{"product_id":"siemens-6gk5307-3bl00-2aa3-simatic-scalance-x307-3-managed-plus-ie-switch","title":"Siemens 6GK5307-3BL00-2AA3 SIMATIC SCALANCE X307-3 Managed Plus IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eSiemens 6GK5307-3BL00-2AA3\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X307-3\u003c\/strong\u003e, managed plus Industrial Ethernet (IE) switch designed for robust industrial communication networks. This module features a versatile port configuration, including 3x 1000 Mbit\/s Multi-Mode (MM) SC ports and 7x 10\/100 Mbit\/s RJ45 ports, enabling flexible connectivity options. It incorporates LED diagnostics for status monitoring and an error signaling contact with a select\/set pushbutton for fault management. The \u003cstrong\u003e6GK5307-3BL00-2AA3\u003c\/strong\u003e functions as a PROFINET IO device and includes comprehensive network management capabilities, an integrated redundancy manager, and office features such as RSTP, VLAN, and IGMP to ensure reliable and efficient data flow. A C-plug is included in the scope of supply for convenient setup.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3x 1000 Mbit\/s Multi-Mode (MM) SC ports\u003c\/li\u003e\n\u003cli\u003e7x 10\/100 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003eLED diagnostics for operational status\u003c\/li\u003e\n\u003cli\u003eError signaling contact with select\/set pushbutton\u003c\/li\u003e\n\u003cli\u003ePROFINET IO device functionality\u003c\/li\u003e\n\u003cli\u003eIntegrated network management\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy manager for high availability\u003c\/li\u003e\n\u003cli\u003eSupports office features including RSTP, VLAN, and IGMP\u003c\/li\u003e\n\u003cli\u003eC-plug included in scope of supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens 6GK5307-3BL00-2AA3 SCALANCE X307-3 Managed Plus IE Switch is suitable for a wide range of industrial applications requiring reliable and managed network communication, including:\n\u003cul\u003e\n\u003cli\u003eIndustrial automation systems and control networks\u003c\/li\u003e\n\u003cli\u003ePROFINET-based architectures\u003c\/li\u003e\n\u003cli\u003ePlant-wide data communication\u003c\/li\u003e\n\u003cli\u003eIntegration of office and industrial networks\u003c\/li\u003e\n\u003cli\u003eApplications requiring network redundancy and fault tolerance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged Plus IE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE X307-3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5307-3BL00-2AA3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePort Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3x 1000 Mbit\/s MM SC, 7x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLED diagnostics, Error signaling contact with select\/set pushbutton\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIndustrial Protocol Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManagement Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork management, Integrated redundancy manager\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOffice Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRSTP, VLAN, IGMP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eC-plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.00 x 12.30 x 12.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the switch securely on a DIN rail or panel in a suitable industrial enclosure, ensuring adequate ventilation and clearance for cabling.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply according to the module's specifications. Ensure proper polarity and grounding to prevent electrical damage and ensure safe operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-Plug Installation:\u003c\/strong\u003e Insert the provided C-plug into its designated slot on the switch.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect the 10\/100 Mbit\/s RJ45 ports using standard Ethernet cables. For the 1000 Mbit\/s MM SC ports, use appropriate fiber optic cables. Ensure cables are properly routed and secured to prevent strain and interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a reliable protective earth (PE) connection for the device to minimize electromagnetic interference and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Once powered, configure the switch parameters (e.g., VLANs, redundancy settings, PROFINET IO device settings) via the network management interface as required by the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Verify all connections and configurations by performing functional tests to ensure proper network operation and communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716760695147,"sku":"6GK5307-3BL00-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5307-3bl00-2aa3-xq4t0u2owdo_cb374092-ec09-453d-b0ab-e2776578fbdf.jpg?v=1767088824","url":"https:\/\/www.plcprotech.com\/th\/products\/siemens-6gk5307-3bl00-2aa3-simatic-scalance-x307-3-managed-plus-ie-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}