{"product_id":"abb-ei-813f-3bdh000017r1-ac-800f-ethernet-module","title":"ABB EI 813F 3BDH000017R1 AC 800F Ethernet Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3BDH000032R1 FI 830F\u003c\/strong\u003e is a dedicated communication interface module developed for the ABB Freelance control system platform. This hardware component functions as a PROFIBUS-DP master, enabling cyclic and non-cyclic data transmission between the central controller and decentralized peripheral field devices. Engineered for direct backplane integration, the module is designed to be used together with the PM 802F or PM 803F processor units within the AC 800F hardware family. The \u003cstrong\u003e3BDH000032R1 FI 830F\u003c\/strong\u003e ensures deterministic signal exchange and comprehensive line diagnostics, making it an essential linkage for managing complex instrument topologies in process industries.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides a native PROFIBUS-DP master interface for the Freelance AC 800F controller system.\u003c\/li\u003e\n\u003cli\u003eEngineered to operate in direct synchronization with PM 802F or PM 803F processor units.\u003c\/li\u003e\n\u003cli\u003eEstablishes high-speed, reliable transmission links with remote I\/O blocks and smart instrumentation.\u003c\/li\u003e\n\u003cli\u003eFeatures a slim, space-saving layout to optimize physical space inside marshalling subracks.\u003c\/li\u003e\n\u003cli\u003eDesigned with completely battery-free hardware architecture to streamline long-term lifecycle maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFieldbus segment aggregation and master control loops within ABB Freelance DCS networks.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O communication bridging for AC 800F processing stations.\u003c\/li\u003e\n\u003cli\u003eHigh-speed instrumentation integration in water treatment, chemical, and utility industries.\u003c\/li\u003e\n\u003cli\u003eSmart actuator and motor control center (MCC) telemetry configuration networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eQty\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3BDH000032R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFI 830F Fieldbus Module PROFIBUS-DP\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BDH000032R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFI 830F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMalta (MT), Germany (DE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e853890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Expansion Slots\u003c\/strong\u003e: Mount the communication module directly into the corresponding expansion slot of the AC 800F controller assembly, ensuring it mates securely with the processing unit backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Interfacing\u003c\/strong\u003e: Ensure that the base controller rack is populated with a PM 802F or PM 803F processor module to enable fieldbus subsystem detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Termination\u003c\/strong\u003e: Always activate or install physical RS485 line terminators at both extreme physical ends of the PROFIBUS-DP segment to prevent data packet reflection and transmission anomalies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep standard PROFIBUS communication networks well isolated from high-current AC electrical cables to reduce inductive noise or electro-magnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Status\u003c\/strong\u003e: Not RoHS Compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Category\u003c\/strong\u003e: Classified under Category 5: Small Equipment (with no external dimensions exceeding 50 cm).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955621227,"sku":"3BDH000017R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bdh000017r1-yi2ri5mnu0k_49c344a9-835e-4292-aacd-f2e2d0b6903a.jpg?v=1766478064","url":"https:\/\/www.plcprotech.com\/th\/products\/abb-ei-813f-3bdh000017r1-ac-800f-ethernet-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}