\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eรองรับสูงสุด\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eหก (6) อินพุตเทอร์โมคัปเปิลอิสระ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eแต่ละช่องทำงานอย่างอิสระ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eประเภทเทอร์โมคัปเปิลที่รองรับ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eประเภท\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— เหล็ก \/ คอนสแตนตัน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eประเภท\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— โครเมล \/ อลูเมล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eประเภท\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— โครเมล \/ คอนสแตนตัน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eประเภท\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— ทองแดง \/ คอนสแตนตัน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eการชดเชยจุดเย็น\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eมีการชดเชยภายในที่บล็อกเทอร์มินัล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eแก้ไขการลอยของการวัดโดยอัตโนมัติที่เกิดจากการเปลี่ยนแปลงอุณหภูมิรอบข้าง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eรับประกันความแม่นยำของอุณหภูมิที่เสถียรในสภาพแวดล้อมการทำงาน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. การปรับสัญญาณ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eความแม่นยำ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eภายใน\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% ของสัญญาณ\u003c\/strong\u003e บวกความคลาดเคลื่อนของเทอร์โมคัปเปิล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุณหภูมิอ้างอิง:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eการตรวจจับเทอร์โมคัปเปิลเปิด\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเครื่องมอนิเตอร์มีการตรวจจับข้อผิดพลาดอัตโนมัติเมื่อวงจรเทอร์โมคัปเปิลเปิด\u003c\/p\u003e\n\u003cp\u003eโหมดตอบสนองที่เลือกได้:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการขับเคลื่อนเพิ่มค่า\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— บังคับให้อ่านค่าสูง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการขับเคลื่อนลดค่า\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— บังคับให้อ่านค่าต่ำ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eฟีเจอร์นี้ป้องกันไม่ให้เครื่องจักรทำงานโดยไม่มีการป้องกันอุณหภูมิ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eอัตราการสแกน\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eสแกนทั้งหกช่องประมาณ:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 วินาทีต่อรอบ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eความเร็วสแกนนี้เป็นแบบทั่วไปสำหรับระบบป้องกันเครื่องจักรที่การเปลี่ยนแปลงอุณหภูมิเป็นไปอย่างค่อยเป็นค่อยไปเมื่อเทียบกับสัญญาณการสั่นสะเทือน\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. เอาต์พุต\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eเอาต์พุตเครื่องบันทึก\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเอาต์พุตแอนะล็อกที่ผู้ใช้ตั้งโปรแกรมได้:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 ถึง +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 ถึง -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 ถึง +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eเอาต์พุตบัฟเฟอร์\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eมีให้สำหรับวัตถุประสงค์ในการวินิจฉัยและตรวจสอบ:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eตัวเชื่อมต่อโคแอกเชียลแผงด้านหน้า\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eการเชื่อมต่อบล็อกเทอร์มินัลด้านหลัง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eเอาต์พุตบัฟเฟอร์หนึ่งช่องต่อหนึ่งช่อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eเอาต์พุตเหล่านี้มักเชื่อมต่อกับ:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eระบบ DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eระบบ PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eเครื่องบันทึกข้อมูล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eซอฟต์แวร์ตรวจสอบสภาพ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. สัญญาณเตือน \u0026amp; การแสดงผล\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eแสดงผล\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eจอแสดงผลอุณหภูมิ LCD 7-segment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eแสดงค่าความร้อนแบบเรียลไทม์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eการเลือกช่อง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eใช้ปุ่ม\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eแสดงผล\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eหมุนเวียนผ่านช่อง 1 ถึง ช่อง 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eจุดตั้งค่าสัญญาณเตือน\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eแต่ละช่องรองรับการตั้งค่าสัญญาณเตือนอิสระ:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eสัญญาณเตือนแจ้งเตือน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eสัญญาณเตือนอันตราย\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eทั้งสองเกณฑ์สามารถปรับได้เต็มที่\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตัวบ่งชี้ OK\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eไฟ LED OK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eตรวจสอบสุขภาพระบบอย่างต่อเนื่อง รวมถึง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eอิเล็กทรอนิกส์มอนิเตอร์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eเซ็นเซอร์เทอร์โมคัปเปิล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eความสมบูรณ์ของสายไฟภาคสนาม\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eข้อมูลการสั่งซื้อ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eรูปแบบการสั่งซื้อ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — ตัวเลือกช่วงเต็มสเกล\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eรหัส\u003c\/th\u003e\n\u003cth class=\"\"\u003eช่วงอุณหภูมิ\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 ถึง 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 ถึง 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 ถึง 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 ถึง 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — ตัวเลือกอินพุตเทอร์โมคัปเปิล\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eรหัส\u003c\/th\u003e\n\u003cth class=\"\"\u003eชนิดเทอร์โมคัปเปิล\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eชนิด J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eชนิด K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eชนิด E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eชนิด T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — ตัวเลือกรีเลย์สัญญาณเตือน\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eรหัส\u003c\/th\u003e\n\u003cth class=\"\"\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eไม่มีรีเลย์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eรีเลย์ปิดผนึกด้วยอีพ็อกซี่\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eรีเลย์ปิดผนึกแบบเฮอร์เมติก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — ตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eรหัส\u003c\/th\u003e\n\u003cth class=\"\"\u003eการรับรอง\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eไม่จำเป็น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eการรับรองตนเอง ATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — ตัวเลือกอุปสรรคความปลอดภัย\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eรหัส\u003c\/th\u003e\n\u003cth class=\"\"\u003eคำอธิบาย\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eไม่มี\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eอุปสรรคภายนอก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eอุปสรรคภายใน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eคู่มือวิศวกรรมและการติดตั้ง\u003c\/h2\u003e\n\u003ch3\u003eข้อกำหนดพื้นที่\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eเครื่องมอนิเตอร์อุณหภูมิ 3300\/30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eคือ:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลกว้างสองเท่า\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eข้อกำหนดการติดตั้ง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eใช้\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eช่องว่างสอง (2) ช่อง\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eในแร็ค 3300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eสิ่งนี้สำคัญเมื่อวางแผนความจุแร็คในโครงการปรับปรุงหรือขยาย\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eข้อกำหนดสายเทอร์โมคัปเปิล\u003c\/h3\u003e\n\u003cp\u003eใช้\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eสายต่อเทอร์โมคัปเปิล\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eที่ถูกต้องซึ่งตรงกับชนิดเทอร์โมคัปเปิลเสมอ\u003c\/p\u003e\n\u003cp\u003eตัวอย่าง:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eชนิด K → สายต่อชนิด K\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eชนิด J → สายต่อชนิด J\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eการใช้สายทองแดงมาตรฐานจะทำให้เกิด:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eข้อผิดพลาดแรงดันไฟฟ้าจุดต่อ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eการลอยของการวัดอุณหภูมิ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eความไม่แม่นยำในการสอบเทียบ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eนี่คือหนึ่งในข้อผิดพลาดที่พบบ่อยที่สุดในการติดตั้งภาคสนาม\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eแนวปฏิบัติการต่อสายดิน\u003c\/h3\u003e\n\u003cp\u003eวิธีการต่อสายดินที่แนะนำ:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eต่อสายดินของชิลด์เทอร์โมคัปเปิลที่แร็คมอนิเตอร์เท่านั้น\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eหลีกเลี่ยงการต่อสายดินหลายจุด\u003c\/p\u003e\n\u003cp\u003eการต่อสายดินไม่ถูกต้องอาจทำให้เกิด:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eลูปกราวด์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eสัญญาณรบกวน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eการอ่านอุณหภูมิที่ไม่เสถียร\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eต้องให้ความสนใจเป็นพิเศษเมื่อใช้:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eเทอร์โมคัปเปิลปลายต่อสายดิน\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเซ็นเซอร์เหล่านี้ไวต่อการตั้งค่าการต่อสายดินมากขึ้น\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eการควบคุมสภาพแวดล้อมจุดเย็น\u003c\/h3\u003e\n\u003cp\u003eอย่าติดตั้งแร็คมอนิเตอร์ในสถานที่ที่มี:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eการเปลี่ยนแปลงอุณหภูมิอย่างรวดเร็ว\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eกระแสลมแรงผ่านบล็อกเทอร์มินัล\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eความชันของอุณหภูมิสูง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eสภาพเหล่านี้อาจส่งผลต่อความแม่นยำของการชดเชยจุดเย็นภายใน\u003c\/p\u003e\n\u003cp\u003eตำแหน่งที่มักมีปัญหา:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eใกล้ท่อระบายอากาศ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eใกล้เส้นทางไอเสียของกังหัน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eแผงกลางแจ้งที่ไม่มีฉนวนกันความร้อน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"โมดูล I\/O Ethernet\/RS232 Modbus Bently Nevada 3500\/92-03-01-00 136188-01","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e เป็น \u003cstrong\u003eโมดูลเกตเวย์การสื่อสาร\u003c\/strong\u003e ที่ออกแบบมาสำหรับ \u003cstrong\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/strong\u003e จุดประสงค์หลักคือเพื่อให้ความสามารถในการสื่อสารความเร็วสูงอย่างต่อเนื่องสำหรับค่าทั้งหมดและสถานะที่ตรวจสอบโดยแร็ค ช่วยให้การบูรณาการกับระบบควบคุมแบบกระจาย (DCS), ตัวควบคุมลอจิกแบบโปรแกรมได้ (PLC), ส่วนติดต่อมนุษย์กับเครื่องจักร (HMI) และระบบอัตโนมัติในโรงงานอื่น ๆ เป็นไปอย่างราบรื่น  \u003c\/p\u003e\n\u003cp\u003eโมดูลนี้มีอินเทอร์เฟซการสื่อสารที่ครอบคลุม ใช้ทั้งช่องทาง Ethernet TCP\/IP และอนุกรม (RS232) ผ่าน \u003cstrong\u003eโมดูล I\/O 136188-01\u003c\/strong\u003e โดยจัดการการเก็บข้อมูลภายในโดยดึงค่าที่วัดได้ปัจจุบัน เวลาประทับ สถานะโมดูล และสถานะสัญญาณเตือนจากโมดูลตรวจสอบอื่น ๆ ภายในแร็คผ่านเครือข่ายภายในความเร็วสูง นอกจากนี้ \u003cstrong\u003e3500\/92\u003c\/strong\u003e ยังรองรับการสื่อสาร Ethernet โดยตรงกับ \u003cstrong\u003eซอฟต์แวร์กำหนดค่าแร็ค 3500\u003c\/strong\u003e และ \u003cstrong\u003eซอฟต์แวร์เก็บข้อมูล\u003c\/strong\u003e รุ่นเฉพาะนี้มียูทิลิตี้ Modbus Register ที่ปรับแต่งได้เพื่อแมปข้อมูลระบบอย่างมีประสิทธิภาพเข้าสู่เครือข่ายระบบอัตโนมัติของโฮสต์  \u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการเก็บข้อมูลแร็คอย่างต่อเนื่อง รวมถึงค่าที่วัดได้ปัจจุบันพร้อมเวลาประทับสถานะโมดูล และสถานะสัญญาณเตือน  \u003c\/li\u003e\n\u003cli\u003eความสามารถในการสื่อสารพร้อมกันผ่าน Ethernet TCP\/IP และลิงก์อนุกรม  \u003c\/li\u003e\n\u003cli\u003eยูทิลิตี้ Modbus Register ที่ปรับแต่งได้เพื่อกำหนดแผนที่รีจิสเตอร์สำหรับระบบโฮสต์  \u003c\/li\u003e\n\u003cli\u003eอัตราการเก็บข้อมูลเครือข่ายภายในความเร็วสูงที่อัปเดตโมดูลทั้งหมดในแร็คภายในเวลาไม่ถึง 1 วินาที  \u003c\/li\u003e\n\u003cli\u003eไฟ LED บนแผงหน้าปัดสำหรับการตรวจสอบสถานะการทำงานของโมดูล (OK) และกิจกรรมการสื่อสาร (TX\/RX) ทันที  \u003c\/li\u003e\n\u003cli\u003eความเข้ากันได้ย้อนหลังกับฟีเจอร์ซอฟต์แวร์ของโมดูล 3500\/90 ดั้งเดิม  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการบูรณาการการตรวจสอบการสั่นสะเทือนและสถานะของกังหันไอน้ำและกังหันแก๊ส  \u003c\/li\u003e\n\u003cli\u003eการส่งข้อมูลป้องกันคอมเพรสเซอร์และปั๊มไปยัง DCS ของโรงงาน  \u003c\/li\u003e\n\u003cli\u003eเครือข่ายการตรวจสอบสภาพเครื่องจักรอุตสาหกรรมและการบำรุงรักษาเชิงคาดการณ์  \u003c\/li\u003e\n\u003cli\u003eการซิงโครไนซ์ระบบอัตโนมัติในโรงไฟฟ้าและโรงงานปิโตรเคมี  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: เกตเวย์การสื่อสาร  \u003c\/li\u003e\n\u003cli\u003e03: โมดูล I\/O Ethernet\/RS232 Modbus  \u003c\/li\u003e\n\u003cli\u003e01: หน่วยความจำต่ำ\u003c\/li\u003e\n\u003cli\u003e00: ไม่มีตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/li\u003e\n\u003cli\u003e136188-01: โมดูล I\/O Ethernet\/RS232 Modbus สำรอง (รวมชุดอัปเกรดเฟิร์มแวร์ 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: ชุดอัปเกรดเฟิร์มแวร์\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eประเทศต้นทาง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eใช้พลังงาน 5.0 วัตต์โดยทั่วไปกับโมดูล I\/O Modbus RS232\/RS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eประเภทข้อมูล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eค่าปัจจุบันวัดพร้อมเวลาประทับ, สถานะโมดูล, สถานะสัญญาณเตือนปัจจุบัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eเวลาการอัปเดต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eใช้เวลาน้อยกว่า 1 วินาทีสำหรับโมดูลทั้งหมดในแร็ค 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eเอาต์พุต LED OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eแสดงเมื่อ 3500\/92 ทำงานอย่างถูกต้อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eเอาต์พุต LED TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eแสดงเมื่อ 3500\/92 กำลังสื่อสารกับโมดูลอื่นในแร็ค 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eโปรโตคอลโฮสต์ BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eการเชื่อมต่อ Ethernet TCP\/IP กับซอฟต์แวร์กำหนดค่าและเก็บข้อมูล 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eโปรโตคอล Modbus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eอ้างอิงจากคู่มือ AEG Modicon PI-MBUS-300 โหมดส่งข้อมูล Remote Terminal Unit (RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eความเร็วลิงก์ Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eความเร็วลิงก์ Ethernet 10 Mbps ตามมาตรฐาน IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eโปรโตคอล Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eเฟรม Ethernet TCP\/IP และ Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eการเชื่อมต่อ Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 สำหรับสายเคเบิล Ethernet 10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส (-22 องศาฟาเรนไฮต์ ถึง +149 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eความชื้น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eความชื้น 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eขนาดบอร์ดหลัก (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 มม. x 24.4 มม. x 242 มม. (9.50 นิ้ว x 0.96 นิ้ว x 9.52 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eขนาดโมดูล I\/O (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 มม. x 24.4 มม. x 99.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 3.90 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eน้ำหนักบอร์ดหลัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0.82 กก. (1.8 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eน้ำหนักโมดูล I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.44 กก. (0.96 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eน้ำหนักรวมประกอบ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1.26 กก. (2.76 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eขาเชื่อมต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eแจ็ค RJ-45\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eอินเทอร์เฟซ Ethernet TCP\/IP 10BASE-T และ Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eพอร์ตอนุกรม (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eอินเทอร์เฟซการสื่อสารแบบอนุกรม Modicon Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตรวจสอบเฟิร์มแวร์:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าโมดูลหลัก Communication Gateway รุ่นเก่าได้รับการอัปเกรดโดยใช้ชุดอัปเกรดเฟิร์มแวร์ 126M4118-01 ก่อนติดตั้งโมดูล I\/O ใหม่ 136188-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการใส่แร็ค:\u003c\/strong\u003e ใส่บอร์ดหลักลงในช่องสื่อสารที่กำหนดของแร็ค 3500 โดยให้แน่ใจว่านั่งเต็มที่และขันสกรูตัวถังให้แน่น\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจัดตำแหน่งโมดูล I\/O:\u003c\/strong\u003e ติดตั้งโมดูล I\/O 136188-01 โดยตรงด้านหลังโมดูลหลักจากด้านหลังของแร็ค 3500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eข้อจำกัดของสายเคเบิล:\u003c\/strong\u003e ใช้สายอีเธอร์เน็ต 10BASE-T มาตรฐานพร้อมตัวเชื่อมต่อ RJ-45 สำหรับการตั้งค่าเครือข่าย โดยจำกัดความยาวสายตามมาตรฐาน IEEE 802.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการควบคุมสภาพแวดล้อม:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าสภาพแวดล้อมการทำงานไม่เกิน 65 องศาเซลเซียส และทางระบายอากาศบนตัวเครื่อง 3500 ไม่ถูกปิดกั้น  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus  \u003c\/li\u003e\n\u003cli\u003eATEX  \u003c\/li\u003e\n\u003cli\u003eIECEx  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย  \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eฟังก์ชันของโมดูล 3500\/92 คืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eทำหน้าที่เป็นเกตเวย์สื่อสาร ส่งออกข้อมูลจากแร็คป้องกันเครื่องจักร 3500 ไปยังระบบอัตโนมัติภายนอก เช่น PLC และ DCS  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูล I\/O 136188-01 มีอินเทอร์เฟซใดบ้าง?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eมีการเชื่อมต่ออีเธอร์เน็ต RJ-45 และอินเทอร์เฟซอนุกรม RS232  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโปรโตคอลใดบ้างที่สามารถใช้งานผ่านการเชื่อมต่ออีเธอร์เน็ตได้?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eรองรับโปรโตคอล Modbus\/TCP รวมถึงโปรโตคอลโฮสต์ Bently Nevada ที่เป็นกรรมสิทธิ์สำหรับแอปพลิเคชันซอฟต์แวร์  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้แตกต่างจากโมดูล 3500\/90 รุ่นเก่าอย่างไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eมันลบรีจิสเตอร์ Modbus ค่าหลักที่ตั้งไว้และแทนที่ด้วยยูทิลิตี้รีจิสเตอร์ Modbus ที่ปรับแต่งได้อย่างยืดหยุ่น  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลใช้เวลานานเท่าไรในการรีเฟรชข้อมูลจากแร็ค?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eอัตราการเก็บข้อมูลจะแตกต่างกันตามการตั้งค่าแต่รับประกันว่าจะไม่เกิน 1 วินาทีสำหรับทุกโมดูล  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการใช้พลังงานโดยทั่วไปของการตั้งค่า I\/O นี้คือเท่าใด?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eระบบโดยทั่วไปใช้พลังงาน 5.0 วัตต์เมื่อมีการติดตั้งโมดูล I\/O Modbus RS232  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฉันสามารถเชื่อมต่อซอฟต์แวร์ 3500 Configuration ผ่านเกตเวย์นี้ได้หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ มันอนุญาตให้สื่อสารผ่านอีเธอร์เน็ตกับซอฟต์แวร์ 3500 Rack Configuration และ Data Acquisition  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถ้าไฟ LED TX\/RX ดับ ควรตรวจสอบอะไรบ้าง?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตรวจสอบว่าโมดูลถูกติดตั้งอย่างถูกต้องและบัสการสื่อสารภายในแร็คทำงานและใช้งานได้หรือไม่  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการอัปเกรดเฟิร์มแวร์จำเป็นเมื่อเปลี่ยนเป็นอินเทอร์เฟซ 136188-01 ใหม่หรือไม่?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eโมดูลเกตเวย์หลักรุ่นเก่าต้องอัปเกรดเฟิร์มแวร์โดยใช้ชุด 126M4118-01 เพื่อให้สามารถรับรู้ฮาร์ดแวร์ I\/O ใหม่ได้อย่างถูกต้อง  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อจำกัดการเก็บรักษาในสภาพแวดล้อมสำหรับฮาร์ดแวร์นี้คืออะไร?  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eโมดูลต้องถูกเก็บไว้ในช่วงอุณหภูมิแวดล้อมระหว่าง -40 องศาเซลเซียส ถึง +85 องศาเซลเซียส  \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087"},{"product_id":"bently-nevada-3500-40m-125680-01-proximitor-i-o-module","title":"โมดูลอินพุต\/เอาต์พุต Bently Nevada 3500\/40M 125680-01 Proximitor","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-127\"\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e125680-01\u003c\/strong\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูล I\/O Proximitor 4 ช่องสัญญาณพร้อมการต่อสายภายใน ออกแบบมาสำหรับระบบป้องกันเครื่องจักรชุด 3500 Series.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eติดตั้งในช่องด้านหลังของแร็คเครื่องมือ 3500 โมดูลนี้ทำหน้าที่เป็นอินเทอร์เฟซฮาร์ดแวร์โดยตรงที่เชื่อมต่อทรานสดิวเซอร์โพร็กซิมิตีแบบกระแสไหลวนภายนอกกับโมดูล Proximitor Monitor 3500\/40M ด้านหน้า\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003eอุปกรณ์นี้ให้แรงกระตุ้นเซ็นเซอร์ที่เสถียร รับแรงดันอะนาล็อกดิบของการเคลื่อนที่ และส่งเส้นทางที่ผ่านการปรับสภาพเหล่านี้ไปยังการ์ดโปรเซสเซอร์หลักเพื่อคำนวณค่าต่างๆ ของเครื่องจักร เช่น การสั่นสะเทือนรัศมี ความเบี้ยวของเพลา ตำแหน่งแรงดัน การขยายตัวต่างกัน และ REBAM.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eด้วยบล็อกขั้วสกรูในตัว 125680-01 จึงไม่จำเป็นต้องใช้แผงต่อสายภายนอกแยกต่างหาก ช่วยประหยัดพื้นที่สำคัญภายในตู้ควบคุมที่มีความหนาแน่นสูง\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eการกำหนดค่าทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eหมายเลขรุ่น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M (ส่วนประกอบด้านหลัง)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน \/ รหัส\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125680-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเภทผลิตภัณฑ์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eโมดูล I\/O Proximitor (การต่อสายภายใน)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความเข้ากันได้ของระบบ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความจุช่องสัญญาณ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ช่องสัญญาณทรานสดิวเซอร์โพร็กซิมิตีที่ไม่แยกวงจร\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความต้านทานอินพุตสัญญาณ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kΩ สำหรับอินพุต Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการเชื่อมต่อการต่อสาย\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eบล็อกขั้วสกรูแบบหลายตำแหน่งในตัว\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการใช้พลังงานโดยทั่วไป 7.7 วัตต์\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการรองรับทรานสดิวเซอร์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 XL 8 มม., 11 มม. และ 25 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการวัด\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการวัดการสั่นสะเทือนรัศมี, แรงดัน, ความเบี้ยว, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eขนาด (กว้าง x สูง x ลึก)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.4 มม. x 241.3 มม. x 99.1 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eน้ำหนักสุทธิของผลิตภัณฑ์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 กก. (0.44 ปอนด์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเทศต้นทาง\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสหรัฐอเมริกา (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cp\u003eการดัดแปลงฮาร์ดแวร์ตรวจสอบเครื่องจักรหมุนเวียนกำหนดให้ต้องตรวจสอบหมายเลขอะไหล่สำรองอย่างชัดเจน จัดซื้ออะไหล่ทดแทนที่ตรงกับรหัสสั่งซื้อจากโรงงานด้านล่างเท่านั้น\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eคำต่อท้ายส่วนประกอบหลักของระบบ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eหมายเลขสั่งซื้อจากโรงงาน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125680-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eตัวแปรแกนหลักของโมดูล:\u003c\/strong\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003e\u003cspan\u003e \u003c\/span\u003eโมดูล I\/O ด้านหลังมาตรฐานแบบเต็มความสูง\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eบันทึกวิศวกรรม \u0026amp; คู่มือการเดินสายภาคสนาม\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eการจัดวางการต่อสายสัญญาณทรานสดิวเซอร์\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eบล็อกการต่อสายภายในของ 125680-01 รองรับเซ็นเซอร์โพร็กซิมิตีแบบแถวได้สูงสุดสี่ชุด แต่ละกลุ่มช่องสัญญาณประกอบด้วยขั้วสกรูเฉพาะสามตัว:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVTX \/ Prox (+):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eแรงดันไฟเลี้ยงของทรานสดิวเซอร์ (โดยปกติเป็นแรงกระตุ้น DC -24V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG \/ In (S):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eแรงดันไฟฟ้ากระแสตรงดิบแบบต่อเนื่องที่ส่งกลับจากเซ็นเซอร์ Proximitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM \/ Gnd (-):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eสายอ้างอิงกราวด์เครื่องมือทั่วไป\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eลอกฉนวนสายไฟออกให้ยาว 7 มม. ใช้สายเครื่องมือ 3 สายบิดเกลียวพร้อมชิลด์คุณภาพสูง (ทองแดงขนาด 18 AWG ถึง 22 AWG) เพื่อป้องกันการเหนี่ยวนำแม่เหล็กที่บิดเบือนสัญญาณความถี่สูง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eระเบียบการต่อสายกราวด์ชิลด์สายเคเบิล\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eต่อสายกราวด์ของชิลด์สายเคเบิลแต่ละเส้นที่โครงเครื่อง 3500 เพื่อป้องกันสัญญาณรบกวน EMI\/RFI สายชิลด์ต้องมัดรวมและยึดกับแถบกราวด์โครงเครื่องที่ไม่ทาสีโดยใช้แคลมป์กราวด์ที่มีพื้นผิวกว้าง\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eห้าม\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eผูกสายชิลด์เข้ากับสกรูขั้วสัญญาณคอมมอน (COM) ของบล็อกเทอร์มินัล เพราะจะทำให้เกิดวงจรกราวด์ซึ่งอาจปกปิดการสั่นสะเทือนที่มีความแรงสูงสำคัญ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อจำกัดความปลอดภัยในการเปลี่ยนแบบร้อน\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eสถาปัตยกรรม 3500 อนุญาตให้เปลี่ยนโมดูลแบบร้อนได้ อย่างไรก็ตาม การดึงโมดูล I\/O ด้านหลังทันทีจะตัดไฟจ่ายให้เซ็นเซอร์ภาคสนาม ทำให้เกิด \"ข้อผิดพลาดการตรวจสอบ\"\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eสลับสวิตช์ล็อกกุญแจด้านหน้าของชั้นวางไปที่\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eโหมด\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-124\"\u003eเปิดใช้งานช่องสัญญาณซอฟต์แวร์\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eธงข้าม\u003c\/strong\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003e\u003cspan\u003e \u003c\/span\u003eผ่านซอฟต์แวร์กำหนดค่าชั้นวาง 3500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eดำเนินการถอดออกทางกายภาพเพื่อป้องกันไม่ให้รีเลย์ฉุกเฉินด้านล่างทำงาน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eคำถามที่พบบ่อยเกี่ยวกับการบำรุงรักษาและแก้ไขปัญหา\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ความแตกต่างหลักระหว่างโมดูล 125680-01 กับโมดูลต่อสายภายนอกคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: โมดูล 125680-01 มีชุดขั้วสกรูในตัวที่แผ่นหลัง ทำให้สามารถเดินสายไฟภาคสนามต่อเข้ากับโมดูลโดยตรง ตัวเลือกการต่อสายภายนอกต้องใช้สายริบบิ้นหลายพินความหนาแน่นสูงเชื่อมต่อกับแผงขั้วต่อ DIN-rail แยกต่างหากที่ติดตั้งในตำแหน่งอื่น\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: โมดูล 125680-01 รับสัญญาณจากเซ็นเซอร์ระยะที่ไม่ใช่ Bently Nevada ได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ไม่ใช่ เส้นทางภายในและเมทริกซ์การปรับสเกลถูกปรับเทียบเฉพาะสำหรับเครื่องตรวจจับระยะ Bently Nevada โพรบจากผู้ผลิตรายอื่นจะทำให้ปัจจัยสเกลเชิงเส้นผิดเพี้ยน ส่งผลให้การแปลงการวัดไม่ถูกต้องและเกิดข้อผิดพลาดในการปรับเทียบ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: วิธีแก้ไขปัญหาช่องสัญญาณแต่ละช่องที่แสดงสถานะ \"NOT OK\" อย่างต่อเนื่องทำอย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: วัดแรงดันไฟฟ้ากระแสตรงดิบระหว่างขั้ว SIG และ COM ด้วยมัลติมิเตอร์ โพรบที่ทำงานปกติจะแสดงค่าแรงดันระหว่าง -4V DC ถึง -16V DC หากแรงดันใกล้ 0V หรือเท่ากับแรงดันจ่ายเต็ม -24V ความผิดปกติอาจเกิดจากสายเคเบิลลัดวงจรหรือสายเปิดในสนาม มากกว่าความล้มเหลวของโมดูล I\/O\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859290987,"sku":"125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125680-01-proximitor-i-o-module-nch0io30ar2_8104b65d-e1e6-431e-b4e2-7a9ec8d0e125.jpg?v=1765449252"},{"product_id":"bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","title":"โมดูลเทอร์มินัลอินพุต\/เอาต์พุตและเครื่องบันทึก Bently Nevada 81544-01 3300 Transducer","description":"\u003cp\u003e\u003cstrong\u003eโมดูลเทอร์มินัลอินพุต\/เอาต์พุตและเครื่องบันทึก 81544-01\u003c\/strong\u003e หรือหมายเลขอะไหล่โรงงานทางเลือก \u003cstrong\u003e78462-02\u003c\/strong\u003e เป็นส่วนประกอบอินเทอร์เฟซติดตั้งด้านหลังที่ออกแบบมาเฉพาะสำหรับ Bently Nevada 3300\/45 Dual Differential Expansion Monitor ภายในระบบเครื่องมือควบคุมการตรวจสอบกังหัน โมดูลนี้ช่วยให้สามารถส่งสัญญาณแบบสองช่องทางจากเซ็นเซอร์โพรบใกล้เคียงสองชุดแยกกัน เพื่อประเมินการเลื่อนแกนโรเตอร์ในแนวแกนสัมบูรณ์เทียบกับตัวเครื่องจักรที่เกิดจากการขยายตัวทางความร้อนในระหว่างการสตาร์ทและปิดเครื่อง โดยมีการตั้งค่าความต้านทานอินพุตคงที่ที่ 10 kΩ เพื่อรองรับตรรกะควบคุมของมอนิเตอร์ซึ่งประมวลผลทั้งขนาดและทิศทางของการขยายตัวต่างกันผ่านเกณฑ์แจ้งเตือนที่ตั้งโปรแกรมได้สี่ระดับ ประกอบด้วยจุดตั้งค่าการแจ้งเตือนเกินสองจุดและจุดตั้งค่าการแจ้งเตือนต่ำสองจุด สถาปัตยกรรมเทอร์มินัลแบบพาสซีฟนี้ทำงานโดยไม่มีรีเลย์อิเล็กโทรแมคคานิกส์บนบอร์ด ทำหน้าที่เป็นช่องทางส่งสัญญาณโดยตรงและศูนย์กระจายสัญญาณสำหรับเครื่องบันทึกเพื่อปกป้องเครื่องจักรอย่างต่อเนื่อง\u003c\/p\u003e\n\u003ch3\u003eสเปคฮาร์ดแวร์\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eสเปค\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81544-01 (78462-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eซีรีส์ผลิตภัณฑ์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eระบบ 