{"product_id":"allen-bradley-1771-p5-plc-5-power-supply-module","title":"Allen-Bradley 1771-P5 PLC-5 Power Supply Module","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003e1771-P5\u003c\/b\u003e is a chassis-mounted power supply module engineered within the 1771 product line to deliver regulated DC operating power directly to the backplane of standard industrial control chassis. This hardware component functions by accepting a nominal 24V DC input source and converting it to the clean, stabilized current levels required by processor units and adjacent input\/output instrumentation. The \u003cb data-path-to-node=\"1\" data-index-in-node=\"409\"\u003e1771-P5\u003c\/b\u003e configuration features built-in electrical protection mechanisms alongside clear structural diagnostics to ensure consistent power distribution in highly integrated automation environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003eSlotted chassis design that mounts directly into standard 1771 universal I\/O backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003eConfigured with a dedicated front-accessible green LED indicator verifying stable output status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003eBuilt-in dynamic overvoltage protection circuit preventing damage from incoming electrical transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003eIntegrated fuse architecture positioned internally to safeguard system backplane paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003ePower infrastructure for local and distributed 1771 chassis networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003eRegulated power sourcing for multi-slot logic processing arrays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003eIndustrial automation enclosures utilizing direct 24V DC input feeds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"7\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,0,0\"\u003e\u003cb data-path-to-node=\"7,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,1,1,0\"\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,0,0\"\u003e\u003cb data-path-to-node=\"7,2,0,0\" data-index-in-node=\"0\"\u003ePart Number \/ Model\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,2,1,0\"\u003e1771-P5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,0,0\"\u003e\u003cb data-path-to-node=\"7,3,0,0\" data-index-in-node=\"0\"\u003eProduct Line\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,3,1,0\"\u003e1771 Universal I\/O chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,0,0\"\u003e\u003cb data-path-to-node=\"7,4,0,0\" data-index-in-node=\"0\"\u003eModule Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,4,1,0\"\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,0,0\"\u003e\u003cb data-path-to-node=\"7,5,0,0\" data-index-in-node=\"0\"\u003eInput Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,5,1,0\"\u003e20.5 to 30.0V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,0,0\"\u003e\u003cb data-path-to-node=\"7,6,0,0\" data-index-in-node=\"0\"\u003eNominal Input Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,6,1,0\"\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,7,0,0\"\u003e\u003cb data-path-to-node=\"7,7,0,0\" data-index-in-node=\"0\"\u003eOutput Current Load\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,7,1,0\"\u003e8.0 Amps at 5.06V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,8,0,0\"\u003e\u003cb data-path-to-node=\"7,8,0,0\" data-index-in-node=\"0\"\u003eBackplane Current Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,8,1,0\"\u003e8.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,9,0,0\"\u003e\u003cb data-path-to-node=\"7,9,0,0\" data-index-in-node=\"0\"\u003eOvervoltage Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,9,1,0\"\u003eShuts down at 6.3V DC (nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,10,0,0\"\u003e\u003cb data-path-to-node=\"7,10,0,0\" data-index-in-node=\"0\"\u003eStatus Indicators\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,10,1,0\"\u003eGreen LED (Output Normal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,11,0,0\"\u003e\u003cb data-path-to-node=\"7,11,0,0\" data-index-in-node=\"0\"\u003eInternal Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"7,11,1,0\"\u003eFused Input Circuitry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eChassis Alignment:\u003c\/b\u003e Secure the power supply module into the leftmost assigned slot position of the 1771 I\/O chassis framework to guarantee correct backplane terminal configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eElectrical Termination:\u003c\/b\u003e Ensure all 24V DC wiring lines are isolated from active power sources before executing connections onto the front terminal strip assembly to eliminate current arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eOvercurrent Maintenance:\u003c\/b\u003e Always verify the replacement fuse specs completely align with factory specifications before restoring active power paths following an electrical overload trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eVentilation Matrix:\u003c\/b\u003e Ensure top and bottom chassis air paths remain unobstructed to handle baseline heat dispersal during full-load power output distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177298283,"sku":"1771-P5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1771-p5-24v-dc-power-supply-tukionbk2bl_c70d6f20-0638-4d2d-9f17-3c580a602ae9.jpg?v=1766114156","url":"https:\/\/www.plcprotech.com\/tr\/products\/allen-bradley-1771-p5-plc-5-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}