{"title":"Yokogawa ProSafe-RS","description":"\u003cp\u003eYokogawa ProSafe-RS is a safety instrumented system (SIS) specifically engineered for high-integrity process protection. The architecture is based on a SIL3-certified redundant design, featuring specialized safety control units (SCP461) and safety I\/O modules (SDV144). Technical characteristics include the use of Vnet\/IP for seamless integration with \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/yokogawa-centum-vp\"\u003eCENTUM VP\u003c\/a\u003e, self-diagnostic circuitry, and SNT10 network modules for safety communication. Functionally, ProSafe-RS handles Emergency Shutdown (ESD) and Fire and Gas (F\u0026amp;G) logic, ensuring that hazardous process conditions are safely mitigated. Its non-interfering communication with the DCS allows for a unified operation environment while maintaining the strict independence required for international safety standards.\u003c\/p\u003e","products":[{"product_id":"yokogawa-sdv531-s33-prosafe-rs-digital-output-module","title":"Yokogawa SDV531-S33 ProSafe-RS Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SDV531-S33\u003c\/strong\u003e is an 8-channel, 24 V DC safety-related \u003cstrong\u003edigital output module\u003c\/strong\u003e designed for integration into Yokogawa ProSafe-RS safety instrumented systems (SIS). This high-reliability module provides galvanic module isolation and outputs discrete ON\/OFF status signals to safeguard and control critical field equipment.\u003c\/p\u003e\n\u003cp\u003eEquipped with autonomous field wiring diagnostic functions, the \u003cstrong\u003eYokogawa SDV531-S33\u003c\/strong\u003e actively protects process environments. When a short-circuit fault occurs on the field side, the module automatically drives the corresponding output channel to an OFF state. After the line fault is cleared, the output channel can be securely restored via an intentional system Output Enable Operation to resume running application logic values. Without this deliberate enable command, the channel remains locked in its designated fail-safe value to ensure plant security.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 isolated current-source digital output channels \u003c\/li\u003e\n\u003cli\u003eIntegrated field wiring diagnostic functions without external adapters \u003c\/li\u003e\n\u003cli\u003eAutomatic channel de-activation (OFF state) upon field-side short-circuit detection\u003c\/li\u003e\n\u003cli\u003eConditional safety recovery protocol requiring an explicit Output Enable Operation\u003c\/li\u003e\n\u003cli\u003eFail-safe value enforcement for unrecovered or compromised output lines\u003c\/li\u003e\n\u003cli\u003eCompliant with ISA Standard G3 for advanced environmental corrosion resistance \u003c\/li\u003e\n\u003cli\u003eRobust wide-range thermal protection qualified for operation between -20 and 70 degC \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Systems (FGS)\u003c\/li\u003e\n\u003cli\u003eCritical Interlock Loops in Oil, Gas, and Chemical Processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDV531\u003c\/td\u003e\n\u003ctd\u003e\u003ci\u003e---\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital output module (8-channel, 24 V DC, module isolation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e---\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e---\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eWith signal cable interface adapter and no explosion protection? (Note: User configuration overrides to 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003e---\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 and temperature (-20 to 70 degC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS FIO Systems \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8-channel, module isolation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1 V maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent source \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC +20%\/-10%, current capacity: 5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Rating\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 5 A minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leak Current (Output OFF)\u003c\/td\u003e\n\u003ctd\u003e1.6 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.6 A per output line (4.8 A total for all output lines) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e35 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance Range\u003c\/td\u003e\n\u003ctd\u003e40 to 685 Ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e30 ms maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between output signal lines and system for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e280 mA maximum (5 V DC), 140 mA maximum (24 V DC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.34 kg (With dedicated signal cable interface adapter) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 32.8 mm x 124 mm (Module depth 130 mm, height 124 mm, width 32.8 mm with interface adapter) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDedicated signal cable (AKB331) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Cable Interface Adapter\u003c\/td\u003e\n\u003ctd\u003eConnects to the field side via dedicated signal cable AKB331 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Side Interface\u003c\/td\u003e\n\u003ctd\u003eInternal bus communication matching the Safety Node Unit \/ Safety Control Unit slots \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Install the module into a certified slot of the Safety Node Unit or Safety Control Unit. Ensure the module is properly seated and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Oversight:\u003c\/strong\u003e Ensure cabinet ventilation keeps the local environment within the certified -20 to 70 degC range, preventing thermal stagnation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Restrictions:\u003c\/strong\u003e When utilizing this specific interface adapter configuration, option codes for pressure clamp terminal blocks and MIL cable connectors are incompatible and must not be used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Considerations:\u003c\/strong\u003e For optimum noise immunity and reliable safety metrics, floating the field power supply is recommended. If grounded, note that the functional system ground links directly to the field ground.