{"product_id":"beckhoff-cx2040-n031-0001-cx2000-series-basic-cpu-module","title":"BECKHOFF CX2040-N031-0001 CX2000 Series Basic CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCX2040-N031-0001\u003c\/strong\u003e is a high-performance \u003cstrong\u003eBasic CPU module\u003c\/strong\u003e designed for integration into the Beckhoff CX2000 series embedded PC systems. This unit serves as the central processing core, facilitating robust data handling and real-time control for complex industrial automation tasks. The module features an integrated \u003cstrong\u003eRS485 interface\u003c\/strong\u003e via a 9-pin D-sub socket, configured specifically for end-point communication. It supports echo functionality and includes internal termination to ensure signal integrity in serial communication networks. Engineered for demanding environments, this module supports scalable automation architectures and provides reliable processing power for modular control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentral processing unit for CX2000 series embedded PCs\u003c\/li\u003e\n\u003cli\u003eIntegrated RS485 communication interface\u003c\/li\u003e\n\u003cli\u003e9-pin D-sub socket connector\u003c\/li\u003e\n\u003cli\u003eEnd-point configuration with echo support\u003c\/li\u003e\n\u003cli\u003eIntegrated termination resistors for network stability\u003c\/li\u003e\n\u003cli\u003eDesigned for modular industrial control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed industrial machine control\u003c\/li\u003e\n\u003cli\u003eDistributed data acquisition systems\u003c\/li\u003e\n\u003cli\u003eSerial communication gateway applications\u003c\/li\u003e\n\u003cli\u003eReal-time automation logic processing\u003c\/li\u003e\n\u003cli\u003eModular PLC and motion control architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eCX2040-N031-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eBasic CPU module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD-sub socket, 9-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eEnd point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Features\u003c\/td\u003e\n\u003ctd\u003eEcho support, Termination on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the \u003cstrong\u003eCX2040-N031-0001\u003c\/strong\u003e is securely fastened to the DIN rail system compatible with the CX2000 series housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for the RS485 connection to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e As the module is configured as an end point with termination enabled, ensure it is placed at the physical end of the RS485 bus segment to prevent signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the operating environment within specified thermal limits to ensure long-term CPU reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a solid electrical connection to the cabinet chassis to maintain signal reference levels and ESD protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106591695211,"sku":"CX2040-N031-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx2040-n031-0001-1dzouck2zrx.png?v=1776244202","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-cx2040-n031-0001-cx2000-series-basic-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}