{"product_id":"bently-nevada-330730-080-13-05-3300-xl-11mm-extension-cable","title":"Bently Nevada 330730-080-13-05 3300 XL 11mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330730-080-13-05\u003c\/strong\u003e is an 8.0-meter \u003cstrong\u003e3300 XL 11 mm Extension Cable\u003c\/strong\u003e designed for high-performance vibration and proximity monitoring within the \u003cstrong\u003e3300 XL 11 mm\u003c\/strong\u003e product line. This cable is configured as an armored FluidLoc cable with an integrated connector protector, providing maximum mechanical protection and preventing oil or other process liquids from migrating through the cable interior. Equipped with gold-plated brass ClickLoc connectors, it delivers a secure physical lock that resists structural loosening under severe industrial vibrations. The cable is optimized for machinery protection applications requiring an extended linear range, such as axial thrust position measurements, ramp differential expansion on steam turbines, rod drop monitoring on reciprocating compressors, and speed measurements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart of the \u003cstrong\u003e3300 XL 11 mm Extension Cable\u003c\/strong\u003e family engineered to upgrade and replace legacy 7200-series 11 mm and 14 mm transducer components.\u003c\/li\u003e\n\u003cli\u003eConstructed with 75 ohm triaxial, fluoroethylene propylene (FEP) insulated cable material.\u003c\/li\u003e\n\u003cli\u003eFeatures an armored FluidLoc design to block internal liquid leakage and withstand severe mechanical wear.\u003c\/li\u003e\n\u003cli\u003eFactory-installed connector protector provides robust environmental sealing against moisture and high humidity.\u003c\/li\u003e\n\u003cli\u003eGold-plated brass ClickLoc connectors guarantee stable electrical contact and click-locking security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial (thrust) position measurements.\u003c\/li\u003e\n\u003cli\u003eRamp differential expansion measurements on steam turbines.\u003c\/li\u003e\n\u003cli\u003eRod position or rod drop measurements on reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and phase reference (Keyphasor) signal measurements.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and position monitoring on fluid film bearing machines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 330730-080-13-05 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length Option (AAA):\u003c\/strong\u003e 080 (8.0 meters \/ 26.2 feet) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector and Cable Option (BB):\u003c\/strong\u003e 13 (Armored FluidLoc cable with connector protector) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option (CC):\u003c\/strong\u003e 05 (Multiple Approvals) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene (FEP) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 SST with FEP outer jacket \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance (Center Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 +\/- 0.2 ohms (RCORE) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance (Coaxial Conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 +\/- 0.5 ohms (RJACKET) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinger tight \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.565 N-m (5 in-lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored Extension Cable Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 g\/m (1.5 oz\/ft) typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \u0026amp; Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 Fahrenheit to +351 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the combined length of the extension cable and the matched proximity probe precisely matches the total system length parameters designated by the Proximitor Sensor.\u003c\/li\u003e\n\u003cli\u003eMaintain cable layouts within the minimum allowable bend radius constraint of 25.4 mm (1.0 in) to protect the internal triaxial conductors and outer armor.\u003c\/li\u003e\n\u003cli\u003eTighten connectors to a finger-tight condition, ensuring they do not exceed the absolute limit of 0.565 N-m (5 in-lb).\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated connector protector to keep moisture, dust, and process contamination away from the signal connection interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e (Standards: EN 61000-6-2, EN 61000-6-4) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive 2011\/65\/EU\u003c\/strong\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS\u003c\/strong\u003e (EFUP designation of 15 years per SJ\/T 11364-2024) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals\u003c\/strong\u003e (2019 Rules for Conditions of Classification) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: SIL 2 (HFT=0), SIL 3 (HFT=1) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Certifications (ATEX\/IECEx\/cNRTLus)\u003c\/strong\u003e: Ex ia IIC T5...T1 Ga, Ex ia IIIC T90C...T280C Dc, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325757291,"sku":"330730-080-13-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-00-wyzpu1y5o5d_b59f7634-1c85-4e60-b4d4-529eb2717eb0.jpg?v=1765521307","url":"https:\/\/www.plcprotech.com\/th\/products\/bently-nevada-330730-080-13-05-3300-xl-11mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}