{"product_id":"abb-sb822-3bse018172r1-ac-800m-rechargeable-battery-unit","title":"ABB SB822 3BSE018172R1 AC 800M Rechargeable Battery Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ABB SB822 is an external rail-mounted backup energy component engineered to preserve volatile application logic and database memory inside AC 800M controller configurations during main line power blackouts. Operating as a dedicated \u003cstrong\u003erechargeable battery unit\u003c\/strong\u003e, this hardware delivers a regulated 3.6 VDC output profile, sustaining critical execution states and preventing data loss within distributed control system node processors.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eSB822\u003c\/strong\u003e assembly contains a specialized lithium-ion cell core complete with an integrated charging interface, a local 24 VDC connection block, and a dedicated TK821V020 system interface cable link. Cataloged under product ID \u003cstrong\u003e3BSE018172R1\u003c\/strong\u003e, this smart auxiliary backup source coordinates with System 800xA and Compact Product Suite power modules to manage memory hold-up sequences across manufacturing execution networks without risking logic degradation.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eLithium-Ion Core Technology\u003c\/strong\u003e: Features a long-life internal cell containing approximately 0.8 g of lithium metal equivalent to ensure high-density charge holding capacity.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Charging Management\u003c\/strong\u003e: Utilizes a dedicated 24 VDC power interface connection to regulate internal charge state parameters dynamically.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eComplete Interface Kit\u003c\/strong\u003e: Packaged together with the necessary TK821V020 data connection cable to enable rapid deployment at the controller node.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRail-Mounted Hardware\u003c\/strong\u003e: Built within a compact housing optimized for mounting directly on standard hardware tracks inside high-density automation panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eVolatile memory and parameter preservation for ABB AC 800M processors across System 800xA 4.1, 5.0, 5.1, and 6.0 control architectures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eExternal backup energy support for modular controller stations deployed in the Compact Product Suite platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSB822\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct ID \/ Order Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3BSE018172R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePower Supply \/ Battery Unit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Input Current (Iin)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.1 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Voltage (Uout)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3.6 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Output Current (Iout)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.05 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eLithium Content\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.8 g (0.03 oz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIncluded Interface Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTK821V020\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eChina (CN)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Type Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eOriginal \/ New\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.55 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.78 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e160 mm x 120 mm x 55 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe SB822 backup block is backwards-compatible across multiple generations of AC 800M controller setups including versions 4.1 through 6.0. It functions as a direct component swap for older restricted battery configurations. When substituting an old unit, always use the fresh TK821V020 link cable included in the kit to verify proper current delivery parameters and eliminate structural connection decay at the module bus interface.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDeploying this lithium-based backup device inside non-ventilated electrical bays where surrounding parameters exceed normal operating ranges will accelerate internal cell degradation. This can lead to reduced hold-up duration limits or immediate premature block capacity failure. System diagnostics status bits should be mapped in the automation engineering software tool to actively track battery health state flags and trigger maintenance warnings well before cell exhaustion occurs.\n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDuring initialization, verify that the 24 VDC auxiliary supply lines are connected correctly to the charging block input port. Without this active current path, the internal lithium cell will not charge and will drain down rapidly under static system states. Keep the interface loop cable separated from close tracking alongside high-amperage variable speed drive outputs to shield the internal tracking lines from electromagnetic distortion vectors.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0;\"\u003e\n    CRITICAL WARNING: DC AUXILIARY SUPPLY ISOLATION PROTOCOLS\n  \u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003e\n    Disconnect all active 24 VDC input feed paths powering the battery charging framework prior to component handling or interface cable installation. Working on live terminations poses localized short-circuit hazards that can corrupt adjacent processing circuits. Do not cut or alter the factory-assembled TK821V020 cable configuration.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003eSnap the SB822 chassis onto the standard DIN rail layout track directly adjacent to the target AC 800M controller assembly.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003eConnect the auxiliary 24 VDC line loop securely to the input power port to initialize the automated onboard charging circuit.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 0.15rem;\"\u003ePlug the TK821V020 link interface cable into the battery output port and land the opposite end into the matching controller backup terminal.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668583969131,"sku":"SB822 3BSE018172R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sb822-3bse018172r1-rechargeable-battery-unit-3n0uk2xulkt_5ed01d59-f513-4a53-b0b9-789254e790a2.jpg?v=1765532980","url":"https:\/\/www.plcprotech.com\/tr\/products\/abb-sb822-3bse018172r1-ac-800m-rechargeable-battery-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}