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโมดูลมอนิเตอร์ที่เข้ากันได้\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45 Dual Differential Expansion Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eจำนวนช่องสัญญาณ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ช่องสัญญาณอิสระ (ช่อง B สามารถปิดได้)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการเชื่อมต่อกับทรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณจากโพรบใกล้เคียง 2 ตัว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานอินพุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรองรับความจุแจ้งเตือน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eรวม 4 จุดตั้งค่า (แจ้งเตือนเกิน 2 จุด, แจ้งเตือนต่ำ 2 จุด)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการตั้งค่ารีเลย์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไม่มีรีเลย์บนบอร์ด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเทศผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eบันทึกทางวิศวกรรม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eความต้านทานอินพุต 10 kΩ ถูกปรับให้เหมาะสมเพื่อให้ตรงกับพารามิเตอร์เอาต์พุตของเซ็นเซอร์ Bently Nevada Proximitor มาตรฐาน เพื่อให้มั่นใจว่าไม่มีการเสื่อมสัญญาณในช่วงการวัดการขยายตัวต่างกัน\u003c\/li\u003e\n\u003cli\u003eเมื่อจำเป็นต้องวัดแกนเดียวบนตัวเครื่องจักรขนาดเล็ก ช่อง B ต้องถูกปิดโปรแกรมในมอนิเตอร์ 3300\/45 เพื่อป้องกันข้อผิดพลาดแรงดันไฟฟ้าช่องว่างแบบวงจรเปิด\u003c\/li\u003e\n\u003cli\u003eเนื่องจาก 81544-01 ไม่มีรีเลย์กลไก คำสั่งล็อกและการทำงานของสัญญาณเตือนทั้งหมดต้องถูกประมวลผลผ่านระบบแบ็คเพลนไปยังโมดูลรีเลย์ระบบ 3300 ที่อยู่ติดกัน\u003c\/li\u003e\n\u003cli\u003eการเปลี่ยนแปลงการขยายตัวทางความร้อนในระหว่างการเร่งความเร็วของกังหันจะเปลี่ยนแรงดันไฟฟ้าช่องว่างพื้นฐาน เอาต์พุตดิบจากเครื่องบันทึกของเทอร์มินัลนี้จะทำแผนที่การเปลี่ยนแปลงแรงดันไฟฟ้ากระแสตรงสัดส่วนเหล่านี้เพื่อใช้ในการวิเคราะห์แนวโน้ม\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eแนวทางปฏิบัติในสนาม\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eติดตั้งสายดินชิลด์อย่างเข้มงวดที่แถบเทอร์มินัลที่กำหนด โดยให้สายดินชิลด์ด้านนอกของสายต่อขยายโพรบใกล้เคียงเชื่อมต่อกับกราวด์เครื่องมือในขณะที่แยกออกจากตัวเซ็นเซอร์\u003c\/li\u003e\n\u003cli\u003eแยกเส้นทางเดินสายสำหรับอินพุตเซ็นเซอร์ความต้านทานต่ำและวงจรควบคุมแรงดันไฟฟ้าสลับสูงที่อยู่ใกล้เคียง เพื่อป้องกันการรบกวนสัญญาณภายในตู้ TSI\u003c\/li\u003e\n\u003cli\u003eก่อนการใช้งาน ตรวจสอบให้แน่ใจว่าสกรูล็อกเทอร์มินัลถูกขันตามมาตรฐานแรงบิด เพื่อป้องกันการเปลี่ยนแปลงแรงดันไฟฟ้าช่องว่างที่เกิดจากความต้านทานการสัมผัสทางกายภาพ\u003c\/li\u003e\n\u003cli\u003eจัดระยะห่างและการจัดแนวทางกลอย่างเหมาะสมเมื่อสไลด์บล็อกเทอร์มินัล 81544-01 เข้ากับตัวเชื่อมต่อแร็คด้านหลัง เพื่อป้องกันการบิดงอของพินหรือวงจรเปิดบนแบ็คเพลน 3300\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อยทางเทคนิคและการจัดซื้อ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: โมดูลบล็อกเทอร์มินัล 81544-01 มีรีเลย์กลไกสำหรับขับโซลินอยด์ทริปในพื้นที่หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ไม่มี 81544-01 เป็นโมดูลแบบไม่มีรีเลย์ มันส่งสัญญาณดิบจากทรานสดิวเซอร์และเครื่องบันทึก โดยอาศัยแบ็คเพลน 3300 ในการส่งสถานะสัญญาณเตือนไปยังโมดูลรีเลย์เฉพาะ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ส่วนประกอบนี้สามารถใช้กับมอนิเตอร์โพรบใกล้เคียงซีรีส์ 3300 ทั่วไป เช่น โมดูลวัดการสั่นสะเทือนรัศมี ได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: ไม่ได้ หมายเลขชิ้นส่วนนี้ถูกแมปโดยตรงกับพารามิเตอร์ฮาร์ดแวร์ของ 3300\/45 Dual Differential Expansion Monitor และไม่สามารถใช้แทนที่ในช่องมอนิเตอร์อื่นได้\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ฟังก์ชันทางเทคนิคของหมายเลขอะไหล่ทางเลือก 78462-02 ที่ระบุในชุดประกอบคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eตอบ: หมายเลข 78462-02 แทนบอร์ดเปล่าหรือชุดย่อยที่ใช้ในกระบวนการผลิต ซึ่งตรงกับหมายเลขชิ้นส่วนระดับบนสุด 81544-01 อย่างสมบูรณ์\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860306795,"sku":"81544-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81544-01-xducr-i-o-and-record-terminals-phquym4p1wm_e2995e0f-7667-420e-acd8-3471ac8b1dcc.jpg?v=1765449280"},{"product_id":"bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"โมดูลอินพุต\/เอาต์พุตแบบไม่แยก Bently Nevada 133827-01 3500\/60 RTD\/TC","description":"\u003ch3\u003eข้อมูลเชิงลึกของผลิตภัณฑ์หลัก\u003c\/h3\u003e\n\u003cp\u003eBently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(133827-01) ทำหน้าที่เป็นโมดูล I\/O แบบไม่แยกวงจร RTD\/TC \u003cstrong\u003e3500\/60\u003c\/strong\u003e ที่มีความน่าเชื่อถือสูง ออกแบบมาสำหรับการต่อสายภายนอก โมดูลนี้เชื่อมต่อโดยตรงกับบล็อกเทอร์มินัลภายนอกเพื่อประมวลผลสัญญาณอุณหภูมิที่สำคัญจากเครื่องตรวจจับอุณหภูมิแบบความต้านทาน (RTDs) และเทอร์โมคัปเปิล (TCs) ในอุตสาหกรรมหนัก เช่น การกลั่นปิโตรเคมี การแปรรูป LNG และการผลิตไฟฟ้า ความผิดปกติทางความร้อนบ่งชี้ถึงความล้มเหลวของเครื่องจักรที่กำลังจะเกิดขึ้น โดยการส่งมอบการตรวจสอบอุณหภูมิที่ต่อเนื่องและมีความแม่นยำสูงให้กับระบบป้องกันเครื่องจักร \u003cstrong\u003e3500\u003c\/strong\u003e ส่วนประกอบนี้ช่วยป้องกันความล้มเหลวร้ายแรง ขจัดการหยุดทำงานที่ผิดพลาด และลดเวลาหยุดทำงานในอุตสาหกรรมที่ไม่ได้วางแผนไว้ได้อย่างมาก\u003c\/p\u003e\n\u003ch3\u003eสถาปัตยกรรมฮาร์ดแวร์และตัวเลือกอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cp\u003eฮาร์ดแวร์ \u003cstrong\u003e133827-01\u003c\/strong\u003e ถูกออกแบบมาเพื่อการประมวลผลสัญญาณความหนาแน่นสูงภายในแผงหลังของแร็ค \u003cstrong\u003e3500\u003c\/strong\u003e ทำหน้าที่เป็นลิงก์ทางกายภาพระหว่างเซ็นเซอร์วัดอุณหภูมิที่ติดตั้งในสนามกับการ์ดมอนิเตอร์หลัก \u003cstrong\u003e3500\/60\u003c\/strong\u003e สถาปัตยกรรมการต่อสายภายนอกช่วยให้นักวิศวกรสามารถเดินสายฟิลด์ไปยังบล็อกเทอร์มินัลแยกต่างหากที่อยู่นอกตู้แร็คหลัก การตั้งค่านี้ช่วยให้การเดินสายในตู้ที่มีความหนาแน่นสูงง่ายขึ้น อำนวยความสะดวกในการบำรุงรักษาอย่างรวดเร็ว และปรับปรุงการจัดการสายเคเบิล การออกแบบวงจรแบบไม่แยกวงจรขึ้นอยู่กับการต่อกราวด์ระบบอย่างถูกต้องและการป้องกันภายนอกคุณภาพสูงเพื่อรักษาความสมบูรณ์ของสัญญาณในระยะทางไกลของเซ็นเซอร์ในอุตสาหกรรม\u003c\/p\u003e\n\u003ch3\u003eพารามิเตอร์ข้อมูลสำคัญ\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eรายละเอียดสเปค\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eระบบป้องกันเครื่องจักร \u003cstrong\u003e3500\u003c\/strong\u003e ซีรีส์\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจร\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรูปแบบการต่อสาย\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eการต่อสายภายนอก\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eประเทศที่ผลิต\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eสหรัฐอเมริกา\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 กก.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eขนาด\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 มม. x 23 มม. x 112 มม.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 ถึง +65 องศาเซลเซียส\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 ถึง +85 องศาเซลเซียส\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 วัตต์ ปกติ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรองรับอินพุตเซ็นเซอร์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD แพลทินัม, RTD ทองแดง, RTD นิกเกิล, เทอร์โมคัปเปิลประเภท E\/J\/K\/T\/S\/R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eคำถามที่พบบ่อยทางเทคนิค\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูล 133827-01 จัดการกับสัญญาณรบกวนอย่างไรในขณะที่ออกแบบแบบไม่แยกวงจร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eโมดูลนี้พึ่งพาสายเคเบิลบิดเกลียวที่มีการป้องกันคุณภาพสูงภายนอกและระบบกราวด์อุตสาหกรรมแบบจุดเดียว วิศวกรต้องมั่นใจว่าการต่อสายป้องกันที่บล็อกภายนอกถูกต้องเพื่อบรรเทาการรบกวนสัญญาณโหมดทั่วไป\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eข้อได้เปรียบหลักของการเลือกการต่อสายภายนอกแทนการต่อสายภายในคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการต่อสายภายนอกช่วยให้เจ้าหน้าที่บำรุงรักษาสามารถเปลี่ยนโมดูล I\/O ได้โดยไม่ต้องถอดสายฟิลด์ใดๆ การจัดวางนี้ช่วยลดข้อผิดพลาดในการเดินสายของมนุษย์อย่างมากในระหว่างกระบวนการเปลี่ยนในสนาม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้สามารถใช้สัญญาณ RTD และเทอร์โมคัปเปิลบนการ์ดเดียวกันพร้อมกันได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eได้ ซอฟต์แวร์มอนิเตอร์ \u003cstrong\u003e3500\/60\u003c\/strong\u003e อนุญาตให้ตั้งค่าช่องสัญญาณแยกกัน คุณสามารถโปรแกรมช่องสัญญาณเฉพาะสำหรับ RTD และช่องอื่นๆ สำหรับเทอร์โมคัปเปิลบนอินเทอร์เฟซ \u003cstrong\u003e133827-01\u003c\/strong\u003e เดียวกัน\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eคู่มือการติดตั้งภาคสนามและวิศวกรรมการเดินสาย\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโปรโตคอลการป้องกัน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eต่อสายป้องกันของสายเซ็นเซอร์ทั้งหมดที่บล็อกเทอร์มินัลภายนอกอย่างเคร่งครัด ห้ามต่อสายป้องกันที่ปลายเซ็นเซอร์ในสนาม เพื่อป้องกันวงจรกราวด์ที่เป็นอันตรายซึ่งอาจทำให้สัญญาณไมโครโวลต์ของเทอร์โมคัปเปิลเสียหาย\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eแรงบิดในการขัน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเมื่อยึดโมดูล I\/O กับรางหลังของแชสซี \u003cstrong\u003e3500\u003c\/strong\u003e ให้ขันสกรูยึดแชสซีด้วยแรงบิดที่แน่นอน \u003cstrong\u003e0.5 N m\u003c\/strong\u003e เพื่อป้องกันความเครียดที่ตัวเชื่อมต่อแผงหลัง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eแนวทางการเดินสายความร้อน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eตรวจสอบให้แน่ใจว่าสายเคเบิลต่อสายภายนอกถูกเดินสายห่างจากสายมอเตอร์ AC แรงดันสูงหรือไดรฟ์ความถี่แปรผัน (VFD) เพื่อปกป้องวงจรแบบไม่แยกวงจรจากการรบกวนทางแม่เหล็กไฟฟ้า\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861289835,"sku":"133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133827-01-pc-board-plc-add-on-board-taordovzb0n_6f56e6e5-a692-4318-9449-b1d0067d7924.jpg?v=1765449309"},{"product_id":"bently-nevada-135489-04-3500-40m-proximitor-i-o-module-with-internal-barriers","title":"โมดูลอินพุต\/เอาต์พุต Bently Nevada 135489-04 3500\/40M Proximitor พร้อมอุปสรรคภายใน","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e (135489-04) เป็นโมดูลอินพุต\/เอาต์พุตประสิทธิภาพสูงที่ออกแบบมาเฉพาะสำหรับระบบตรวจสอบ Bently Nevada \u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor โมดูลอินเทอร์เฟซสี่ช่องนี้ถูกออกแบบมาเพื่อเชื่อมต่อทรานสดิวเซอร์ภาคสนามกับแร็คปกป้องเครื่องจักร โดยมี \u003cstrong\u003eอุปสรรคภายใน\u003c\/strong\u003e และ \u003cstrong\u003eการสิ้นสุดภายใน\u003c\/strong\u003e รวมอยู่ด้วย การกำหนดค่านี้มีความสำคัญสำหรับการติดตั้งในพื้นที่อันตราย เนื่องจากอุปสรรคความปลอดภัยในตัวจำกัดพลังงานไฟฟ้าเพื่อป้องกันการจุดระเบิดในบรรยากาศที่ระเบิดได้\u003c\/p\u003e\n\u003cp\u003eโมดูลประมวลผลสัญญาณพัลส์และการเคลื่อนที่จากทรานสดิวเซอร์ระยะใกล้เพื่อตรวจสอบพารามิเตอร์เครื่องจักรสำคัญ รวมถึงการสั่นสะเทือนรัศมี ตำแหน่งแรงดัน ความเบี้ยว การขยายตัวต่างกัน และ REBAM โดยให้การปกป้องเครื่องจักรอย่างต่อเนื่องและข้อมูลความละเอียดสูงแก่เจ้าหน้าที่ปฏิบัติการ \u003cstrong\u003e135489-04\u003c\/strong\u003e ทำหน้าที่เป็นส่วนสำคัญในการลดเวลาหยุดทำงานโดยไม่คาดคิดสำหรับสินทรัพย์ที่สำคัญในอุตสาหกรรมผลิตไฟฟ้า น้ำมันและก๊าซ และการแปรรูปปิโตรเคมี\u003c\/p\u003e\n\u003ch3\u003eสถาปัตยกรรมฮาร์ดแวร์ \u0026amp; การประมวลผลสัญญาณ\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e โมดูลนี้ออกแบบด้วยสถาปัตยกรรมความหนาแน่นสูงที่รองรับสัญญาณทรานสดิวเซอร์ระยะใกล้ได้สูงสุดสี่ช่องพร้อมกัน มีการแยกกัลวานิกและส่วนประกอบความปลอดภัยภายในที่เป็นไปตามพารามิเตอร์เอนทิตี CSA-NRTL\/C และ ATEX\/IECEx\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตั้งโปรแกรมช่องสัญญาณ\u003c\/strong\u003e: ช่องตรวจสอบถูกตั้งโปรแกรมเป็นคู่ ทำให้ระบบสามารถทำงานได้สูงสุดสองฟังก์ชันพร้อมกัน (เช่น ช่อง 1 และ 2 ตรวจสอบการสั่นสะเทือนรัศมี ขณะที่ช่อง 3 และ 4 ตรวจสอบตำแหน่งแรงดัน)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eอุปสรรคความปลอดภัย\u003c\/strong\u003e: โมดูลประกอบด้วยวงจร Proximitor Barrier พร้อมพารามิเตอร์พลังงาน (PWR) และสัญญาณ (SIG) เฉพาะ เพื่อให้ระดับ Vmax และ Imax อยู่ในขอบเขตที่ปลอดภัยสำหรับความปลอดภัยภายใน\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับสัญญาณ\u003c\/strong\u003e: ฮาร์ดแวร์มีความสามารถในการกรองขั้นสูง รวมถึงตัวกรองตรง (สูงสุด 4000 Hz) ตัวกรองช่องว่าง และตัวกรองโน๊ตคงที่ Q สำหรับการติดตามเวกเตอร์ 1X และ 2X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียดสเปค\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eซีรีส์ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O Proximitor พร้อมอุปสรรคภายใน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eสัญญาณขาเข้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ถึง 4 ทรานสดิวเซอร์ระยะใกล้\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 วัตต์ ปกติ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอิมพีแดนซ์ขาเข้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 กิโลโอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eพลังงานทรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 163.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 กก. (1.01 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแหล่งกำเนิด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eคำถามทางเทคนิคที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eอุปสรรคภายในมีผลต่อข้อกำหนดการเดินสายฟิลด์อย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e รวมอุปสรรคความปลอดภัยในตัว ซึ่งช่วยขจัดความจำเป็นในการใช้แบริเออร์เซเนอร์ภายนอกหรืออุปกรณ์แยกกัลวานิกระหว่างแร็คกับพื้นที่อันตราย ช่วยให้การจัดวางตู้ควบคุมง่ายขึ้นและลดอิมพีแดนซ์ของวงจรรวม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้สามารถใช้ได้ทั้งสำหรับการสั่นสะเทือนรัศมีและตำแหน่งแรงดันหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ ตัวตรวจสอบ 3500\/40M ที่จับคู่กับโมดูล I\/O นี้ช่วยให้สามารถตั้งค่าช่องสัญญาณเป็นคู่สำหรับฟังก์ชันต่างๆ เช่น การสั่นสะเทือนรัศมีในคู่หนึ่งและตำแหน่งแรงดันในอีกคู่หนึ่ง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eพารามิเตอร์เอนทิตีหลักสำหรับอุปสรรคภายในคืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eสำหรับ Proximitor Barrier (PWR) ค่า Vmax คือ 26.25 V และ Imax คือ 110.48 mA สำหรับสัญญาณ (SIG) ค่า Vmax คือ 13.65 V และ Imax คือ 2.74 mA\u003c\/p\u003e\n\u003ch3\u003e🛠️ คู่มือการติดตั้งและขั้นตอนสำคัญ\u003c\/h3\u003e\n\u003cp\u003e135489-04 เป็นโมดูล I\/O ที่มี \u003cspan\u003eอุปสรรคภายใน\u003c\/span\u003e และ \u003cspan\u003eการต่อสายภายใน\u003c\/span\u003e ติดตั้งที่ด้านหลังของแร็ค 3500 โดยตรงหลัง \u003cspan\u003eมอนิเตอร์ Proximitor 3500\/40M\u003c\/span\u003e ให้การแยกปลอดภัยโดยเนื้อแท้ (IS) สำหรับทรานสดิวเซอร์ที่ตั้งอยู่ในพื้นที่อันตราย\u003c\/p\u003e\n\u003ch4\u003e1. การติดตั้งฮาร์ดแวร์\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eช่องบายพาส:\u003c\/span\u003e ก่อนใส่โมดูล ให้ตั้งช่องมอนิเตอร์ที่เกี่ยวข้องในโหมด \u003cspan\u003eบายพาส\u003c\/span\u003e เพื่อป้องกันการหยุดเครื่องจักรโดยไม่ตั้งใจ\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eการจัดช่องเสียบ:\u003c\/span\u003e ใส่โมดูล I\/O ลงในช่องเต็มความสูงที่ด้านหลังแร็คซึ่งตรงกับโมดูลมอนิเตอร์ 3500\/40M ที่ด้านหน้าอย่างแม่นยำ\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eการติดตั้งและยึด:\u003c\/span\u003e นำทางโมดูลตามรางของโครงเครื่องจนเชื่อมต่อแน่นกับตัวเชื่อมต่อหลังแผง ยึดสกรูหัวแม่มือสองตัวที่แผงด้านหน้าให้แน่น\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eการกราวด์ IS:\u003c\/span\u003e แร็ค 3500 \u003cspan\u003eต้องมีโมดูลกราวด์ 3500\/04 IS\u003c\/span\u003e ตรวจสอบให้แน่ใจว่านิ้วกราวด์ที่ด้านหลังของโมดูล I\/O สัมผัสแน่นกับบัสบาร์กราวด์ IS ของแร็ค\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. การเดินสายและการแยกทางกายภาพ\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eขั้วต่อสี:\u003c\/span\u003e ต่อสายไฟฟ้าทรานสดิวเซอร์ในพื้นที่อันตรายเข้ากับขั้วต่อสี \u003cspan\u003eน้ำเงิน\u003c\/span\u003e ต่อสัญญาณเอาต์พุตในพื้นที่ปลอดภัยเข้ากับขั้วต่อสี \u003cspan\u003eเขียว\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eระยะห่าง 50 มม. (2 นิ้ว):\u003c\/span\u003e รักษาระยะห่างทางกายภาพอย่างน้อย \u003cspan\u003e50 มม. (2 นิ้ว)\u003c\/span\u003e ระหว่างสายไฟในพื้นที่อันตราย (ปลอดภัยโดยเนื้อแท้) กับสายไฟในพื้นที่ปลอดภัย\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eเส้นทางเดินสาย:\u003c\/span\u003e เดินสายในพื้นที่อันตรายขึ้นไปยังรางสายด้านบน และเดินสายในพื้นที่ปลอดภัยลงไปยังรางสายด้านล่างเพื่อป้องกันการปนเปื้อนของสัญญาณ\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e🛒 หมายเหตุการจัดซื้อ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eไม่มีทรานสดิวเซอร์แบบบัส:\u003c\/strong\u003e โมดูล I\/O อุปสรรคภายใน \u003cspan\u003eไม่รองรับ\u003c\/span\u003e ทรานสดิวเซอร์แบบบัส (สายไฟจ่ายร่วม) ทรานสดิวเซอร์แต่ละตัวต้องเดินสายแยกกัน\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eข้อกำหนดความลึกของตู้: \u003c\/strong\u003eโมดูลอุปสรรคภายในมีความลึกมากกว่าโมดูล I\/O มาตรฐาน \u003cspan\u003eไม่สามารถใส่ในตู้ที่มีความลึก 400 มม. ได้\u003c\/span\u003e ต้องใช้ความลึกตู้ขั้นต่ำ \u003cspan\u003e600 มม.\u003c\/span\u003e หรือใช้ตู้แบบติดตั้งบนบัลค์เฮด\/แผง\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eการลดจำนวนช่องเสียบ:\u003c\/strong\u003e การติดตั้งโมดูลกราวด์ 3500\/04 IS ที่จำเป็นจะใช้ช่อง I\/O เฉพาะหนึ่งช่อง ซึ่งทำให้จำนวนช่องมอนิเตอร์สูงสุดในแร็คมาตรฐานขนาด 19 นิ้วลดลง \u003cspan\u003eจาก 14 เหลือ 13\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eการต่อสายภายในเท่านั้น: \u003c\/strong\u003eรุ่นเฉพาะนี้ (-04) มีขั้วต่อสกรูภายใน \u003cspan\u003eไม่สามารถใช้\u003c\/span\u003e ร่วมกับบล็อกต่อสายภายนอก (ETBs) หรือสายไฟที่ผลิตสำเร็จรูปได้\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eข้อจำกัดอุณหภูมิ: \u003c\/strong\u003eแร็คที่ติดตั้งอุปสรรคภายในมีช่วงอุณหภูมิการทำงานที่แคบกว่า คือ \u003cspan\u003e0°C ถึง +65°C\u003c\/span\u003e (32°F ถึง +150°F) เมื่อเทียบกับขีดจำกัดล่างมาตรฐานที่ -30°C โปรดตรวจสอบการระบายอากาศของตู้ให้เหมาะสม\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863583595,"sku":"135489-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-04-i-o-module-with-internal-barriers-and-internal-terminations-pfud1qtzn2t_898c93e6-a81e-4c17-af39-a2ae95a5f4a2.jpg?v=1765449377"},{"product_id":"bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module","title":"เบนท์ลีย์ เนวาด้า 3500\/20-02-01-00 135031-01 โมดูลอินเทอร์เฟซ I\/O แร็ค","description":"\u003ch3\u003eคำอธิบาย  \u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/20-02-01-00 135031-01\u003c\/strong\u003e เป็นส่วนประกอบอินเทอร์เฟซด้านหลังเฉพาะที่ทำหน้าที่เป็นศูนย์กลางอินพุต\/เอาต์พุตสำคัญสำหรับ \u003cstrong\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/strong\u003e การรวมฮาร์ดแวร์นี้จับคู่โครงสร้างโมดูลอินเทอร์เฟซแร็ค \u003cstrong\u003e3500\/20\u003c\/strong\u003e กับบอร์ดอินเทอร์เฟซแผงหลัง \u003cstrong\u003e135031-01\u003c\/strong\u003e ซึ่งมีพอร์ตสื่อสารอนุกรม RS422\/RS485 คู่และพอร์ตกำหนดค่า RS232 เฉพาะ ชุดประกอบนี้ประมวลผลโปรโตคอลการกำหนดค่าเฉพาะและข้อมูลสถานะเครื่องจักร ช่วยให้เชื่อมต่อโดยตรงระหว่างแร็คตรวจสอบ ซอฟต์แวร์กำหนดค่า และเครือข่ายควบคุมโฮสต์โรงงาน นอกจากการสื่อสารแบบอนุกรมดิจิทัลแล้ว ฮาร์ดแวร์ยังรวม \u003cstrong\u003eระบบติดต่อ\u003c\/strong\u003e ในตัว รวมถึงสายฮาร์ดแวร์เฉพาะสำหรับรีเซ็ตแร็คระยะไกลและการกำหนดค่ารีเลย์ \u003cstrong\u003eNot-OK\u003c\/strong\u003e เพื่อส่งผ่านข้อผิดพลาดสถานะระบบไปยังระบบอัตโนมัติการควบคุมโดยตรงโดยไม่รบกวนเส้นทางการตรวจสอบป้องกันเครื่องจักรที่สำคัญ.\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eชุดประกอบการสื่อสารแบบบูรณาการครบชุดที่รวม   \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e การกำหนดค่าการสั่งซื้อและ   \u003cstrong\u003e135031-01\u003c\/strong\u003e บอร์ดอินเทอร์เฟซอนุกรม  \u003c\/li\u003e\n\u003cli\u003eพอร์ตอนุกรมคู่ที่แยกอิสระ ปรับแต่งได้สำหรับโปรโตคอลการสื่อสาร RS422 หรือ RS485 ผ่านการเลือกฮาร์ดแวร์บนแผงหลัง  \u003c\/li\u003e\n\u003cli\u003eการเชื่อมต่อ RS232 เฉพาะด้านหน้าและด้านหลังที่ปรับแต่งสำหรับการวินิจฉัยภาคสนามและเครื่องมือกำหนดค่าแร็ค  \u003c\/li\u003e\n\u003cli\u003eฮาร์ดแวร์ \u003cstrong\u003eระบบติดต่อ\u003c\/strong\u003e เฉพาะบนบอร์ดที่รองรับคำสั่งรีเซ็ตแร็คระยะไกลและกลไกล็อกการกำหนดค่าภายนอก  \u003c\/li\u003e\n\u003cli\u003eรีเลย์ \u003cstrong\u003eNot-OK\u003c\/strong\u003e ในตัวที่ให้การตัดต่อฮาร์ดแวร์อัตโนมัติหากตรวจพบข้อผิดพลาดในช่องตรวจสอบใดๆ  \u003c\/li\u003e\n\u003cli\u003eสถาปัตยกรรมการสื่อสารที่ไม่รบกวนเพื่อให้แน่ใจว่าการดึงข้อมูลและการกำหนดค่าไม่ส่งผลกระทบต่อเส้นทางการป้องกันเครื่องจักรพื้นฐาน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการเชื่อมต่อแบบอนุกรม Modbus หรือแบบเฉพาะสำหรับเชื่อมต่อแร็คตรวจจับการสั่นสะเทือนกับ PLC อุตสาหกรรมและระบบควบคุมแบบกระจาย (\u003cstrong\u003eDCS\u003c\/strong\u003e)  \u003c\/li\u003e\n\u003cli\u003eการติดตามทรัพย์สินเครื่องจักรโรงงานระยะไกลและการจัดการการกำหนดค่าหลายแร็คแบบรวมศูนย์  \u003c\/li\u003e\n\u003cli\u003eรวมการแจ้งเตือนข้อผิดพลาดระดับฮาร์ดแวร์ของแร็คเข้ากับวงจรล็อกความปลอดภัยผ่านรีเลย์ติดต่อระบบ  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสสั่งซื้อ \/ หมายเลขชิ้นส่วน  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบาย  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-AXX-BXX-CXX  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eเมทริกซ์การสั่งซื้อโมดูลอินเทอร์เฟซแร็คครบชุด  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลอินเทอร์เฟซแร็ค I\/O พร้อมการสิ้นสุดภายใน RS422\/RS485  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการสื่อสาร: การสื่อสารแบบอนุกรม RS232\/RS422\/RS485  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน: ไม่มี  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eส่วนประกอบบอร์ด I\/O:\u003c\/strong\u003e โมดูลอินเทอร์เฟซแร็ค I\/O พร้อมการสิ้นสุดภายใน RS422\/RS485  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125744-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eส่วนประกอบหลัก:\u003c\/strong\u003e โมดูลอินเทอร์เฟซแร็ค (บัตรด้านหน้า)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค  \u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่พารามิเตอร์  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียดข้อกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการกำหนดรวม  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทโมดูล  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลอินเทอร์เฟซแร็ค I\/O พร้อมการสื่อสารแบบอนุกรม  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการใช้พลังงาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eใช้พลังงานโดยทั่วไป 4.3 วัตต์  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการสื่อสารแบบอนุกรม  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 และ RS485 (โปรโตคอลเลือกได้ด้วยสวิตช์)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอินเทอร์เฟซการกำหนดค่า  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโปรโตคอล RS232 ผ่านตัวเชื่อมต่อ D-sub 9 พิน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขารีเลย์ Not-OK  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 Vdc หรือ 120 Vac, ออกแบบ SPDT เคลือบอีพ็อกซี่  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขาอินพุตระบบ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eรีเซ็ตแร็ค, การล็อกการกำหนดค่า และทริปมัลติเพิล  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส (-22 องศาฟาเรนไฮต์ ถึง +150 องศาฟาเรนไฮต์)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความชื้นสัมพัทธ์  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 95% ไม่ควบแน่น  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดบัตรหลัก  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 241.8 มม. (9.50 นิ้ว x 0.96 นิ้ว x 9.52 นิ้ว)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดบัตร I\/O  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 99.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 3.90 นิ้ว)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโมดูลหลัก  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 กก. (2.0 ปอนด์)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโมดูล I\/O  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 กก. (1.0 ปอนด์)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ  \u003c\/h3\u003e\n\u003cp\u003eอินเทอร์เฟซเทอร์มินัลและตัวบ่งชี้ภาพบน   \u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e เลย์เอาต์ให้สัญญาณเฉพาะและการติดตามการเชื่อมต่อ:  \u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพอร์ต \/ เทอร์มินัลบล็อก  \u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน \/ การกำหนด  \u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED OK  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวบ่งชี้แผงด้านหน้า; สว่างสีเขียวค้างเมื่ออินเทอร์เฟซประมวลผลงานซอฟต์แวร์โดยไม่มีข้อผิดพลาดภายใน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED TX\/RX  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวบ่งชี้แผงด้านหน้า; กระพริบเพื่อแสดงการส่งข้อมูลดิจิทัลที่ใช้งานผ่านบัสแบ็คเพลน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eพอร์ต CONFIG  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eพอร์ต RS232 9 พินด้านหน้าเฉพาะสำหรับเชื่อมต่อกับพีซีภาคสนามที่รันซอฟต์แวร์กำหนดค่า  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eพอร์ตโฮสต์  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eด้านหลัง   \u003cstrong\u003e135031-01\u003c\/strong\u003e การเชื่อมต่อ RS232 9 พิน ใช้สำหรับอินเทอร์เฟซการดึงข้อมูลโฮสต์  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRACK RS422 \/ RS485  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eบล็อกสกรูสิ้นสุดภายในสำหรับการเดินสายเครือข่ายอนุกรมระยะไกลไปยังห้องควบคุมโรงงาน  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCONTACTS ระบบ  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขาเทอร์มินัลบล็อกด้านหลังสำหรับกำหนดสายรีเซ็ตแร็ค การล็อกการกำหนดค่า และเอาต์พุตรีเลย์ Not-OK  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง  \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจัดสรรสล็อต:\u003c\/strong\u003e ติดตั้งบัตรด้านหน้าคู่หูเฉพาะในสล็อต 1 ของโครงเครื่อง ซึ่งอยู่ติดกับช่องจ่ายไฟโดยตรง และติดตั้งโมดูลอินเทอร์เฟซ \u003cstrong\u003e135031-01\u003c\/strong\u003e ในตำแหน่งสล็อตด้านหลังที่สอดคล้องกัน  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเลือกโปรโตคอล:\u003c\/strong\u003e ตั้งสวิตช์การสิ้นสุดฮาร์ดแวร์ภายในบนบัตรวงจร \u003cstrong\u003e135031-01\u003c\/strong\u003e ให้ตรงกับพารามิเตอร์เครือข่ายการส่งข้อมูลแบบสมดุล RS422 หรือ RS485 ของโรงงานที่กำหนดอย่างถูกต้อง  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการสิ้นสุดเครือข่าย:\u003c\/strong\u003e สำหรับการติดตั้งปลายสายบนบัสอนุกรมแบบหลายจุดระยะไกล ให้เปิดใช้งานตัวต้านทานสิ้นสุดสายในบอร์ดเพื่อป้องกันการสะท้อนสัญญาณและการสูญหายของข้อมูล\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเดินสายความปลอดภัย:\u003c\/strong\u003e เชื่อมต่อกุญแจสวิตช์ภายนอกทางกายภาพกับขั้วล็อกการตั้งค่าบนบล็อกเทอร์มินัลด้านหลังเพื่อปกป้องการตั้งค่าตู้แร็คจากการเปลี่ยนแปลงซอฟต์แวร์ที่ไม่ได้รับอนุญาตหรือโดยไม่ตั้งใจ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eโปรโตคอลการต่อสายดิน:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าชิลด์สายข้อมูลอนุกรมถูกต่อสายอย่างแน่นหนาที่บล็อกกราวด์ของตู้เพื่อป้องกันการรบกวนแม่เหล็กไฟฟ้าที่อาจบิดเบือนการสื่อสารความเร็วสูง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eคำสั่ง EMC:\u003c\/strong\u003e คำสั่งชุมชนยุโรป 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eมาตรฐาน EMC:\u003c\/strong\u003e EN 61000-6-2 (ภูมิคุ้มกันอุตสาหกรรม), EN 61000-6-4 (การปล่อยอุตสาหกรรม)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eความปลอดภัยทางไฟฟ้า:\u003c\/strong\u003e คำสั่งแรงดันต่ำ 2014\/35\/EU, มาตรฐาน EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eคำสั่ง RoHS:\u003c\/strong\u003e 2011\/65\/EU การปฏิบัติตามมาตรฐานยุโรป\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรับรองอเมริกาเหนือ:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, และ D (T4 @ Ta = -20 องศาเซลเซียส ถึง +65 องศาเซลเซียส).