{"product_id":"5069-l306er-allen-bradley-compact-guardlogix-5380-safety-controller","title":"5069-L306ER Allen-Bradley Compact GuardLogix 5380 Safety Controller","description":"\u003ch3\u003eCritical Product Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER (5069L306ER)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety controller engineered to provide integrated motion and safety control within a single hardware platform. This unit is specifically designed for complex industrial applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe (Category 4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety ratings. By utilizing a dual-processor architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes safety logic and standard logic simultaneously, significantly reducing the hardware footprint and simplifying system integration. Ideal for high-speed manufacturing, automotive assembly lines, and heavy machinery, this controller optimizes system reaction times and minimizes unplanned downtime through advanced diagnostics and high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity. It provides a scalable solution for engineers looking to balance rigorous safety standards with maximum operational efficiency.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Configuration and Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol engine to deliver high-speed processing and increased throughput. This controller is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandard user memory and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ededicated safety memory. The dual-port design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 EtherNet\/IP nodes\u003c\/strong\u003e, allowing for flexible network topologies including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDevice Level Ring (DLR)\u003c\/strong\u003e, Linear, and Star configurations.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5380 series\u003c\/strong\u003e, it operates using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000 Logix Designer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware (Version 31 or later). The hardware design isolates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule (MOD) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(logic side) from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(field side), preventing electrical noise from impacting the central processing unit and ensuring stable execution of safety instructions in electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 3 \/ PLe \/ Cat. 4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e16 Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e8 Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0 to 60 deg C\u003c\/strong\u003e (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-40 to 85 deg C\u003c\/strong\u003e (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e18 to 32 VDC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e143.97 x 98.10 x 136.81 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately \u003cstrong\u003e0.77 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 5069-L306ER achieve SIL 3 safety without an external safety partner?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a built-in 1oo2 (one out of two) processor architecture. The internal safety task is executed in a redundant manner, and the controller performs continuous self-diagnostics to ensure safety integrity. This allows the unit to meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements in a single, compact module without the need for a separate safety partner module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this controller be used with standard 5069 Compact I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard and safety-rated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. However, to maintain the safety integrity of a specific safety loop, you must utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety I\/O modules for the safety-related inputs and outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the SD card slot on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller includes a slot for an industrial-grade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSecure Digital (SD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard (1 GB standard). This is used for non-volatile storage of the user program, firmware, and safety configurations. It allows for fast \"device replacement\" without requiring a PC to reload the logic, which is critical for reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrecision Installation \u0026amp; Thermal Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Isolation Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare sourced from separate power supplies if your application requires isolation between logic and field-side devices. Use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSELV\/PELV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated power supply to comply with regulatory standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo mitigate electromagnetic interference (EMI), use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrounding and ensure all communication cables are shielded. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be mounted on a grounded, corrosion-resistant DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(2 inches) of clearance on all sides of the controller. This ensures adequate convection cooling and prevents thermal throttling when operating at the upper limit of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; Durability Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Motion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 axes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof integrated motion over EtherNet\/IP, allowing safety instructions (like Safe Torque Off) to be executed directly over the network, eliminating hard-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt with industrial-grade components, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high-vibration environments and features a conformal coating option for protection against chemical contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Cybersecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigitally signed firmware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand controller-based change detection, providing a robust layer of defense against unauthorized code injection or tampering in mission-critical infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084783870315,"sku":"5069-L306ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L306ER.png?v=1775998108","url":"https:\/\/www.plcprotech.com\/tr\/products\/5069-l306er-allen-bradley-compact-guardlogix-5380-safety-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}