{"product_id":"beckhoff-cx2030-0135-cx2030-series-basic-cpu-module","title":"Beckhoff CX2030-0135 CX2030 Series Basic CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-performance industrial control architectures, the \u003cstrong\u003eBeckhoff CX2030-0135\u003c\/strong\u003e basic CPU module delivers dual-core processing power directly to the DIN rail. This unit integrates an Intel Core i7 1.5 GHz processor to execute complex automation tasks requiring rapid cycle times. By combining a robust fanless architecture with versatile connectivity options, the controller acts as the central execution engine for TwinCAT-based machinery control, data acquisition, and edge computing environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntel Core i7 Dual-Core Processor:\u003c\/strong\u003e 1.5 GHz clock speed provides deterministic execution of demanding PLC, NC, and MC tasks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Memory Bus:\u003c\/strong\u003e Equipped with 2 GB DDR3 RAM (expandable ex factory to 4 GB) to manage extensive project variables and operational runtimes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Volatile RAM:\u003c\/strong\u003e 128 kB of integrated NOVRAM ensures persistent data storage for critical machine states in the event of power disruption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic I\/O Interface:\u003c\/strong\u003e Built-in automatic recognition system seamlessly switches between EtherCAT Terminals (E-bus) and Bus Terminals (K-bus).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Expansion:\u003c\/strong\u003e Dedicated internal slot supports one optional interface module (such as PROFIBUS, CANopen, or RS232\/RS485\/RS422).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMulti-axis motion control systems and synchronized robotics pipelines.\u003c\/li\u003e\n  \u003cli\u003eProcess plants requiring deterministic, real-time control via TwinCAT runtime environments.\u003c\/li\u003e\n  \u003cli\u003eHigh-density data aggregation and manufacturing execution system (MES) integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCX2030-0135\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIntel Core i7 2610UE 1.5 GHz (2 Cores)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSystem Memory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 GB DDR3 (Factory expandable to 4 GB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eFlash Memory Storage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 GB or 40 GB CFast Card (dependent on OS configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePersistent Storage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e128 kB integrated NOVRAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eMax. Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e27 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003ePlatform Level\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTwinCAT 3 Platform Level: Mid Performance Plus (60)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eCooling System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePassive cooling (Optionally active via factory configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: -25 to +60 degC; padding: 0.5rem;\"\u003e-25 to +60 degC (no condensation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1165 g (approx. 2.57 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e144 mm x 99 mm x 91 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eEMC Conformity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eEN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSafety Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePort \/ Interface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003e2 x RJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10\/100\/1000 Mbit\/s Ethernet interfaces for independent network routing or EtherCAT operations\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003e1 x DVI-I Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDirect analog\/digital display output for human-machine interface (HMI) configurations\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003e4 x USB 2.0 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePeripheral device interfacing, local programming, or diagnostics access\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eOption Interface Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAccepts fieldbus configuration cards (e.g., CX2030-M310 PROFIBUS Master, CX2030-B510 CANopen Slave)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eI\/O Power Module Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDirect connection for CX2100-xxxx series power supplies to integrate K-bus or E-bus components\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis module operates on TwinCAT 3 Platform Level 60 (Mid Performance Plus). When replacing an older module with this CPU, ensure that your existing TwinCAT core licenses match Level 60 requirements to avoid system initialization faults. If replacing a Windows-based configuration, ensure that your application software matches the target OS platform installed on the CFast card (such as Windows Embedded Standard 7 or TwinCAT\/BSD).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn passively cooled setups, this module relies on uninhibited convective vertical airflow within the electrical enclosure. Do not stack wire ducts immediately above or below the module ventilation slots, as heat buildup can cause thermal throttling of the Core i7 processor. If the average ambient cabinet temperature regularly exceeds 45 degC, configure the unit with a factory-installed active cooling option to prevent degradation of system performance.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use high-quality, shielded Cat.6 network cabling for the RJ45 interfaces to shield the system from electromagnetic noise generated by nearby variable frequency drives (VFDs). Securely connect the functional ground rail via the integrated spring contacts on the rear DIN-rail mounting plate to ensure proper dissipation of high-frequency transients.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eBefore installing or performing service operations on this CPU module, disconnect all raw supply power from the system. Residual electrical charge must bleed completely to avoid electrostatic discharge (ESD) damage to sensitive motherboard traces or internal storage media.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eMount the CX2030-0135 onto a standard 35 mm DIN rail by applying gentle pressure until the lock mechanism clicks securely onto the metal rail.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eSlide the complementary power supply module (CX2100-xxxx) laterally into position on the right-hand side, establishing the physical and electrical interlink connection.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eInsert the pre-programmed CFast flash card into the designated card slot prior to powering up the system. Never insert or remove storage media while the module is energized.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eApply nominal 24 V DC power through the external power supply module. Observe the diagnostic LEDs: the power LED must illuminate solid green, followed by the TC status indicator confirming runtime execution.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106420777323,"sku":"CX2030-0135","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx2030-0135-kogcbpltndb.png?v=1776244179","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-cx2030-0135-cx2030-series-basic-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}