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรับรอง ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eความสัมพันธ์การทำงานระหว่างรหัส 3500\/20-02-01-00 กับหมายเลขชิ้นส่วน 135031-01 คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e แสดงโครงสร้างการสั่งซื้อจากโรงงานหลายหลักที่กำหนดการสื่อสารแบบอนุกรมและการจัดวางเทอร์มินัลภายในเฉพาะ ในขณะที่ \u003cstrong\u003e135031-01\u003c\/strong\u003e คือหมายเลขชิ้นส่วนผู้ผลิตที่แน่นอนซึ่งกำหนดให้กับแผงวงจร I\/O ด้านหลังที่ส่งมอบภายในชุดนั้น\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฉันจะสลับตัวเลือกเครือข่ายพอร์ตอนุกรมด้านหลังระหว่างโปรโตคอล RS422 และ RS485 ได้อย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการเลือกโปรโตคอลต้องปรับตำแหน่งทางกายภาพของสวิตช์ไมโครฮาร์ดแวร์ที่อยู่บน \u003cstrong\u003e135031-01\u003c\/strong\u003e การประกอบการ์ดด้านหลังก่อนเปิดเครื่องอุปกรณ์\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการล้มเหลวโดยสมบูรณ์ของโมดูลอินเทอร์เฟซนี้จะขัดจังหวะวงจรทริปป้องกันเครื่องจักรหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eไม่ โมดูลทำงานนอกเส้นทางการตรวจสอบฮาร์ดแวร์หลักโดยตรง หมายความว่าการสูญเสียการสื่อสารหรือไฟฟ้ากับการ์ดนี้โดยสมบูรณ์จะไม่มีผลกระทบต่อวงจรทริปสินทรัพย์พื้นฐานหรือการดำเนินการตรวจสอบ\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eจะเกิดอะไรขึ้นหากเกิดข้อผิดพลาดของโมดูลที่ใดก็ได้ในตู้แร็ค 3500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eวงจรรีเลย์ Not-OK ที่รวมอยู่ในบล็อกแผงหลังจะเปลี่ยนสถานะสวิตช์ฮาร์ดแวร์ทันที ส่งสัญญาณเตือนระบบแบบฮาร์ดไวร์ไปยัง PLC ภายนอกหรือแผงสัญญาณเตือนได้ทันที\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864075115,"sku":"135031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module-jytao5rpj3n_3f8ea88d-edeb-4043-ac6e-7df04fa03052.jpg?v=1765449387"},{"product_id":"bently-nevada-3500-33-03-00-149992-03-low-current-16-channel-relay-output-module","title":"เบนท์ลีย์ เนวาด้า 3500\/33-03-00 149992-03 โมดูลเอาต์พุตรีเลย์ 16 ช่อง กระแสต่ำ","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/33-03-00 149992-03\u003c\/strong\u003e เป็นโมดูลรีเลย์เอาต์พุต 16 ช่องแบบเต็มความสูงที่ออกแบบมาเพื่อให้การโหวตความปลอดภัยที่โปรแกรมได้ขั้นสูงและตรรกะขับสัญญาณเตือนสำหรับ \u003cstrong\u003eระบบป้องกันเครื่องจักร 3500 Series\u003c\/strong\u003e ในฐานะชุดประกอบกระแสต่ำที่ตั้งค่าจากโรงงาน \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e มีขั้วรีเลย์ชุบทองเฉพาะที่ออกแบบมาเพื่อรับประกันความสมบูรณ์ของการติดต่อสูงสุดและป้องกันการเกิดออกไซด์บนพื้นผิวในแอปพลิเคชันสัญญาณกำลังต่ำ เอาต์พุตอิสระทั้งสิบหกช่องแต่ละช่องมี \u003cstrong\u003eตรรกะขับสัญญาณเตือน\u003c\/strong\u003e เฉพาะตัว ช่วยให้ผู้ปฏิบัติงานโปรแกรมเกต AND\/OR แบบผสมผสานที่ซับซ้อนโดยใช้สถานะเตือนภัย อันตราย หรือไม่ปกติที่รวบรวมจากโมดูลตรวจจับการสั่นสะเทือน ตำแหน่ง หรืออุณหภูมิใด ๆ ทั่วทั้งแร็ค โซลูชันฮาร์ดแวร์และซอฟต์แวร์ผสานนี้ทำหน้าที่เป็นสะพานตัดวงจรฉุกเฉินที่โหวตโดยฮาร์ดแวร์ที่เชื่อถือได้สูงระหว่างทรัพย์สินหมุนของโรงงานที่สำคัญกับระบบควบคุมแบบกระจาย (\u003cstrong\u003eDCS\u003c\/strong\u003e) ตัวควบคุมตรรกะโปรแกรมได้ (\u003cstrong\u003ePLC\u003c\/strong\u003e) หรือระบบปิดฉุกเฉิน (\u003cstrong\u003eESD\u003c\/strong\u003e)\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eชุดรีเลย์ความปลอดภัยแบบบูรณาการครบชุด 16 ช่องประกอบด้วย \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e รหัสระบบและ \u003cstrong\u003e149992-03\u003c\/strong\u003e บอร์ดโปรเซสเซอร์หลักที่มีขั้วติดต่อทอง\u003c\/li\u003e\n\u003cli\u003eขั้วติดต่อชุบทองบนบอร์ดที่ออกแบบมาเพื่อการสลับวงจรแรงดันต่ำและกระแสต่ำที่มีความเสถียรสูง\u003c\/li\u003e\n\u003cli\u003eเมทริกซ์ \u003cstrong\u003eตรรกะขับสัญญาณเตือน\u003c\/strong\u003e ที่ยืดหยุ่นสูง รองรับแผนการโหวตที่ปรับแต่งได้ตามตัวแปรเตือนภัยและอันตรายหลายช่อง\u003c\/li\u003e\n\u003cli\u003eสถาปัตยกรรมแบบถอดเปลี่ยนร้อน (hot-pluggable) ที่ช่วยให้เปลี่ยนการ์ดทางกายภาพได้อย่างราบรื่นโดยไม่รบกวนวงจรป้องกันเครื่องจักรที่อยู่ข้างเคียงที่กำลังออนไลน์\u003c\/li\u003e\n\u003cli\u003eการกำหนดสวิตช์ฮาร์ดแวร์แต่ละตัวบนแผงวงจรที่อนุญาตให้ตั้งค่าแบบปกติเปิด (\u003cstrong\u003eNE\u003c\/strong\u003e) หรือปกติปิด (\u003cstrong\u003eNDE\u003c\/strong\u003e) แยกกันสำหรับแต่ละรีเลย์\u003c\/li\u003e\n\u003cli\u003eการวินิจฉัย LED บนแผงหน้าปัดที่ชัดเจน ให้การประเมินสถานะโมดูลแบบเรียลไทม์ (OK) กิจกรรมบัสสื่อสารแบ็คเพลน (TX\/RX) และสถานะสัญญาณเตือนของแต่ละช่อง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eอินเทอร์เฟซลิงก์สัญญาณเตือนกระแสต่ำที่เชื่อมต่อแร็คป้องกันเครื่องจักรหมุนหนักกับ PLC อุตสาหกรรมและตัวควบคุมความปลอดภัย\u003c\/li\u003e\n\u003cli\u003eการโหวตตรรกะแบบกระจายและการแมปการปิดฉุกเฉินอัตโนมัติสำหรับกังหันไอน้ำ กังหันแก๊ส และคอมเพรสเซอร์ที่มีความสำคัญสูง\u003c\/li\u003e\n\u003cli\u003eสัญญาณเตือนการตัดวงจรป้องกันหลายจุดภายในโรงงานปิโตรเคมีที่มีความต้องการสูง โรงกลั่นน้ำมัน และสถานีผลิตไฟฟ้า\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eรหัสการสั่งซื้อ \/ หมายเลขชิ้นส่วนประกอบ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบาย\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eชุดโมดูลรีเลย์ 16 ช่องครบชุด พร้อมรีเลย์กระแสต่ำ ไม่มีการอนุมัติจากหน่วยงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกโมดูลรีเลย์กระแสต่ำ (ใช้โมดูลเอาต์พุตที่มีขั้วต่อทอง)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติจากหน่วยงาน: ไม่มี\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eส่วนประกอบบอร์ดหลัก:\u003c\/strong\u003e โมดูลรีเลย์หลัก 16 ช่อง กระแสต่ำ พร้อมขั้วต่อชุบทอง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่พารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eรายละเอียดข้อกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการกำหนดรวม\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลรีเลย์ 16 ช่อง (รุ่นกระแสต่ำ ชุบทอง)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eใช้พลังงานประมาณ 5.8 วัตต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทขั้วต่อรีเลย์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วต่อแบบขั้วเดียว สองทาง (SPDT) \/ ขั้วต่อชุบทอง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโหลดขั้วต่อขั้นต่ำ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V, 1 mA ขั้นต่ำ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโหลดขั้วต่อสูงสุด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Vdc ที่ 2 A แบบต้านทาน \/ 48 Vdc ที่ 0.2 A แบบต้านทาน \/ 125 Vdc ที่ 0.1 A แบบต้านทาน \/ 250 Vac ที่ 2 A แบบต้านทาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโหมดการทำงานของขั้วต่อ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสวิตช์บนบอร์ดเลือกได้สำหรับ Normally De-energized (NDE) หรือ Normally Energized (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส (-22 องศาฟาเรนไฮต์ ถึง +150 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความชื้นสัมพัทธ์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์ 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดการ์ดหลัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 241.8 มม. (9.50 นิ้ว x 0.96 นิ้ว x 9.52 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดการ์ด I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 99.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 3.90 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโมดูลหลัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 กก. (1.8 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโมดูล I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 กก. (0.9 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cp\u003eการอ่านค่าการวินิจฉัยที่แผงหน้าและการสิ้นสุดทางกายภาพที่ด้านหลังช่วยให้ติดตามอินเทอร์เฟซได้อย่างชัดเจน\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eตัวระบุส่วนประกอบ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบายการทำงาน \/ การกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไฟสถานะสุขภาพแผงหน้า; สว่างค้างเป็นสีเขียวเมื่ออัลกอริทึมซอฟต์แวร์ภายในทำงานปกติ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไฟสื่อสารแผงหน้า; กระพริบอย่างรวดเร็วเพื่อแสดงการรับส่งข้อมูลดิจิทัลบน backplane ที่กำลังทำงาน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED CHALRM (1 - 16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eไฟสถานะช่อง; LED อิสระสว่างขึ้นโดยตรงเมื่อช่องรีเลย์เฉพาะถูกทริกเกอร์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขั้วต่อบล็อกเทอร์มินัลด้านหลัง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eกลุ่มขาเชื่อมต่อ I\/O backplane รวมสาย Common (COM), Normally Open (NO) และ Normally Closed (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eสวิตช์โหมดรีเลย์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสวิตช์บนบอร์ดแบบหลายตำแหน่งแบบสองทางที่กำหนดสถานะช่องแต่ละช่องเป็น NDE หรือ NE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eตำแหน่งแร็ค:\u003c\/strong\u003e เลื่อนชุดโมดูล \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e ทั้งชุดเข้าไปในช่องความสูงเต็มที่ว่างอยู่ทางด้านขวาของโมดูลอินเทอร์เฟซข้อมูลชั่วคราว (\u003cstrong\u003eTDI\u003c\/strong\u003e) เท่านั้น\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการจัดแนวด้านหลัง:\u003c\/strong\u003e ติดตั้งโมดูลอินพุต\/เอาต์พุตการสิ้นสุดภายใน 16 ช่องที่ตรงกัน (เช่น 149986-01) ลงในช่องด้านหลังที่ตรงกับการ์ดหลักโดยตรง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตั้งค่าสวิตช์บนบอร์ด:\u003c\/strong\u003e ปรับสวิตช์ท็อกเกิลภายในเพื่อกำหนดสถานะปกติที่ต้องการว่าจะเป็น Normally Energized หรือ Normally De-energized สำหรับแต่ละช่องก่อนเลื่อนบอร์ดเข้าสล็อตที่เปิดใช้งานอยู่\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตรวจสอบแรงดันลูป:\u003c\/strong\u003e ยืนยันว่าลูปเครื่องมือวัดด้านล่างเป็นไปตามข้อจำกัดแรงดันต่ำและกระแสต่ำอย่างเคร่งครัด; การนำโหลดเหนี่ยวนำหนักหรือโหลดกำลังสูงเข้ามาจะทำลายพื้นผิวขั้วทองชุบ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับใช้ตรรกะ:\u003c\/strong\u003e เปิดชุดซอฟต์แวร์ระบบแร็คเพื่อแมปและดาวน์โหลดเมทริกซ์การโหวตความปลอดภัย AND\/OR ที่ต้องการลงในหน่วยความจำถาวรของโมดูลก่อนการทดสอบระบบ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eคำสั่ง EMC:\u003c\/strong\u003e คำสั่งชุมชนยุโรป 2014\/30\/EU (คำสั่ง EMC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eมาตรฐาน EMC:\u003c\/strong\u003e EN 61000-6-2 (ความต้านทานต่อสัญญาณรบกวนในอุตสาหกรรม), EN 61000-6-4 (การปล่อยสัญญาณรบกวนในอุตสาหกรรม)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eความปลอดภัยทางไฟฟ้า:\u003c\/strong\u003e คำสั่งแรงดันต่ำ 2014\/35\/EU, มาตรฐาน EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eคำสั่ง RoHS:\u003c\/strong\u003e 2011\/65\/EU การปฏิบัติตามมาตรฐานยุโรป\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรับรองพื้นที่อันตราย:\u003c\/strong\u003e cNRTLus Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc \/ Class I, Division 2, Groups A, B, C, และ D (T4 @ Ta = -20 องศาเซลเซียส ถึง +65 องศาเซลเซียส).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรับรอง ATEX\/IECEx:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eความสัมพันธ์ทางฟังก์ชันระหว่างรหัส 3500\/33-03-00 กับหมายเลขชิ้นส่วน 149992-03 คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eคือ \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e แทนหมายเลขรุ่นการสั่งซื้อจากโรงงานครบชุดที่ระบุระบบรีเลย์ 16 ช่องที่กำหนดค่าเพื่อใช้งานกระแสต่ำ ในขณะที่ \u003cstrong\u003e149992-03\u003c\/strong\u003e หมายเลขชิ้นส่วนผู้ผลิตที่แน่นอนพิมพ์อยู่บนบอร์ดโปรเซสเซอร์หลักที่มีกระแสต่ำซึ่งรวมอยู่ในชุดนั้น\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eทำไมการชุบทองจึงสำคัญสำหรับขั้วต่อบนโมดูลนี้?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eการชุบทองมีความสำคัญสำหรับวงจรที่มีกระแสต่ำ (ต่ำสุด 1 V, 1 mA) เพราะขั้วเงินมาตรฐานจะเกิดชั้นออกไซด์บนพื้นผิวเมื่อเวลาผ่านไปภายใต้ภาระไฟฟ้าต่ำ ในขณะที่ทองจะต้านทานการหมองเพื่อรับประกันเส้นทางการเชื่อมต่อที่สะอาด\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eฉันสามารถทำการสลับร้อนบนโมดูลนี้ได้ในขณะที่การตรวจสอบเครื่องจักรกำลังทำงานอยู่หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eใช่ หน่วยนี้มีสถาปัตยกรรมที่สามารถสลับร้อนเต็มรูปแบบ ทำให้ทีมบำรุงรักษาสามารถถอดหรือใส่การ์ดลงในสล็อตโดยไม่ต้องตัดไฟหรือทำให้สัญญาณในช่องมอนิเตอร์ข้างเคียงขาดหาย\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eการสั่งซื้อสินค้านี้ครั้งเดียวจะได้รับทั้งโปรเซสเซอร์ด้านหน้าและบอร์ดเทอร์มินัลด้านหลังหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eเมื่อซื้อเป็นชุดอะไหล่หรือชุดสำรองครบชุดตามข้อกำหนดของโรงงานนี้ โดยปกติจะหมายถึงบอร์ดหลัก; โปรดตรวจสอบว่าชุดแผงระบบของคุณต้องการบล็อกเทอร์มินัลภายในด้านหลัง 149986-01 ที่ตรงกันด้วยหรือไม่\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865549675,"sku":"3500\/33-03-00 149992-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-03-00-149992-03-spare-16-channel-low-current-relay-output-module-mybdn1u1yaf_20bc0d4c-1b25-4073-ac9e-559a8b4766c0.jpg?v=1765449433"},{"product_id":"bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","title":"Bently Nevada 3500\/61-01-01 133835-02 Temperature Monitor Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e133835-02\u003c\/strong\u003e) is a high-performance Temperature Monitor Isolated Input\/Output (I\/O) Module featuring internal terminations. Designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this module provides continuous tracking of machinery temperature variables to protect critical assets such as turbines, compressors, and large pumps from thermal damage.\u003c\/p\u003e\n\u003cp\u003eThis specific isolated configuration is engineered to eliminate ground loop interference, ensuring reliable data flow and preventing false trips in demanding environments like petrochemical refineries and power plants. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specific hardware component for isolated I\/O with internal termination resistors, facilitating direct thermocouple readings to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e (\u003cstrong\u003e133835-02\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouple I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouples (Type E, J, K, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VDC galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the model suffix is required to ensure compliance with hazardous area certifications and hardware compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e: Temperature Monitor Series Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Isolated Thermocouple I\/O Module with Internal Terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval (CN, ATEX, and IECEx for Zone 2 and Class I, Division 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Inspection\u003c\/strong\u003e: Examine module pins for damage and verify that jumper settings on the monitor card match the intended sensor type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Installation (Rear)\u003c\/strong\u003e: Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the rear chassis guides of the target slot. Seat the module firmly into the backplane and secure the thumb screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Module Installation (Front)\u003c\/strong\u003e: Insert the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor card into the front slot directly opposite the I\/O module. Secure with front panel screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect sensor leads directly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal blocks. For Thermocouples (TC), ensure correct polarity of positive and negative extension wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration Software via the TDI port to define sensor types and set Alert\/Danger setpoints before downloading to the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e: This design allows field wiring to connect directly to the I\/O module, eliminating the need for external terminal blocks and reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Failure Protection\u003c\/strong\u003e: The module features built-in detection for broken wires. A sensor fault triggers a \"Not OK\" status, alerting the DCS while preventing accidental machine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Constraints\u003c\/strong\u003e: This specific configuration (\u003cstrong\u003e-01\u003c\/strong\u003e) is dedicated to isolated thermocouple inputs. It cannot mix RTD and thermocouple signals on the same I\/O block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat certifications does the -01 approval option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt includes ATEX, IECEx, and CN certifications for use in Zone 2 and Class I, Division 2 hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external resistors for termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware contains internal termination resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation achieved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 500 VDC galvanic isolation to protect signal integrity from ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865779051,"sku":"3500\/61-01-01 133835-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-01-01-133835-02-rtd-tc-non-isolated-with-internal-terminations-otr0qowkozy_008e3679-5f87-4675-9c12-e49f7807f590.jpg?v=1765449441"},{"product_id":"bently-nevada-82926-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 82926-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e82926-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module is a rear-mounting backplane interface engineered for the Bently Nevada 3300\/20 Dual Thrust Position Monitor. This module supports two independent channels of continuous shaft axial position monitoring, processing raw DC gap voltage signals derived from proximity probe transducers to detect deviation relative to calibrated machine clearances. By establishing direct signal routing to the 3300 chassis bus, the hardware enables early warning of thrust bearing failure based on the position of the thrust collar relative to the axial bearing babbitt. The control logic of the associated monitor evaluates these dual-channel inputs against programmable alert and danger setpoints, providing isolated recorder terminal outputs for trend tracking and interfacing with emergency shutdown systems without on-board electro-mechanical relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82926-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20 Dual Thrust Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft axial position \/ Thrust displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo on-board relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.27 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module translates the transducer gap voltage into precise axial displacement metrics, measuring how far the shaft has shifted from its calibrated electrical zero point.\u003c\/li\u003e\n\u003cli\u003eTo achieve proper rotor dynamics representation, the external proximity probes must be installed to observe the thrust collar directly rather than an arbitrary shaft shoulder.\u003c\/li\u003e\n\u003cli\u003eBecause the 82926-01 does not include mechanical relays, any active automatic machinery trip functions must be executed via backplane communication to a dedicated 3300 series relay module.\u003c\/li\u003e\n\u003cli\u003eDisconnecting or miswiring the terminal block outputs will register as a transducer fault or an out-of-limit gap voltage error on the front display of the 3300\/20 monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols at the rear terminal strip by landing the proximity probe extension cable shield at the chassis ground terminal and isolating it at the sensor case.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between low-voltage transducer input lines and high-voltage AC utility or control wiring to minimize electromagnetic noise injection into the thrust position loop.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal lug screws are securely torqued during commissioning to prevent drift in the 4-20 mA recorder loops or intermittent sensor faults caused by mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eAlign the module pins perfectly with the 3300 rack backplane before inserting to avoid bending contacts or disrupting cyclic data exchange with adjacent modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 82926-01 terminal module feature integrated mechanical relays for machinery interlocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 82926-01 is a passive transducer input\/output and recorder terminal module that passes signal states to the 3300 backplane, requiring a separate relay module for physical contact execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal module be used to interface with radial vibration or casing velocity monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this specific part number is designed and mapped exclusively to match the electrical and channel parameters of the 3300\/20 Dual Thrust Position Monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the recorder terminals on this rear module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recorder terminals provide dedicated, continuous analog outputs proportional to the measured shaft axial position, allowing for direct connection to external DCS or chart recorders.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866499947,"sku":"82926-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-82926-01-i-o-and-record-terminals-relay-module-5onmhshp13c_f9312740-5fab-45b3-a3b6-9cfa1c7c35b5.jpg?v=1765449471"},{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 146031-02 | โมดูล I\/O 3500\/22M 100Base-FX (ไฟเบอร์ออปติก)","description":"\u003cp\u003e\u003cspan\u003e146031-02\u003c\/span\u003e ทำหน้าที่เป็นอินเทอร์เฟซด้านหลังที่จำเป็นสำหรับ \u003cstrong\u003e3500\/22M Transient Data Interface (TDI)\u003c\/strong\u003e ขณะที่โมดูลด้านหน้าดำเนินการประมวลผลสัญญาณที่ซับซ้อน ส่วนประกอบ I\/O นี้จะสร้างชั้นกายภาพสำหรับการสื่อสารเครือข่ายและการแจ้งเตือนฮาร์ดแวร์\u003c\/p\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eข้อมูลจำเพาะ\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e146031-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eโปรโตคอลการสื่อสาร\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eพอร์ตอินเทอร์เฟซ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 (มีชิลด์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eความเข้ากันได้กับโฮสต์\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/22M TDI (เช่น 288055-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eรีเลย์เอาต์พุต\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eรีเลย์ \"OK\" เฉพาะ (SPDT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eตำแหน่งติดตั้ง\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eช่องด้านหลังของชั้นวาง (อยู่ตรงหลัง TDI โดยตรง)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eมาตรฐานสายไฟ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCat5e \/ Cat6 STP (สายบิดเกลียวมีชิลด์)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eข้อได้เปรียบทางวิศวกรรม\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการสตรีมข้อมูลแบนด์วิดธ์สูง:\u003c\/strong\u003e อินเทอร์เฟซ 100Base-TX ช่วยให้สามารถสตรีมข้อมูลเวฟฟอร์มความละเอียดสูงไปยังซอฟต์แวร์ \u003cstrong\u003eSystem 1\u003c\/strong\u003e ได้อย่างราบรื่น ป้องกันปัญหาคอขวดข้อมูลในช่วงเหตุการณ์ชั่วคราวที่สำคัญ (การเริ่มต้น\/ปิดเครื่อง)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการแยกไฟฟ้าที่ดีขึ้น:\u003c\/strong\u003e รุ่น -02 มีวงจรป้องกันที่เหนือกว่ารุ่นเก่า ช่วยปกป้องชั้นวาง 3500 จากสัญญาณรบกวนโหมดทั่วไปและแรงดันกระชากที่พบในวงจรกราวด์อุตสาหกรรม\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการตรวจสอบสุขภาพระบบที่แน่นอน:\u003c\/strong\u003e รีเลย์ \u003cstrong\u003eOK Relay\u003c\/strong\u003e ที่รวมอยู่ให้การเชื่อมต่อฮาร์ดไวร์กับระบบควบคุมแบบกระจาย (DCS) โดยส่งสัญญาณทันทีเมื่อฮาร์ดแวร์ TDI ล้มเหลว เพื่อให้ผู้ปฏิบัติงานไม่ต้องพึ่งพาข้อมูลการตรวจสอบที่ผิดพลาด\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eความต้านทาน EMI ที่เหมาะสม:\u003c\/strong\u003e ด้วยการใช้การเชื่อมต่อ RJ45 ที่มีชิลด์ โมดูลนี้รักษาความสมบูรณ์ของสัญญาณแม้ติดตั้งใกล้กับไดรฟ์ความถี่แปรผันแรงดันสูง (VFDs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eคำถามที่พบบ่อย\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: 146031-02 รองรับโปรเซสเซอร์ด้านหน้า 3500\/22M รุ่นเก่าหรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตอบ:\u003c\/strong\u003e ใช่ โมดูลนี้ยังคงเข้ากันได้เต็มที่กับโปรเซสเซอร์ 3500\/22M TDI รุ่นเก่า (เช่น 138607-01) อย่างไรก็ตาม มันถูกปรับแต่งเพื่อเพิ่มประสิทธิภาพสำหรับรุ่นใหม่ 288055-01 เพื่อใช้มาตรฐาน Ethernet สมัยใหม่\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ฉันจะตรวจสอบสถานะ \"ใหม่เอี่ยม\" ของโมดูลนี้ได้อย่างไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตอบ:\u003c\/strong\u003e ทุกหน่วยมาพร้อมบรรจุภัณฑ์ป้องกันไฟฟ้าสถิตที่ปิดผนึกจากโรงงาน หมายเลขซีเรียลบน PCB ตรงกับป้าย Bently Nevada ด้านนอก และรีเลย์ \"OK\" ยังไม่ผ่านรอบการทำงานใด ๆ เรามีใบรับรองความถูกต้อง (CoC) ให้ตามคำขอเพื่อรับประกันความแท้จริง\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: ขั้นตอนการติดตั้งที่สำคัญสำหรับ 146031-02 คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eตอบ:\u003c\/strong\u003e คุณต้องติดตั้งโมดูลนี้ที่ด้านหลังของชั้นวาง 3500 โดยตรงหลังช่องที่ติดตั้ง 3500\/22M TDI ใช้สายเคเบิล Shielded Twisted Pair (STP) เท่านั้น หากไม่กราวด์ชิลด์ Ethernet ผ่านพอร์ต RJ45 อาจทำให้เกิดสัญญาณรบกวนในตัวอย่างข้อมูลชั่วคราว\u003c\/p\u003e\n\u003ch3\u003eความเข้ากันได้ \u0026amp; การจัดส่ง\u003c\/h3\u003e\n\u003ch4\u003eข้อกำหนดระบบ\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลด้านหน้า:\u003c\/strong\u003e ต้องใช้ Bently Nevada 3500\/22M TDI (288055-01 หรือ 138607-01)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eซอฟต์แวร์:\u003c\/strong\u003e เข้ากันได้เต็มที่กับ \u003cstrong\u003eSystem 1\u003c\/strong\u003e สำหรับการตรวจสอบสภาพและ \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eสายเคเบิล:\u003c\/strong\u003e ใช้สาย Cat5e หรือ Cat6 STP สำหรับข้อมูล และใช้สายไฟขนาด 18 AWG ถึง 22 AWG สำหรับบล็อกเทอร์มินัลรีเลย์ OK\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eการจัดส่ง \u0026amp; สภาพสินค้า\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eสภาพสินค้า:\u003c\/strong\u003e ใหม่เอี่ยม 100% สต็อกโรงงานแท้\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eบรรจุภัณฑ์:\u003c\/strong\u003e รวมกล่อง Bently Nevada ดั้งเดิมพร้อมการป้องกัน ESD ภายใน\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโลจิสติกส์ทั่วโลก:\u003c\/strong\u003e เรามีบริการจัดส่งด่วนระหว่างประเทศผ่าน DHL, FedEx และ UPS พร้อมบริการซีลสุญญากาศสำหรับการขนส่งทางทะเลระยะไกลตามคำขอ เพื่อป้องกันการเกิดออกซิเดชันในสภาพแวดล้อมที่ชื้น\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506"},{"product_id":"bently-nevada-135489-01-3500-42m-i-o-module-with-internal-barriers","title":"โมดูล Bently Nevada 135489-01 3500\/42M I\/O พร้อมอุปสรรคภายใน","description":"\u003ch3\u003eภาพรวมสินค้า\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e135489-01\u003c\/strong\u003e เป็นโมดูลอินพุต\/เอาต์พุต (I\/O) 4 ช่องที่ออกแบบมาเพื่อใช้กับเครื่องตรวจจับแผ่นดินไหว Proximitor รุ่น \u003cstrong\u003e3500\/42M\u003c\/strong\u003e ภายในระบบป้องกันเครื่องจักร \u003cstrong\u003e3500 Series\u003c\/strong\u003e ฮาร์ดแวร์รุ่นนี้มาพร้อมกับ \u003cstrong\u003eอุปสรรคภายใน\u003c\/strong\u003e และ \u003cstrong\u003eการต่อสายภายใน\u003c\/strong\u003e ซึ่งให้ส่วนต่อประสานที่กะทัดรัดและปลอดภัยโดยเนื้อแท้สำหรับทรานสดิวเซอร์ที่ตั้งอยู่ในสภาพแวดล้อมอุตสาหกรรมที่เป็นอันตราย\u003c\/p\u003e\n\u003cp\u003eโมดูลนี้ประมวลผลสัญญาณสำหรับ \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e (ทรานสดิวเซอร์แบบใกล้หรือเครื่องวัดความเร่ง) บนช่อง 1 ถึง 4 โดยการรวมอุปสรรคความปลอดภัยภายใน, \u003cstrong\u003e135489-01\u003c\/strong\u003e จำกัดพลังงานไฟฟ้าที่ส่งไปยังเซ็นเซอร์ภาคสนาม ป้องกันการจุดระเบิดในบรรยากาศที่ระเบิดได้ในขณะเดียวกันก็ไม่ต้องใช้ฮาร์ดแวร์อุปสรรคภายนอก เป็นส่วนประกอบสำคัญสำหรับการตรวจสอบการสั่นสะเทือน ตำแหน่ง และกิจกรรมแผ่นดินไหวบนทรัพย์สินหมุนที่มีมูลค่าสูง เช่น กังหัน เครื่องอัด และมอเตอร์\u003c\/p\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแบรนด์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O พร้อมอุปสรรคภายใน (การต่อสายภายใน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eซีรีส์ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโมดูลหลักที่เข้ากันได้\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3500\/42M\u003c\/strong\u003e เครื่องตรวจจับแผ่นดินไหว Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภททรานสดิวเซอร์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x Prox\/Accel (ช่อง 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 องศาเซลเซียส ถึง +65 องศาเซลเซียส (32 องศาฟาเรนไฮต์ ถึง +150 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความชื้น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้น 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 163.1 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 กก. (1.01 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eแหล่งกำเนิด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cp\u003eเมื่อจัดหาชิ้นส่วนอะไหล่สำหรับ \u003cstrong\u003e3500\/42M\u003c\/strong\u003e ระบบ, ตรวจสอบตัวเลือกการสั่งซื้อเฉพาะเพื่อให้แน่ใจว่าโมดูล I\/O ตรงกับข้อกำหนดการต่อสายและอุปสรรคของแร็ค\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e: \u003cstrong\u003e135489-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eตัวเลือกการสั่งซื้อ AA\u003c\/strong\u003e: 04\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eคำอธิบาย I\/O\u003c\/strong\u003e: โมดูล I\/O พร้อมอุปสรรคภายใน, การต่อสายภายใน, 4 x Prox\/Accel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eบันทึกทางวิศวกรรม \u0026amp; การติดตั้ง\u003c\/h3\u003e\n\u003ch3\u003eการเดินสายภาคสนาม \u0026amp; การต่อสายภายใน\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการเชื่อมต่อโดยตรง\u003c\/strong\u003e: \u003cstrong\u003e135489-01\u003c\/strong\u003e ใช้การต่อสายภายใน หมายความว่าสายไฟจากทรานสดิวเซอร์ในสนามจะเชื่อมต่อโดยตรงกับเทอร์มินัลสกรูบนตัวโมดูลที่อยู่ด้านหลังของแร็ค 3500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eความปลอดภัยในพื้นที่อันตราย\u003c\/strong\u003e: อุปสรรคภายในถูกออกแบบมาเพื่อรักษาความสมบูรณ์ของวงจรที่ปลอดภัยโดยเนื้อแท้ (IS) ตรวจสอบให้แน่ใจว่าการแยกสายไฟระหว่างสาย IS ในสนามและสายที่ไม่ใช่ IS ภายในตู้ถูกต้อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการรองรับทรานสดิวเซอร์\u003c\/strong\u003e: โมดูลนี้ได้รับการจัดอันดับเฉพาะสำหรับอินพุต \u003cstrong\u003eProximity\u003c\/strong\u003e และ \u003cstrong\u003eAccelerometer\u003c\/strong\u003e ยืนยันว่าประเภททรานสดิวเซอร์ในสนามตรงกับการกำหนดค่าช่องสัญญาณ (ช่อง 1-4) เพื่อหลีกเลี่ยงข้อผิดพลาดในการประมวลผลสัญญาณ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eขั้นตอนการติดตั้ง\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการจับคู่กับมอนิเตอร์\u003c\/strong\u003e: โมดูล I\/O นี้ต้องติดตั้งในช่องด้านหลังของแร็ค 3500 ที่สอดคล้องกับโมดูลมอนิเตอร์ \u003cstrong\u003e3500\/42M\u003c\/strong\u003e ที่ติดตั้งด้านหน้า\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eข้อกำหนดแรงบิด\u003c\/strong\u003e: ตรวจสอบให้แน่ใจว่าสกรูเทอร์มินัลทั้งหมดถูกขันอย่างถูกต้องเพื่อรักษาการเชื่อมต่อทางไฟฟ้าที่มั่นคง โดยเฉพาะในสภาพแวดล้อมที่มีการสั่นสะเทือนในอุตสาหกรรม\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการปฏิบัติตามข้อกำหนดด้านสิ่งแวดล้อม\u003c\/strong\u003e: สำหรับโมดูลที่ใช้กับอุปสรรคภายใน อุณหภูมิการทำงานต้องรักษาให้อยู่ระหว่าง \u003cstrong\u003e0 องศาเซลเซียส ถึง +65 องศาเซลเซียส\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูล I\/O นี้สามารถใช้กับทรานสดิวเซอร์ Velomitor ได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e135489-01\u003c\/strong\u003e ถูกกำหนดสำหรับ \u003cstrong\u003e4 x Prox\/Accel\u003c\/strong\u003e การใช้งานกับประเภททรานสดิวเซอร์อื่นอาจต้องใช้โมดูล I\/O แบบอื่นหรือการปรับแต่งการตั้งค่าภายในมอนิเตอร์ \u003cstrong\u003e3500\/42M\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eประโยชน์ของเวอร์ชัน \"Internal Barrier\" คืออะไร?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eมันรวมอุปสรรคความปลอดภัยไว้ในโมดูล I\/O โดยตรง ช่วยลดพื้นที่ทางกายภาพที่ต้องใช้ในตู้และทำให้สถาปัตยกรรมการเดินสายสำหรับการใช้งานในพื้นที่อันตรายง่ายขึ้น\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้สามารถสลับร้อนได้หรือไม่?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eในขณะที่ระบบ 3500 รองรับการสลับร้อน การปฏิบัติทางวิศวกรรมมาตรฐานคือการข้ามการหยุดทำงานของเครื่องจักรที่เกี่ยวข้องก่อนเปลี่ยนโมดูล I\/O เพื่อป้องกันการปิดเครื่องโดยไม่ได้ตั้งใจ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869055851,"sku":"135489-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-01-i-o-module-4-channel-internal-barrier-akragbb2a4i_c5513e8d-df36-47f1-b473-bf9c4c7b9969.jpg?v=1765449560"},{"product_id":"bently-nevada-3500-42m-135489-02-proximitor-seismic-i-o-module","title":"Bently Nevada 3500\/42M 135489-02 Proximitor Seismic I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-144\"\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan class=\"citation-144\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 4-channel Proximitor Seismic I\/O Module with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eInternal Intrinsic Safety Barriers\u003c\/strong\u003e\u003cspan class=\"citation-144 citation-end-144\"\u003e\u003cspan\u003e \u003c\/span\u003eand Internal Terminations designed for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeated in the rear slot of the 3500 instrumentation rack, this module serves as the direct hardware interface linking field-mounted sensors to the front-facing 3500\/42M Proximitor Seismic Monitor module.