{"product_id":"bently-nevada-330103-03-06-05-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-03-06-05-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-03-06-05-02-00\u003c\/strong\u003e is a metric-threaded \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e configuration engineered without external coaxial armor. This specific model features an M10 x 1 case thread, a 30 mm unthreaded length (Option 03), a 60 mm overall case length (Option 06), and a 0.5-meter (1.6-foot) total length (Option 05). Designed with a standard cable and a miniature coaxial ClickLoc connector (Option 02), this unit is configured without hazardous area approvals (Option 00), making it ideal for standard, non-certified industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eThis probe serves as an eddy-current displacement sensor within the Bently Nevada 3300 XL machinery protection system. It measures static and dynamic distance between the probe tip and a conductive target, such as a fluid-film bearing shaft. By operating in conjunction with a 3300 XL Proximitor sensor and a corresponding extension cable, this 0.5-meter probe is calibrated to measure shaft vibration, axial position, and Keyphasor speed references.\u003c\/p\u003e\n\n\u003cp\u003eUnlike variants configured with stainless steel armor (such as the 330104 series) or those with integrated connector protectors (Option 01), this unarmored configuration utilizes a standard FEP insulated cable and a bare ClickLoc connector for direct routing in protected conduits. Additionally, its short 0.5-meter total length is ideal for space-constrained installations where the connection to the extension cable occurs near the machine housing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric case thread: M10 x 1 thread size with a hex size of M10.\u003c\/li\u003e\n  \u003cli\u003eCase dimensions: 60 mm overall case length with a 30 mm unthreaded section, complying with the minimum 20 mm differential rule.\u003c\/li\u003e\n  \u003cli\u003e0.5-meter total length: Compact cable run optimized for close-coupled connection to standard extension cables.\u003c\/li\u003e\n  \u003cli\u003eClickLoc coaxial connector: Gold-plated miniature male coaxial connector without a connector protector (Option 02).\u003c\/li\u003e\n  \u003cli\u003eUnarmored cable: Standard 75 Ohm triaxial FEP insulated probe cable for standard routing.\u003c\/li\u003e\n  \u003cli\u003eTarget compatibility: Calibrated for AISI 4140 steel targets.\u003c\/li\u003e\n  \u003cli\u003eTemperature rating: Standard operating temperature range of -52 degC to +177 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRotating machinery monitoring in fluid-film bearing environments.\u003c\/li\u003e\n  \u003cli\u003eRadial shaft vibration measurement in industrial motors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position tracking on industrial turbines and centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eSpeed and Keyphasor reference measurements on high-speed rotating elements.\u003c\/li\u003e\n  \u003cli\u003eRetrofitting existing non-XL metric installations using M10 x 1 threads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from PDF Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003e30 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330103-03-06-05-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Thread Size\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e30 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector (without protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial FEP insulated standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e7.45 ohms (plus\/minus 0.50 ohms) center conductor to outer conductor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax Tensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) case-to-lead pull strength\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax Connector Torque\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e150 mm x 150 mm x 30 mm (H x W x D) (coiled package envelope)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Element\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eSignal (probe coil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Conductor \/ Shield\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Ensure minimum cable bend radius of 25.4 mm is observed to prevent signal attenuation or mechanical damage to the coaxial layers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Thread engagement into the machine housing must not exceed 15 mm. Tighten probe case to a maximum recommended torque of 22.6 N-m (200 in-lbf).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Maintenance:\u003c\/strong\u003e Ensure coaxial ClickLoc connectors are kept clean, dry, and free of turbine oil or moisture. Align and press together until the mechanical \"click\" is felt. Do not over-torque past 0.565 N-m (5 in-lbf) if connection tools are used.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the sensor shielding is properly terminated to prevent electrostatic or electromagnetic interference in the final signal path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Option 00) does not require hazardous area certifications and is designed for use in standard, general-purpose industrial environments. General compliance includes CE Mark and RoHS guidelines where applicable.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666765443435,"sku":"330103-03-06-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-03-06-05-02-00-3300-xl-8-mm-proximity-probes-1r03uedspsu_cbd82c27-e21e-4b19-acf8-185e6e0a11dd.jpg?v=1765447216","url":"https:\/\/www.plcprotech.com\/tr\/products\/bently-nevada-330103-03-06-05-02-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}