{"product_id":"beckhoff-ip3102-b520-devicenet-fieldbus-box","title":"Beckhoff IP3102-B520 DeviceNet Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized industrial field networks require rugged, reliable interfaces to bridge remote process points with centralized controllers. The \u003cstrong\u003eBeckhoff IP3102-B520\u003c\/strong\u003e is a high-performance \u003cstrong\u003eDeviceNet Fieldbus Box\u003c\/strong\u003e engineered for direct mounting in demanding production environments without requiring a protective control cabinet. By utilizing integrated DeviceNet connectivity, this module handles field-level physical signals and transmits them over a robust industrial bus connection.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with an automatic baud rate detector supporting speeds up to 500 kbaud, the \u003cstrong\u003eIP3102-B520\u003c\/strong\u003e adapts dynamically to network speeds. It features robust electrical isolation rated at 500 V between the control voltage circuitry and the fieldbus network, ensuring signal integrity and system protection. Configuration is easily completed via the Beckhoff KS2000 software interface or directly from the master controller utilizing explicit messaging protocols.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNative DeviceNet protocol communication with automatic baud rate detection up to 500 kbaud.\u003c\/li\u003e\n  \u003cli\u003eHardened IP65, IP66, and IP67-rated enclosure designed for direct field-level installation in harsh environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible I\/O communication modes, including bit strobe, polling, cyclic, and change of state (COS) options.\u003c\/li\u003e\n  \u003cli\u003ePower daisy-chaining via robust M8 connection interfaces (feed and downstream loop-through).\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the control voltage and the fieldbus system to safeguard sensitive electronic components.\u003c\/li\u003e\n  \u003cli\u003eCompact and light design, resistant to industrial shock and vibration in compliance with EN 60068 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized manufacturing automation systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines and robotic work cells.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and high-throughput material handling lines.\u003c\/li\u003e\n  \u003cli\u003eHeavy packaging machinery and processing industries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP3102-B520\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol \/ Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connection (Feed)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connection (Downstream)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (control voltage \/ fieldbus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Communication Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBit strobe, polling, cyclic, change of state (COS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals and Markings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"text-align: left;\"\u003eConnector Type\u003c\/th\u003e\n      \u003cth style=\"text-align: left;\"\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 (5-pin Plug)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet Fieldbus connection interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 (4-pin Male)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC system power feed input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 (4-pin Female)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC downstream power output loop-through\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the Fieldbus Box on a flat, vibration-resistant surface using standard mounting screws. Installation orientation is flexible.\u003c\/li\u003e\n  \u003cli\u003eEnsure that all M12 and M8 protective caps or cable connectors are tightened to the specified torque to maintain the IP67 ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003eUse only shielded copper cables for the bus line to comply with standard DeviceNet electromagnetic compatibility standards.\u003c\/li\u003e\n  \u003cli\u003eVerify that the total current draw of connected sensors via the M8 loop does not exceed the maximum rating of 0.5 A.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106444239211,"sku":"IP3102-B520","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3102-b520-yrlce1njr3q.png?v=1776245080","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-ip3102-b520-devicenet-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}