\u003c\/p\u003e\n\u003cp\u003eThe hardware architecture provides two dedicated proximity\/acceleration channels and two specialized Velomitor channels.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003eEquipped with integrated Zener-type internal barriers, the 135489-02 restricts electrical fault energy traveling from the rack into the field, providing explosion-proof protection for transducers deployed in Class I, Division 1 or Zone 0 hazardous environments without the need for external galvanic isolation panels.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/42M (Rear Barrier Variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e135489-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Seismic I\/O Module with Internal Barriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Proximity\/Acceleration + 2 Velomitor channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Intrinsic Safety Barriers (Internal Zener Barriers)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Multi-position Screw Terminal Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Transducers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Probes, Accelerometers, Velomitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConditioned Values\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust, Eccentricity, Velocity, Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.201 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eMachinery verification networks operating in hazardous processing environments require exact tracking of rear I\/O card variation codes. Procure components matching the factory keys below.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain System Core Monitor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Order Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e135489-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Front Module Counterpart:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/42M Proximitor Seismic Processor Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Wiring and Barrier Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003eThe 135489-02 card houses integrated explosion protection circuitry.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eField wiring routing out from the module's terminal block must follow strict intrinsic safety segregation guidelines.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep all intrinsically safe field transducer cables physically separated from non-intrinsically safe wires by a minimum clearance boundary of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2.0 inches)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDividers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlternatively, install dedicated grounded metal dividers to avoid voltage arc induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Screw Terminal Allocation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField cabling maps directly onto the built-in internal termination blocks. Use high-quality 3-wire twisted-shielded instrumentation cables (18 AWG to 22 AWG copper) to carry low-voltage displacement and acceleration paths.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip individual conductor insulation jackets back exactly 7 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect outer grounding shields together and anchor them to the clean instrumentation earth rail at the structural cabinet bulkhead.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDo not\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eloop shield drain wires through the proximity signal common (COM) screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Handshake and Safety Restrictions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the 135489-02 limits terminal fault currents through precision internal barriers, plugging non-designated transducer loads into the channel pins can overload the internal Zener elements, destroying the protection loop. Prior to activating sensor excitation power, match the channel selection parameters (e.g., standard proximity probe versus Velomitor configuration) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto align with specific paired-channel hardware attributes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 135489-02 and standard 3500\/42M I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003eA: The 135489-02 features built-in internal safety barriers.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eStandard I\/O versions do not contain intrinsic insulation paths, requiring plants to source and mount independent, external barrier boards when routing sensor leads into classified hazardous plant fields.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the channel structure split into two distinct sensor pairs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The hardware layout dictates specialized input electronics. Channels 1 and 2 are balanced to process voltage variables from high-frequency proximity probes or accelerometers, while Channels 3 and 4 feature targeted current loops designed specifically for active Velomitor-type velocity sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I hot-swap this rear I\/O module while the 3500 rack is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the front-facing 3500\/42M card allows hot-swapping, extracting the rear 135489-02 while powered up breaks the physical sensor feedback loop and cuts excitation paths. This immediately triggers system interlocks and trips connected safety relays. Always change the rack security keyswitch to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode and establish channel bypass blocks before initiating hardware service.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869612907,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-cfy5l5nmfwu_80b4d093-609f-4e33-a266-6b0411b744dd.jpg?v=1765449578"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568"},{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-cc-pail51-experion-series-c-low-level-analog-input-module","title":"Honeywell CC-PAIL51 Experion Series-C Low Level Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-71\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-71\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-71\"\u003eCC-PAIL51 (CCPAIL51)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-71\"\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance temperature sensing solution within the Honeywell Experion Series-C Mark II I\/O family\u003c\/span\u003e\u003cspan class=\"citation-71 citation-end-71\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-70\"\u003e\u003c\/span\u003eSpecifically engineered for mission-critical thermal monitoring in industries such as hydrocarbon processing and power generation, this Low Level Analog Input (LLAI) module provides high-density support for 16 RTD and Thermocouple (TC) circuits\u003cspan class=\"citation-70 citation-end-70\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-69\"\u003e\u003c\/span\u003eThe module’s core value lies in its high-integrity data qualification; it features a fixed 1-second PV scanning rate coupled with advanced Open Thermocouple Detection (OTD) protection\u003cspan class=\"citation-69 citation-end-69\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-68\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-68\"\u003eBy automatically setting Process Variables to \"Not a Number\" (NAN) upon sensor failure, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-68\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-68\"\u003e\u003cspan\u003e \u003c\/span\u003eprevents erratic control loop responses, effectively reducing plant risk and minimizing expensive unscheduled maintenance caused by instrument degradation\u003c\/span\u003e\u003cspan class=\"citation-68 citation-end-68\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-67\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-67\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-67\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-67\"\u003e\u003cspan\u003e \u003c\/span\u003ehardware is optimized for signal stability and thermal management within high-density cabinet environments\u003c\/span\u003e\u003cspan class=\"citation-67 citation-end-67\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-66\"\u003eComprehensive Sensor Library:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-66\"\u003e\u003cspan\u003e \u003c\/span\u003eNative linearization for a broad spectrum of sensors, including Platinum (100 ohm), Nickel (120 ohm), and Copper (10\/50 ohm) RTDs, as well as ANSI Type J, K, E, T, B, S, and R thermocouples\u003c\/span\u003e\u003cspan class=\"citation-66 citation-end-66\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-65\"\u003eTotal Galvanic Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-65\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides robust 16-channel isolation, including channel-to-channel, channel-to-DCS backplane, and channel-to-power common, shielding sensitive measurements from ground loop interference\u003c\/span\u003e\u003cspan class=\"citation-65 citation-end-65\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1-second update cycle includes a mandatory OTD check before PV propagation.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-64\"\u003e\u003c\/span\u003eIf sensor resistance exceeds 1500 ohms, the system triggers a guaranteed trip to protect control integrity\u003cspan class=\"citation-64 citation-end-64\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-63\"\u003eSeries-C Mark II Innovation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-63\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the \"tilted\" module design for superior heat dissipation and features a vertical mounting profile to streamline high-density field wiring entry\u003c\/span\u003e\u003cspan class=\"citation-63 citation-end-63\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eCC-PAIL51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eHoneywell Experion Series-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003eLow Level Analog (Temperature) Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e16 (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 second (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eIOTA Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e\n\u003ca href=\"https:\/\/www.plcprotech.com\/products\/dc-tail51-honeywell-series-c-analog-output-24v-iota-module\"\u003eDC-TAIL51\u003c\/a\u003e (Non-Redundant 9-inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eNominal Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e-20 to +100 mV (TC only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eGain Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0.050% Full Scale Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e+\/- 20 ppm per deg C Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eCMRR (50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e120 dB Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eRTD Excitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e1 milliamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0144%;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.6245%;\"\u003e0 to 60 deg C (Standard Series-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PAIL51 prevent \"false\" control actions during a sensor break?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-62\"\u003e\u003c\/span\u003eThe module utilizes a \"sample and hold\" OTD cycle\u003cspan class=\"citation-62 citation-end-62\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-61\"\u003e\u003c\/span\u003eIf an open sensor is detected, the Process Variable is set to NAN (Not a Number) and a soft failure is reported\u003cspan class=\"citation-61 citation-end-61\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-60\"\u003e\u003c\/span\u003eThis ensures no invalid data is propagated to the controller, preventing inappropriate PID responses\u003cspan class=\"citation-60 citation-end-60\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific IOTA options for this module?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-59\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eCC-PAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003etypically resides on the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"citation-59\"\u003eDC-TAIL51\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-59\"\u003e\u003cspan\u003e \u003c\/span\u003eIOTA, which is a 9-inch (228 mm) assembly for non-redundant applications\u003c\/span\u003e\u003cspan class=\"citation-59 citation-end-59\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support millivolt-only inputs without linearization?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-58\"\u003e\u003c\/span\u003eYes, the module supports standard millivolt types ranging from -20 to +100 millivolts, allowing it to interface with specialized non-standard sensing devices\u003cspan class=\"citation-58 citation-end-58\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-57\"\u003eCold Junction Compensation (CJC):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-57\"\u003e\u003cspan\u003e \u003c\/span\u003eAll thermocouple inputs are automatically compensated using a CJC device located on the IOTA\u003c\/span\u003e\u003cspan class=\"citation-57 citation-end-57\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. To ensure accuracy, avoid installing the IOTA near high-heat components that could create localized thermal gradients across the termination assembly. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-56\"\u003eRTD Wiring Integrity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-56\"\u003e\u003cspan\u003e \u003c\/span\u003eFor RTD sensors, lead resistance must be strictly managed (maximum 15 ohms)\u003c\/span\u003e\u003cspan class=\"citation-56 citation-end-56\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-55\"\u003e\u003c\/span\u003eUse high-quality shielded 3-wire or 4-wire cabling to maintain the 120 dB Common Mode Rejection Ratio (CMRR) and prevent noise from distorting low-level temperature signals\u003cspan class=\"citation-55 citation-end-55\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan class=\"citation-54\"\u003eSurge Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"citation-54\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module features integrated surge protection per EN 61000-4-5 (1 kV line-to-line, 2 kV line-to-ground)\u003c\/span\u003e\u003cspan class=\"citation-54 citation-end-54\"\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e. For outdoor sensor runs or environments with high lightning risk, external primary surge arrestors are still recommended to protect the IOTA electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668023210347,"sku":"CC-PAIL51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-pail51-low-level-analog-output-ffkuwq3reb5_d4e37d60-6deb-45a2-8082-bc85412bb644.jpg?v=1765505238"},{"product_id":"honeywell-experion-pks-8c-tdoda1-51307149-175-digital-output-iota","title":"Honeywell Experion PKS 8C-TDODA1 (51307149-175) Digital Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 32-channel Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This \"Single\" IOTA serves as the mounting base and field wiring interface for a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output module. It is engineered to drive 24 VDC discrete field devices such as solenoid valves, relays, and indicator lamps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the signature Series 8 vertical design, which significantly reduces the cabinet footprint while enhancing thermal management through natural convection. This specific version (51307149-175) is factory-treated with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e, providing a critical layer of protection against moisture and corrosive atmospheric elements commonly found in industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a ruggedized electrical interface for discrete control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Accommodates 32 digital output channels, allowing for high-density wiring and simplified common-return routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix indicates compliance with ISA S71.04 Class G3, protecting the PCB and components from corrosive gases like Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Series 8 Form Factor\u003c\/strong\u003e: Fits onto a standard Series 8 carrier, facilitating an efficient \"chimney-effect\" airflow that keeps the electronic module cool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Circuit Protection\u003c\/strong\u003e: Designed to work with the I\/O module’s diagnostic capabilities, including short-circuit protection and load monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly Design\u003c\/strong\u003e: Allows for the electronic I\/O module to be replaced (\"hot-swapped\") without disconnecting the field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDODA1 is a \"Single\" IOTA, meaning it has only one slot for an I\/O module. For redundant DO applications where two modules back up each other, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eredundant IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module can drive typical 24 VDC solenoids, the total current capacity is limited. For high-current loads or high-frequency switching, it is highly recommended to use interposing relays to prevent thermal stress on the IOTA and module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power provided to the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField excitation power (24 VDC) is usually supplied through the Series 8 carrier busbar. The IOTA then distributes this power to the individual channels based on the commands from the C300 controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse ferrules on all field wiring to ensure reliable contact and prevent stray wire strands from shorting adjacent terminals in the high-density terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is firmly snapped into the carrier and that the carrier itself is properly bonded to the instrument ground bar. Inadequate grounding can lead to intermittent diagnostic errors and susceptibility to electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the \"Blown Fuse\" diagnostics in the Experion software. If a fuse-protected circuit is used, identify and rectify the field-side short circuit before replacing the module or resetting the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the manufacturer-specified 150 mm clearance above and below the IOTA row to ensure adequate cooling. Overheating is a primary cause of shortened electronic lifespan in high-density DC cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027765099,"sku":"8C-TDODA1 51307149-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdoda1-51307149-175-digital-output-bussed-irxllnpltok_da87522a-b045-4c95-88b5-ba132f5cec30.jpg?v=1765505296"},{"product_id":"honeywell-experion-pks-8c-paona1-51454469-175-analog-output-module","title":"Honeywell Experion PKS 8C-PAONA1 (51454469-175) Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 16-channel Analog Output (AO) module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O architecture. As a core component of the C300 control system, this module converts digital control algorithms into accurate 4-20 mA analog signals to drive final control elements such as valve positioners, variable speed drives, and dampers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for high-density deployments, featuring the Series 8 slim vertical form factor that enhances natural convection cooling. This \"175\" variant comes standard with a factory-applied G3 conformal coating, providing essential protection against corrosive atmospheric contaminants. By ensuring stable signal delivery in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in maintaining process stability and reducing the total cost of ownership through enhanced hardware durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its ruggedized electronics and seamless integration with the Series 8 I\/O Link.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Supports up to 16 independent analog loops per module, maximizing I\/O density within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-HART Signal Path\u003c\/strong\u003e: Dedicated to standard 4-20 mA analog modulation, offering a streamlined and cost-effective solution for control loops that do not require digital HART diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51454469-175 hardware revision is specifically treated to resist corrosion from H2S, Cl2, and ammonia, meeting ISA S71.04 Class G3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides comprehensive electrical isolation between field wiring and the internal system bus, protecting the C300 controller from field transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: Fully compatible with redundant Series 8 IOTAs, allowing for seamless bumpless transfer in high-availability control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454469-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 9.80 x 4.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 8C-PAONA1 with an 8C-PAOHA1 (HART version)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8C-PAOHA1 is generally backward compatible and can reside on the same IOTA. However, you must update the module configuration in the Experion Control Builder to enable the HART features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Non-HART\" designation mean for my field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means this module only transmits the 4-20 mA analog signal. If you have \"Smart\" valve positioners, they will still move correctly based on the current, but the DCS will not be able to read digital diagnostic data or valve signatures from them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the G3 coating on this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number suffix \"175\" is the primary indicator of the G3 conformal coating. Physically, the board will have a slight uniform sheen compared to non-coated \"100\" series boards when viewed under reflected light.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAONA1 is designed to drive loads up to a maximum of 600 Ohms. Before commissioning, calculate the total loop resistance including the field wire run and the positioner impedance. High-resistance loops can cause the output to saturate or trigger \"Output Open\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). In a redundant configuration, ensure the \"OK\" LED on the partner module is solid green before removing the module being serviced to prevent a process upset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, use individual shielded twisted-pair cables for each AO channel. The shields must be terminated at the IOTA's ground bar to prevent electromagnetic interference from inducing \"jitter\" in the valve control signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031205739,"sku":"8C-PAONA1 51454469-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona1-51454469-175-analog-output-module-pr3lnm2gi33_9db50288-9e32-48b9-bb61-3adc7964f986.jpg?v=1765505321"},{"product_id":"honeywell-experion-pks-8c-tdila1-51307141-175-digital-input-iota","title":"Honeywell Experion PKS 8C-TDILA1 (51307141-175) Digital Input IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. This module acts as the physical and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input module, providing 32 channels of discrete signal acquisition. It is designed to interface with field contacts such as push-buttons, limit switches, and motor starter auxiliary contacts. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with the signature Series 8 vertical orientation to optimize cabinet space and enhance thermal management through natural convection. This specific variant, identified by part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51307141-175\u003c\/strong\u003e, features a factory-applied G3 conformal coating, making it resilient against corrosive gases and high-humidity environments typical in oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-speed signal processing and simplified field maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Provides terminal connections for up to 32 discrete inputs, sharing a common return to maximize wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix ensures the board is treated to withstand harsh environmental conditions, protecting against corrosion from Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e: Mounts onto a Series 8 carrier, allowing for a \"slim\" I\/O profile that significantly reduces the overall footprint of the DCS cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Management\u003c\/strong\u003e: Distributes 24 VDC field excitation power to the input contacts while maintaining electrical isolation for the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: The IOTA design allows for the replacement of the electronic I\/O module without disturbing the field wiring connected to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307141-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-TDILA1 support redundant input module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDILA1 is a \"Single\" IOTA, meaning it supports only one 8C-PDILA1 module. For redundant applications where two modules monitor the same 32 field points, you must use the redundant version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILB1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field excitation voltage does this IOTA provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis IOTA is designed for 24 VDC discrete inputs. The 24 VDC power is typically sourced from the system power supply through the Series 8 carrier bus and distributed to the field contacts via the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a non-corrosive environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the G3 coating (51307141-175) is designed for harsh environments, it is fully compatible with standard control room environments. It provides an extra layer of protection against unexpected humidity or airborne contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 32-channel density, use fine-stranded wire with ferrules for all connections to the compression terminals. Clear labeling and organized wire ducting are essential to prevent cross-talk and facilitate future troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is properly snapped into the Series 8 carrier and that the carrier is bonded to the instrument earth bar. Proper grounding is critical for the internal surge protection circuitry to function correctly during field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended 150 mm clearance above and below the IOTA row. The vertical design relies on the \"chimney effect\" for cooling; obstructing airflow can lead to localized hotspots and premature failure of the inserted I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031304043,"sku":"8C-TDILA1 51307141-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdila1-51307141-175-input-module-hhpp2chb3tf_64736da3-58c9-4b6e-97d0-b96456e712d1.jpg?v=1765505322"},{"product_id":"honeywell-experion-pks-8c-paona2-analog-output-module-non-hart","title":"Honeywell Experion PKS 8C-PAONA2 Analog Output Module (Non-HART)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA2 (8CPAONA2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Output (AO) module belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. Engineered for precision and mission-critical reliability, this 16-channel module converts digital control commands from the C300 controller into standard 4-20 mA analog signals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used to drive final control elements such as pneumatic valve positioners, variable speed drives (VSD), and dampers. As a \"Series 8\" component, it features a vertical, slimline design that optimizes cabinet density and promotes natural thermal convection. This specific variant is the \"Non-HART\" version, providing a cost-effective solution for control loops where digital field device diagnostics are not required, while maintaining the rugged G3-level environmental protection standard in Honeywell's premium I\/O line.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate seamlessly into the Experion PKS architecture, focusing on signal stability and hardware longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Density\u003c\/strong\u003e: Provides 16 independent analog output channels, allowing for high-density I\/O configurations in a small physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Architecture\u003c\/strong\u003e: Designed to be \"plug-and-play\" with Series 8 IOTAs (Input Output Termination Assemblies), supporting both non-redundant and redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The module is factory-treated with a conformal coating to protect internal circuitry against humidity and corrosive atmospheric contaminants (ISA S71.04 Class G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Features robust isolation between the I\/O Link (backplane) and the field-side electronics, preventing ground loops and protecting the C300 processor from field electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Loop Response\u003c\/strong\u003e: Optimized for low-latency signal delivery, ensuring that control valve movements are synchronized with the DCS PID logic for stable process modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e12-bit Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e5.5 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e15.00 x 10.00 x 4.