{"product_id":"abb-nkst11-15-symphony-harmony-infi-90-soe-di-and-time-synch-module-tu-cable","title":"ABB NKST11-15 Symphony Harmony INFI 90 SOE DI and Time Synch Module TU Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB NKST11-15\u003c\/strong\u003e is a prefabricated sequence of events (SOE) digital input and time synchronization termination unit (TU) cable designed for high-precision temporal tracking in process automation environments. This \u003cstrong\u003eSOE Time Synch Cable\u003c\/strong\u003e spans a length of 15 feet and is engineered specifically to connect the SET SOE digital input module to the NTST termination unit. Built with a halogen-free, non-PVC outer jacket, the \u003cstrong\u003eNKST11-15\u003c\/strong\u003e matches rigid environmental and safety standards by minimizing toxic smoke emissions during thermal events. It provides a dedicated communication interface to ensure microsecond-level time stamp synchronization across the Symphony Harmony INFI 90 control architecture.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrefabricated design equipped with reliable factory connectors to ensure plug-and-play field setup.\u003c\/li\u003e\n\u003cli\u003eFormulated with non-PVC, halogen-free insulation materials for specialized environmental safety requirements.\u003c\/li\u003e\n\u003cli\u003eFixed 15-foot physical cable configuration optimizing signal delivery parameters between target modules.\u003c\/li\u003e\n\u003cli\u003eDesigned exclusively to integrate the IMSET01 or equivalent SET digital input modules with the companion NTST unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSymphony Harmony INFI 90 Sequence of Events (SOE) recording structures.\u003c\/li\u003e\n\u003cli\u003ePrecision time synchronization links within Distributed Control Systems (DCS).\u003c\/li\u003e\n\u003cli\u003eHigh-security plant control rooms requiring low-smoke halogen-free infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNKST11-15 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNKST11-15 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrefabricated_Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e508 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e254 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.127 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot exceeding 1000 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444290 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e854442 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Plan paths properly to protect the 0.127 mm diameter cable assembly from sharp corners and sharp mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Allocation:\u003c\/strong\u003e Ensure the connection directly mapping from the SET module matches the dedicated pins on the NTST assembly without tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Integrity:\u003c\/strong\u003e Maintain standard cabinet operating boundaries as the cable material contains a halogen-free specialized matrix.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668624372075,"sku":"NKST11-15","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-nkst11-15-soe-time-synch-cable-xnnkmxy0lxs_72073413-5f1b-429e-9bc6-dab7fe329acb.jpg?v=1765535923","url":"https:\/\/www.plcprotech.com\/tr\/products\/abb-nkst11-15-symphony-harmony-infi-90-soe-di-and-time-synch-module-tu-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}