{"product_id":"beckhoff-ks3001-bus-terminal-1-channel-analog-input-module","title":"Beckhoff KS3001 Bus Terminal 1-Channel Analog Input Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing analog differential signals within the Beckhoff I\/O system, the \u003cstrong\u003eBeckhoff KS3001\u003c\/strong\u003e Bus Terminal delivers high-precision voltage measurement across a \u003cstrong\u003e-10 to +10 V\u003c\/strong\u003e range. This single-channel module features a pluggable wiring design, allowing rapid field replacement without disturbing the terminal wiring harness. Operating directly on the K-bus, it transmits digitized measurement values to the higher-level controller with electrical isolation, making it ideal for demanding industrial environments requiring reliable signal acquisition.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSingle-channel differential input architecture for high noise immunity.\u003c\/li\u003e\n  \u003cli\u003ePluggable wiring level (KS series) for tool-free terminal replacement.\u003c\/li\u003e\n  \u003cli\u003e12-bit analog-to-digital conversion resolution (11-bit for 0 to 10 V range).\u003c\/li\u003e\n  \u003cli\u003eComplete 500 V electrical isolation between the K-bus and the signal circuit.\u003c\/li\u003e\n  \u003cli\u003eDirect power supply via the K-bus, eliminating the need for lateral power contacts.\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm housing width for high-density DIN rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDifferential voltage monitoring in industrial process control.\u003c\/li\u003e\n  \u003cli\u003eSensor integration in test benches and laboratory automation.\u003c\/li\u003e\n  \u003cli\u003eAnalog signal acquisition in high-noise electrical environments.\u003c\/li\u003e\n  \u003cli\u003eTwinCAT-based distributed control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eKS3001\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSignal Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 to +10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDifferential input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInternal Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003etyp. \u0026gt; 200 kOhm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommon-Mode Voltage (Ucm)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003emax. 35 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 bit (11 bit for 0 to 10 V range)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConversion Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003etyp. 1 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMeasuring Error\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e\u0026lt; ±0.3% (relative to full scale value)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCurrent Consumption (K-bus)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003etyp. 65 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProcess Image Bit Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInput: 1 x 16 bit data (1 x 8 bit control\/status optional)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Cross-Section\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSolid\/Stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eConnection Cross-Section AWG\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSolid\/Stranded: AWG 28 to 16, Fine-wire: AWG 26 to 16\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStripping Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9 to 10 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to +55 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e95%, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEx Marking\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e70 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.15 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe KS3001 is the pluggable-wiring equivalent of the standard KL3001 Bus Terminal. While they share identical electrical specifications, register mappings, and TwinCAT configurations, the KS3001 features a detachable terminal block. This allows field maintenance teams to replace a faulty module without disconnecting any field wiring, significantly reducing downtime in critical process loops.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways verify that the common-mode voltage (Ucm) between the differential inputs and the internal K-bus ground does not exceed the absolute maximum limit of 35 V. Exceeding this threshold will saturate the differential input stage, resulting in clipped or highly inaccurate readings, and can eventually lead to permanent hardware degradation of the input operational amplifiers.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor high-accuracy applications, use shielded twisted-pair (STP) cabling for the analog signal lines. Connect the cable shield to a low-impedance functional earth (FE) ground rail as close to the terminal entry point as possible. In TwinCAT, the process image can be configured to include control and status bytes (1x8 bit) to monitor diagnostic flags such as overrange or underrange conditions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #2d3748; font-size: 0.95rem;\"\u003eDe-energize the entire Bus Terminal system (both K-bus power supply and any field-side voltages) before inserting, removing, or wiring the KS3001 module. Failure to do so can cause electrical arcing, damage the internal K-bus contacts, or corrupt the process image of adjacent terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) by sliding it onto the rail until the locking mechanism engages securely.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the module laterally to connect it with the adjacent Bus Terminals, ensuring the tongue-and-groove slot connection and the lateral K-bus contacts are fully mated.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert the pluggable wiring block into the front of the terminal housing until it clicks into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the differential signal lines using a screwdriver to actuate the spring clamps. Strip the wire ends to 9–10 mm before insertion.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106541035883,"sku":"KS3001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks3001-l3cusfxbspg.png?v=1776245277","url":"https:\/\/www.plcprotech.com\/tr\/products\/beckhoff-ks3001-bus-terminal-1-channel-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}