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-PAONA2 be used to communicate with HART-enabled valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 8C-PAONA2 can drive a HART-enabled valve positioner using a standard 4-20 mA signal, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecannot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eread or write digital HART data. For full HART pass-through and diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule must be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle a loss of communication with the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAONA2 features a configurable \"Fail-Safe\" state. In the event of an I\/O Link failure or controller shutdown, each channel can be programmed to Hold Last Value (HLV) or go to a pre-defined safe value (e.g., 0 mA or 4 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older Series A or Series C IOTAs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-PAONA2 is strictly a Series 8 module and must be mounted on a Series 8 IOTA, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Single) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Redundant).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the total loop resistance (including field wiring and the actuator\/positioner impedance) does not exceed the module's maximum drive capability, typically 600 Ohms at 24 VDC. Exceeding this limit will result in \"Output Low\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). When replacing a module in a redundant pair, ensure the \"Secondary\" LED is stable before removing the \"Primary\" module to ensure a bumpless transfer of control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable for all 16 channels. The shield should be grounded at the IOTA's grounding bar. Proper shielding is critical to prevent electromagnetic interference (EMI) from inducing \"jitter\" in the 4-20 mA output signal, which can lead to premature mechanical wear on valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035236203,"sku":"8C-PAONA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona2-dcs-backplane-nkoilvcvcx2_ef231f8b-558f-431c-9001-1acf9869e5f7.jpg?v=1765505367"},{"product_id":"honeywell-experion-pks-8c-tdodb1-digital-output-redundant-iota","title":"Honeywell Experion PKS 8C-TDODB1 Digital Output Redundant IOTA","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHoneywell 8C-TDODB1 (8CTDODB1)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"Redundant\" IOTA is a critical infrastructure component that allows two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output modules to operate in a 1-out-of-2 (1oo2) configuration.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn this setup,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe primary and secondary modules work in tandem; if the primary module fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module takes over control of the field devices instantaneously without a \"bump\" in the process.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in sectors requiring mission-critical safety and uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as Emergency Shutdown (ESD) systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eturbine trip circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand critical solenoid header controls in chemical and power plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide a robust physical and electrical foundation for redundant digital control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Module Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two dedicated slots for Digital Output modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging the synchronization and load-sharing logic between the two units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e32-Channel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 individual digital output channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypically used for driving 24 VDC solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erelays,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor indicator lamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-treated with a protective layer to ensure long-term reliability in environments with high humidity or corrosive gas concentrations (conforming to ISA G3 standards).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVertical I\/O Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the Series 8 vertical mounting format,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich promotes natural airflow for cooling and reduces the overall footprint within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Blown Fuse Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides circuit protection and diagnostic feedback to the C300 controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing operators to identify field-side wiring faults or short circuits immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use only one module on the 8C-TDODB1 IOTA?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 8C-TDODB1 is designed for redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit can operate with a single module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system will report a \"Redundancy Lost\" alarm until the second module is installed and synchronized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the difference between 8C-TDODA1 and 8C-TDODB1?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 8C-TDODA1 is a \"Single\" IOTA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting only one module with no hardware redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Redundant\" version,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing two module slots for high-availability applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this IOTA provide power to the field solenoids?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IOTA distributes 24 VDC power from the cabinet busbar to the outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe total current capacity is limited per channel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-current solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einterposing relays should be used to protect the IOTA circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Cable Installation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the redundancy link between the two modules is securely seated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithout this link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe modules cannot synchronize their internal states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eleading to independent operation and potential control conflicts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e When wiring the 32 channels,\u003c\/span\u003e\u003cspan\u003e use ferrules to prevent stray wire strands from causing short circuits between adjacent terminals.\u003c\/span\u003e\u003cspan\u003e Given the high density of the 8C-TDODB1,\u003c\/span\u003e\u003cspan\u003e cable management and clear labeling are essential for future troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e The IOTA must be bonded to the instrument earth bar via the carrier's grounding system.\u003c\/span\u003e\u003cspan\u003e Proper grounding is vital for the correct operation of the blown-fuse detection circuitry and to prevent electromagnetic noise from affecting the I\/O Link communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035662187,"sku":"8C-TDODB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdodb1-digital-output-module-nto0msgjdle_0be4d2d8-53a4-4ee4-9ea3-94936ec0e1b4.jpg?v=1765505373"},{"product_id":"honeywell-experion-pks-8c-taoxa1-51307135-175-analog-output-iota","title":"Honeywell Experion PKS 8C-TAOXA1 (51307135-175) Analog Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Analog Output Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. As a fundamental component of the C300 control environment, this IOTA provides the physical mounting base and field wiring interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output module. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support 16 channels of 4-20 mA signals, commonly used to drive control valves, actuators, and speed governors in critical process industries such as oil and gas, power generation, and pharmaceutical manufacturing. Its vertical form factor is a signature of the Series 8 design, engineered to promote natural convection cooling and minimize the footprint within high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for rapid installation and long-term signal integrity in demanding industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Provides dedicated screw terminal points for 16 analog output loops, supporting both redundant and non-redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting Profile\u003c\/strong\u003e: Specifically designed for the Series 8 Slim chassis, allowing for efficient cable management and superior thermal dissipation compared to traditional horizontal racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51307135-175 variant is factory-treated with a protective coating to withstand Class G3 harsh environments, preventing corrosion from H2S, Cl2, and other caustic gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Distribution\u003c\/strong\u003e: Manages the distribution of 24 VDC power from the cabinet bus to the inserted I\/O module and the field-side loop, ensuring consistent drive current across all 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Interface\u003c\/strong\u003e: Features robust, high-density compression terminals that facilitate secure connections for field cabling, with integrated support for shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TAOXA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307135-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (16-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAOXA1 \/ 8C-PAOYA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-TAOXA1 compatible with HART communication modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the IOTA is a passive termination assembly, it is designed to transparently pass HART digital data when paired with an Analog Output module that supports HART (such as the 8C-PAOHA1).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51307135-175 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 175 suffix specifically denotes the G3 conformal coating. Standard, non-coated versions carry different suffixes. This version is required for any installation where the control room atmosphere is not strictly regulated for corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA for redundant AO module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-TAOXA1 is a non-redundant (Single) IOTA. For redundant applications where two modules back up one another on the same field wiring, you must use the redundant version of the IOTA (8C-TAOXB1).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Discipline\u003c\/strong\u003e: When connecting 4-20 mA loops to the 8C-TAOXA1, ensure that signal cables are kept separate from high-voltage AC lines. Use twisted-pair shielded cables and terminate the shield at the IOTA designated ground point to minimize electromagnetic interference (EMI) that can cause valve hunting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Before applying power, ensure the 8C-PAOXA1 module is fully seated onto the IOTA and the captive mounting screws are tightened. A loose module can cause intermittent Channel Fault or I\/O Link Failure alarms in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e: Since this is the 51307135-175 G3-coated version, ensure that when field wiring is completed, the cabinet entries are sealed. The coating protects the board, but terminal connections remain vulnerable to heavy oxidation if the cabinet is left open in a corrosive environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668040085867,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-analog-output-module-ee5lfji1kt3_bed50637-0f91-47a7-be5b-ee3622df234d.jpg?v=1765505433"},{"product_id":"bently-nevada-3500-60-133827-01-3500-series-rtd-tc-non-isolated-i-o-module-external-terminations","title":"Bently Nevada 3500\/60 133827-01 โมดูล I\/O แบบไม่แยกสำหรับ RTD\/TC ซีรีส์ 3500 พร้อมขั้วต่อภายนอก","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการรวมเข้ากับระบบป้องกันเครื่องจักร 3500 \u003cstrong\u003e3500\/60 133827-01\u003c\/strong\u003e ทำหน้าที่เป็นอินเทอร์เฟซอินพุต\/เอาต์พุตการตรวจสอบอุณหภูมิที่เชี่ยวชาญ โมดูลนี้ถูกกำหนดค่าเฉพาะเป็นโมดูล I\/O แบบไม่แยกวงจร RTD\/TC ที่เหมาะสมกับสถาปัตยกรรมเทอร์มินัลภายนอก (ET) โดยการเดินสัญญาณภาคสนามผ่านบล็อกเทอร์มินัลภายนอก จะให้อินเทอร์เฟซความหนาแน่นสูงที่ดูแลรักษาง่ายสำหรับอินพุตเซ็นเซอร์อุณหภูมิเครื่องจักรที่สำคัญ\u003c\/p\u003e\n\n\u003cp\u003eฟังก์ชัน \u003cstrong\u003e133827-01\u003c\/strong\u003e เชื่อมต่อโดยตรงกับ Resistance Temperature Detectors (RTDs) และ Thermocouples (TCs) เพื่อตรวจสอบโปรไฟล์อุณหภูมิบนเครื่องจักรอุตสาหกรรมมูลค่าสูง ฮาร์ดแวร์จริงจะประมวลผลสัญญาณเซ็นเซอร์ดิบเหล่านี้และส่งข้อมูลดิจิทัลไปยังโมดูลตรวจสอบอุณหภูมิ 3500\/60 หลัก ช่วยให้การปกป้องทรัพย์สินอย่างต่อเนื่อง การสร้างสถานะสัญญาณเตือน และการรวมตรรกะการตัดเครื่องจักร\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eรับสัญญาณตรงจากเซ็นเซอร์ Thermocouple (TC) และ Resistance Temperature Detector (RTD) มาตรฐาน\u003c\/li\u003e\n  \u003cli\u003eสถาปัตยกรรมวงจรที่ไม่แยกวงจรออกแบบมาเพื่อเพิ่มประสิทธิภาพเส้นทางการประมวลผลสัญญาณ\u003c\/li\u003e\n  \u003cli\u003eรองรับบล็อกเทอร์มินัลภายนอก (ET) เพื่อลดความซับซ้อนของการเดินสายในตู้และทำให้การบำรุงรักษาภาคสนามง่ายขึ้น\u003c\/li\u003e\n  \u003cli\u003eเข้ากันได้อย่างสมบูรณ์กับแบ็คเพลนและส่วนประกอบการตรวจสอบมาตรฐานของชุด 3500\u003c\/li\u003e\n  \u003cli\u003eการออกแบบฮาร์ดแวร์แบบถอดเปลี่ยนร้อนช่วยให้สามารถเปลี่ยนโมดูลได้โดยไม่ต้องปิดระบบป้องกันทั้งหมด โดยขึ้นอยู่กับขั้นตอนความปลอดภัยของไซต์\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eการตรวจสอบอุณหภูมิแบริ่งและสเตเตอร์ของกังหันไอน้ำและกังหันแก๊สในอุตสาหกรรม\u003c\/li\u003e\n  \u003cli\u003eการวินิจฉัยตัวเรือนคอมเพรสเซอร์และปั๊มความจุสูง\u003c\/li\u003e\n  \u003cli\u003eการตรวจสอบอุณหภูมิของมอเตอร์ไฟฟ้าและขดลวดเครื่องกำเนิดไฟฟ้าขนาดใหญ่\u003c\/li\u003e\n  \u003cli\u003eวงจรป้องกันอุณหภูมิท่อกระบวนการสำคัญและเครื่องแลกเปลี่ยนความร้อน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n    \u003cth\u003eข้อกำหนด\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\/รุ่น\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3500\/60 133827-01\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eชุดระบบ\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eโมดูล I\/O แบบไม่แยกวงจร RTD\/TC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eประเภทเทอร์มินัล\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eเทอร์มินัลภายนอก (ET)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eประเทศผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eน้ำหนักสุทธิ\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.45 กก.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eน้ำหนักจัดส่ง\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3.00 กก.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eอินเทอร์เฟซการเชื่อมต่อ\u003c\/th\u003e\n    \u003cth\u003eคำอธิบายการทำงาน\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eตัวเชื่อมต่อแบ็คเพลน\u003c\/td\u003e\n    \u003ctd\u003eตัวเชื่อมต่อแบ็คเพลนแบบหลายพินเฉพาะของ 3500 สำหรับการสื่อสารดิจิทัลความเร็วสูงและการจ่ายพลังงาน\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eพอร์ตเทอร์มินัล I\/O ภายนอก\u003c\/td\u003e\n    \u003ctd\u003eพอร์ตอินเทอร์เฟซเฉพาะที่ออกแบบมาเพื่อเชื่อมต่อสายเคเบิลหลายตัวนำที่ยืดไปยังบล็อกเทอร์มินัลภายนอก\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าโมดูลติดตั้งในช่อง I\/O ด้านหลังที่ตรงกับโมดูลตรวจสอบอุณหภูมิ 3500\/60 ด้านหน้าโดยตรง\u003c\/li\u003e\n  \u003cli\u003eเมื่อเดินสายเคเบิลเทอร์มินัลภายนอก ให้รักษาระยะห่างทางกายภาพที่เพียงพอจากสายไฟแรงดันสูงเพื่อป้องกันการรบกวนทางแม่เหล็กไฟฟ้า\u003c\/li\u003e\n  \u003cli\u003eเนื่องจากโมดูลนี้ใช้สถาปัตยกรรมที่ไม่แยกวงจร การปฏิบัติตามข้อกำหนดการต่อสายกราวด์ของระบบที่บล็อกเทอร์มินัลภายนอกอย่างเคร่งครัดจึงมีความสำคัญเพื่อหลีกเลี่ยงข้อผิดพลาดวงจรกราวด์ลูป\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าสายเซ็นเซอร์ทั้งหมดตรงกับการกำหนดค่า RTD หรือ Thermocouple ที่โปรแกรมไว้ในซอฟต์แวร์กำหนดค่า 3500\/60\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668278210923,"sku":"3500\/60 133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350060133827-01-aobwipssfrf_bebbdf72-46f5-4992-b1f2-0c48dbf4ce31.jpg?v=1765520323"},{"product_id":"bently-nevada-163179-03-3500-series-process-monitor-i-o-module","title":"โมดูลอินพุต\/เอาต์พุตสำหรับเครื่องมือตรวจสอบกระบวนการรุ่น 3500 Bently Nevada 163179-03","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อรวมเข้ากับระบบป้องกันเครื่องจักร 3500   \u003cstrong\u003e163179-03\u003c\/strong\u003e โมดูลอินพุต\/เอาต์พุตเฉพาะที่เชื่อมต่อโดยตรงกับ 3500\/62 Process Monitor โมดูลรุ่นนี้ออกแบบมาพร้อมแผงกั้นความปลอดภัยภายในและการต่อสายภายใน ทำให้สามารถเชื่อมต่อโดยตรงกับเซ็นเซอร์และตัวส่งสัญญาณภาคสนามในสภาพแวดล้อมอันตรายโดยไม่ต้องใช้แผงกั้นภายนอกเสริม  \u003c\/p\u003e\n\n\u003cp\u003eคือ   \u003cstrong\u003e163179-03\u003c\/strong\u003e ทำงานโดยรับสัญญาณอนาล็อกจากอุตสาหกรรม เช่น อินพุตกระแสไฟฟ้า 4 ถึง 20 mA DC หรือแรงดันไฟฟ้าสัดส่วน และส่งต่อไปยังโมดูลตรวจสอบหลัก 3500\/62 เพื่อแปลงสัญญาณเป็นดิจิทัล ประมวลผล และเปรียบเทียบกับค่าตั้งเตือน ช่วยให้สามารถเฝ้าระวังตัวแปรกระบวนการสำคัญอย่างต่อเนื่อง เช่น ความดัน อุณหภูมิ ระดับ การไหล และความเข้มข้นของแก๊สในเครื่องจักรหมุนและระบบโรงงานที่สำคัญ  \u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eเข้ากันได้โดยตรงกับบอร์ดหลัก Bently Nevada 3500\/62 Process Monitor  \u003c\/li\u003e\n  \u003cli\u003eแผงกั้นความปลอดภัยภายในแบบบูรณาการช่วยขจัดความจำเป็นในการใช้ฮาร์ดแวร์ป้องกันการระเบิดภายนอก  \u003c\/li\u003e\n  \u003cli\u003eบล็อกการต่อสายภายในรองรับการเชื่อมต่อสายไฟภาคสนามที่ปลอดภัยและถาวร  \u003c\/li\u003e\n  \u003cli\u003eรองรับอินพุตตัวส่งสัญญาณตัวแปรกระบวนการ 6 ช่องสัญญาณอิสระ  \u003c\/li\u003e\n  \u003cli\u003eโครงสร้างแข็งแรงออกแบบมาเพื่อความน่าเชื่อถือสูงในสภาพแวดล้อมระบบอัตโนมัติอุตสาหกรรม  \u003c\/li\u003e\n  \u003cli\u003eปรับแต่งได้เต็มที่ผ่านซอฟต์แวร์การกำหนดค่าชั้นวางมาตรฐาน 3500  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eการป้องกันเครื่องจักรและการตรวจสอบสภาพในอุตสาหกรรมปิโตรเคมีและการกลั่นน้ำมัน \u0026 แก๊ส  \u003c\/li\u003e\n  \u003cli\u003eการควบคุมตัวแปรกระบวนการไอน้ำ แก๊ส และไฮโดรไดนามิกในสถานีผลิตไฟฟ้า  \u003c\/li\u003e\n  \u003cli\u003eการตรวจสอบกระบวนการโรงงานบำบัดน้ำเสียอุตสาหกรรม  \u003c\/li\u003e\n  \u003cli\u003eการตรวจสอบอย่างต่อเนื่องของความดัน การไหล และระดับในกระบวนการผลิตเคมีภัณฑ์\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eผู้ผลิต  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน \/ รุ่น  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e163179-03\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eชื่อชุด  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eระบบป้องกันเครื่องจักรชุด 3500  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eโมดูลมอนิเตอร์ที่เข้ากันได้  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eเครื่องมอนิเตอร์กระบวนการ 3500\/62  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเภทการสิ้นสุด  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eการสิ้นสุดภายใน  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eการกำหนดค่าอุปสรรค  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eอุปสรรคความปลอดภัยภายใน (ปลอดภัยโดยเนื้อแท้)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eจำนวนช่องสัญญาณ  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 ช่องสัญญาณแบบต่างศักย์หรือแบบปลายเดียว  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eรูปแบบสัญญาณอินพุต  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 ถึง 20 mA DC, +1 ถึง +5 VDC (สัดส่วน)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eอุณหภูมิการทำงาน  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eอุณหภูมิการเก็บรักษา  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eความชื้นสัมพัทธ์  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eความชื้นสัมพัทธ์ 95% ไม่ควบแน่น  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเทศต้นทาง  \u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eสหรัฐอเมริกา  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ  \u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eกลุ่มการเชื่อมต่อเทอร์มินัล  \u003c\/th\u003e\n      \u003cth\u003eคำอธิบายฟังก์ชัน  \u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eช่อง 1 ถึง 6  \u003c\/td\u003e\n      \u003ctd\u003eขั้วต่ออินพุตเครื่องส่งสัญญาณกระบวนการ (สัญญาณ, ร่วม, ชิลด์)  \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eกราวด์อุปสรรคภายใน  \u003c\/td\u003e\n      \u003ctd\u003eการเชื่อมต่อเฉพาะสำหรับการอ้างอิงกราวด์ความปลอดภัยโดยเนื้อแท้  \u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eปิดเครื่องแร็ค 3500 ก่อนติดตั้งหรือถอดโมดูล I\/O รุ่น 163179-03 เพื่อป้องกันความผิดพลาดของระบบหรือความเสียหายของฮาร์ดแวร์  \u003c\/li\u003e\n  \u003cli\u003eใส่โมดูลลงในช่องที่กำหนดบนแผงด้านหลังของแร็ค โดยตรงด้านหลังการ์ดมอนิเตอร์ 3500\/62 ที่สอดคล้องกัน  \u003c\/li\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าการเชื่อมต่อกราวด์ของโครงเครื่องและกราวด์ของอุปสรรคความปลอดภัยภายในเชื่อมต่อกับกราวด์โลกที่มีความสมบูรณ์สูงและความต้านทานต่ำ  \u003c\/li\u003e\n  \u003cli\u003eปฏิบัติตามแนวทางแรงบิดที่ระบุสำหรับสกรูเทอร์มินัลเพื่อป้องกันการเชื่อมต่อสายไฟภาคสนามหลวมภายใต้สภาวะการสั่นสะเทือน  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการปฏิบัติตามและการรับรอง  \u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eเป็นไปตามมาตรฐาน CE  \u003c\/li\u003e\n  \u003cli\u003eUL\/CSA ชั้น I, แผนก 2 \/ แผนก 1 (เมื่อใช้งานร่วมกับอุปสรรคที่เหมาะสม)  \u003c\/li\u003e\n  \u003cli\u003eATEX \/ IECEx ปลอดภัยโดยเนื้อแท้สำหรับสภาพแวดล้อมโซน 0\/โซน 1  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298133867,"sku":"163179-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/163179-03-brp2zhgahwh_48c65830-ef12-4137-9446-6349e064224d.jpg?v=1765520471"},{"product_id":"bently-nevada-172103-01-3500-65-rtd-isolated-tip-tc-i-o-module","title":"โมดูลอินพุต\/เอาต์พุต Bently Nevada 172103-01 3500\/65 RTD\/Isolated Tip TC","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e172103-01\u003c\/strong\u003e เป็นโมดูลอินพุต\/เอาต์พุตตรวจวัดอุณหภูมิ 16 ช่องที่ออกแบบมาสำหรับแร็คระบบป้องกันเครื่องจักร 3500\/65 ให้การเชื่อมต่อทางกายภาพสำหรับตัวตรวจจับอุณหภูมิแบบความต้านทาน (RTD) และเทอร์โมคัปเปิลแบบปลายแยก (TC) โมดูลมีการต่อสายภายใน ทำให้สายไฟจากเซ็นเซอร์อุณหภูมิสามารถเชื่อมต่อโดยตรงกับบล็อกเทอร์มินัลด้านหลังแร็ค 3500 โดยไม่ต้องใช้บล็อกต่อสายภายนอก\u003c\/p\u003e\n\u003cp\u003eโมดูล I\/O นี้เชื่อมต่อโดยตรงกับโมดูลมอนิเตอร์ 3500\/65 เพื่อปรับสภาพข้อมูลอุณหภูมิที่เก็บตัวอย่างอย่างต่อเนื่อง ใช้เป็นหลักในงานเครื่องจักรที่สำคัญ รวมถึงแบริ่งของกังหันไอน้ำและกังหันแก๊ส ขดลวดสเตเตอร์มอเตอร์ขนาดใหญ่ ท่อระบายอัดของคอมเพรสเซอร์ และการตรวจสอบตัวเครื่องปั๊มอุตสาหกรรม โมดูลนี้รองรับการตรวจสอบสัญญาณเตือนอย่างต่อเนื่องและการรวมตรรกะการตัดเครื่องจักรเมื่อใช้ร่วมกับโมดูลรีเลย์ระบบ 3500\u003c\/p\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eหมายเลขชิ้นส่วน:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e172103-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eผู้ผลิต:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eความเข้ากันได้กับมอนิเตอร์:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eมอนิเตอร์อุณหภูมิ 3500\/65 16 ช่อง\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eประเภทการต่อสาย:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eการต่อสายภายใน (รวมปลั๊กเทอร์มินัล 20 พิน หมายเลขชิ้นส่วน 173005)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eกลุ่มฟังก์ชัน:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eอะไหล่ระบบป้องกันเครื่องจักร\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable class=\"NRefec\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cZCYO firstRow\"\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth class=\"iry6k\" colspan=\"undefined\"\u003eข้อกำหนด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eรุ่น\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e172103-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eแบรนด์\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eประเภทสินค้า\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eโมดูลอินพุต\/เอาต์พุตตรวจวัดอุณหภูมิ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eซีรีส์\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eซีรีส์ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eช่องอินพุต\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e16 ช่องอิสระ (RTD หรือ Isolated Tip TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eความต้านทานอินพุต\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003e 1 MΩ ที่อินพุตทรานสดิวเซอร์ทั้งหมด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eกระแสจ่าย\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eแหล่งจ่ายกระแสคงที่ 913 μA ± 7 μA ต่อช่อง RTD (ที่ 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eความละเอียด\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e1°C หรือ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eความแม่นยำในการวัด\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e± 3°C (± 5.4°F) ที่อุณหภูมิแวดล้อม +25°C (รวมการชดเชยจุดเย็นภายใน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eการใช้พลังงาน\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eกำลังไฟสูงสุด 3.0 วัตต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eขนาด (สูง x กว้าง x ลึก)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e241.3 มม. x 24.4 มม. x 99.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 3.90 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eน้ำหนัก\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0.45 กก. (1.0 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eอุณหภูมิการทำงาน\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-30°C ถึง +65°C (-22°F ถึง +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eอุณหภูมิการเก็บรักษา\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e-40°C ถึง +85°C (-40°F ถึง +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eความชื้น\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e0% ถึง 95% ความชื้นสัมพัทธ์ ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eระดับการป้องกัน\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eIP20 (เมื่อติดตั้งในชาสซี 3500 มาตรฐาน)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cZCYO\"\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003e\u003cspan class=\"Yjhzub\"\u003eประเทศต้นทาง\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"cOeeGf\" colspan=\"undefined\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eการกำหนดค่าฮาร์ดแวร์และความเข้ากันได้ของเซ็นเซอร์\u003c\/h3\u003e\n\u003cp\u003eโมดูล 172103-01 รองรับการกำหนดค่าผสมของเทอร์โมคัปเปิลและ RTD ภายในซอฟต์แวร์กำหนดค่าแร็ค 3500 ช่วงเซ็นเซอร์ที่รองรับมีรายละเอียดดังนี้:\u003c\/p\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eเทอร์โมคัปเปิลชนิด E (ปลายแยก):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-100°C ถึง +1000°C (-148°F ถึง +1832°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eเทอร์โมคัปเปิลชนิด J (ปลายแยก):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C ถึง +760°C (32°F ถึง +1400°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eเทอร์โมคัปเปิลชนิด K (ปลายแยก):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0°C ถึง +1370°C (32°F ถึง +2498°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eเทอร์โมคัปเปิลชนิด T (ปลายแยก):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-160°C ถึง +400°C (-256°F ถึง +752°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eRTD แพลทินัม 100 Ω (Pt100, alpha = 0.00385):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C ถึง +850°C (-328°F ถึง +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eRTD แพลทินัม 100 Ω (Pt100, alpha = 0.00392):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C ถึง +850°C (-328°F ถึง +1562°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eRTD นิกเกิล 120 Ω (Ni120):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-200°C ถึง +700°C (-328°F ถึง +1292°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eRTD ทองแดง 10 Ω (Cu10):\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e-80°C ถึง +260°C (-112°F ถึง +500°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคู่มือวิศวกรรมและการติดตั้ง\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eการกราวด์และการป้องกัน:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eสายป้องกันของเซ็นเซอร์อุณหภูมิต้องต่อที่จุดเดียว เชื่อมต่อสายป้องกันกับเทอร์มินัลกราวด์ชาสซีเฉพาะบนแร็ค 3500 ห้ามกราวด์สายป้องกันทั้งที่ปลายเซ็นเซอร์และปลายโมดูลเพื่อป้องกันวงจรกราวด์ลูป\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eข้อจำกัดของเทอร์โมคัปเปิล:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eใช้ได้เฉพาะเทอร์โมคัปเปิลปลายแยกเท่านั้นกับ 172103-01 ห้ามใช้เทอร์โมคัปเปิลปลายกราวด์ เพราะจะทำให้เกิดข้อผิดพลาดแรงดันโหมดทั่วไปในช่องที่ใช้วงจรมัลติเพล็กเซอร์อินพุตเดียวกัน\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eการแยกสายไฟ:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eเดินสายสัญญาณ RTD\/TC แรงดันต่ำผ่านถาดสายไฟแยกเฉพาะ หลีกเลี่ยงการวางใกล้สายไฟมอเตอร์แรงดันสูง, เอาต์พุตตัวขับความถี่แปรผัน (VFD) หรือโหลดเหนี่ยวนำสวิตชิ่ง เพื่อป้องกันการรบกวนแม่เหล็กไฟฟ้า (EMI)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eการดัดแปลง RTD 4 สาย:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eโมดูลเทอร์มินัลภายในมาตรฐานถูกตั้งค่าสำหรับการชดเชย RTD 3 สาย หากใช้เซ็นเซอร์ RTD 4 สาย ให้ตรวจสอบรหัสการดัดแปลงฮาร์ดแวร์เฉพาะ (เช่น การดัดแปลง 179952-01) ที่จำเป็นสำหรับการรองรับการต่อสายหลายเส้นทางกายภาพ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eข้อควรระวังในการสลับโมดูลขณะเปิดเครื่อง:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eแม้ว่าการ์ดมอนิเตอร์หลัก 3500\/65 จะรองรับการถอด\/ใส่โมดูลออนไลน์ แต่การถอดโมดูล I\/O 172103-01 ขณะมอนิเตอร์ทำงานจะทำให้วงจรเซ็นเซอร์ขัดข้องทันที ก่อให้เกิดข้อผิดพลาดของช่องและอาจทำให้เกิดสัญญาณเตือนอันตรายระดับแร็ค ควรข้ามตรรกะโหวตหรือการล็อกปิดที่เกี่ยวข้องก่อนถอดโมดูล\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eคำถามที่พบบ่อยทางเทคนิค\u003c\/h3\u003e\n\u003cul class=\"KsbFXc U6u95 list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eสามารถใช้โมดูล 172103-01 กับบล็อกเทอร์มินัลภายนอกได้หรือไม่?