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695382589803,"sku":"SDV531-S33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-sdv531-s33-digital-output-module-x0ev3urspgg_3a364813-ed7a-405d-ab15-e7929bd349f5.jpg?v=1766132483"},{"product_id":"yokogawa-sai143-s33-prosafe-rs-analog-input-module","title":"Yokogawa SAI143-S33 ProSafe-RS Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SAI143-S33\u003c\/strong\u003e is a high-reliability current input module designed for mounting on the safety node unit and safety control unit within the \u003cstrong\u003eProSafe-RS\u003c\/strong\u003e safety instrumented system. This module plays a critical role in safety functions by inputting 4 to 20 mA signals from field instruments directly into the Safety Control Station (SCS). It supports dual-redundant configurations to achieve enhanced system availability and fault tolerance. The \u003cstrong\u003eSAI143-S33\u003c\/strong\u003e features standard individual channel configuration pins for 2-wire or 4-wire transmitters and provides module isolation for its 16 processing channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Redundancy:\u003c\/strong\u003e Supports full dual-redundant configuration to eliminate single points of failure in safety-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Sensor Hookup:\u003c\/strong\u003e Individual channel setting via pins to accommodate both 2-wire and 4-wire field transmitter arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous Power Management:\u003c\/strong\u003e Built-in transmitter power supply ON\/OFF function across all 16 channels simultaneously, facilitating alarm resets for Fire and Gas devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e Delivers module-level galvanic isolation protecting internal system electronics from hazardous field transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS) \u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) System integration and device resetting \u003c\/li\u003e\n\u003cli\u003eProcess industry safety monitoring and critical current loop sourcing \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 14.1439%; height: 39.1875px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 13.2878%; height: 39.1875px;\"\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 67.985%; height: 39.1875px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 14.1439%; height: 39.1875px;\"\u003e\u003cstrong\u003eSAI143\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 13.2878%; height: 39.1875px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 67.985%; height: 39.1875px;\"\u003eAnalog Input Module (4 to 20 mA, 16 channels, module isolation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.1439%; height: 19.5938px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 13.2878%; height: 19.5938px;\"\u003e-S\u003c\/td\u003e\n\u003ctd style=\"width: 67.985%; height: 19.5938px;\"\u003eStandard type \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 14.1439%; height: 19.5938px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 13.2878%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 67.985%; height: 19.5938px;\"\u003eFor pressure clamp terminal block or MIL cable with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 14.1439%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 13.2878%; height: 39.1875px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 67.985%; height: 39.1875px;\"\u003eWith ISA Standard G3 and temperature (-20 to 70 degC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSAI143-S33 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels, module isolation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 25 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Power-ON)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Ohm + Voltage drop in the input protection circuit inside the module \/ Current value \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (Power-OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Ohm minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 V (in the input protection circuit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 uA (Input range 1 to 23 mA for Style S3) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 uA\/10 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.15 V minimum (at 20 mA), 26.4 V maximum (at 0 mA) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC between input signal and system for 1 minute \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V system: 320 mA, 24 V system: 550 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.34 kg (For pressure clamp terminal block or MIL cable) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.8 mm x 130 mm x 107.5 mm (For pressure clamp and MIL cable) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Siting:\u003c\/strong\u003e Mount the current input module onto a compatible safety node unit or safety control unit chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e When implementing dual-redundant pairs, order an additional tracking module with identical technical specifications but without specific optional suffix accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Isolation Barriers:\u003c\/strong\u003e Do not connect Zener barriers directly to this hardware. Utilize an approved isolation barrier when deploying an intrinsically safe instrumented loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFalse Insertion Prevention:\u003c\/strong\u003e When deploying option \/PRP, utilize the specified matching field signaling cable variant equipped with the corresponding option \/SAI143 to ensure functional physical key alignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eISA Standard G3:\u003c\/strong\u003e Certified for installation within corrosive industrial environments meeting the G3 severity specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695387537771,"sku":"SAI143-S33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-sai143-s33-analog-input-module-0qm2q1jxoya_d243d919-79c4-446a-a853-432dc8aee39e.jpg?v=1766132816"},{"product_id":"yokogawa-spw481-13-s1-prosafe-rs-power-supply-module","title":"Yokogawa SPW481-13 S1 ProSafe-RS Power Supply Module","description":"\u003ch3 data-path-to-node=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003eYokogawa SPW481-13 S1\u003c\/b\u003e is a high-reliability power supply module designed specifically for the ProSafe-RS safety instrumented system (SIS). This module functions by converting a 100 to 120 V AC input supply into stable, regulated dual-redundant +5 V DC and +24 V DC outputs required to energize the safety control station CPU modules, I\/O modules, and system infrastructure. Engineered for continuous industrial operation, the \u003cb data-path-to-node=\"2\" data-index-in-node=\"430\"\u003eYokogawa SPW481-13 S1\u003c\/b\u003e supports hot-swapping and features integrated protective circuitry to ensure high system availability, safety loop continuity, and resilient fault containment across demanding automation environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eDual-Redundant Support\u003c\/b\u003e: Accommodates dual-redundant insulated output operations to maximize safety system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHot-Swappable Design\u003c\/b\u003e: Enables maintenance personnel to replace modules without disconnecting system power or causing control interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eComprehensive Fault Containment\u003c\/b\u003e: Equipped with internal monitoring and protective circuitry against unsafe power supply exceptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eIndustrial Construction\u003c\/b\u003e: Ruggedly designed to fit seamlessly into specialized ProSafe-RS control racks for prolonged operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003eHigh-integrity emergency shutdown (ESD) systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003eFire and gas (F\u0026amp;G) system power architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003eBurner management systems (BMS) in power generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003eCritical interlock networks within petrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003eDistributed safety control system node power management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003e\u003cb data-path-to-node=\"8,1,0,0\" data-index-in-node=\"0\"\u003eSPW481\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,2,0\"\u003ePower Supply Module (100-120 V AC Input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003e-1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,2,0\"\u003e100-120 V AC input, +5 V DC and +24 V DC output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,2,0\"\u003eWith no explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eStyle Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,2,0\"\u003eStyle 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003e\u003cb data-path-to-node=\"10,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eSPW481-13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003e\u003cb data-path-to-node=\"10,3,0,0\" data-index-in-node=\"0\"\u003eStyle\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003eS1 (Style 1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003e\u003cb data-path-to-node=\"10,4,0,0\" data-index-in-node=\"0\"\u003eProduct Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003e\u003cb data-path-to-node=\"10,5,0,0\" data-index-in-node=\"0\"\u003eSystem Platform\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003eProSafe-RS Safety Instrumented System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003e\u003cb data-path-to-node=\"10,6,0,0\" data-index-in-node=\"0\"\u003eInput Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e100 to 120 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003e\u003cb data-path-to-node=\"10,7,0,0\" data-index-in-node=\"0\"\u003eInput Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003e\u003cb data-path-to-node=\"10,8,0,0\" data-index-in-node=\"0\"\u003eOutput Voltages\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e+5 V DC and +24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003e\u003cb data-path-to-node=\"10,9,0,0\" data-index-in-node=\"0\"\u003eOutput Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e2.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003e\u003cb data-path-to-node=\"10,10,0,0\" data-index-in-node=\"0\"\u003eProtection Functions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003eShort circuit, overload, overvoltage, undervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003e\u003cb data-path-to-node=\"10,11,0,0\" data-index-in-node=\"0\"\u003eRedundancy Support\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003eDual-redundant insulated output operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003e\u003cb data-path-to-node=\"10,12,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003e5.1 cm x 20.3 cm x 14.