{"product_id":"abb-s111-k10-s111-series-screw-in-circuit-breaker","title":"ABB S111-K10 S111 Series Screw-in Circuit Breaker","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for seamless integration into legacy and specialized electrical distribution systems, the \u003cstrong\u003eABB S111-K10\u003c\/strong\u003e functions as a high-reliability screw-in miniature circuit breaker. Designed to directly replace traditional screw-in fuse links, this device features a standard E27 thread base, enabling quick retrofitting without requiring complete panel upgrades. The unit incorporates a thermal-magnetic tripping mechanism to deliver precise overcurrent and short-circuit protection, combining the convenience of a modern, resettable circuit breaker with the physical form factor of legacy fuse systems.\u003c\/p\u003e\n\n\u003cp\u003eBy utilizing the K-tripping characteristic, the \u003cstrong\u003eABB S111-K10\u003c\/strong\u003e is highly suited for safeguarding control circuits, auxiliary systems, and loads with moderate inrush currents. This device ensures minimized downtime through its immediate manual reset capability following a fault, eliminating the ongoing maintenance overhead and waste associated with disposable melt fuses.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect screw-in installation utilizing a standard E27 thread base for rapid retrofitting.\u003c\/li\u003e\n  \u003cli\u003eThermal-magnetic trip mechanism provides robust overcurrent and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003eResettable design eliminates the requirement for replacement fuse links after tripping events.\u003c\/li\u003e\n  \u003cli\u003eK-characteristic curve optimized for sensitive equipment and circuits with transient inrush currents.\u003c\/li\u003e\n  \u003cli\u003eClear mechanical status indication for straightforward operational diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eModernization of legacy residential and commercial distribution panels.\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in industrial control systems and auxiliary circuits.\u003c\/li\u003e\n  \u003cli\u003eMachinery control panels requiring compact, socket-mounted circuit protection.\u003c\/li\u003e\n  \u003cli\u003eFacility maintenance and retrofitting where panel space or configuration restricts DIN-rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eS111-K10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew-in-type Circuit Breaker\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Thread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eK-curve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.05 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePrior to installation, ensure the target electrical circuit is completely de-energized and locked out.\u003c\/li\u003e\n  \u003cli\u003eInspect the existing E27 socket for dirt, corrosion, or damage before inserting the circuit breaker.\u003c\/li\u003e\n  \u003cli\u003eThread the device into the socket manually, turning clockwise until firmly seated. Do not apply excessive torque to prevent cracking the socket casing.\u003c\/li\u003e\n  \u003cli\u003eVerify that the rated load of the branch circuit does not exceed the 10 A capacity of the device.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958144363,"sku":"S111-K10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s111-k10-xtanrjuk14v_1a3df4d9-a8d1-4395-bbcb-fa678a59c0bb.jpg?v=1766478144","url":"https:\/\/www.plcprotech.com\/tr\/products\/abb-s111-k10-s111-series-screw-in-circuit-breaker","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}