\u003c\/span\u003e\u003cbr\u003eไม่ใช่ 172103-01 ถูกออกแบบมาเฉพาะสำหรับการต่อภายในที่สายไฟภาคสนามเชื่อมต่อโดยตรงกับปลั๊กแผงหลังของแร็ค สำหรับบล็อกเทอร์มินัลภายนอก ต้องสั่งโมดูล I\/O เทอร์มินัลภายนอก 172109-01 แทน\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eจะเกิดอะไรขึ้นถ้าสายเซ็นเซอร์อุณหภูมิขาดหรือหลุดออก?\u003c\/span\u003e\u003cbr\u003eมอนิเตอร์ 3500\/65 จะทำการตรวจสอบขีดจำกัดของทรานสดิวเซอร์โดยอัตโนมัติ หากสายไฟขาดจะทำให้สถานะเป็น \"Open Circuit\" หรือ \"Not OK\" สำหรับช่องนั้นๆ ไฟ LED ช่อง OK บนการ์ดหลักด้านหน้า จะกระพริบ และสถานะเอาต์พุตของช่องนั้นจะถูกขับออกนอกช่วงเพื่อป้องกันการทริปเครื่องที่ผิดพลาด\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eจำเป็นต้องอัปเดตเฟิร์มแวร์เมื่อเปลี่ยนโมดูล I\/O รุ่นเก่า Revision กับ 172103-01 ใหม่หรือไม่?\u003c\/span\u003e\u003cbr\u003eหากอัปเกรดหรือเปลี่ยนแปลงการตั้งค่าเก่า ให้ตรวจสอบว่าเวอร์ชันเฟิร์มแวร์ของการ์ดมอนิเตอร์หลัก 3500\/65 เข้ากันได้หรือไม่ เฟิร์มแวร์ที่ไม่เข้ากันอาจทำให้เกิดความไม่ตรงกันของการตั้งค่าหรือข้อผิดพลาด \"Configuration Error\" ต่อเนื่องในบันทึกเหตุการณ์ของแร็ค\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"T286Pc\"\u003e\u003cspan class=\"Yjhzub\"\u003eการชดเชยจุดต่อเย็น (CJC) สำหรับเทอร์โมคัปเปิลจัดการอย่างไร?\u003c\/span\u003e\u003cbr\u003e172103-01 มาพร้อมกับเซ็นเซอร์วัดอุณหภูมิแบบโซลิดสเตตที่ติดตั้งโดยตรงบนแผงวงจรบล็อกเทอร์มินัล เซ็นเซอร์นี้ติดตามการเปลี่ยนแปลงของอุณหภูมิที่เทอร์มินัลและใช้ปัจจัยชดเชยดิจิทัลภายในชั้นประมวลผลของมอนิเตอร์ 3500\/65\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668298625387,"sku":"172103-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/172103-01-hymuxx01gcp_f9bd0daa-d3f3-4d15-819b-972e3ef918b5.jpg?v=1765520488"},{"product_id":"bently-nevada-3500-61-05-cn-3500-61-temperature-module-with-recorder-outputs","title":"Bently Nevada 3500\/61-05-CN 3500\/61 โมดูลวัดอุณหภูมิกับเอาต์พุตเครื่องบันทึก","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61-05-CN\u003c\/strong\u003e เป็นโมดูลเครื่องมือวัดสูงเต็ม 6 ช่องที่ออกแบบมาเพื่อให้การตรวจสอบอุณหภูมิอย่างต่อเนื่องและสัญญาณอนาล็อกสัดส่วนที่แม่นยำภายใน \u003cstrong\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/strong\u003e โมดูลเฉพาะนี้รับสัญญาณดิบจากเครื่องตรวจจับอุณหภูมิแบบความต้านทาน (RTD) และเทอร์โมคัปเปิล (TC) ปรับสัญญาณ และประเมินข้อมูลเทียบกับเกณฑ์สัญญาณเตือน Alert และ Danger ที่ตั้งโปรแกรมโดยผู้ใช้ แตกต่างจากโมดูลคู่ขนาน โมดูลนี้มีเอาต์พุตเครื่องบันทึก +4 ถึง +20 mA แยกอิสระสำหรับแต่ละช่องทั้ง 6 ช่อง ทำให้สามารถรวมเข้ากับระบบควบคุมแบบกระจาย (DCS), เครื่องบันทึกแถบ หรือเครื่องบันทึกข้อมูลทั่วโรงงานได้อย่างราบรื่น ทำงานภายในกรอบแร็ค 3500 มาตรฐาน รองรับการตั้งค่าภาคสนามผ่านซอฟต์แวร์ตั้งค่าแร็ค 3500 และรองรับการออกแบบที่ไม่แยกวงจรโดยมีอุปสรรคความปลอดภัยภายในเพื่อรักษาความสมบูรณ์ของวงจรในสภาพแวดล้อมเครื่องจักรอุตสาหกรรมที่หลากหลาย\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eช่องตรวจสอบอุณหภูมิครบถ้วน 6 ช่อง รองรับการผสมผสานเซ็นเซอร์ RTD และเทอร์โมคัปเปิล\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตเครื่องบันทึกอนาล็อก +4 ถึง +20 mA เฉพาะช่องสัญญาณแต่ละช่อง สัดส่วนกับค่ามอนิเตอร์สเกลเต็ม และไม่ถูกรบกวนจากวงจรลัดวงจรภายนอก\u003c\/li\u003e\n\u003cli\u003eจุดตั้งค่า Alert และ Danger ที่ตั้งโปรแกรมได้ในซอฟต์แวร์ ครอบคลุม 0 ถึง 100% ของสเกลเซ็นเซอร์ที่ใช้งาน\u003c\/li\u003e\n\u003cli\u003eการตั้งเวลาหน่วงสัญญาณเตือนที่ปรับได้ตั้งแต่ 1 ถึง 60 วินาที เพื่อลดการตัดสัญญาณชั่วคราว\u003c\/li\u003e\n\u003cli\u003eไฟ LED วินิจฉัยบนแผงหน้าปัดที่ให้การประเมินสถานะทันทีสำหรับโมดูล OK, โหมดบายพาส และการสื่อสารบัส TX\/RX ที่ใช้งานอยู่\u003c\/li\u003e\n\u003cli\u003eรองรับสถาปัตยกรรม I\/O ที่ไม่แยกวงจรโดยมีอุปสรรคความปลอดภัยภายในเพื่อปกป้องวงจรประมวลผลที่ละเอียดอ่อน\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการติดตามความร้อนอย่างต่อเนื่องของขดลวดสเตเตอร์มอเตอร์และเครื่องกำเนิดไฟฟ้าอุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบอุณหภูมิแบริ่งรัศมีและแรงดันบนเครื่องจักรหมุนที่สำคัญ, ปั๊ม และคอมเพรสเซอร์อุตสาหกรรม\u003c\/li\u003e\n\u003cli\u003eการบันทึกอุณหภูมิแก๊สไอเสียสำหรับกังหันแก๊สและเครื่องจักรหนักในกระบวนการ\u003c\/li\u003e\n\u003cli\u003eการรวมตรรกะการโหวตอุณหภูมิหลายช่องสัญญาณสำหรับระบบตัดเครื่องจักรอัตโนมัติ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมวดหมู่\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อกำหนด\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eข้อมูล\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟฟ้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการใช้พลังงาน\u003c\/td\u003e\n\u003ctd\u003e9 วัตต์ โดยประมาณ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความจุสัญญาณขาเข้า\u003c\/td\u003e\n\u003ctd\u003eสัญญาณทรานสดิวเซอร์ RTD หรือ TC 1 ถึง 6 ช่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความต้านทานขาเข้า\u003c\/td\u003e\n\u003ctd\u003e10 เมกะโอห์ม สำหรับแต่ละขั้วนำเข้า\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eค่ากระแสแหล่งจ่าย RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 ไมโครแอมป์ @ 25 องศาเซลเซียส ต่อทรานสดิวเซอร์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเอาต์พุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสัญญาณเอาต์พุตของเครื่องบันทึก\u003c\/td\u003e\n\u003ctd\u003e+4 ถึง +20 mA DC (สัดส่วนกับสเกลเต็ม)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eช่วงแรงดันไฟฟ้าสอดคล้อง\u003c\/td\u003e\n\u003ctd\u003e0 ถึง +12 Vdc ข้ามโหลด\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eช่วงความต้านทานโหลด\u003c\/td\u003e\n\u003ctd\u003e0 ถึง 600 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความละเอียดของเครื่องบันทึก\u003c\/td\u003e\n\u003ctd\u003e0.3662 ไมโครแอมป์ต่อบิต\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eข้อผิดพลาดของเครื่องบันทึก\u003c\/td\u003e\n\u003ctd\u003e+\/-0.15% ที่อุณหภูมิห้อง, +\/-0.4% ในช่วงอุณหภูมิ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประสิทธิภาพ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eช่วงจุดตั้งสัญญาณเตือน\u003c\/td\u003e\n\u003ctd\u003eปรับได้ตั้งแต่ 0 ถึง 100% ของสเกลเต็ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความแม่นยำของจุดตั้งสัญญาณเตือน\u003c\/td\u003e\n\u003ctd\u003eภายใน 0.13% ของค่าที่ต้องการ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eช่วงเวลาหน่วงการแจ้งเตือน\u003c\/td\u003e\n\u003ctd\u003e1 ถึง 60 วินาที โดยเพิ่มทีละ 1 วินาที\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eช่วงเวลาหน่วงอันตราย\u003c\/td\u003e\n\u003ctd\u003e1 ถึง 60 วินาที ในช่วง 0.5 วินาที\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความละเอียดอุณหภูมิ\u003c\/td\u003e\n\u003ctd\u003e1 องศาเซลเซียส หรือ 1 องศาฟาเรนไฮต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eสิ่งแวดล้อม\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอุณหภูมิการทำงาน (อุปสรรคภายใน)\u003c\/td\u003e\n\u003ctd\u003e0 องศาเซลเซียส ถึง +65 องศาเซลเซียส (32 องศาฟาเรนไฮต์ ถึง +150 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eช่วงอุณหภูมิการเก็บรักษา\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 องศาฟาเรนไฮต์ ถึง +185 องศาฟาเรนไฮต์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eความชื้นในการทำงานรอบข้าง\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์สูงสุด 95% ไม่ควบแน่น\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eกลไก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขนาดโมดูลหน้าจอ (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 241.8 มม. (9.50 นิ้ว x 0.96 นิ้ว x 9.52 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eน้ำหนักโมดูลหน้าจอ\u003c\/td\u003e\n\u003ctd\u003e0.91 กก. (2.0 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O พร้อมอุปสรรคภายใน (สูง x กว้าง x ลึก)\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 163.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 6.42 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eน้ำหนักโมดูล I\/O พร้อมอุปสรรคภายใน\u003c\/td\u003e\n\u003ctd\u003e0.46 กก. (1.01 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eข้อกำหนดพื้นที่แร็คด้านหน้า\u003c\/td\u003e\n\u003ctd\u003e1 ช่องด้านหน้เต็มความสูง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eข้อกำหนดพื้นที่แร็คด้านหลัง\u003c\/td\u003e\n\u003ctd\u003e1 ช่องด้านหลังเต็มความสูง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eเทอร์มินัล \/ อินเทอร์เฟซส่วนประกอบ\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eฟังก์ชัน\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED OK แผงด้านหน้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eแสดงเมื่อเครื่องตรวจวัดอุณหภูมิทำงานอย่างถูกต้อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED TX\/RX แผงด้านหน้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eกะพริบเพื่อแสดงการสื่อสารที่ใช้งานกับโมดูลอื่นในแร็ค\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eไฟ LED บายพาสแผงด้านหน้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสว่างขึ้นเมื่อช่องหรือหน้าจอถูกตั้งค่าเป็นโหมดบายพาส\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเทอร์มินัล I\/O ด้านหลัง\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eจุดต่อสายตรงสำหรับสายฟิลด์ RTD และเทอร์โมคัปเปิล\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอินเทอร์เฟซเอาต์พุตเครื่องบันทึก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการเชื่อมต่อแบบขนานที่ให้วงจรวินิจฉัย +4 ถึง +20 mA แยกอิสระ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการติดตั้งการ์ดหลัก:\u003c\/strong\u003e ติดตั้งโมดูลหน้าจอหลักในช่องว่างเต็มความสูงที่ว่างอยู่ใดก็ได้ทางด้านขวาของโมดูลอินเทอร์เฟซแร็ค\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eตำแหน่งโมดูล I\/O:\u003c\/strong\u003e ติดตั้งโมดูล I\/O อุปสรรคภายใน RTD\/TC ที่ไม่แยกตัวที่ตรงกันในช่องด้านหลังเต็มความสูงที่อยู่ตรงหลังหน้าจอหลักด้านหน้า\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการบรรเทาความตึงเครียดของสายเคเบิล:\u003c\/strong\u003e จัดเส้นนำเซ็นเซอร์ภายนอกแยกจากสายจ่ายไฟแรงดันสูงที่มีเสียงรบกวนเพื่อกำจัดการรบกวนทางไฟฟ้าข้ามวงจรที่ไม่แยกตัว\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตรวจสอบการกำหนดค่า:\u003c\/strong\u003e ก่อนการใช้งานโรงงาน ให้กำหนดเส้นโค้งเซ็นเซอร์ที่แม่นยำ (ค่าอัลฟา) และคุณสมบัติการปรับสเกลภายในยูทิลิตี้ซอฟต์แวร์ 3500 Configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการปฏิบัติตามและการรับรอง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eคำสั่ง EMC:\u003c\/strong\u003e 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eมาตรฐาน EMC:\u003c\/strong\u003e EN 61000-6-2 (ความต้านทานสำหรับสภาพแวดล้อมอุตสาหกรรม), EN 61000-6-4 (การปล่อยสัญญาณสำหรับสภาพแวดล้อมอุตสาหกรรม), EN 55011 Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eความปลอดภัยทางไฟฟ้า:\u003c\/strong\u003e 2014\/35\/EU Low Voltage Directive; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการอนุมัติพื้นที่อันตราย (พร้อมอุปสรรคภายใน):\u003c\/strong\u003e CSA\/NRTL\/C Class I, Division 2, Groups A, B, C และ D (พร้อมเอาต์พุต IS สำหรับ Division 1); Class I, Zone 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc หรือ AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (พร้อมอุปสรรคภายใน):\u003c\/strong\u003e Ex II 3(1) G; Ex nA nC ic [ia Ga] IIC T4 Gc หรือ Ex ec nC ic [ia Ga] IIC T4 Gc ที่ Ta = -20 องศาเซลเซียส ถึง +65 องศาเซลเซียส\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eความปลอดภัยเชิงฟังก์ชัน:\u003c\/strong\u003e ออกแบบให้เป็นไปตามข้อกำหนด SIL 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668299379051,"sku":"3500\/61-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-61-05-CN-cfhoqahh0w4_028b5b49-848f-4c41-80b1-1f94bb49297c.jpg?v=1765520500"},{"product_id":"bently-nevada-136188-01-3500-series-ethernet-rs232-modbus-i-o-module","title":"โมดูล I\/O Bently Nevada 136188-01 ซีรีส์ 3500 Ethernet\/RS232 Modbus","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการรวมเข้ากับสถาปัตยกรรมการตรวจสอบในอุตสาหกรรมอย่างไร้รอยต่อ \u003cstrong\u003e136188-01\u003c\/strong\u003e ทำหน้าที่เป็นแผงหลังอินเทอร์เฟซ I\/O สำหรับโมดูลเกตเวย์สื่อสาร Bently Nevada 3500\/92 โมดูล \u003cstrong\u003eEthernet\/RS232 Modbus I\/O\u003c\/strong\u003e ที่ทนทานนี้สร้างลิงก์การสื่อสารดิจิทัลที่ปลอดภัยและมีประสิทธิภาพระหว่างระบบป้องกันเครื่องจักร 3500 กับทรัพย์สินภายนอกโรงงาน เช่น ระบบควบคุมแบบกระจาย (DCS), ตัวควบคุมตรรกะโปรแกรมได้ (PLC) และแพลตฟอร์ม SCADA\u003c\/p\u003e\n\n\u003cp\u003eโดยการรวมความสามารถ Ethernet ความเร็วสูงและการเชื่อมต่อแบบอนุกรมรุ่นเก่า โมดูลนี้ช่วยให้การแปลและส่งข้อมูลเครื่องจักรทั้งแบบคงที่และแบบไดนามิก อินเทอร์เฟซนี้รับประกันว่าพารามิเตอร์วินิจฉัยแบบเรียลไทม์และสถานะสัญญาณเตือนจะพร้อมใช้งานทั่วเครือข่ายโรงงานโดยไม่กระทบต่อความสามารถด้านความปลอดภัยหลักและการปิดเครื่องของแร็คป้องกัน\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eสถาปัตยกรรมอินเทอร์เฟซคู่ที่มีพอร์ต RJ45 Ethernet และพอร์ตอนุกรม RS232 แยกเฉพาะ\u003c\/li\u003e\n  \u003cli\u003eการเชื่อมต่อแผงหลังโดยตรงออกแบบเฉพาะสำหรับระบบแร็ค Bently Nevada 3500\u003c\/li\u003e\n  \u003cli\u003eรองรับการกำหนดค่าการสื่อสารพร้อมกันเพื่อเพิ่มประสิทธิภาพการรวมระบบ\u003c\/li\u003e\n  \u003cli\u003eโครงสร้างที่ทนทานสำหรับความน่าเชื่อถือสูงในสภาพแวดล้อมอุตสาหกรรมที่รุนแรง\u003c\/li\u003e\n  \u003cli\u003eรองรับโปรโตคอลข้อมูล Modbus TCP\/IP ความเร็วสูงและ Modbus RTU มาตรฐาน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eสถานีผลิตไฟฟ้าที่ตรวจสอบระบบกังหันไอน้ำและกังหันแก๊ส\u003c\/li\u003e\n  \u003cli\u003eการสกัดและกลั่นน้ำมันและก๊าซ\u003c\/li\u003e\n  \u003cli\u003eโรงงานแปรรูปปิโตรเคมี\u003c\/li\u003e\n  \u003cli\u003eการควบคุมเครื่องจักรหมุนในอุตสาหกรรมหนัก\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e136188-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eระบบป้องกันเครื่องจักร 3500 ซีรีส์\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eโมดูล Ethernet \/ RS232 Modbus I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eโมดูลเกตเวย์ที่เข้ากันได้\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/92 Communication Gateway\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eพอร์ตอินเทอร์เฟซ Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x RJ45 (รองรับ 10Base-T\/100Base-TX)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eพอร์ตอินเทอร์เฟซอนุกรม\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1x RS232 การเชื่อมต่อ DB9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eโปรโตคอลที่รองรับ\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModbus TCP, Modbus RTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเทศที่ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eน้ำหนักจัดส่ง\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 กก.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eประเภทพอร์ต\u003c\/th\u003e\n      \u003cth\u003eมาตรฐานตัวเชื่อมต่อ\u003c\/th\u003e\n      \u003cth\u003eฟังก์ชันโปรโตคอลหลัก\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eพอร์ต Ethernet\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eการสื่อสาร Modbus TCP Client\/Server ผ่าน LAN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eพอร์ตอนุกรม\u003c\/td\u003e\n      \u003ctd\u003eRS232 (DB9)\u003c\/td\u003e\n      \u003ctd\u003eการกำหนดค่าและวินิจฉัย Modbus RTU แบบจุดต่อจุด\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eการติดตั้งทางกายภาพและการต่อสายดินอย่างถูกต้องเป็นสิ่งสำคัญเพื่อป้องกันการเสียหายของข้อมูลหรืออุปกรณ์ ปฏิบัติตามขั้นตอนวิศวกรรมดังนี้:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eการจัดตำแหน่งช่องเสียบ:\u003c\/strong\u003e ติดตั้งโมดูล I\/O 136188-01 ในช่องเสียบด้านหลังของแร็ค 3500 โดยตรงด้านหลังโมดูลเกตเวย์สื่อสารหลัก 3500\/92\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eลำดับการจ่ายไฟ:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าแหล่งจ่ายไฟของแร็คปิดอยู่หรือปฏิบัติตามขั้นตอนการสลับร้อนอย่างเคร่งครัดในระหว่างการใส่โมดูลเพื่อปกป้องวงจรทรานซิฟเวอร์บัสจากแรงดันไฟกระชากชั่วคราว\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eการป้องกันและสายเคเบิล:\u003c\/strong\u003e ใช้สายอีเธอร์เน็ตอุตสาหกรรมที่มีการป้องกันคุณภาพสูงระดับ Category 5e หรือดีกว่า สำหรับการเชื่อมต่ออนุกรม RS232 ให้ใช้สายที่มีการป้องกันความจุต่ำและจำกัดความยาวสายไม่เกิน 15 เมตรตามมาตรฐาน\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eการต่อสายดิน:\u003c\/strong\u003e ตรวจสอบให้แน่ใจว่าตัวเครื่อง 3500 ต่อสายดินอย่างถูกต้องกับระบบสายดินที่มีความต้านทานต่ำเพื่อป้องกันสัญญาณรบกวนแม่เหล็กไฟฟ้า (EMI)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301443435,"sku":"136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/136188-01-oreoavsu1xk_66140140-1c4d-4f47-96f7-c88c3a57c080.jpg?v=1765520550"},{"product_id":"bently-nevada-163179-02-3500-60-temperature-monitor-i-o-module","title":"Bently Nevada 163179-02 3500\/60 Temperature Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding highly reliable thermal sensor integration within industrial machinery protection systems, the \u003cstrong\u003eBently Nevada 163179-02\u003c\/strong\u003e serves as the dedicated RTD\/TC Non-Isolated I\/O Module with Internal Terminations. Engineered specifically for use with the 3500\/60 and 3500\/61 Temperature Monitor series, this hardware interface accepts inputs from both Resistive Temperature Detectors (RTD) and Thermocouples (TC). Its internal termination design eliminates the need for external terminal blocks, simplifying control cabinet layouts and reducing field wiring complexity. Each module connects directly to the backplane of the 3500 rack, transmitting digitized temperature data to the main monitor module for real-time safety trips and machinery diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Sensor Connection:\u003c\/strong\u003e Supports dual-element RTDs and various thermocouple calibrations without external signal conditioning.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Terminations:\u003c\/strong\u003e Integrated terminal strips located directly on the card ease point-to-point field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Isolated Architecture:\u003c\/strong\u003e Cost-efficient, space-saving design optimized for installations sharing a common instrumentation ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Hot-Swapping:\u003c\/strong\u003e Minimizes system downtime by allowing rear module replacement while keeping adjacent modules online.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Protection Integration:\u003c\/strong\u003e Communicates seamlessly with the 3500 backplane to trigger automatic emergency trip limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eRadial and thrust bearing temperature monitoring in heavy steam or gas turbines.\u003c\/li\u003e\n  \u003cli\u003eThermal monitoring of generator stator windings and rotor bearing housings.\u003c\/li\u003e\n  \u003cli\u003eContinuous casing and process gas temperature diagnostics in centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eHigh-capacity electric motor protection in critical petrochemical and mining facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSpecification Values\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e163179-02 (Component of 3500\/60)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTermination Style\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInternal Terminations (Screw clamp terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCompatible Monitors\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/60 and 3500\/61 Temperature Monitors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eThermocouple Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eType J, K, T, E (with cold-junction compensation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRTD Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 ohm Platinum (3-wire and 4-wire configurations)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-30 degC to +65 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe rear terminal strip provides hardwired connections for up to six separate temperature channels. Use shielded twisted-pair cabling for all RTD and TC inputs to maintain noise immunity.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eRTD Mode Connection\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eThermocouple Mode Connection\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eA\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSource \/ Lead Compensation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNo Connection (Open)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eB\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSignal (+) Return\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePositive (+) Leg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCommon (-) Return\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNegative (-) Leg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSHIELD\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInstrument Ground Shield\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInstrument Ground Shield\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 163179-02 non-isolated module features integrated internal termination blocks. If replacing older external termination setups (such as the 133900-01 board), you must convert your wiring topology to land directly on this rear module. Ensure that the main front-facing 3500\/60 or 3500\/61 processor card runs compatible firmware to correctly recognize the non-isolated parameter set.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this module is non-isolated, all input grounds share a common reference potential inside the 3500 rack. Avoid using non-isolated sensors in electrically noisy settings or in plants experiencing ground grid variance, as this can lead to phantom temperature spikes, high-level noise on signal loops, or false alarm triggers. If sensors are ungrounded at the field junction, always tie the cable shields directly to the chassis ground terminal of this I\/O module.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations utilizing thermocouples, allow the internal cold junction compensation (CJC) circuit to thermally stabilize for 15 to 20 minutes after cabinet power-up before taking baseline commissioning readings. Always route instrument-level RTD\/TC wiring through isolated cable trays away from high-voltage motor feeds to mitigate electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDe-energize the entire 3500 chassis and isolate all auxiliary trip loops before extracting or installing rear I\/O cards. Failure to bypass active protection outputs could result in an accidental plant shut down or equipment trip.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003ePower down the rack or switch the front-panel keyswitch to \"Program Mode\" to inhibit auto-trips.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eAlign the 163179-02 card with the designated guide rails on the rear chassis slot corresponding to the monitor module.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eSlide the module firmly forward into the backplane connectors until the mounting screws line up with the rack frame.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eTighten the retaining screws to ground the module housing properly. Secure all sensor channels onto the internal screw terminals.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668304097643,"sku":"3500\/60 163179-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/163179-02_-jj4mrhjwcqo_a907a3e8-2b77-42d7-bb7c-27ec4ba8d612.jpg?v=1765521155"},{"product_id":"bently-nevada-3500-61-01-cn-temperature-module-with-recorder-outputs","title":"โมดูลอุณหภูมิ Bently Nevada 3500\/61-01-CN พร้อมเอาต์พุตเครื่องบันทึก","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eการ์ดตรวจสอบที่ประมวลผล \u003cstrong\u003e3500\/61-01-CN\u003c\/strong\u003e ให้ช่องสัญญาณอุณหภูมิอิสระหกช่องสำหรับการตรวจสอบอุณหภูมิอย่างต่อเนื่องและประมวลผลข้อมูลจากเซ็นเซอร์ตรวจจับอุณหภูมิแบบต้านทาน (RTD) และเทอร์โมคัปเปิล (TC) ภายในระบบป้องกันเครื่องจักร Bently Nevada 3500 Series แร็คโมดูลนี้จะสุ่มตัวอย่างสัญญาณแอนะล็อกทางกายภาพ ปรับสัญญาณดิบที่เข้ามา และดำเนินการเปรียบเทียบกับค่าขีดจำกัดการแจ้งเตือนที่ผู้ใช้ตั้งโปรแกรมไว้ การออกแบบ \u003cstrong\u003e3500\/61\u003c\/strong\u003e มีเอาต์พุตกระแสเครื่องบันทึกแอนะล็อกเฉพาะสำหรับแต่ละช่องสัญญาณภายในหกช่อง ทำให้สามารถเชื่อมต่อเทเลเมทรีแบบเรียลไทม์กับวงจรเครื่องมือคู่ขนานได้\u003c\/p\u003e\n\u003cp\u003eทำงานภายในเครือข่ายเครื่องจักรที่ซับซ้อนแบบกระจาย โมดูลประเภท \u003cstrong\u003e3500\/61-01-CN\u003c\/strong\u003e ทำงานร่วมกับซอฟต์แวร์กำหนดค่าแร็ค 3500 อย่างเป็นธรรมชาติเพื่อกำหนดคำนิยามเซ็นเซอร์ที่ปรับแต่งได้หรือโปรไฟล์ผสมทรานสดิวเซอร์ที่หลากหลาย เมื่อใช้งานในบล็อกความปลอดภัย Triple Modular Redundant (TMR) โมดูลอุณหภูมิเหล่านี้จะถูกจัดวางติดกันเป็นกลุ่มสามตัว ใช้ตรรกะการโหวตสองชั้นเพื่อลดความเสี่ยงจากความล้มเหลวจุดเดียวในเครือข่ายเครื่องจักร การกำหนดค่านี้ใช้ส่วนประกอบ I\/O RTD\/TC ที่ไม่แยกวงจร มีการต่อสายอัดภายในและมีตัวเลือกการอนุมัติหน่วยงานท้องถิ่น CN เฉพาะ เพื่อรับประกันการเชื่อมต่อภาคสนามในตลับลูกปืนเครื่องจักรหมุนอุตสาหกรรม\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eช่องสัญญาณที่ปรับแต่งได้เต็มรูปแบบหกช่องรองรับการประมวลผลผสมของเซ็นเซอร์วัดอุณหภูมิแบบเทอร์โมคัปเปิลและ RTD\u003c\/li\u003e\n\u003cli\u003eเอาต์พุตเครื่องบันทึกแอนะล็อกสัดส่วน +4 ถึง +20 mA หกช่องที่ทุ่มเทให้เพื่อการติดตามเทเลเมทรีที่สะอาดไปยังโหนดภายนอก\u003c\/li\u003e\n\u003cli\u003eการตั้งค่าการหน่วงเวลาการแจ้งเตือนและพารามิเตอร์การแจ้งเตือนจุดตั้งค่าที่ปรับแต่งได้ผ่านซอฟต์แวร์อินเทอร์เฟซแร็คในตัว\u003c\/li\u003e\n\u003cli\u003eการสนับสนุนฮาร์ดแวร์สำหรับการกำหนดค่าการโหวตแบบหลายการ์ด Triple Modular Redundant (TMR) เพื่อเพิ่มความสมบูรณ์ของวงจรโรงงาน\u003c\/li\u003e\n\u003cli\u003eการออกแบบการต่อสายภายในด้วยบล็อกเทอร์มินัลสกรูอัดที่ทนทานเพื่อให้การเชื่อมต่อสายไฟภาคสนามโดยตรงเป็นไปอย่างราบรื่น\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eการติดตามอุณหภูมิรัศมีของตลับลูกปืนและความร้อนของขดลวดสเตเตอร์อย่างต่อเนื่องในกังหันไอน้ำและกังหันแก๊สสำหรับการขับเคลื่อนสาธารณูปโภค\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบอุณหภูมิแก๊สไอเสียหลายช่องสัญญาณและการป้องกันความร้อนของตัวเรือนแรงดันสูงในเครื่องอัดแรงเหวี่ยงสำหรับกระบวนการ\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบความปลอดภัยของระบบล็อกอินเตอร์ล็อกที่สำคัญสำหรับมอเตอร์และตลับลูกปืนปั๊มอุตสาหกรรมความจุสูง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลการสั่งซื้อ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eหมายเลขชิ้นส่วน \/ รหัสตัวเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eคำอธิบายการเลือก\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/61-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลอุณหภูมิ 3500\/61 พร้อมเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจรพร้อมการสิ้นสุดภายใน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eตัวเลือกการอนุมัติ: การกำหนดค่าการปฏิบัติตามหน่วยงานท้องถิ่นเฉพาะ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eการจำแนกพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eค่าทางวิศวกรรมที่แม่นยำ\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eหมายเลขชิ้นส่วนหลัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/61-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eโมดูลอุณหภูมิกับเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eจำนวนช่องทั้งหมด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 ช่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอินพุตที่รองรับ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD (แพลตตินัม 100 โอห์ม, นิกเกิล 120 โอห์ม, ทองแดง 10 โอห์ม) และเทอร์โมคัปเปิล (ชนิด E, J, K, T, R, S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความต้านทานอินพุต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eมากกว่า 221 กิโลโอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eการใช้พลังงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eการใช้พลังงานสูงสุดโดยทั่วไป 7.0 วัตต์\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเอาต์พุตกระแสเครื่องบันทึก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eช่วงเอาต์พุตสัดส่วน +4 ถึง +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eโหลดเครื่องบันทึกสูงสุด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 โอห์ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความละเอียด\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3125 ไมโครแอมแปร์ต่อบิต\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเวลาการอัปเดต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสูงสุด 1 วินาทีต่อช่อง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eช่วงอุณหภูมิการทำงาน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส (-22 เซลเซียส ถึง +150 เซลเซียส)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขีดจำกัดอุณหภูมิการเก็บรักษา\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 องศาเซลเซียส ถึง +85 องศาเซลเซียส (-40 เซลเซียส ถึง +185 เซลเซียส)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขอบเขตความชื้นสัมพัทธ์\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eความชื้นสัมพัทธ์สูงสุดไม่ควบแน่น 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักการ์ดมอนิเตอร์หลัก\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.73 กก. (1.6 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักโมดูล I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 กก. (0.69 