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,0,0\"\u003e\u003cb data-path-to-node=\"10,13,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,1,0\"\u003e0.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eEnsure the primary 100-120 V AC power line matches the input terminal requirements before performing power-on diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003eSecure the module firmly into its designated slot within the ProSafe-RS safety control unit or safety node unit rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003eEnsure adequate ventilation and clearance space around the cabinet enclosure to maintain nominal operating temperature thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003eGround the protective conductor terminal or functional grounding terminal according to official plant standard wiring instructions to minimize EMI\/RFI issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695388914027,"sku":"SPW481-13 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-spw481-13-s1-power-supply-module-4x1ihkphdpp_102005fe-dfd0-4a20-9ca6-04034545dc40.jpg?v=1766132940"},{"product_id":"yokogawa-sdv144-s13-digital-input-module-prosafe-rs","title":"Yokogawa SDV144-S13 Digital Input Module ProSafe-RS","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-1088\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eSDV144-S13 (SDV144-S13)\u003c\/strong\u003e\u003cspan class=\"citation-1088 citation-end-1088\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability, 16-channel digital input module engineered for the Yokogawa ProSafe-RS Safety Instrumented System (SIS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAs a crucial component in functional safety architectures, it is designed to monitor field device statuses—such as pressure switches, emergency stop buttons, and valve limit switches—in environments that require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 (Safety Integrity Level 3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompliance. The \"S13\" suffix specifies the hardware style and revision, featuring a standard configuration without the conformal coating found on \"C\" variants, yet maintaining the same high-speed diagnostics and galvanic isolation required to protect the safety controller from field-side electrical surges. In the lifecycle of an LNG terminal or refinery, the SDV144-S13 ensures that safety-critical data is processed with deterministic precision to prevent catastrophic failures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module operates within the FIO (Field network I\/O) node unit, utilizing a dual-microprocessor architecture to perform continuous self-tests on its internal circuitry. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLine Monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctionality, which allows the system to detect field wiring issues like open circuits or short circuits when used in conjunction with a resistor end-of-line (EOL) network. Each of the 16 channels is isolated from the internal system bus, providing a high degree of noise immunity and ensuring that a failure in one field loop does not propagate to the rest of the safety station.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSDV144-S13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSafe-RS \/ Centum VP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 mA (Typ. at 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eON Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOFF Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.0 x 4.0 x 13.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the S13 and S33 revisions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S13 is an earlier hardware style code compared to the S33. While they are functionally similar, you must verify the \"Style\" compatibility in your Yokogawa Builder software. Often, a newer S33 can replace an S13, but the reverse may require a firmware downgrade or project reconfiguration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support \"Hot Swap\" replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the SDV144-S13 supports online module replacement (Hot Swap). When the system is running, you can pull the faulty module and insert a new one; the Safety Control Station (SCS) will automatically download the configuration parameters to the new unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I clear a \"Line Fault\" error on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA Line Fault usually indicates a break or short in the field wiring. Check the 1 kOhm series and 10 kOhm parallel resistors at the field device. If the resistors are intact, inspect the terminal block connections for loose wires or corrosion.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEOL Resistor Placement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor safety loops requiring line monitoring, the resistors must be placed as close to the field contact as possible (e.g., inside the switch junction box). Placing them in the Marshalling Cabinet defeats the purpose of line monitoring, as it leaves the long field cable run unmonitored.