{"product_id":"abb-exc58918539-nint-44-sp-kit-main-circuit-interface-board-kit","title":"ABB EXC58918539 NINT-44 SP Kiti Ana Devre Arayüz Kartı Kiti","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB EXC58918539\u003c\/strong\u003e is an official exchange \u003cstrong\u003eNINT-44 SP KIT\u003c\/strong\u003e Main Circuit Interface (MCI) board kit. This component serves as a core electronic interface board inside high-power industrial AC frequency converters and inverter systems. It acts as the signal management and control interface link between the central processor framework and the main circuit power semiconductor configuration. The board manages high-speed gating commands and feeds real-time phase tracking metrics back to the main controller, safeguarding stable current distribution and synchronized operation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-Specified Exchange Part\u003c\/strong\u003e: Designated as a qualified replacement kit to efficiently restore power section functionality during scheduled drive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Control Interfacing\u003c\/strong\u003e: Handles critical main circuit gating lines, ensuring clear communication between processing logic and the power bridge components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Legacy System Support\u003c\/strong\u003e: Maintained under strict OEM quality standards to prolong the operational lifecycle of legacy motor drive networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Inverter Bridge Coordination\u003c\/strong\u003e: Manages pulse distribution and fault telemetry directly on the main switching circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Variable Speed Drives\u003c\/strong\u003e: Deployed in low-voltage industrial converter cabinets to handle heavy motor load routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Component Overhauls\u003c\/strong\u003e: Used as a direct drop-in spare kit to upgrade or replace old legacy interface hardware revisions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXC58918539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNINT-44 SP KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAIN CIRC. INTERF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExchange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelated Product ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58918539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaced Product ID (OLD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXC58913022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinland (FI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mm x 110 mm x 35 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect all primary incoming voltage paths and execute formal lockout\/tagout safety practices before opening the drive framework.\u003c\/li\u003e\n\u003cli\u003ePrior to touching any interface terminals, verify that the internal DC link busbar capacitors have fully discharged using a certified voltage testing instrument.\u003c\/li\u003e\n\u003cli\u003eEnsure all structural grounding screws are tightly set against the metallic backplate to maintain solid electromagnetic immunity (EMI) control performance.\u003c\/li\u003e\n\u003cli\u003eAlign and route adjacent signal wiring harnesses clean of high-voltage phase busbars to avoid cross-coupling noise during drive operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668615262571,"sku":"NINT-44","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-nint44-nint-44-communication-card-avo434n2oop_28b64f67-ef35-45b7-8780-74ce4467f250.jpg?v=1765535641","url":"https:\/\/www.plcprotech.com\/tr\/products\/abb-exc58918539-nint-44-sp-kit-main-circuit-interface-board-kit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}