ปอนด์)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดโมดูลหลัก (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 241.8 มม. (9.50 นิ้ว x 0.96 นิ้ว x 9.52 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาดโมดูล I\/O (สูง x กว้าง x ลึก)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 มม. x 24.4 มม. x 99.1 มม. (9.50 นิ้ว x 0.96 นิ้ว x 3.90 นิ้ว)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eการเชื่อมต่อ\/อินเทอร์เฟซ\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eการเชื่อมต่อบล็อกเทอร์มินัล\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eการกำหนดฟังก์ชันและการวางสาย\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eอินพุตช่อง 1 ถึง 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วสกรูอินพุตสำหรับ RTD แบบ 3 สาย\/4 สาย หรือคู่สายเทอร์โมคัปเปิลเฉพาะ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eเอาต์พุตเครื่องบันทึก 1 ถึง 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eขั้วต่อเอาต์พุตวงจรกระแสเฉพาะ (+4 ถึง +20 mA) สำหรับการเชื่อมต่อการตรวจสอบภายนอกที่ตรงกัน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eลำดับช่องแร็ค:\u003c\/strong\u003e ติดตั้งบอร์ดโปรเซสเซอร์ตรวจสอบด้านหน้าในช่องความสูงเต็มที่ใดก็ได้ของโครง 3500 และยึดโมดูล I\/O ด้านหลังที่มีการสิ้นสุดภายในให้ตรงกับด้านหลังของแผงหลัง\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eขั้นตอนการกราวด์ชิลด์:\u003c\/strong\u003e ต่อสายชิลด์ถักโลหะภายนอกของสายเซ็นเซอร์ภาคสนามทั้งหมดอย่างเรียบร้อยกับบัสบาร์กราวด์ของโครงเครื่องที่ใกล้ที่สุดบนแร็คเพื่อป้องกันสัญญาณรบกวนไฟฟ้าภายนอก\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการปรับสมดุลสายไฟ:\u003c\/strong\u003e เมื่อใช้สายต่อ RTD ระยะไกล ต้องแน่ใจว่าใช้ขนาดสายและความยาวสายที่ตรงกันในรูปแบบสาย 3 เส้นเพื่อรักษาความแม่นยำของการติดตามความต้านทานภายในวงจร\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการป้องกันไฟฟ้าสถิต:\u003c\/strong\u003e เจ้าหน้าที่บำรุงรักษาต้องเชื่อมต่อกับสายกราวด์ของอุปกรณ์โดยใช้สายรัดข้อมือกราวด์ที่ได้รับอนุมัติก่อนดึง ตรวจสอบ หรือใส่โครงสร้างการ์ดโปรเซสเซอร์ใดๆ\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307603819,"sku":"3500\/61-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-01-CN-ls515xj2f5y_45df22ef-c683-4cf7-8b6e-c6a415a22590.jpg?v=1765520724"},{"product_id":"bently-nevada-133300-01-3500-series-low-voltage-dc-power-input-module","title":"โมดูลอินพุตพลังงาน DC แรงดันต่ำ Bently Nevada 133300-01 ซีรีส์ 3500","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eออกแบบมาเพื่อต่อเชื่อมโดยตรงกับระบบแหล่งจ่ายไฟ 3500\/15, \u003cstrong\u003eBently Nevada 133300-01\u003c\/strong\u003e ให้ความสามารถในการรับไฟฟ้ากระแสตรงแรงดันต่ำที่ควบคุมได้สำหรับชั้นวางระบบป้องกันเครื่องจักร 3500 โมดูลติดตั้งด้านหลังนี้รับแรงดันไฟฟ้า \u003cstrong\u003e20 ถึง 30 VDC\u003c\/strong\u003e และปรับสภาพพลังงานหลักที่เข้ามาก่อนส่งต่อไปยังแผงวงจรภายใน ออกแบบสำหรับสภาพแวดล้อมที่ต้องการความน่าเชื่อถือสูง มีความสำคัญต่อการรักษาการตรวจสอบเครื่องจักรอย่างต่อเนื่องและปกป้องทรัพย์สินหมุนที่สำคัญจากการหยุดชะงักของพลังงานโดยไม่คาดคิด\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eการรวมระบบอย่างราบรื่นกับแหล่งจ่ายไฟ DC แรงดันต่ำ 3500\/15\u003c\/li\u003e\n  \u003cli\u003eรองรับการกำหนดค่าพลังงานสำรองเต็มรูปแบบเมื่อใช้ร่วมกับโมดูลด้านหลังตัวที่สอง\u003c\/li\u003e\n  \u003cli\u003eขั้วต่อบล็อกเทอร์มินัลที่ทนทานต่อการสั่นสะเทือนในอุตสาหกรรมหนัก\u003c\/li\u003e\n  \u003cli\u003eมีระบบป้องกันกระแสเกินและกรองสัญญาณรบกวนแม่เหล็กไฟฟ้า (EMI) ในตัว\u003c\/li\u003e\n  \u003cli\u003eออกแบบระบายความร้อนแบบพาสซีฟ เหมาะสำหรับการใช้งานชั้นวางอย่างต่อเนื่อง\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eระบบตรวจจับการสั่นสะเทือนของกังหันไอน้ำและกังหันแก๊ส\u003c\/li\u003e\n  \u003cli\u003eการตั้งค่าการป้องกันเครื่องกำเนิดไฟฟ้าพลังน้ำ\u003c\/li\u003e\n  \u003cli\u003eชั้นวางความปลอดภัยคอมเพรสเซอร์และปั๊มในโรงงานปิโตรเคมี\u003c\/li\u003e\n  \u003cli\u003eสถานีผลิตและจ่ายไฟฟ้าอุตสาหกรรมหนัก\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eผู้ผลิต\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e133300-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eซีรีส์\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eระบบป้องกันเครื่องจักร 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eประเภทโมดูล\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eโมดูลจ่ายไฟ DC แรงดันต่ำ (LVDCI)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eช่วงแรงดันไฟฟ้าขาเข้า\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eช่วงแรงดันไฟฟ้าขาเข้า 20 ถึง 30 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eแหล่งจ่ายด้านหน้าที่เข้ากันได้\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eโมดูลจ่ายไฟ DC แรงดันต่ำ 3500\/15\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eตำแหน่งติดตั้ง\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eช่องตัวถังด้านหลัง (ครึ่งความสูง)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: -0.75rem;\"\u003e-30 ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.50 กก. (3.30 ปอนด์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24.1 ซม. x 11.2 ซม. x 5.1 ซม.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; width: 40%;\"\u003eขั้วต่อบล็อกเทอร์มินัล\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eฟังก์ชัน \/ การกำหนดวงจร\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eบวก (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eไฟฟ้ากระแสตรง 24 โวลต์หลัก\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eลบ (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eการส่งกลับ DC \/ ร่วมกัน\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eกราวด์ตัวถัง (GND)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eการเชื่อมต่อระบบ \/ กราวด์โลกสำหรับความต่อเนื่องของโล่\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eข้อมูลเชิงประจักษ์ทางวิศวกรรม\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eรุ่นทางเลือกและความเข้ากันได้\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eโมดูล 133300-01 ถูกจับคู่เฉพาะกับรุ่นแรงดันต่ำของแหล่งจ่ายไฟ 3500\/15 เท่านั้น ซึ่งไม่เข้ากันทางกายภาพและไฟฟ้ากับโมดูล AC\/DC แรงดันสูง (เช่น 129767-01 หรือ 120739-01) ตรวจสอบแรงดันไฟฟ้าของโมดูล 3500\/15 ด้านหน้าเสมอก่อนสลับร้อนหรือเปลี่ยนชิ้นส่วนอินพุตด้านหลัง\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eข้อควรระวังในการใช้งานและบันทึกทางวิศวกรรม\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eในระบบสำรองคู่ ให้แน่ใจว่าแหล่งจ่ายไฟ DC แรงดันต่ำทั้งสองมาจากเบรกเกอร์หรือแหล่งจ่ายไฟที่แยกจากกัน หากอินพุตทั้งสองเชื่อมต่อกับวงจรฟีดเดอร์เดียวกัน ระบบสำรองจะถูกข้ามไปโดยปริยาย หลีกเลี่ยงการเดินสาย DC ภาคสนามดิบที่ไม่ได้กรองตรงไปยังเทอร์มินัลเหล่านี้ ใช้การปรับสภาพสายไฟภายนอกหากสายเคเบิลยาวและมีเสียงรบกวนจากการสวิตช์เหนี่ยวนำ\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eเคล็ดลับการเริ่มใช้งานและการเดินสาย\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eใช้สายไฟขนาดอย่างน้อย 14 AWG (2.1 มม.²) เพื่อป้องกันแรงดันตกมากเกินไปเมื่อเดินสายเกิน 10 เมตร ตรวจสอบให้แน่ใจว่าสกรูบล็อกเทอร์มินัลถูกขันด้วยแรงบิดที่ 0.56 นิวตันเมตร (5 นิ้ว-ปอนด์) อย่างแม่นยำเพื่อรักษาการเชื่อมต่อที่มั่นคงภายใต้การสั่นสะเทือนของเครื่องจักรความถี่สูงอย่างต่อเนื่อง\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eคำเตือนสำคัญ\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eตัดไฟฟ้ากระแสตรงหลักทั้งหมดก่อนติดตั้ง ถอด หรือเดินสายโมดูลอินพุตด้านหลัง การให้บริการขณะมีไฟฟ้าสามารถทำให้เกิดประกายไฟฟ้าอันตราย ความเสียหายต่อจุดสัมผัสเฉพาะที่ หรือการเสื่อมสภาพของส่วนประกอบแผงหลังที่สำคัญ\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eตรวจสอบให้แน่ใจว่าสวิตช์ไฟหลักของแร็ค 3500 อยู่ในตำแหน่งปิด และเบรกเกอร์ DC แหล่งจ่ายไฟถูกล็อกไว้\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eจัดแนวขอบการ์ดโมดูล 133300-01 กับรางการ์ดในช่องครึ่งความสูงด้านหลังที่กำหนดไว้\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eเลื่อนโมดูลไปข้างหน้าอย่างแน่นหนาจนตัวเชื่อมต่อของมันเชื่อมต่อกับตัวเชื่อมต่อของแผงหลังอย่างสมบูรณ์\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eยึดสกรูยึดแผ่นหน้าปิดที่ถูกล็อกและติดตั้งฝาครอบเทอร์มินัลหลังจากเสร็จสิ้นการเดินสายไฟภาคสนาม\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308128107,"sku":"133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/133300-01-ry5osi23wfo_6abd5e5b-a071-487b-b77b-e56c673e66b4.jpg?v=1765520743"},{"product_id":"bently-nevada-176449-08-3500-series-rod-position-monitor-i-o-module","title":"Bently Nevada 176449-08 3500 Series Rod Position Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo track the exact dynamic displacement of piston rods in reciprocating compressors, the \u003cstrong\u003eBently Nevada 176449-08\u003c\/strong\u003e functions as a highly specialized I\/O module within the 3500 Machinery Protection System. This module interfaces directly with the 3500\/72M Reciprocating Compressor Rod Position Monitor, processing signal inputs from proximity probes and seismic transducers to ensure precise tracking of rod runout and position. By offering \u003cstrong\u003einternal termination\u003c\/strong\u003e capabilities, this unit simplifies cabinet wiring and eliminates the need for external termination blocks, directly improving signal integrity and reducing installation footprints in critical petrochemical and gas processing plants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eFour-channel input capability supporting both Proximitor and seismic transducers.\u003c\/li\u003e\n  \u003cli\u003eInternal termination architecture to streamline cabinet design and lower point-to-point wiring risks.\u003c\/li\u003e\n  \u003cli\u003eDirect backplane communication for high-speed data transmission to the main 3500 system rack.\u003c\/li\u003e\n  \u003cli\u003eDesigned for harsh industrial environments, ensuring continuous monitoring of critical reciprocating machinery.\u003c\/li\u003e\n  \u003cli\u003eHot-swappable design allows replacement of the physical I\/O card without shutting down the entire protection rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eReciprocating compressor rod runout and mean position tracking.\u003c\/li\u003e\n  \u003cli\u003eCrosshead vibration measurement in high-pressure process gas systems.\u003c\/li\u003e\n  \u003cli\u003eContinuous industrial machinery health monitoring and protective tripping loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e176449-08\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eCompatible Monitor Module\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e3500\/72M Reciprocating Compressor Monitor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eTermination Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eInternal Termination\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eInput Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e4 Channels (Proximitor \/ Seismic)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eHost rack powered (nominal backplane draw)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-30 to +65 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-40 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eHumidity Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e95% non-condensing relative humidity\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e28.5 x 19.0 x 6.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe internal termination card provides a series of dedicated terminal blocks designed for secure field-wire attachment. Below is the typical pinout configuration layout for the input channels:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eTerminal Terminal Group\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eLabel Name\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 8px; font-weight: bold;\"\u003eSignal Assignment \/ Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 1 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 2 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 3 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\" rowspan=\"3\"\u003e\u003cstrong\u003eChannel 4 Block\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e-24V\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eTransducer Power Output (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Input (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eCOM\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSignal Common (Channel 4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003e\u003cstrong\u003eChassis Ground\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eSHLD\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 8px;\"\u003eShield Terminal (Internal Ring Connection to Rack Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 176449-08 is designed specifically for standard internal termination setups. It is not directly interchangeable with external termination (ET) versions (such as the 176449-01 through 176449-07 variations) unless you also replace the external terminal block and connection cables. Always verify the module suffix matched on the existing chassis slot card before installation to avoid channel mismatched configuration faults in the 3500\/72M monitor.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing this module for reciprocating rod runout measurements, ensure that the proximity probe target areas on the piston rods are completely free of surface scratches, mechanical runout, and electrical runout. Ground loops are a common source of signal distortion; transducer shields must be grounded only at the 3500 rack ground terminals on the 176449-08 I\/O card and cut back and isolated at the machine junction box.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUse 3-wire shielded, twisted-pair cable for all transducer runs back to the I\/O module. After installation, verify the DC gap voltage utilizing the 3500 Rack Configuration Software before commissioning. An incorrect transducer setting or a misaligned physical sensor gap will trigger a \"NOT OK\" channel status light on the front panel of the corresponding 3500\/72M monitor card.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eAlways verify that the 3500 monitor rack is fully de-energized or the specific monitor channel has been bypassed and bypassed outputs are locked out before inserting or removing the I\/O module. Direct hot-swapping under active process trip loops can cause catastrophic machinery shutdown signals to the Distributed Control System (DCS) or Safety Instrumented System (SIS).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePower down the immediate slot or verify that the 3500\/72M monitor associated with the slot is in \"Bypass\" status.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWear a grounded ESD wrist strap before handling the sensitive internal circuit board of the 176449-08 module.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the I\/O module into the rear slots of the 3500 chassis until the connector seating pins are securely in position.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecure the integrated thumbscrews tightly to ensure continuous chassis grounding and physical retention.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309537131,"sku":"176449-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/176449-08-oiaw2ohsfqx_97a0c840-86fb-4948-86e9-0af87bc1f285.jpg?v=1765520799"},{"product_id":"bently-nevada-3500-61-01-00-3500-series-temperature-monitor-with-recorder-outputs","title":"Bently Nevada 3500\/61-01-00 ชุดตรวจวัดอุณหภูมิรุ่น 3500 พร้อมเอาต์พุตเครื่องบันทึกข้อมูล","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการปกป้องเครื่องจักรอย่างต่อเนื่อง \u003cstrong\u003eBently Nevada 3500\/61-01-00\u003c\/strong\u003e ประมวลผลสัญญาณอุณหภูมิจากตัวตรวจจับอุณหภูมิแบบความต้านทาน (RTDs) และเทอร์โมคัปเปิล (TCs) โมดูลหกช่องนี้เปรียบเทียบสัญญาณอุณหภูมิอย่างต่อเนื่องกับจุดตั้งค่าการแจ้งเตือนที่ผู้ใช้กำหนดไว้ เพื่อปกป้องเครื่องจักรอุตสาหกรรมที่สำคัญจากความเสียหายทางความร้อน รุ่น \u003cstrong\u003e3500\/61-01-00\u003c\/strong\u003e ถูกกำหนดค่าด้วยโมดูล I\/O RTD\/TC แบบไม่แยกวงจรที่ใช้การต่อสายภายใน ทำให้สามารถเชื่อมต่อสายไฟได้โดยตรงและสะอาดภายในตู้แร็ค\u003c\/p\u003e\n\n\u003cp\u003eนอกจากการตรวจสอบการแจ้งเตือนแบบแอคทีฟแล้ว โมดูลนี้ยังมีเอาต์พุตสำหรับเครื่องบันทึกแบบแอนะล็อกเฉพาะสำหรับแต่ละช่องทั้งหก ช่องสัญญาณบันทึกเหล่านี้ให้สัญญาณต่อเนื่องที่สัดส่วนกับอุณหภูมิไปยังระบบควบคุมภายนอก เช่น ระบบควบคุมแบบกระจาย (DCS), ตัวควบคุมตรรกะโปรแกรมได้ (PLC) หรือเครื่องบันทึกแถบกราฟ เพื่อให้มั่นใจในการบันทึกข้อมูลประวัติและการแสดงผลกระบวนการอย่างราบรื่น\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eตรวจสอบอุณหภูมิได้ต่อเนื่องสูงสุดถึงหกช่องสัญญาณอิสระ\u003c\/li\u003e\n  \u003cli\u003eรองรับเซ็นเซอร์อุณหภูมิทั้งเทอร์โมคัปเปิลและ RTD\u003c\/li\u003e\n  \u003cli\u003eมีเอาต์พุตเครื่องบันทึกแอนะล็อกอิสระสำหรับแต่ละช่องเพื่อเชื่อมต่อกับระบบภายนอก\u003c\/li\u003e\n  \u003cli\u003eใช้การกำหนดค่าโมดูล I\/O แบบต่อสายภายในสำหรับการเดินสายตรงไปยังบอร์ด\u003c\/li\u003e\n  \u003cli\u003eรองรับการตั้งค่าการแจ้งเตือนที่ปรับแต่งได้ รวมถึงจุดตั้งค่า Alert และ Danger พร้อมการหน่วงเวลาที่ตั้งโปรแกรมได้\u003c\/li\u003e\n  \u003cli\u003eผสานรวมอย่างสมบูรณ์กับระบบป้องกันเครื่องจักร Bently Nevada 3500 แร็ค, แบ็คเพลน และซอฟต์แวร์\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eติดตามอุณหภูมิแบริ่งของกังหันไอน้ำ, กังหันแก๊ส และกังหันน้ำ\u003c\/li\u003e\n  \u003cli\u003eปกป้องขดลวดและสเตเตอร์ของมอเตอร์ไฟฟ้าและเครื่องกำเนิดไฟฟ้าขนาดใหญ่\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบอุณหภูมิของตัวเครื่องปั๊มและคอมเพรสเซอร์ในอุตสาหกรรม\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบเกียร์บ็อกซ์อุตสาหกรรม, ตู้เครื่องจักร และถังน้ำมันหล่อลื่น\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eพารามิเตอร์\u003c\/th\u003e\n      \u003cth\u003eรายละเอียด\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eหมายเลขรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500\/61-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eซีรีส์\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3500 Series Machinery Protection System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eเครื่องตรวจสอบอุณหภูมิมีเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eตัวเลือกโมดูล I\/O (-01)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจรพร้อมการต่อสายภายใน\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eตัวเลือกการอนุมัติจากหน่วยงาน (-00)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eไม่มี\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eจำนวนช่องสัญญาณ\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 ช่องต่อโมดูล\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเภทสัญญาณขาเข้า\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eเทอร์โมคัปเปิล (TC) และตัวตรวจจับอุณหภูมิแบบความต้านทาน (RTD)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eเอาต์พุต\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eเอาต์พุตเครื่องบันทึกแอนะล็อก 6 ช่อง (สัดส่วนกับอุณหภูมิของช่อง)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eประเทศที่ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eน้ำหนักจัดส่ง\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 กก.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eการเชื่อมต่อเทอร์มินัล\u003c\/th\u003e\n      \u003cth\u003eคำอธิบายขาเชื่อมต่อ\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eเทอร์มินัล Ch 1 - Ch 6\u003c\/td\u003e\n      \u003ctd\u003eการต่อสาย RTD หรือเทอร์โมคัปเปิลโดยตรง (ไม่แยกวงจร)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eเอาต์พุตเครื่องบันทึก\u003c\/td\u003e\n      \u003ctd\u003eวงจรสัญญาณกระแสหรือแรงดันแอนะล็อกเฉพาะสำหรับแต่ละช่อง\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eอินเทอร์เฟซแบ็คเพลน\u003c\/td\u003e\n      \u003ctd\u003eตัวเชื่อมต่อแบ็คเพลนระบบ 3500 แบบเฉพาะสำหรับจ่ายไฟและสื่อสารข้อมูล\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าระบบแร็ค 3500 ปิดไฟอย่างสมบูรณ์ก่อนใส่หรือถอดโมดูล I\/O หรือแผงวงจรหลักของมอนิเตอร์\u003c\/li\u003e\n  \u003cli\u003eยึดบล็อกการต่อสายภายในอย่างแน่นหนาด้วยสกรูยึดของโมดูลเพื่อรับประกันการสัมผัสทางกายภาพและไฟฟ้ากับแบ็คเพลนอย่างเชื่อถือได้\u003c\/li\u003e\n  \u003cli\u003eใช้สายเคเบิลบิดเกลียวมีชีลด์สำหรับการเดินสายเซ็นเซอร์ทั้งหมดเพื่อลดสัญญาณรบกวนแม่เหล็กไฟฟ้า (EMI) และสัญญาณรบกวนความถี่วิทยุ (RFI)\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าชีลด์สายดินตามมาตรฐานแผนผังโรงงานและระบบ โดยปกติจะต่อสายดินที่จุดกราวด์ร่วมของแร็คมอนิเตอร์เท่านั้น\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309963115,"sku":"3500\/61-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-01-00-xtkhixjynrt_181d4277-04bd-40cd-91af-57268dbb9a16.jpg?v=1765520814"},{"product_id":"bently-nevada-147663-01-3500-series-vga-display-i-o-module","title":"โมดูลแสดงผล VGA I\/O รุ่น 3500 Bently Nevada 147663-01","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการผสานรวมอย่างราบรื่นกับระบบป้องกันเครื่องจักร, \u003cstrong\u003e147663-01\u003c\/strong\u003e ทำหน้าที่เป็นอินเทอร์เฟซแสดงผล VGA แบบอินพุต\/เอาต์พุตเฉพาะภายในสถาปัตยกรรมการควบคุมแบบติดตั้งในแร็ค โมดูลนี้ช่วยให้สามารถแสดงผลข้อมูลเครื่องจักรสำคัญแบบเรียลไทม์โดยการส่งข้อมูลเซ็นเซอร์ที่ประมวลผลแล้วไปยังจอแสดงผลภายนอกโดยตรง\u003c\/p\u003e\n\u003cp\u003eทำหน้าที่เป็นส่วนประกอบสำคัญของระบบตรวจสอบ 3500 โมดูลแสดงผล I\/O นี้รับประกันการส่งสัญญาณวิดีโอที่มีความสมบูรณ์สูงโดยไม่ลดทอนความเร็วการประมวลผลของแผงหลัง การออกแบบที่แข็งแรงทนทานนี้เหมาะสำหรับสภาพแวดล้อมอุตสาหกรรมที่ท้าทาย ทำให้เหมาะสมสำหรับการใช้งานในกรอบการป้องกันทรัพย์สินสำคัญในอุตสาหกรรมหนักต่างๆ\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eให้การเดินสายสัญญาณที่เชื่อถือได้จากแร็คมอนิเตอร์ไปยังหน้าจอแสดงผลภายนอก\u003c\/li\u003e\n  \u003cli\u003eมีพอร์ตเชื่อมต่อความหนาแน่นสูงที่ออกแบบมาสำหรับสายเคเบิลระดับอุตสาหกรรม\u003c\/li\u003e\n  \u003cli\u003eรับประกันการแยกแผงหลังเพื่อปกป้องฟังก์ชันการตรวจสอบหลักจากความผิดพลาดทางไฟฟ้าฝั่งแสดงผลภายนอก\u003c\/li\u003e\n  \u003cli\u003eออกแบบขนาดกะทัดรัดแบบช่องเดียวเพื่อเพิ่มพื้นที่ภายในแร็คระบบ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eระบบตรวจสอบเครื่องจักรกลอุตสาหกรรม\u003c\/li\u003e\n  \u003cli\u003eอินเทอร์เฟซการแสดงผลท้องถิ่นในโรงกลั่นน้ำมัน ก๊าซ และปิโตรเคมี\u003c\/li\u003e\n  \u003cli\u003eการตั้งค่าการป้องกันกังหันและเครื่องกำเนิดไฟฟ้าในโรงไฟฟ้า\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eหมายเลขชิ้นส่วน\u003c\/strong\u003e\n      \u003ctd\u003e147663-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eประเภทโมดูล\u003c\/strong\u003e\n      \u003ctd\u003eโมดูลแสดงผล I\/O VGA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eความเข้ากันได้ของระบบ\u003c\/strong\u003e\n      \u003ctd\u003eระบบป้องกันเครื่องจักรชุด 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eประเทศต้นทาง\u003c\/strong\u003e\n      \u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eน้ำหนักจัดส่ง\u003c\/strong\u003e\n      \u003ctd\u003e2.0 กก.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eประเภทพอร์ต\u003c\/th\u003e\n      \u003cth\u003eฟังก์ชัน\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eอินเทอร์เฟซ VGA\u003c\/strong\u003e\n      \u003ctd\u003eส่งสัญญาณแสดงผลไปยังจอภาพภายนอกและเทอร์มินัลแสดงผล\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eตัวเชื่อมต่อแผงหลังแร็ค\u003c\/strong\u003e\n      \u003ctd\u003eรักษาความปลอดภัยการแลกเปลี่ยนข้อมูลและการจ่ายไฟจากตัวถังมอนิเตอร์\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eเพื่อให้การทำงานปลอดภัยและเชื่อถือได้ของ \u003cstrong\u003e147663-01\u003c\/strong\u003e, ปฏิบัติตามขั้นตอนการติดตั้งดังต่อไปนี้:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eปิดแร็คมอนิเตอร์ก่อนเสียบหรือถอดโมดูล I\/O เสมอเพื่อป้องกันการเกิดไฟฟ้ากระชาก\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าสกรูตัวถังโมดูลถูกขันแน่นเต็มที่เพื่อสร้างการเชื่อมต่อกราวด์ที่มั่นคงกับโครงแร็ค\u003c\/li\u003e\n  \u003cli\u003eจัดสายสัญญาณแสดงผลให้ห่างจากสายมอเตอร์แรงดันสูงเพื่อป้องกันการรบกวนทางแม่เหล็กไฟฟ้าที่อาจทำให้สัญญาณแสดงผลผิดเพี้ยน\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668310061419,"sku":"147663-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/147663-01-xny1mknzqbt_aaf6d777-24e6-45b5-b877-d65d0195a76d.jpg?v=1765520817"},{"product_id":"bently-nevada-3500-61-05-00-3500-series-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 3500\/61-05-00 ชุดโมดูล I\/O แบบ RTD\/TC ซีรีส์ 3500 แบบไม่แยกวงจร","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003eออกแบบมาเพื่อการรวมเข้ากับระบบป้องกันเครื่องจักร 3500 \u003cstrong\u003eBently Nevada 3500\/61-05-00\u003c\/strong\u003e ทำหน้าที่เป็นอินเทอร์เฟซอินพุต\/เอาต์พุต RTD\/TC แบบไม่แยกวงจรที่มีบาเรียร์ความปลอดภัยภายใน โมดูลนี้ทำงานร่วมกับเครื่องมอนิเตอร์อุณหภูมิ 3500\/61 เพื่อประมวลผลและส่งสัญญาณทรานสดิวเซอร์อุณหภูมิโดยตรงจากชิ้นส่วนเครื่องจักรไปยังระบบบันทึกภายนอก แผ่นบันทึก หรือคอนโทรลเลอร์กระบวนการ\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e3500\/61-05-00\u003c\/strong\u003e ช่วยให้การส่งสัญญาณเชื่อถือได้โดยให้เอาต์พุตเครื่องบันทึกที่ปรับสภาพแล้วซึ่งแสดงค่าที่วัดได้ โดยการรวมบาเรียร์ภายใน การกำหนดค่าฮาร์ดแวร์นี้ให้โซลูชันแบบบูรณาการสำหรับการปกป้องการเชื่อมต่อสายสนามในสภาพแวดล้อมอันตรายโดยไม่ต้องใช้ระบบบาเรียร์ภายนอกเสริม\u003c\/p\u003e\n\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eอินเทอร์เฟซโดยตรงสำหรับเครื่องตรวจจับอุณหภูมิแบบต้านทาน (RTD) และเทอร์โมคัปเปิล (TC)\u003c\/li\u003e\n  \u003cli\u003eบาเรียร์ความปลอดภัยภายในออกแบบมาเพื่อจำกัดพลังงานไฟฟ้าในพื้นที่อันตราย\u003c\/li\u003e\n  \u003cli\u003eให้เอาต์พุตเครื่องบันทึกแบบแอนะล็อกต่อเนื่องและสัดส่วนสำหรับการบันทึกข้อมูลและวิเคราะห์แนวโน้ม\u003c\/li\u003e\n  \u003cli\u003eการกำหนดค่า I\/O แบบไม่แยกวงจรที่เหมาะสำหรับการติดตั้งแร็คแบบรวมศูนย์ความหนาแน่นสูง\u003c\/li\u003e\n  \u003cli\u003eเข้ากันได้กับแร็คและแบ็คเพลนมาตรฐานของซีรีส์ 3500\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eตรวจสอบอุณหภูมิของกังหันไอน้ำและกังหันแก๊ส\u003c\/li\u003e\n  \u003cli\u003eป้องกันมอเตอร์อุตสาหกรรมขนาดใหญ่และขดลวดเครื่องกำเนิดไฟฟ้า\u003c\/li\u003e\n  \u003cli\u003eติดตามอุณหภูมิแบริ่งของคอมเพรสเซอร์และปั๊ม\u003c\/li\u003e\n  \u003cli\u003eอินเทอร์เฟซควบคุมกระบวนการปิโตรเคมีและการกลั่นน้ำมัน\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eหมายเลขชิ้นส่วน \/ รุ่น\u003c\/strong\u003e\n      \u003ctd\u003e3500\/61-05-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eซีรีส์\u003c\/strong\u003e\n      \u003ctd\u003eระบบป้องกันเครื่องจักร 3500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eประเภทโมดูล I\/O\u003c\/strong\u003e\n      \u003ctd\u003eโมดูล I\/O RTD\/TC แบบไม่แยกวงจรพร้อมบาเรียร์ภายใน\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eตัวเลือกการอนุมัติจากหน่วยงาน\u003c\/strong\u003e\n      \u003ctd\u003eไม่มี (ตัวเลือก 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eประเทศผู้ผลิต\u003c\/strong\u003e\n      \u003ctd\u003eสหรัฐอเมริกา\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eน้ำหนัก\u003c\/strong\u003e\n      \u003ctd\u003e0.91 กก.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eตรวจสอบให้แน่ใจว่าแร็คระบบ 3500 ปิดไฟอย่างสมบูรณ์ก่อนติดตั้งหรือถอดโมดูล I\/O\u003c\/li\u003e\n  \u003cli\u003eใส่ 3500\/61-05-00 เข้ากับด้านหลังของโครงเครื่องโดยจัดให้ตรงกับช่องการ์ดมอนิเตอร์ 3500\/61 ที่สอดคล้องกัน\u003c\/li\u003e\n  \u003cli\u003eขันสกรูแผงด้านหลังให้แน่นเพื่อยึดโมดูลและรักษาการเชื่อมต่อกราวด์ของโครงเครื่องอย่างถูกต้อง\u003c\/li\u003e\n  \u003cli\u003eตรวจสอบอิมพีแดนซ์ลูปและขีดจำกัดทางไฟฟ้าของบาเรียร์ก่อนเชื่อมต่อสายสนาม RTD หรือ TC\u003c\/li\u003e\n  \u003cli\u003eเดินสายเซ็นเซอร์แรงดันต่ำให้ห่างจากสายไฟฟ้าแรงสูงเพื่อป้องกันการรบกวนทางแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668312158571,"sku":"3500\/61-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-05-00-fsjtuqiluqx_b8e17e38-eef5-4988-a88a-22f12ff68c08.jpg?v=1765520885"},{"product_id":"bently-nevada-147364-01-3500-series-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 147364-01 โมดูล I\/O ไฟเบอร์ออปติก 100Base-FX ซีรีส์ 3500","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eเพื่ออำนวยความสะดวกในการสื่อสารความเร็วสูงและต้านทานเสียงรบกวนภายในแร็คป้องกันเครื่องจักร 3500, \u003cstrong\u003eBently Nevada 147364-01\u003c\/strong\u003e ทำหน้าที่เป็นอินเทอร์เฟซทางกายภาพสำหรับการเชื่อมต่ออีเธอร์เน็ตภายนอก โมดูล I\/O ไฟเบอร์ออปติก \u003cstrong\u003e100Base-FX\u003c\/strong\u003e นี้ติดตั้งที่ด้านหลังของแร็คโดยตรงต่อกับเกตเวย์สื่อสาร 3500\/92 เพื่อส่งผ่านข้อมูลวินิจฉัยและพารามิเตอร์การตรวจสอบเครื่องจักรที่สำคัญผ่านเครือข่ายแสง ด้วยการแทนที่การเชื่อมต่อทองแดงแบบดั้งเดิมด้วยไฟเบอร์ออปติก จึงให้การแยกไฟฟ้าอย่างสมบูรณ์และขจัดปัญหาวงจรกราวด์ในระบบเทเลเมทรี่อุตสาหกรรมที่ต้องการความแม่นยำสูง\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eมาตรฐาน 100Base-FX:\u003c\/strong\u003e ทำงานที่ความเร็ว 100 Mbps บนไฟเบอร์ออปติกมัลติโหมด\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eการแยกสัญญาณแสงอย่างสมบูรณ์:\u003c\/strong\u003e ป้องกันการรบกวนจากแม่เหล็กไฟฟ้า (EMI) และคลื่นความถี่วิทยุ (RFI) ที่ทำให้สัญญาณเสื่อมคุณภาพ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eตัวเชื่อมต่อ SC คู่:\u003c\/strong\u003e อินเทอร์เฟซโดยตรงสำหรับสายไฟเบอร์ TX และ RX เพื่อการเชื่อมต่อที่แข็งแรงและเชื่อถือได้\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eอินเทอร์เฟซเกตเวย์โดยตรง:\u003c\/strong\u003e ติดตั้งต่อเนื่องกับเกตเวย์ 3500\/92 เพื่ออำนวยความสะดวกในการสื่อสาร Modbus\/TCP หรืออีเธอร์เน็ตเฉพาะทางอย่างราบรื่น\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eโครงสร้างอุตสาหกรรมหนัก:\u003c\/strong\u003e ออกแบบให้ทนทานต่อสภาพแวดล้อมการทำงานที่รุนแรงของแผงหลัง\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eสถานีย่อยไฟฟ้าแรงสูงที่เครือข่ายทองแดงเสี่ยงต่อการเหนี่ยวนำไฟฟ้า\u003c\/li\u003e\n  \u003cli\u003eการติดตั้งตรวจสอบเครื่องจักรระยะไกลยาวถึงสองกิโลเมตรโดยไม่ต้องใช้เครื่องขยายสัญญาณ\u003c\/li\u003e\n  \u003cli\u003eโรงงานปิโตรเคมี น้ำมันและก๊าซ และโรงไฟฟ้าที่ต้องการสื่อส่งข้อมูลที่ปลอดประกายไฟ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eข้อกำหนดทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eพารามิเตอร์\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eข้อกำหนด\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eหมายเลขชิ้นส่วน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e147364-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eโปรโตคอลชั้นกายภาพ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100Base-FX (IEEE 802.3u)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eสื่อการส่งข้อมูล\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eไฟเบอร์ออปติกมัลติโหมด (62.5\/125 ไมครอน หรือ 50\/125 ไมครอน)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eตัวเชื่อมต่ออินเทอร์เฟซ\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eตัวเชื่อมต่อ SC คู่ (TX \/ RX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eความยาวคลื่นแสง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1300 นาโนเมตร\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eโมดูลเกตเวย์ที่เข้ากันได้\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3500\/92 ประตูสื่อสาร\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eช่วงอุณหภูมิการทำงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-30 องศาเซลเซียส ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 กก.