{"product_id":"bently-nevada-330880-16-35-036-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-16-35-036-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330880-16-35-036-00-02\u003c\/strong\u003e is a self-contained proximity transducer system designed for continuous vibration and position monitoring in harsh industrial environments. This specialized \u003cstrong\u003ePROXPAC XL proximity transducer assembly\u003c\/strong\u003e integrates the functionalities of a conventional proximity probe housing and a 3300 XL Proximitor sensor directly into the housing cover. This integrated approach eliminates the need for an external extension cable and separate sensor housing, allowing field wiring to connect directly from the monitoring system to the assembly. Encased in a glass-reinforced Polyphenylene Sulfide (PPS) thermoplastic housing with conductive fibers, the system provides excellent resistance against mechanical impacts and dissipates electrostatic charges effectively. The system interfaces with a standard 3300 XL 8 mm proximity probe and provides a reliable analog voltage output directly proportional to the distance between the probe tip and the target surface. It is widely used in Machinery Protection Systems (such as Bently Nevada 3500 Series) for monitoring critical machinery parameters like radial vibration, axial position, and shaft alignment across demanding industries including oil and gas, power generation, and chemical processing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Design:\u003c\/strong\u003e Combines standard proximity probe housing benefits with an on-board 3300 XL Proximitor sensor inside the cover, minimizing cable runs and external footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Material Construction:\u003c\/strong\u003e Molded Polyphenylene Sulfide (PPS) housing with glass and conductive fibers offers higher strength and replaces traditional steel\/aluminum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSevere Environment Protection:\u003c\/strong\u003e Rated for Type 4X and IP66 environments to secure internal electronics from moisture, dust, and corrosive ambient elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Dissipation:\u003c\/strong\u003e Conductive fibers blended into the thermoplastic housing body effectively dissipate accumulated electrostatic charges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Field Wiring:\u003c\/strong\u003e Field connections connect directly between monitors and the PROXPAC XL assembly, removing additional intermediate terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Sensor Adjustment:\u003c\/strong\u003e Retains full compatibility with structural advantages of 31000\/32000 housings for simple external probe gap positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and Gas Turbine Shaft Vibration and Thrust Position Monitoring\u003c\/li\u003e\n\u003cli\u003eCentrifugal Compressor Axial Displacement and Radial Orbit Analysis\u003c\/li\u003e\n\u003cli\u003eIndustrial Pump and Gearbox Bearings Condition Monitoring\u003c\/li\u003e\n\u003cli\u003eHydroelectric Generator Shaft Real-time Alignment Controls\u003c\/li\u003e\n\u003cli\u003eCritical Rotating Machinery Protection Systems (TSI\/Tanks\/Piping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe component breakdown below corresponds to the explicit technical specifications verified for the ordering option code \u003cstrong\u003e330880-16-35-036-00-02\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330880\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer, English \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 in (89 mm) Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e036\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 in (91 mm) Probe Penetration Option (C Dimension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT Mounting Thread Option (Required if ordering Standoff Adapter Option) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance (RPROBE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter conductor to outer conductor: 7.59 +\/- 0.50 Ohm (for 1.0 m length) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG); 3-conductor shielded triax cable recommended; 305 metres (1,000 feet) max to monitor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils); begins at approx. 0.25 mm (10 mils) up to 2.3 mm (90 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error (0 degC to +45 degC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin Country\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case \/ Sleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.5 N-m (260 in-lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.3 N-m (350 in-lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44 kg (3.2 lbm) typical with 0.3 metre (12 in) sleeve length \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Dimensions (Depth)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92.7 mm (3.65 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing and Sensor Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Mechanical Ingress\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X and IP66 rating verified by BASEEFA report T07\/0709 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Impact Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertified by BASEEFA to withstand two 4 Joule impacts at -39 degC and +115 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSleeve Structural Support:\u003c\/strong\u003e If the combined total of Dimension \"B\" (Standoff Adapter) and Dimension \"C\" (Probe Penetration) exceeds 305 mm (12.0 in), you must add an extra sleeve support mechanism near the probe body to stiffen the overall assembly and prevent resonance issues under operational frequencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Positioning:\u003c\/strong\u003e Ensure initial mechanical gapping is targeted at the center of the sensor's linear range—ideally 1.27 mm (50 mils) from the shaft target. The integrated threaded sleeve configuration allows manual position trimming of +\/- 12.7 mm (0.5 in) from the baseline target setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Routing \u0026amp; Moisture Control:\u003c\/strong\u003e Although the PPS enclosure seals tightly against external spray, users must deploy standard sealing dopes or physical isolation traps on conduit entry points to block environmental moisture from traveling down the conduit pipeline directly into the terminal block area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Mitigation:\u003c\/strong\u003e Maintain a baseline structural spacing between nearby transducer tips of at least 40 mm (1.6 in) during axial configurations, or 38 mm (1.5 in) for radial vibration frameworks to keep electromagnetic cross-talk interference below 50 mV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Standards:\u003c\/strong\u003e 2019 Rules for Conditions of Classification (Part 1, Offshore Units and Structures).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668291580267,"sku":"330880-16-35-036-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330880-16-35-036-00-02-x3ohtfnfmfa_dbc884bc-2651-4b2e-b01b-21fb5e7a2bb3.jpg?v=1765520356","url":"https:\/\/www.plcprotech.com\/th\/products\/bently-nevada-330880-16-35-036-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}