{"product_id":"beckhoff-c9900-f305-control-panel-interface-module","title":"Beckhoff C9900-F305 Kontrol Paneli Arayüz Modülü","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating high-performance visualization at extended physical distances, the \u003cstrong\u003eBeckhoff C9900-F305\u003c\/strong\u003e serves as an integrated DVI\/USB Extended interface option for industrial Control Panels. This interface module overcomes standard cable limitations by converting visual and input signals for transmission over long distances, allowing the operator interface to be positioned directly at the machine while the industrial PC remains protected within a centralized control cabinet. Utilizing robust physical connectors, the \u003cstrong\u003eC9900-F305\u003c\/strong\u003e ensures lag-free display updates and reliable peripheral data rates across the entire connection span.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Range Connectivity:\u003c\/strong\u003e Integrates DVI-E and USB-E 2.0 technologies to transmit video and USB signals up to 50 meters without signal degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed USB Transmission:\u003c\/strong\u003e Supports USB-E 2.0 protocol with physical layer transfer rates reaching up to 480 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Compatibility:\u003c\/strong\u003e DVI-E input remains completely compatible with standard PC DVI graphics outputs when used with appropriate transmitter units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Connection Interface:\u003c\/strong\u003e Features a standard USB 2.0 input for short-range configurations (up to 5 meters) directly to standard PC USB ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Hub:\u003c\/strong\u003e Provides downstream USB 2.0 ports at the panel for direct connection of human interface devices (HID) like keyboards, mice, or flash storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Lines:\u003c\/strong\u003e Separation of control PCs from harsh vibration zones on the factory floor while retaining local operator control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCleanroom Environments:\u003c\/strong\u003e Housing processing units outside controlled zones while routing thin, easily-sealed cables to the local display interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed HMI Topographies:\u003c\/strong\u003e Applications requiring multi-station visualization connected to a single, high-performance master industrial PC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 600px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eC9900-F305\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDVI-E (DVI Extended) and USB-E 2.0 (USB Extended)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaximum Distance (Extended)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 meters (using specialized DVI-E\/USB-E cabling)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaximum Distance (Standard)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 meters (direct standard USB 2.0 connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eData Transmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUp to 480 Mbit\/s (USB 2.0 speed limit via USB-E)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (supplied via Control Panel power link)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Rating (Front Side)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP65 (when correctly integrated into matching front housing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Rating (Rear Side)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e350 mm x 280 mm x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 600px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003ePort \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u003cstrong\u003eDVI Input\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDVI-D Female\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eReceives digital video signals from the PC transmitter unit.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u003cstrong\u003eRJ45 Port\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 Cat.6\/Cat.7 Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eExtends USB-E 2.0 communication up to 50 meters to host PC.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u003cstrong\u003eUSB 2.0 Input\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSB Type B\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDirect local connection to host PC (up to 5 meters maximum).\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u003cstrong\u003eUSB Downstream\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 x USB 2.0 Type A\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLocal peripheral connections (e.g., flash drive, keyboard, mouse).\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe C9900-F305 is specifically designed to match CP69xx built-in Control Panels or corresponding custom industrial monitors from Beckhoff. When retrofitting older setups, verify that the transmitter module on the industrial PC side (such as a CU8801 or matching PCIe transmitter card) supports the same USB-E 2.0 specifications to prevent baud-rate downshifting or device dropouts.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile standard RJ45 networking hardware is used for physical connectivity of the USB-E 2.0 signal, this path is \u003cstrong\u003enot\u003c\/strong\u003e an Ethernet network. Do not route the USB-E 2.0 RJ45 cable through network switches, hubs, or routers. Doing so will permanently damage the active routing hardware and prevent transmission. Always use a continuous, direct physical cable between the transmitter and the C9900-F305 module.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations approaching the 50-meter limit, use highly shielded Cat.7 STP (Shielded Twisted Pair) cables with metallic RJ45 plugs. Grounding the shield properly at the panel entry point is crucial to suppress EMI from adjacent VFD motor lines or high-voltage power paths within the cable tray.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.5rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: electrical isolation\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all 24 V DC power supplies before initiating panel installation or cable modification. Verify that the system's power supply is fully de-energized to prevent ESD or sudden voltage spikes across the active DVI-E and USB-E interface transceiver chips.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Secure the Control Panel housing into the machine cutout using the pull-out clamping levers. Ensure the IP65 rubber sealing ring on the front bezel lies flat against the clean mounting surface.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eDVI-E Video Routing:\u003c\/strong\u003e Connect the dedicated DVI-E cable to the DVI input port. Ensure the locking screws on the DVI connector are tightened hand-tight to secure electrical shield continuity.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eUSB-E Extension Hookup:\u003c\/strong\u003e Terminate your shielded Cat.7 line into the RJ45 port for long-distance USB extension. For setups within 5 meters, bypass this and use the USB Type B input connected directly to the IPC.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower Supply Initialization:\u003c\/strong\u003e Secure the 24 V DC supply leads to the terminal strip block. Confirm correct polarity (+24V, 0V, and Ground\/PE) before restoring supply power.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106508923243,"sku":"C9900-F305","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/c9900-f305-2brlkm03jpu.png?v=1776243661","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-c9900-f305-control-panel-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}