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e245 มม. x 115 มม. x 25 มม.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eป้ายพอร์ต\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eฟังก์ชัน \/ ข้อกำหนดการเชื่อมต่อ\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eพอร์ตส่งสัญญาณแสง; ส่งสัญญาณแสงมัลติโหมดความยาวคลื่น 1300 นาโนเมตรไปยังเครื่องรับของสวิตช์เครือข่าย\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRX\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eพอร์ตรับสัญญาณแสง; รับสัญญาณแสงความยาวคลื่น 1300 นาโนเมตรจากเครื่องส่งสัญญาณของสวิตช์เครือข่าย\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eรุ่นทางเลือกและความเข้ากันได้\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eโมดูล I\/O ไฟเบอร์ออปติกมัลติโหมด 147364-01 เป็นทางเลือกโดยตรงแทนการ์ด I\/O แบบทองแดงของระบบ 3500\/92 เช่นที่ใช้การเชื่อมต่อ RJ45 (เช่น 100Base-TX) เมื่อเปลี่ยนจากการ์ด I\/O ทองแดงเป็น 147364-01 ให้ตรวจสอบว่าโมดูลเกตเวย์ 3500\/92 ด้านหน้าเครื่องมีเฟิร์มแวร์ที่รองรับการรู้จำอินเทอร์เฟซ 100Base-FX เพื่อป้องกันข้อผิดพลาดในการตั้งค่าในซอฟต์แวร์กำหนดค่าระบบ Bently Nevada 3500 Rack\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eข้อควรระวังและบันทึกทางวิศวกรรม\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eข้อผิดพลาดทั่วไปของวิศวกรไซต์คือพยายามเชื่อมต่อการ์ดมัลติโหมดนี้กับสายไฟเบอร์โหมดเดี่ยว (SM) สายไฟเบอร์โหมดเดี่ยวมาตรฐานมีแกนแคบกว่ามากและจะทำให้เกิดการลดทอนแสงสูง ส่งผลให้การสื่อสารล้มเหลวหรือการเชื่อมต่อ Link\/Act ขาดเป็นระยะ หากต้องการใช้งานโมดูลนี้บนโครงสร้างพื้นฐานโหมดเดี่ยว ต้องรวมตัวแปลงสื่อไฟเบอร์มัลติโหมดเป็นโหมดเดี่ยวที่ทนทานสำหรับอุตสาหกรรมภายนอก\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eคำแนะนำการติดตั้งและเดินสาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eตรวจสอบการแมปข้าม RX และ TX เสมอ พอร์ต TX บนโมดูล 147364-01 ต้องเชื่อมต่อโดยตรงกับพอร์ต RX ของอุปกรณ์เครือข่าย และในทางกลับกัน เก็บฝาครอบฝุ่นไฟเบอร์ออปติกไว้บนพอร์ต SC จนกว่าสายแพตช์จริงจะพร้อมเสียบ ฝุ่นละอองในอากาศซึ่งพบได้ทั่วไปในสภาพแวดล้อมอุตสาหกรรมอาจทำให้ภายในลำกล้องออปติกสกปรก ต้องทำความสะอาดด้วยผ้าเช็ดแห้งเฉพาะทางเพื่อคืนระดับ dB ปกติ\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eคำเตือนสำคัญ:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eอย่าเสียบหรือถอดโมดูล I\/O ด้านหลังขณะที่ระบบแร็ค 3500 ยังมีไฟฟ้าอยู่ การเกิดไฟกระชากที่ไม่ควบคุมอาจทำให้เกิดข้อผิดพลาดแผงหลังและความเสียหายทางกายภาพกับวงจรทรานซิสเตอร์ออปติกที่ไวต่อการกระทบกระเทือน ต่อกราวด์ตัวเองกับโครงเครื่องแร็คโดยใช้สายรัด ESD ก่อนจัดการฮาร์ดแวร์\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eปิดไฟจ่ายทั้งหมดของแร็ค 3500 และตรวจสอบด้วยโวลต์มิเตอร์ที่สอบเทียบแล้ว\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eจัดแนวโมดูลกับรางการ์ดในช่องแผงหลังที่อยู่ตรงกับเกตเวย์สื่อสาร 3500\/92 ที่เกี่ยวข้อง\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eเลื่อนโมดูลไปข้างหน้าอย่างระมัดระวังจนตัวเชื่อมต่อแผงหลังเข้าที่อย่างสมบูรณ์\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eขันสกรูล็อกที่แผงหน้าของโมดูล 147364-01 ให้แน่นเพื่อสร้างการต่อกราวด์กับโครงเครื่อง\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 4px;\"\u003eเปิดฝาครอบตัวเชื่อมต่อไฟเบอร์ออปติก SC และเชื่อมต่อสายเคเบิลมัลติโหมดกับพอร์ต\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314255723,"sku":"147364-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/147364-01-twfqfncmzfm_0702e495-201b-4242-8094-fb49f6be460b.jpg?v=1765520959"},{"product_id":"bently-nevada-176449-01-125680-01-3500-40m-proximitor-monitor-and-i-o-module","title":"Bently Nevada 176449-01+125680-01 เครื่องตรวจจับ Proximitor 3500\/40M และโมดูล I\/O","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eการทำงานฟังก์ชันป้องกันเครื่องจักรอย่างต่อเนื่องภายในระบบแร็ค 3500, \u003cstrong\u003eBently Nevada 176449-01+125680-01\u003c\/strong\u003e รวมโมดูลตรวจสอบ Proximitor 3500\/40M สี่ช่องกับโมดูล I\/O การต่อสายภายใน 125680-01 ชุดนี้ประมวลผลสัญญาณความถี่สูงจากโพรซิมิเตอร์เพื่อให้การวัดที่แม่นยำของการสั่นสะเทือนรัศมี, ตำแหน่งแรงดัน, ความเบี้ยว และการขยายตัวต่างระดับ โดยฝังการเชื่อมต่อเทอร์มินัลไว้บนการ์ด I\/O 125680-01 ช่วยลดความจำเป็นในการใช้บล็อกเทอร์มินัลภายนอก ลดขนาดตู้และทำให้การเดินสายภาคสนามที่ซับซ้อนในสภาพแวดล้อมที่ท้าทายง่ายขึ้น\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eสถาปัตยกรรมสี่ช่อง:\u003c\/strong\u003e การกำหนดค่าช่องอิสระรองรับการติดตามการสั่นสะเทือนรัศมี, แรงดันตามแกน และตำแหน่งเพลาพร้อมกัน\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eการต่อสายภายใน:\u003c\/strong\u003e การ์ดแบ็คเพลน 125680-01 มีบล็อกเทอร์มินัลเฉพาะบนโมดูลโดยตรง ช่วยให้การเดินสายลูปง่ายขึ้น\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eการปรับสัญญาณบนบอร์ด:\u003c\/strong\u003e รวมการแปลงสัญญาณอะนาล็อกเป็นดิจิทัลที่มีความแม่นยำสูงและการประมวลผลสัญญาณแบบไดนามิกเพื่อคำนวณค่าสูงสุดถึงต่ำสุดและค่าเฉลี่ย\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eโปรไฟล์สัญญาณเตือนที่ยืดหยุ่น:\u003c\/strong\u003e การกำหนดค่าระดับเตือนและอันตรายแยกอิสระสำหรับแต่ละช่องพร้อมเลือกเวลาหน่วงได้\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eการวินิจฉัยระบบครบวงจร:\u003c\/strong\u003e การตรวจสอบวงจรทรานสดิวเซอร์, แหล่งจ่ายไฟ และการทำงานภายในอย่างต่อเนื่องเพื่อกระตุ้นการเปลี่ยนสถานะรีเลย์ OK ทันที\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eการตรวจสอบการสั่นสะเทือนของตลับลูกปืนและตำแหน่งโรเตอร์ของกังหันไอน้ำและก๊าซ\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eการวิเคราะห์ไดนามิกโรเตอร์ของคอมเพรสเซอร์แรงดันสูงแบบแรงเหวี่ยง\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eการติดตามการสั่นสะเทือนของเกียร์บ็อกซ์อุตสาหกรรม, เครื่องเป่าลม และพัดลมหนัก\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eการป้องกันเครื่องจักรหมุนที่สำคัญในอุตสาหกรรมน้ำมันและก๊าซ, การผลิตไฟฟ้า และการแปรรูปปิโตรเคมี\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eพารามิเตอร์\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eค่าข้อมูลจำเพาะ\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eหมายเลขชิ้นส่วนโมดูลตรวจสอบ\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e176449-01 (3500\/40M)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eหมายเลขชิ้นส่วนโมดูล I\/O\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e125680-01 (การต่อสายภายใน)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eความเข้ากันได้ของระบบ\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eระบบตรวจสอบ Bently Nevada 3500\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eจำนวนช่อง\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 ช่องอิสระ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eรองรับทรานสดิวเซอร์อินพุต\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eโพรซิมิเตอร์ทรานสดิวเซอร์ (รวมถึงรุ่น 3300 XL ซีรีส์)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eช่วงสัญญาณ\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-24 VDC แหล่งจ่ายไฟลูปมาตรฐาน; เอาต์พุตโพรบระยะใกล้มาตรฐาน\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eประเภทการต่อสาย\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eแถบเทอร์มินัลภายใน (แบบหนีบสกรู)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eอุณหภูมิการทำงาน\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-30 ถึง +65 องศาเซลเซียส\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eสหรัฐอเมริกา (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10.0 กก. (รวมบรรจุภัณฑ์และโมดูล)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eการเชื่อมต่อและอินเทอร์เฟซ\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eป้ายบล็อกเทอร์มินัล\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eการกำหนดสัญญาณ \/ ฟังก์ชัน\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eช่อง 1 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eพลังงานทรานสดิวเซอร์ ช่อง 1, กราวด์ และสัญญาณส่งกลับ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eช่อง 2 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eพลังงานทรานสดิวเซอร์ ช่อง 2, กราวด์ และสัญญาณส่งกลับ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eช่อง 3 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eช่อง 3 จ่ายไฟทรานสดิวเซอร์ สายดิน และสัญญาณกลับ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eช่อง 4 PROX \/ COM \/ SIG\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eช่อง 4 จ่ายไฟทรานสดิวเซอร์ สายดิน และสัญญาณกลับ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eเทอร์มินัล SHLD\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eจุดต่อสายดินชิลด์เครื่องมือทั่วไป (แยกจากโครงเครื่อง)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eรุ่นทางเลือกและความเข้ากันได้\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eโมดูล I\/O 125680-01 ใช้เทอร์มินัลสกรูภายใน ซึ่งไม่เข้ากันทางกลกับแร็คที่ตั้งค่าสำหรับบล็อกสิ้นสุดภายนอก (ซึ่งใช้ชุดสายและโมดูล I\/O สิ้นสุดภายนอก 125680-02) เมื่อสลับหรือเปลี่ยนหน่วย 3500\/40 รุ่นเก่า ให้แน่ใจว่าเฟิร์มแวร์ของ 176449-01 ตรงกับเวอร์ชันที่ตั้งโปรแกรมในซอฟต์แวร์การตั้งค่าแร็ค 3500 ของคุณเพื่อป้องกันข้อผิดพลาดการจับคู่สล็อตและสถานะโมดูลถูกปิดกั้น\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eข้อควรระวังในการใช้งานและบันทึกทางวิศวกรรม\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eเนื่องจากสายสิ้นสุดภายในเชื่อมต่อโดยตรงกับการ์ด 125680-01 ที่ด้านหลังแร็ค จึงมีแรงกดทางกลโดยตรงที่ขั้วต่อแผงหลังของการ์ด ควรใช้สายรัดและถาดสายไฟที่แข็งแรงในตู้เพื่อช่วยลดแรงกดจากน้ำหนักภายนอก ตรวจสอบให้แน่ใจว่าน้ำหนักรวมในวงจรจ่ายไฟทรานสดิวเซอร์ -24 VDC ไม่เกินข้อกำหนดของระบบเมื่อใช้สายต่อยาวที่ไม่มาตรฐานหรือสายเซ็นเซอร์ระยะไกลที่กำหนดเอง\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eเคล็ดลับการเริ่มใช้งานและการเดินสาย\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eต่อสายดินชิลด์ของสายเซ็นเซอร์ที่เทอร์มินัล SHLD เฉพาะบนโมดูล 125680-01 เสมอ ห้ามต่อสายดินชิลด์ทั้งสองด้านเพราะจะทำให้เกิดวงจรดินซึ่งรบกวนการวัดระยะใกล้แรงดันต่ำด้วยสัญญาณรบกวน 50\/60 Hz ก่อนเริ่มใช้งาน ให้ตรวจสอบว่าสเกลแฟกเตอร์ของทรานสดิวเซอร์ที่ตั้งค่าไว้ (เช่น 7.87 V\/mm \/ 200 mV\/mil) ตรงกับสเกลแฟกเตอร์ที่สอบเทียบของเซ็นเซอร์ Proximitor ที่ติดตั้ง\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eคำเตือนสำคัญ: ความปลอดภัยมาก่อน\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003eปิดระบบไฟฟ้าทั้งหมดของแร็ค 3500 ก่อนใส่หรือถอดการ์ด I\/O 125680-01 การสลับชิ้นส่วนแผงหลังขณะมีโหลดอาจทำให้เกิดความผิดพลาดทางไฟฟ้าชั่วคราวซึ่งอาจกระตุ้นคำสั่งหยุดเครื่องจักรผิดพลาด ควรต่อสายดินตัวเองผ่านสายรัดข้อมือ ESD ในระหว่างการติดตั้ง\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eใส่โมดูลมอนิเตอร์ 176449-01 ลงในสล็อตที่เลือกด้านหน้าของแร็ค 3500 ให้แน่ใจว่าแท็บดึงล็อกแน่นในตำแหน่ง\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eจัดตำแหน่งโมดูล I\/O การสิ้นสุดภายใน 125680-01 ให้ตรงกับรางนำทางสล็อตด้านหลังที่ตรงกัน แล้วดันให้แน่นจนแผงวงจรเข้าที่เชื่อมต่อกับแผงหลังอย่างเต็มที่ จากนั้นขันสกรูนิ้วด้านหลังให้แน่น\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eเชื่อมต่อสายไฟภาคสนามกับเทอร์มินัลสกรูภายใน โดยยึดสายดรนชิลด์กับเทอร์มินัล SHLD ที่กำหนดสำหรับแต่ละช่อง\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eเปิดระบบไฟฟ้า เชื่อมต่อกับซอฟต์แวร์การตั้งค่าแร็ค 3500 อัปโหลดโปรไฟล์สล็อตที่ถูกต้อง และทำการตรวจสอบวงจรลูปในช่องทรานสดิวเซอร์ที่ใช้งานทั้งหมด\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668314681707,"sku":"176449-01+125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/176449-01125680-01-i41d31qoc4g_a0c10ff9-b365-4890-8b40-c40c213b16c7.jpg?v=1765520974"},{"product_id":"bently-nevada-135489-02-i-o-module-with-internal-barriers-for-prox-accel-and-velomitor-signals","title":"โมดูล Bently Nevada 135489-02 I\/O พร้อมอุปสรรคภายในสำหรับสัญญาณ Prox\/Accel และ Velomitor","description":"\u003ch3\u003eภาพรวมผลิตภัณฑ์\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e135489-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eเป็นโมดูล Bently Nevada I\/O ที่ออกแบบมาเพื่อการรับสัญญาณอย่างปลอดภัยจากเซ็นเซอร์ระยะใกล้, เซ็นเซอร์เร่งความเร็ว และเซ็นเซอร์ความเร็วในระบบตรวจสอบการสั่นสะเทือนในอุตสาหกรรม โมดูลนี้รวมอุปสรรคภายในและการสิ้นสุดสัญญาณภายในเพื่อทำให้สถาปัตยกรรมการเดินสายง่ายขึ้นในขณะที่ยังคงความปลอดภัยภายในตัวในพื้นที่อันตราย โมดูลนี้มักใช้ในระบบป้องกันกังหัน, คอมเพรสเซอร์ และเครื่องจักรหมุนที่สำคัญซึ่งต้องการอินพุตการสั่นสะเทือนหลายช่องที่เชื่อถือได้สำหรับการตรวจสอบสภาพอย่างต่อเนื่อง\u003c\/p\u003e\n\u003cp\u003eโมดูล I\/O นี้รองรับช่องสัญญาณ Proximity หรือ Accelerometer จำนวน 2 ช่อง และช่อง Velomitor จำนวน 2 ช่อง ทำให้สามารถกำหนดค่าผสมของเซ็นเซอร์ภายในโมดูลเดียวได้อย่างยืดหยุ่น มันถูกใช้อย่างแพร่หลายในสถานีผลิตน้ำมันและก๊าซ, โรงไฟฟ้า และโรงงานปิโตรเคมีที่ความน่าเชื่อถือของระบบและความซับซ้อนของการเดินสายที่ลดลงส่งผลโดยตรงต่อประสิทธิภาพการบำรุงรักษาและการควบคุมเวลาหยุดทำงาน\u003c\/p\u003e\n\u003ch3\u003eการกำหนดค่าทางเทคนิค\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eช่อง Prox\/Accel จำนวน 2 ช่อง สำหรับการตรวจสอบการสั่นสะเทือนและการเคลื่อนที่ของเพลา\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eช่อง Velomitor จำนวน 2 ช่อง สำหรับการวัดความเร็วการสั่นสะเทือนของตัวเครื่อง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eอุปสรรคภายในสำหรับการแยกสัญญาณความปลอดภัยภายในตัว\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eการสิ้นสุดสัญญาณภายในเพื่อการเดินสายตู้ควบคุมที่ง่ายขึ้นและลดความซับซ้อนในการติดตั้ง\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eการออกแบบอุปสรรคภายในช่วยขจัดความจำเป็นในการใช้ตัวแยกสัญญาณภายนอก ลดความต้องการพื้นที่ในตู้ควบคุมและเพิ่มประสิทธิภาพการรวมระบบ โมดูลนี้รับประกันการปรับสัญญาณที่เสถียรระหว่างเซ็นเซอร์ภาคสนามและระบบตรวจสอบในขณะที่ยังคงการป้องกันทางไฟฟ้าในสภาพแวดล้อมที่เป็นอันตราย\u003c\/p\u003e\n\u003ch3\u003eข้อมูลจำเพาะทางเทคนิค\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth class=\"\"\u003eรายละเอียด\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eรุ่น\u003c\/td\u003e\n\u003ctd\u003e135489-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแบรนด์\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทผลิตภัณฑ์\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O พร้อมอุปสรรคภายใน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eแหล่งกำเนิด\u003c\/td\u003e\n\u003ctd\u003eผลิตในสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eช่องสัญญาณอินพุต\u003c\/td\u003e\n\u003ctd\u003e2 Prox\/Accel + 2 Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eอินพุตการเคลื่อนที่และความเร็วการสั่นสะเทือน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eคุณสมบัติความปลอดภัย\u003c\/td\u003e\n\u003ctd\u003eอุปสรรคความปลอดภัยภายในตัว\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการสิ้นสุดสัญญาณ\u003c\/td\u003e\n\u003ctd\u003eการสิ้นสุดสัญญาณภายใน\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการใช้งาน\u003c\/td\u003e\n\u003ctd\u003eการตรวจสอบกังหัน, คอมเพรสเซอร์, ปั๊ม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eสภาพแวดล้อมการทำงาน\u003c\/td\u003e\n\u003ctd\u003eพื้นที่อุตสาหกรรมที่เป็นอันตราย\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eการใช้พลังงาน\u003c\/td\u003e\n\u003ctd\u003eใช้พลังงานจากระบบแร็ค\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนัก\u003c\/td\u003e\n\u003ctd\u003e0.201 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eน้ำหนักรวมจัดส่ง\u003c\/td\u003e\n\u003ctd\u003e2 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eประเภทการติดตั้ง\u003c\/td\u003e\n\u003ctd\u003eโมดูล I\/O ติดตั้งบนแร็ค\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eคำถามที่พบบ่อยทางเทคนิค\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้สามารถจัดการสัญญาณระยะใกล้และความเร็วพร้อมกันได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eได้ รองรับอินพุต Proximity หรือ Accelerometer จำนวน 2 ช่อง และช่อง Velomitor ความเร็ว 2 ช่องพร้อมกัน\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eโมดูลนี้ต้องการอุปสรรคสัญญาณภายนอกหรือไม่?\u003c\/strong\u003e\u003cbr\u003eไม่ ต้องมีอุปสรรคภายในตัว ซึ่งช่วยลดการเดินสายภายนอกและความซับซ้อนของตู้ควบคุม\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eสามารถใช้งานร่วมกับระบบตรวจสอบ 3500 ได้หรือไม่?\u003c\/strong\u003e\u003cbr\u003eได้ ออกแบบมาเพื่อการรวมเข้ากับสถาปัตยกรรมระบบตรวจสอบ Bently Nevada 3500 ซีรีส์\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถ้าช่องสัญญาณใดล้มเหลวจะเกิดอะไรขึ้น?\u003c\/strong\u003e\u003cbr\u003eช่องที่ล้มเหลวจะทำให้ระบบตรวจสอบแจ้งเตือนการวินิจฉัยโดยไม่ส่งผลกระทบต่อช่องสัญญาณที่เหลือ\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eคู่มือวิศวกรรมและการติดตั้ง\u003c\/h3\u003e\n\u003cp\u003eติดตั้งโมดูลในตู้แร็คที่มีการต่อสายดินอย่างถูกต้องเพื่อรักษาความสมบูรณ์ของสัญญาณและความปลอดภัยภายในตัว การต่อสายดินที่ไม่ดีอาจทำให้เกิดสัญญาณรบกวนในการวัดในทุกช่องสัญญาณ\u003c\/p\u003e\n\u003cp\u003eแยกสายไฟภาคสนามออกจากสายไฟแรงดันสูงและสาย VFD เพื่อหลีกเลี่ยงการรบกวนทางแม่เหล็กไฟฟ้า โดยเฉพาะในตู้ควบคุมกังหัน\u003c\/p\u003e\n\u003cp\u003eตรวจสอบการกำหนดค่าช่องสัญญาณให้ถูกต้องในระหว่างการเริ่มใช้งาน การกำหนดค่าประเภทอินพุตผิด (Prox\/Accel กับ Velomitor) อาจทำให้การตีความการสั่นสะเทือนผิดพลาด\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321890667,"sku":"135489-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-02-i-o-module-with-internal-barriers-and-internal-terminations-ph4wmoxwykw_33e1082e-42c4-4eda-8942-5a692bc45121.jpg?v=1765449578"},{"product_id":"bently-nevada-3500-22m-01-01-00-transient-data-interface-with-ethernet-i-o","title":"Bently Nevada 3500\/22M-01-01-00 | อินเทอร์เฟซข้อมูลชั่วคราวพร้อมพอร์ต Ethernet I\/O","description":"\u003ch3\u003eภาพรวม\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Transient Data Interface) คือโปรเซสเซอร์สื่อสารและเก็บข้อมูลเฉพาะสำหรับระบบป้องกันเครื่องจักร Bently Nevada 3500 ซีรีส์ แตกต่างจาก 3500\/20 RIM รุ่นมาตรฐาน ซีรีส์ \"M\" TDI มอบความสามารถในการจับคลื่นสัญญาณขั้นสูงและวิเคราะห์ข้อมูลชั่วคราวความละเอียดสูง โมดูลนี้เป็นตัวเชื่อมสำคัญระหว่างแผงวงจรภายในแร็คและซอฟต์แวร์วินิจฉัยภายนอก เช่น System 1 ช่วยให้สามารถตรวจสอบเครื่องจักรหมุนที่สำคัญแบบเรียลไทม์ได้\u003c\/p\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eแบรนด์:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eรหัสรุ่น:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eประเภทฮาร์ดแวร์:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eโมดูลและ I\/O Transient Data Interface (TDI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการกำหนดค่า TDI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(มาตรฐาน - ออกแบบสำหรับการตรวจสอบเครื่องจักรทั่วไป)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eอินเทอร์เฟซ I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(โมดูล I\/O Ethernet 10Base-T\/100Base-TX)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการรับรองจากหน่วยงาน:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOption\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ไม่มี \/ ใช้งานทั่วไป)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการเชื่อมต่อ Ethernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eอินเทอร์เฟซ RJ45 แบบทองแดง รองรับ 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eอัตราการรีเฟรชข้อมูล:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eข้อมูลคงที่อัปเดตทุก 100 มิลลิวินาที\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eการจัดเก็บ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eหน่วยความจำภายในแบบไม่ลบข้อมูลสำหรับการกำหนดค่าและบันทึกเหตุการณ์\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eประเทศที่ผลิต:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eผลิตในสหรัฐอเมริกา\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eน้ำหนักสุทธิของสินค้า:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.11 กก.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eน้ำหนักรวมจัดส่ง:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.0 กก.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eบทบาทการทำงานและการบูรณาการ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eติดตั้งในช่องแรกของแร็ค 3500 ใกล้กับแหล่งจ่ายไฟ ทำหน้าที่ดึงข้อมูลจากเครื่องวัดการสั่นสะเทือน ตำแหน่ง และอุณหภูมิทั้งหมดภายในแร็คอย่างต่อเนื่อง โดยใช้ I\/O Ethernet 10\/100 เพื่อให้มั่นใจว่าคลื่นสัญญาณไดนามิกที่มีแบนด์วิดท์สูงถูกส่งโดยไม่มีความล่าช้า ซึ่งสำคัญต่อการระบุความไม่เสถียรของโรเตอร์หรือการสึกหรอของแบริ่งในช่วงสถานะเครื่องจักรชั่วคราว (เช่น การสตาร์ท การปิดเครื่อง หรือการเปลี่ยนความเร็ว)\u003c\/p\u003e\n\u003ch3\u003eคำถามที่พบบ่อย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: 3500\/22M-01-01-00 สามารถใช้งานร่วมกับแร็ค 3500 รุ่นเก่าได้หรือไม่?\u003c\/strong\u003eตอบ: ได้ \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eออกแบบให้เข้ากันได้กับแร็ค 3500 รุ่นเก่า ตราบใดที่แผงวงจรหลังแร็ครองรับสถาปัตยกรรม TDI และเป็นการอัปเกรดที่แนะนำสำหรับโมดูล 3500\/20 รุ่นเก่า\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eถาม: การรับรองหน่วยงาน \"00\" จำกัดประสิทธิภาพของโมดูลหรือไม่?\u003c\/strong\u003eตอบ: ไม่ใช่ \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eหมายความว่าอุปกรณ์ไม่มีการรับรองสำหรับพื้นที่อันตรายเฉพาะ (เช่น CSA หรือ ATEX) แต่มีประสิทธิภาพทางเทคนิคเทียบเท่ากับอุปกรณ์ที่ได้รับการรับรอง เหมาะสำหรับห้องควบคุมหรือสภาพแวดล้อมอุตสาหกรรมที่ไม่จัดประเภท\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322742635,"sku":"3500\/22M-01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022m-01-01-00-dak4rp3gmkm_003a628d-19ea-4202-a869-d6aedfb09e6a.jpg?v=1765521208"},{"product_id":"abb-spfec12-symphony-plus-hr-i-o-analog-input-module","title":"ABB SPFEC12 ซิมโฟนี พลัส HR โมดูลอินพุตอนาล็อก I\/O","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eABB \u003cstrong\u003eSPFEC12\u003c\/strong\u003e เป็นโมดูลอินพุตแอนะล็อกความละเอียดสูงและความหนาแน่นสูงที่ออกแบบมาเพื่อการเก็บสัญญาณกระบวนการภายในระบบควบคุมแบบกระจาย Symphony Plus อุปกรณ์ฮาร์ดแวร์นี้ประมวลผลสัญญาณภาคสนามต่อเนื่องจากเครื่องส่งสัญญาณ แปลงตัวแปรแอนะล็อกเป็นข้อมูลดิจิทัลที่แม่นยำสำหรับโปรเซสเซอร์กลาง โดยมีการแยกทางไฟฟ้าและการกรองสัญญาณในแต่ละช่องสัญญาณ โมดูลนี้ช่วยแยกแผงควบคุมเครือข่ายจากสัญญาณไฟฟ้าชั่วคราวแรงดันสูงในภาคสนาม ลดการลอยของการวัดในสภาพแวดล้อมอุตสาหกรรมที่มีสัญญาณรบกวนทางไฟฟ้า\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eการประมวลผลสัญญาณความละเอียดสูง:\u003c\/strong\u003e แปลงกระแสหรือแรงดันแอนะล็อกต่อเนื่องเป็นค่าดิจิทัลละเอียดสูงสำหรับวงจรสำคัญ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eสถาปัตยกรรม S+ HR I\/O:\u003c\/strong\u003e เข้ากันได้อย่างสมบูรณ์กับบัสสื่อสารแผงอินพุต\/เอาต์พุตความละเอียดสูง Symphony Plus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการแยกช่องสัญญาณ:\u003c\/strong\u003e ปกป้องวงจรประมวลผลภายในแรงดันต่ำจากวงจรกราวด์ภาคสนามภายนอกและความผันผวนของแรงดันโหมดทั่วไป\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n\u003cli\u003eเชื่อมต่อกับเครื่องส่งสัญญาณกระบวนการ 4-20mA ที่ตรวจวัดแรงดัน อุณหภูมิ และอัตราการไหลปริมาตร\u003c\/li\u003e\n\u003cli\u003eการตรวจสอบตัวแปรความถี่สูงอย่างต่อเนื่องในกระบวนการผลิตไฟฟ้าและการบำบัดน้ำหนัก\u003c\/li\u003e\n\u003cli\u003eอัปเกรดบล็อกอินพุต Harmony หรือ INFI 90 รุ่นเก่าเป็นเฟรมเวิร์กการควบคุมแบบกระจาย Symphony Plus ความละเอียดสูง\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eพารามิเตอร์\u003c\/th\u003e\n\u003cth style=\"padding: 10px; font-weight: bold;\"\u003eค่า\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eผู้ผลิต\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eกลุ่มผลิตภัณฑ์\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSymphony Plus (S+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eหมายเลขรุ่น\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eSPFEC12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเภทฮาร์ดแวร์\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eโมดูลอินพุตแอนะล็อกความละเอียดสูง\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eประเทศต้นทาง\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eสหรัฐอเมริกา\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eน้ำหนักจัดส่ง (คำนวณ)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e0.65 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eขนาดบรรจุภัณฑ์ (คำนวณ)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e220 x 150 x 50 มม.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d;\"\u003eแนวทางการติดตั้ง\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n\u003cstrong\u003eคำเตือนสำคัญ:\u003c\/strong\u003e แยกแหล่งจ่ายไฟวงจรเครื่องมือภาคสนามภายนอกทั้งหมดก่อนการติดตั้งโมดูล การทำงานบนแผง I\/O ที่มีไฟฟ้าสดโดยไม่มีการควบคุมกระบวนการที่เหมาะสมอาจทำให้เกิดสัญญาณชั่วคราวที่กระตุ้นให้ระบบความปลอดภัยทำงานผิดปกติหรือปิดอุปกรณ์\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eตรวจสอบพินจัดตำแหน่งโมดูลด้านหลังและวางการ์ดให้ตรงกับรางนำของซับแร็ค Symphony Plus ความละเอียดสูงอย่างแม่นยำ\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eกดอย่างต่อเนื่องและสม่ำเสมอจนแผงหน้าการ์ดล็อคเข้ากับตัวเชื่อมต่อแผงหลังอย่างสมบูรณ์ ดึงสกรูกราวด์ให้แน่นเพื่อให้แน่ใจว่ามีความต่อเนื่องของตัวเรือน\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"color: #2d3748;\"\u003eตรวจสอบสถานะการทำงานของไฟ LED สถานะที่แผงด้านหน้าเพื่อยืนยันว่าการกำหนดค่ารางจ่ายไฟภายในและลิงก์การสื่อสารมีความเสถียร\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668496249195,"sku":"SPFEC12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-spfec12-analog-input-module-bikrzikfpsj_0d213da1-759e-4e11-a093-88bd75d57500.jpg?v=1765532355"},{"product_id":"abb-ndio-02-option-sp-kit-rep58976059-digital-i-o-extension","title":"ชุดตัวเลือก ABB NDIO-02 OPTION\/SP KIT REP58976059 ขยายดิจิทัล I\/O","description":"\u003ch3\u003eคำอธิบาย\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNDIO-02 OPTION\/SP KIT\u003c\/strong\u003e (รหัสสินค้า: \u003cstrong\u003eREP58976059\u003c\/strong\u003e) เป็นชุดขยายดิจิทัล I\/O ที่ออกแบบมาสำหรับไดรฟ์ AC อุตสาหกรรมแรงดันต่ำ บอร์ดตัวเลือกขยายนี้ให้ความสามารถในการรับและส่งสัญญาณดิจิทัลเพิ่มเติมโดยตรงกับโครงสร้างตัวควบคุมไดรฟ์ ช่วยให้สามารถตรวจสอบอุปกรณ์ต่อพ่วงอัตโนมัติได้กว้างขึ้น รับข้อมูลย้อนกลับ และประสานงานวงจรภายนอกได้อย่างมีประสิทธิภาพ พัฒนาเป็นโมดูลแบบบูรณาการที่รักษาความเข้ากันได้ของสัญญาณเต็มรูปแบบภายในสถาปัตยกรรมไดรฟ์รุ่นเก่า โดยเฉพาะอย่างยิ่งสำหรับระบบมัลติไดรฟ์ เช่น ซีรีส์ ACS600 Multidrives\u003c\/p\u003e\n\u003ch3\u003eคุณสมบัติ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eขยายความสามารถของอินเทอร์เฟซ\u003c\/strong\u003e: เพิ่มขีดความสามารถในการควบคุมในพื้นที่โดยการเพิ่มช่องสัญญาณดิจิทัลอิสระเพิ่มเติมเข้าสู่โครงสร้างการประมวลผล\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรวมเข้ากับไดรฟ์โดยตรง\u003c\/strong\u003e: ติดตั้งเข้ากับช่องบอร์ดตัวเลือกภายในที่กำหนดไว้โดยไม่ต้องใช้พื้นที่ติดตั้งภายนอก\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eบำรุงรักษาระบบย่อยรุ่นเก่า\u003c\/strong\u003e: ทำหน้าที่เป็นอะไหล่ซ่อมแซมที่ได้รับการรับรองมาตรฐานเพื่อยืดอายุการใช้งานของโครงสร้างมัลติไดรฟ์อุตสาหกรรมที่มีอยู่\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eการใช้งาน\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eการตั้งค่าระบบ ACS600 Multidrives\u003c\/strong\u003e: ใช้เป็นอุปกรณ์ต่อพ่วงฮาร์ดแวร์เฉพาะในชุด ACW610 ที่ระบายความร้อนด้วยน้ำ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการรวมไดรฟ์ AC แรงดันต่ำ\u003c\/strong\u003e: ใช้ในตู้ไดรฟ์ความเร็วแปรผันรุ่นเก่าที่ต้องการการปรับขนาดสัญญาณแยกต่างหาก\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eการเชื่อมต่อระบบอัตโนมัติในกระบวนการ\u003c\/strong\u003e: ใช้สำหรับการเดินสายสวิตช์จำกัดระยะไกล อินเตอร์ล็อก และตัวบ่งชี้สถานะการทำงานดิจิทัล\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eข้อมูลทางเทคนิค\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eพารามิเตอร์\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eค่า\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eผู้ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสรุ่น\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNDIO-02 OPTION\/SP KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eREP58976059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eชื่อสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIGITAL I\/O EXTEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเภทชิ้นส่วน\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eอะไหล่ \/ ชิ้นส่วนซ่อม\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eความเข้ากันได้ของระบบ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eACS600 Multidrives Water Cooled (ACW610)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eประเทศที่ผลิต\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eสวีเดน (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eรหัสอัตราภาษีศุลกากร\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eน้ำหนักสุทธิสินค้า\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 กก.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eขนาด (ก x ส x ล)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 มม. x 95 มม. x 30 มม. (ประมาณ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eคำแนะนำการติดตั้ง\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eแยกสายไฟ AC หลักและวงจรจ่ายไฟแรงดันสูงทั้งหมดออกจากตู้ก่อนทำการบำรุงรักษา\u003c\/li\u003e\n\u003cli\u003eปล่อยให้ตัวเก็บประจุ DC ลิงก์ภายในไดรฟ์คายประจุจนหมดตามระยะเวลาความปลอดภัยของอุปกรณ์หลัก\u003c\/li\u003e\n\u003cli\u003eติดตั้งบอร์ดตัวเลือกโมดูลอย่างแน่นหนาในช่องที่กำหนดบนโครงตัวควบคุมเพื่อสร้างเส้นทางกราวด์ไฟฟ้าที่มั่นคงผ่านจุดยึด\u003c\/li\u003e\n\u003cli\u003eยึดสายสัญญาณอินเทอร์เฟซอย่างแน่นหนากับบล็อกเทอร์มินัล แยกสายลอจิกออกจากสายจ่ายไฟแรงสูงที่อยู่ใกล้เคียงเพื่อลดความเสี่ยงจากสัญญาณรบกวนแม่เหล็กไฟฟ้า\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668497166699,"sku":"NDIO-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ndio-02-64129007-digital-i-o-extension-module-4odpuvdg3ts_dbb1f0ca-3a7f-4b1d-8f3f-d518b9e6c100.jpg?v=1765532441"}],"url":"https:\/\/www.plcprotech.com\/th\/collections\/i-o-modules.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}