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf you are using the SDV144-S13 in a redundant configuration (Dual-Redundant), ensure that the input signals are split correctly via a terminal board specifically designed for redundancy. Both modules must see the same input voltage simultaneously to avoid \"Input Mismatch\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure SIL3 reliability in high-EMI environments, the field cable shields should be grounded at the Marshalling Cabinet side only. Avoid \"Double Grounding\" which creates ground loops that can cause intermittent signal flickering on the 24 VDC digital inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695393534315,"sku":"SDV144-S13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-sdv144-s13-digital-input-module-tms0rnuof0x_4d0b1dec-1a3d-468a-98a2-840f40102841.jpg?v=1766133170"},{"product_id":"yokogawa-sdv144-s33-centum-vp-digital-input-module","title":"Yokogawa SDV144-S33 Centum VP Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSDV144-S33 (SDV144-S33)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Module designed for the Yokogawa Centum VP integrated production control system and the ProSafe-RS safety instrumented system (SIS).\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1082 citation-end-1082\"\u003eFeaturing 16 channels of isolated inputs, this module is a critical component for monitoring field switch statuses, valve positions, and emergency stop signals in high-integrity industries such as LNG terminals, petrochemical plants, and offshore oil platforms.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe \"S33\" suffix indicates a specific hardware revision and coating specification, ensuring the module meets the rigorous\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 (Safety Integrity Level 3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements. Its primary value lies in its ultra-reliable diagnostic capabilities, ensuring that the control system can distinguish between a normal process state and a field wiring fault, thereby preventing nuisance trips and maximizing plant uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-1081 citation-end-1081\"\u003eThe SDV144-S33 architecture is built around hardware redundancy and comprehensive self-diagnostics.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1080 citation-end-1080\"\u003eEach of the 16 channels is galvanically isolated to prevent electrical noise from the field from propagating to the system bus.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"Line Monitoring,\" which allows the system to detect open circuits or short circuits in the field wiring when used with external end-of-line (EOL) resistors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1079 citation-end-1079\"\u003eThis module is typically installed in an FIO (Field network I\/O) node unit and communicates via the ESB or ER bus, providing high-speed status updates to the Safety Control Station (SCS).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSDV144-S33\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCentum VP \/ ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (16-Channel, Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Integrity Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 mA (at 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.0 x 4.0 x 13.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFIO Node Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"S\" and \"33\" in the suffix signify?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S\" generally denotes a standard type with specific hardware features for safety systems, while \"33\" refers to the style code or revision. In Yokogawa's ecosystem, style codes are vital for ensuring compatibility with existing backplanes and software versions (Revision 3.3).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SDV144-S33 be used in a non-safety (DCS) application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it is primarily a ProSafe-RS (SIS) module, Yokogawa hardware is often cross-compatible within the FIO architecture. However, using a SIL3-rated module for standard DCS functions is generally not cost-effective unless standardized spares are required across the facility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support pulse counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SDV144 is optimized for state detection (On\/Off). For high-speed pulse counting or frequency measurement, Yokogawa offers dedicated pulse input modules (like the SET401) with specialized high-speed processing circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Monitoring Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf using the SDV144-S33 for safety-critical loops, ensure that the \"Line Monitoring\" function is enabled in the software. This requires the installation of a 10 kOhm parallel resistor and a 1 kOhm series resistor at the field device. Without these, the module cannot detect a wire break, which may compromise the SIL3 rating of the loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports \"Online Replacement.\" When replacing a faulty unit, ensure the new module's style code (S33) matches the one defined in the system project. Inserting a different style code may cause a configuration mismatch fault in the Safety Control Station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality ferruled connections for the pressure-clamp terminals. Given the 16-channel density, ensure that the common (negative) returns are properly balanced to avoid voltage drops that could lead to false \"Off\" states in long-distance cable runs (exceeding 200 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695394255211,"sku":"SDV144-S33","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-sdv144-s33-digital-input-module-lcwrqzjvfmk_7fc665bc-c975-497c-b2e0-4910e590d988.jpg?v=1766133213"},{"product_id":"yokogawa-snt501-13-prosafe-rs-optical-esb-bus-repeater-module","title":"Yokogawa SNT501-13 ProSafe-RS Optical ESB Bus Repeater Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNT501-13 (SNT501-13)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Optical ESB Bus Repeater Slave Module engineered for the ProSafe-RS safety instrumented system (SIS). Widely deployed in high-consequence process industries such as oil refining, petrochemical processing, and power generation, this module extends critical safety communication networks over long physical distances. It receives optical signals transmitted from an SNT401 master module or N-ESB bus module via fiber-optic cabling and converts them back to electrical signals. These signals are then routed via an ESB bus cable to the SSB401 ESB Bus Interface Module residing on the SNB10D safety node unit. By isolating the communication path through fiber optics, this module prevents electromagnetic interference (EMI) and ground-loop propagation across remote processing areas, ensuring continuous system uptime and robust machinery protection.