{"product_id":"beckhoff-ip3202-b200-fieldbus-box-lightbus-rtd-input-module","title":"Beckhoff IP3202-B200 Fieldbus Box Lightbus RTD Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for decentralized temperature acquisition in demanding industrial environments, the \u003cstrong\u003eBeckhoff IP3202-B200\u003c\/strong\u003e fieldbus box delivers precise RTD sensor processing directly at the machine level without requiring a protective control cabinet. This module integrates high-performance analog-to-digital conversion with the noise-immune Lightbus fiber-optic communication system, allowing reliable long-distance signal transmission in high-interference settings. The physical enclosure is built to withstand extreme mechanical stress, moisture, and dust, providing direct-to-machine mountability for minimized field-wiring loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLightbus Interface:\u003c\/strong\u003e Employs dual optical fiber connections operating at 2.5 Mbaud, providing absolute electrical isolation and immunity against electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect RTD Acquisition:\u003c\/strong\u003e Optimized for standard RTD and Pt100 temperature sensors without requiring external signal transmitters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust IP67 Enclosure:\u003c\/strong\u003e Designed for direct field mounting in wet, dusty, or high-vibration environments, complying with IP65, IP66, and IP67 protection standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Power Daisy-Chaining:\u003c\/strong\u003e Dual M8 connectors (male feed and female downstream) enable direct distribution of control voltages across multiple fieldbus boxes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Configuration:\u003c\/strong\u003e Accessible parameters and calibration settings manageable via Beckhoff KS2000 software or directly through controller register structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003eDecentralized temperature sensing in washdown areas, food processing, and chemical production.\u003c\/li\u003e\n  \u003cli\u003eRemote monitoring on highly articulated mechanical systems and robotic assemblies.\u003c\/li\u003e\n  \u003cli\u003eNoise-sensitive installations where traditional copper fieldbus lines suffer from EMI\/RFI issues.\u003c\/li\u003e\n  \u003cli\u003eDistributed HVAC and environmental control loops in large industrial facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP3202-B200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eFieldbus System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLightbus (Fiber-Optic Ring)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eData Transfer Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.5 Mbaud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBus Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x fiber-optic socket for ZS1020-0010 plug\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eControl Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eControl voltage to fieldbus: Yes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eWeight (Net)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e250 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.55 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e180 mm x 110 mm x 60 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eM8 Pin Location\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: Control Voltage +24 V DC \/ Downstream: Control Voltage +24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: Auxiliary\/Load Voltage +24 V DC \/ Downstream: Auxiliary\/Load Voltage +24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: GND Control Voltage \/ Downstream: GND Control Voltage\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: GND Auxiliary\/Load Voltage \/ Downstream: GND Auxiliary\/Load Voltage\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP3202-B200 module is designed specifically for Beckhoff Lightbus architectures. If migrating or integrating with newer control platforms, keep in mind that Lightbus requires dedicated master PCI\/PCIe cards (e.g., FC2001) or specific bus terminal controllers. For applications looking to migrate to EtherCAT without altering physical layouts, equivalent models from the EP series (such as the EP3202-0002) should be considered, though a change in network architecture and cabling from fiber-optic to industrial Ethernet is required.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen working with fiber-optic connections in industrial rings, maintaining optical clean room standards is critical during physical installations. Avoid exceeding the minimum bending radius of the fiber-optic cabling (typically 30 mm for ZS1020 assemblies) to prevent signal loss or permanent physical degradation of the polymer fibers. Furthermore, any open or unused M8 or fiber-optic ports must be sealed using certified protective IP67 caps. Leaving these connections open in wet environments invites capillary moisture ingress, which can corrode internal components over time.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo configure analog channel operational characteristics, use the Beckhoff KS2000 software package connected via a serial configuration cable, or access the internal registry directly through the PLC startup parameters in TwinCAT. Ensure that the sensor cabling shields are terminated close to the fieldbus module's metal mounting ears to provide a low-impedance path to local earth ground, preventing high-frequency common-mode noise from corrupting delicate RTD measurements.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all power sources (both control and auxiliary load voltages) before performing any mounting, physical cleaning, or wiring modifications on the module. High-intensity light is used in optical networks; never look directly into the transmitter optical fiber or fiber-optic port while the system is powered.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the Fieldbus Box securely onto a flat, vibration-resistant surface using two M4 bolts through the integrated mounting flanges.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eEnsure the local machine frame is connected to a reliable system ground, and bond the module’s mounting surface appropriately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInsert clean, undamaged fiber-optic cables (ZS1020-0010 connectors) into the optical interfaces until they click securely into place.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: center; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the M8 power cables, ensuring they are tightened to the recommended torque specifications to maintain the IP67 integrity.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106429133163,"sku":"IP3202-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3202-b200-znu2j43u1rc.png?v=1776245086","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-ip3202-b200-fieldbus-box-lightbus-rtd-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}