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model and suffix code structure of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNT501-13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edictates its environmental protection rating, explosive atmosphere certification, and maintenance designation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSNT501\u003c\/strong\u003e: Base designator for the Optical ESB Bus Repeater Slave Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-1\u003c\/strong\u003e: Denotes a hardware build with no explosion protection, suitable for non-hazardous control room environments or installations utilizing external containment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3\u003c\/strong\u003e: Designates compliance with the ISA Standard G3 conformal coating specification for highly corrosive environments. This option also expands the certified operating temperature window to a wider range of -20 to 70 deg C, classified strictly for system maintenance and legacy support purposes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Metric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSNT501-13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eESB Bus optical transport function (Slave side)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Topology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStar type or Chain type network architectures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCascading Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum of 2 connecting stages\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransmission Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 5 km (total two stages); Max 10 km on Vnet\/IP R1.03 or later\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 70 deg C (-4 to 158 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 chemical resistance coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is it critical that the suffix codes of the bus 1 and bus 2 modules match exactly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For redundant safety configurations, both the primary (bus 1) and secondary (bus 2) repeater modules must share identical electrical, thermal, and signal-propagation characteristics. Mismatching suffix codes (such as pairing a standard module with a G3-coated, wide-temperature -13 module) can introduce minor timing offsets, compromising the synchronization of the ProSafe-RS safety bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SNT501-13 module be paired with any master-side optical repeater?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. To maintain proper optical link budgets and communication integrity, the master side and slave side must be paired systematically. The SNT501-13 (SNT501-dash-13) slave module must be paired specifically with the corresponding SNT401-13 master module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the ISA Standard G3 coating on this specific module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The G3 rating indicates that the module's printed circuit board (PCB) has a specialized conformal coating. This provides robust protection against chemical attack from corrosive gases (such as hydrogen sulfide, sulfur dioxide, and chlorine) commonly present in oil refineries, wastewater facilities, and paper mills.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnsuring Fiber Connection Cleanliness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore inserting the fiber-optic connectors into the SNT501-13, clean the cable end-faces using a dedicated fiber-optic reel cleaner or lint-free wipes saturated with industrial-grade isopropyl alcohol. Microscopic dust particles trapped in the optical transceiver interface can cause severe signal attenuation, leading to high bit-error rates on the ESB bus or communication timeouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eObserving Minimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring cabinet routing, ensure the fiber-optic cables do not exceed their specified minimum bend radius (typically 30 mm for standard multi-mode fiber). Sharp bends can cause micro-bends in the glass core, resulting in permanent optical power loss that reduces the maximum transmission distance below the rated 5 km or 10 km limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Path Physical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen implementing a redundant star or chain topology, route the fiber-optic cables for Bus 1 and Bus 2 through completely separate physical conduits and cable trays. This prevents a single physical impact, fire, or localized cabinet accident from severing both communication lines simultaneously, preserving safety system operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695401857387,"sku":"SNT501-13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-snt501-13-optical-esb-bus-repeatermodule-lvcejdnyuvi_850e14da-4a42-45b1-89dd-c62c63aea84a.jpg?v=1766133774"}],"url":"https:\/\/www.plcprotech.com\/th\/collections\/yokogawa-prosafe-rs.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}